929 resultados para Maximum Power Point Tracking
Resumo:
Long-term electrocardiogram (ECG) signals might suffer from relevant baseline disturbances during physical activity. Motion artifacts in particular are more pronounced with dry surface or esophageal electrodes which are dedicated to prolonged ECG recording. In this paper we present a method called baseline wander tracking (BWT) that tracks and rejects strong baseline disturbances and avoids concurrent saturation of the analog front-end. The proposed algorithm shifts the baseline level of the ECG signal to the middle of the dynamic input range. Due to the fast offset shifts, that produce much steeper signal portions than the normal ECG waves, the true ECG signal can be reconstructed offline and filtered using computationally intensive algorithms. Based on Monte Carlo simulations we observed reconstruction errors mainly caused by the non-linearity inaccuracies of the DAC. However, the signal to error ratio of the BWT is higher compared to an analog front-end featuring a dynamic input ranges above 15 mV if a synthetic ECG signal was used. The BWT is additionally able to suppress (electrode) offset potentials without introducing long transients. Due to its structural simplicity, memory efficiency and the DC coupling capability, the BWT is dedicated to high integration required in long-term and low-power ECG recording systems.
Resumo:
This article gives details of our proposal to replace ordinary chiral SU(3)L×SU(3)R perturbation theory χPT3 by three-flavor chiral-scale perturbation theory χPTσ. In χPTσ, amplitudes are expanded at low energies and small u,d,s quark masses about an infrared fixed point αIR of three-flavor QCD. At αIR, the quark condensate ⟨q¯q⟩vac≠0 induces nine Nambu-Goldstone bosons: π,K,η, and a 0++ QCD dilaton σ. Physically, σ appears as the f0(500) resonance, a pole at a complex mass with real part ≲ mK. The ΔI=1/2 rule for nonleptonic K decays is then a consequence of χPTσ, with a KSσ coupling fixed by data for γγ→ππ and KS→γγ. We estimate RIR≈5 for the nonperturbative Drell-Yan ratio R=σ(e+e−→hadrons)/σ(e+e−→μ+μ−) at αIR and show that, in the many-color limit, σ/f0 becomes a narrow qq¯ state with planar-gluon corrections. Rules for the order of terms in χPTσ loop expansions are derived in Appendix A and extended in Appendix B to include inverse-power Li-Pagels singularities due to external operators. This relates to an observation that, for γγ channels, partial conservation of the dilatation current is not equivalent to σ-pole dominance.
Resumo:
Passive positioning systems produce user location information for third-party providers of positioning services. Since the tracked wireless devices do not participate in the positioning process, passive positioning can only rely on simple, measurable radio signal parameters, such as timing or power information. In this work, we provide a passive tracking system for WiFi signals with an enhanced particle filter using fine-grained power-based ranging. Our proposed particle filter provides an improved likelihood function on observation parameters and is equipped with a modified coordinated turn model to address the challenges in a passive positioning system. The anchor nodes for WiFi signal sniffing and target positioning use software defined radio techniques to extract channel state information to mitigate multipath effects. By combining the enhanced particle filter and a set of enhanced ranging methods, our system can track mobile targets with an accuracy of 1.5m for 50% and 2.3m for 90% in a complex indoor environment. Our proposed particle filter significantly outperforms the typical bootstrap particle filter, extended Kalman filter and trilateration algorithms.
Resumo:
We present a power-scalable approach for yellow laser-light generation based on standard Ytterbium (Yb) doped fibers. To force the cavity to lase at 1154 nm, far above the gain-maximum, measures must be taken to fulfill lasing condition and to suppress competing amplified spontaneous emission (ASE) in the high-gain region. To prove the principle we built a fiber-laser cavity and a fiber-amplifier both at 1154 nm. In between cavity and amplifier we suppressed the ASE by 70 dB using a fiber Bragg grating (FBG) based filter. Finally we demonstrated efficient single pass frequency doubling to 577 nm with a periodically poled lithium niobate crystal (PPLN). With our linearly polarized 1154 nm master oscillator power fiber amplifier (MOFA) system we achieved slope efficiencies of more than 15 % inside the cavity and 24 % with the fiber-amplifier. The frequency doubling followed the predicted optimal efficiency achievable with a PPLN crystal. So far we generated 1.5 W at 1154nm and 90 mW at 577 nm. Our MOFA approach for generation of 1154 nm laser radiation is power-scalable by using multi-stage amplifiers and large mode-area fibers and is therefore very promising for building a high power yellow laser-light source of several tens of Watt.
Resumo:
PURPOSE Rituximab maintenance therapy has been shown to improve progression-free survival in patients with follicular lymphoma; however, the optimal duration of maintenance treatment remains unknown. PATIENTS AND METHODS Two hundred seventy patients with untreated, relapsed, stable, or chemotherapy-resistant follicular lymphoma were treated with four doses of rituximab monotherapy in weekly intervals (375 mg/m(2)). Patients achieving at least a partial response were randomly assigned to receive maintenance therapy with one infusion of rituximab every 2 months, either on a short-term schedule (four administrations) or a long-term schedule (maximum of 5 years or until disease progression or unacceptable toxicity). The primary end point was event-free survival (EFS). Progression-free survival, overall survival (OS), and toxicity were secondary end points. Comparisons between the two arms were performed using the log-rank test for survival end points. RESULTS One hundred sixty-five patients were randomly assigned to the short-term (n = 82) or long-term (n = 83) maintenance arms. Because of the low event rate, the final analysis was performed after 95 events had occurred, which was before the targeted event number of 99 had been reached. At a median follow-up period of 6.4 years, the median EFS was 3.4 years (95% CI, 2.1 to 5.3) in the short-term arm and 5.3 years (95% CI, 3.5 to not available) in the long-term arm (P = .14). Patients in the long-term arm experienced more adverse effects than did those in the short-term arm, with 76% v 50% of patients with at least one adverse event (P < .001), five versus one patient with grade 3 and 4 infections, and three versus zero patients discontinuing treatment because of unacceptable toxicity, respectively. There was no difference in OS between the two groups. CONCLUSION Long-term rituximab maintenance therapy does not improve EFS, which was the primary end point of this trial, or OS, and was associated with increased toxicity.
Resumo:
Strategic control is defined as the use of qualitative and quantitative tools for the evaluation of strategic organizational performance. Most research in strategic planning has focused on strategy formulation and implementation, but little work has been done on strategic performance evaluation particularly in the area of cancer research. The objective of this study was to identify strategic control approaches and financial performance metrics used by major cancer centers in the country as an initial step in expanding the theory and practice behind strategic organizational performance. Focusing on hospitals which share similar mandate and resource constraints was expected to improve measurement precision. The results indicate that most cancer centers use a wide selection of evaluation tools, but sophisticated analytical approaches were less common. In addition, there was evidence that high-performing centers tend to invest a larger degree of resources in the area of strategic performance analysis than centers showing lower financial results. The conclusions point to the need for incorporating higher degree of analytical power in order to improve the tracking of strategic performance. This study is one of the first to concentrate in the area of strategic control.^
Resumo:
An interim analysis is usually applied in later phase II or phase III trials to find convincing evidence of a significant treatment difference that may lead to trial termination at an earlier point than planned at the beginning. This can result in the saving of patient resources and shortening of drug development and approval time. In addition, ethics and economics are also the reasons to stop a trial earlier. In clinical trials of eyes, ears, knees, arms, kidneys, lungs, and other clustered treatments, data may include distribution-free random variables with matched and unmatched subjects in one study. It is important to properly include both subjects in the interim and the final analyses so that the maximum efficiency of statistical and clinical inferences can be obtained at different stages of the trials. So far, no publication has applied a statistical method for distribution-free data with matched and unmatched subjects in the interim analysis of clinical trials. In this simulation study, the hybrid statistic was used to estimate the empirical powers and the empirical type I errors among the simulated datasets with different sample sizes, different effect sizes, different correlation coefficients for matched pairs, and different data distributions, respectively, in the interim and final analysis with 4 different group sequential methods. Empirical powers and empirical type I errors were also compared to those estimated by using the meta-analysis t-test among the same simulated datasets. Results from this simulation study show that, compared to the meta-analysis t-test commonly used for data with normally distributed observations, the hybrid statistic has a greater power for data observed from normally, log-normally, and multinomially distributed random variables with matched and unmatched subjects and with outliers. Powers rose with the increase in sample size, effect size, and correlation coefficient for the matched pairs. In addition, lower type I errors were observed estimated by using the hybrid statistic, which indicates that this test is also conservative for data with outliers in the interim analysis of clinical trials.^