966 resultados para Magnetic field


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Magnetic liquid marbles exhibit a remarkable ability to be opened and closed reversibly under the action of a magnetic field. Liquid can be either extracted from or added to the opened liquid marble simply with a capillary needle. Two opened liquid marbles can also be coalesced into a larger one. The magnetic liquid marbles can be maneuvered two- and three-dimensionally.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents novel vehicle detection and classification method by measuring and processing magnetic signal based on single micro-electro- mechanical system (MEMS) magnetic sensor. When a vehicle moves over the ground, it generates a succession of impacts on the earth's magnetic field, which can be detected by single magnetic sensor. The magnetic signal measured by the magnetic sensor is related to the moving direction and the type of the vehicle. Generally, the recognition rate using single sensor detector is not high. In order to improve the recognition rate, a novel feature extraction algorithm and a novel vehicle classification and recognition algorithm are presented. The concavity and convexity areas, and the angles of concave and convex parts of the waveform are extracted. An improved support vector machine (ISVM) classifier is developed to perform vehicle classification and recognition. The effectiveness of the proposed approach is verified by outdoor experiments.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper, we report on the production of superhydrophobic coatings on various substrates (e.g., glass slide, silicon wafer, aluminum foil, plastic film, nanofiber mat, textile fabrics) using hydrophobic magnetic nanoparticles and a magnet-assembly technique. Fe3O4 magnetic nanoparticles functionalized with a thin layer of fluoroalkyl silica on the surface were synthesized by one-step coprecipitation of Fe2+/Fe3+ under an alkaline condition in the presence of a fluorinated alkyl silane. Under a magnetic field, the magnetic nanoparticles can be easily deposited on any solid substrate to form a thin superhydrophobic coating with water contact angle as high as 172°, and the surface superhydrophobicity showed very little dependence on the substrate type. The particulate coating showed reasonable durability because of strong aggregation effect of nanoparticles, but the coating layer can be removed (e.g., by ultrasonication) to restore the original surface feature of the substrates. By comparison, the thin particle layer deposited under no magnetic field showed much lower hydrophobicity. The main reason for magnet-induced superhydrophobic surfaces is theformation of nano- and microstructured surface features. Such a magnet-induced temporary superhydrophobic coating may have wide applications in electronic, biomedical, and defense-related areas.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A washer-free Nb nanoSQUID has been developed for measuring magnetization changes from nanoscale objects. The SQUID loop is etched into a 250 nm wide Au/Nb bilayer track and the diameter of the SQUID hole is ~ 70 nm. In the presence of a magnetic field perpendicular to the plane of the SQUID, vortex penetration into the 250 nm wide track can be observed via the critical current–applied field characteristic and the value at which vortex first penetrates is consistent with the theoretical prediction. Upon removing the applied field, the penetrated vortices escape the track and the critical current at zero field is restored.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A mathematical model of magnetohydrodynamic (MHD) effects in an aluminium cell using numerical approximation of a finite element method is presented. The model predicts the current distribution in the cell and calculates the Lorentz force from the external magnetic field in molten metal for cathode blocks with different surface inclinations.

The findings indicated that the cathode surface inclinations have significant influence on cathode current density and Lorentz field distribution in the molten metal. The results establish a trend for the current density and associated MHD force distributions with increase in cathode inclination angle, φ. It has been found that cathode with φ = 5o inclination could decrease 16 to 20 % of Lorentz force in the molten metal.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Magnetic liquid marbles, an encapsulation of liquid droplet with hydrophobic magnetic particles, show remarkable responsiveness to external magnetic force and great potential to be used as a discrete droplet microfluidic system. In this study, we presented the manipulation of a magnetic liquid marble under an external magnetic field and calculated the maximum frictional force, the magnetic force required for actuating the liquid marbles and the effective surface tension of the magnetic liquid marble, as well as the threshold volume for the transition from quasi-spherical to puddle-like shape. By taking advantage of the unique feature of being opened and closed reversibly, we have proven the encapsulated droplets can be detected optically with a reflection-mode probe. Combining the open-close and optical detection also enables to probe chemical reactions taking place within liquid marbles. These remarkable features offer a simple yet powerful alternative to conventional discrete microfluidic systems and may have wide applications in biomedical and drug discovery. © 2012 The Author(s).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Whilst a range of animals have been shown to respond behaviourally to components of the Earth’s magnetic field, evidence of the value of this sensory perception for small animals advected by strong flows (wind/ocean currents) is equivocal. We added geomagnetic directional swimming behaviour for North Atlantic loggerhead turtle hatchlings (Caretta caretta) into a high-resolution (1/4°) global general circulation ocean model to simulate 2,925-year-long hatchling trajectories comprising 355,875 locations. A little directional swimming (1–3 h per day) had a major impact on trajectories; simulated hatchlings travelled further south into warmer water. As a result, thermal elevation of hatchling metabolic rates was estimated to be between 63.3 and 114.5% after 220 days. We show that even small animals in strong flows can benefit from geomagnetic orientation and thus the potential implications of directional swimming for other taxa may be broad.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Magnetic force microscopy (MFM) signals have recently been detected from whole pieces of mechanically exfoliated graphene and molybdenum disulfide (MoS2) nanosheets, and magnetism of the two nanomaterials was claimed based on these observations. However, non-magnetic interactions or artefacts are commonly associated with MFM signals, which make the interpretation of MFM signals not straightforward. A systematic investigation has been done to examine possible sources of the MFM signals from graphene and MoS2 nanosheets and whether the MFM signals can be correlated with magnetism. It is found that the MFM signals have significant non-magnetic contributions due to capacitive and electrostatic interactions between the nanosheets and conductive cantilever tip, as demonstrated by electric force microscopy and scanning Kevin probe microscopy analyses. In addition, the MFM signals of graphene and MoS2 nanosheets are not responsive to reversed magnetic field of the magnetic cantilever tip. Therefore, the observed MFM response is mainly from electric artefacts and not compelling enough to correlate with magnetism of graphene and MoS2 nanosheets.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A magnetic resin based on cardanol, furfural, and curaua fibers was prepared and characterized. The material could be used in oil-spill cleanup processes, because of its aromatic/aliphatic balance. The resin was prepared through bulk polycondensation of cardanol and furfural in the presence of curaua fibers and maghemite nanoparticles. Hydrophobicity of the curaua fibers was improved by acetylation, increasing the oil-absorbing capability of the composites. The obtained magnetic composites were studied by Fourier-transform infrared spectroscopy, X-ray diffraction, and thermogravimetric analysis. Degree of cure, magnetic force, and oil-removal capability tests were also performed. The results show that the composites possess an elevated cure degree in addition to a considerable magnetic force. The materials exhibit a good oil removal capability in the presence of a magnetic field, which is improved by the use of acetylated curaua. In the best case, the composite filled with maghemite and curaua can remove 12 parts of oil from water.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents a comprehensive analytical subdomain model together with its field solutions for predicting the magnetic field distributions in surface-mounted permanent magnet (PM) machines. The tooth tips and slotting effects during open-circuit, armature reaction, and on-load conditions are considered when deriving the model and developing its solutions. The model derivations and field solutions are extended from a previous model, and can be applied to PM machines with any combinations of slot and pole numbers and any magnetization patterns in the magnets. This model is initially formulated according to Laplace's and Poisson's equations in 2-D polar coordinates by the separation of variables technique in four subdomains, such as magnet, airgap, winding slots, and slot-openings. The field solution of each subdomain is obtained applying the appropriate boundary conditions and interface conditions between every two subdomains, respectively, which can precisely account for the mutual influence between slots. Finite element analysis (FEA) is later deployed to validate the analytical results in a surface-mounted PM machine that has nonoverlapping winding arrangement. For validation purposes, PM machines having 3-slot/2-pole with parallel magnetization and 12-slot/10-pole with either parallel or radial magnetizations are used for comparisons. Computation of global quantities for the motor which include the phase back-EMF and cogging torque is also included. The results indicate that the proposed analytical model can accurately predict the magnetic field distributions in each subdomain and the motor's global quantities, which are in good agreement with those obtained from the FEA.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective. Measure physical therapists' exposure to the electric and magnetic fields produced by 17 shortwave diathermy devices in physical therapy clinics in the city of Presidente Prudente, São Paulo State, Brazil. Compare the observed values with the exposure levels recommended by the International Commission on Non-ionizing Radiation Protection (ICNIRP). Observe the efficacy of Faraday cages as a means of protecting physical therapists from exposure to oscillating electric and magnetic fields.Methods. Electric and magnetic field measurements were taken at four points during actual physical therapy sessions: in proximity to the operator's pelvis and head, the devices' electrical cables, and the electrodes. The measuring equipment was a Wandel & Goltermann EMR-200.Results. The values obtained in proximity to the electrodes and cables were 10 to 30 times higher than ICNIRP's recommended occupational reference levels. In the shortwave diathermy treatment rooms with Faraday cages, the fields were even higher than in treatment rooms not so equipped-principally the magnetic field, where the values were more than 100 times higher than the ICNIRP exposure limit.Conclusions. The electric and magnetic field intensities obtained in this study are generally above the exposure levels recommend in ICNIRP standards. It was also observed that the Faraday cage offers physical therapists no protection, and instead, increases their level of exposure.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The effects of an in-plane electric field and eccentricity on the electronic spectrum of a GaAs quantum ring in a perpendicular magnetic field are studied. The effective-mass equation is solved by two different methods: an adiabatic approximation and a diagonalization procedure after a conformal mapping. It is shown that the electric field and the eccentricity may suppress the Aharonov-Bohm oscillations of the lower energy levels. Simple expressions for the threshold energy and the number of flat energy bands are found. In the case of a thin and eccentric ring, the intensity of a critical field which compensates the main effects of eccentricity is determined. The energy spectra are found in qualitative agreement with previous experimental and theoretical works on anisotropic rings.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work we describe a two-dimensional computer simulation of magnetic field enhanced plasma immersion implantation system. Negative bias voltage of 10.0 kV is applied to a cylindrical target located on the axis of a grounded vacuum chamber filled with uniform nitrogen plasma. A pair of external coils creates a static magnetic field with main vector component along the axial direction. Thus, a system of crossed ExB field is generated inside the vessel forcing plasma electrons to rotate in azimuthal direction. In addition, the axial variation of the magnetic field intensity produces magnetic mirror effect that enables axial particle confinement. It is found that high-density plasma regions are formed around the target due to intense background gas ionization by the trapped electrons. Effect of the magnetic field on the sheath dynamics and the implantation current density of the PIII system is investigated. By changing the magnetic field axial profile (varying coils separation) an enhancement of about 30% of the retained dose can be achieved. The results of the simulation show that the magnetic mirror configuration brings additional benefits to the PIII process, permitting more precise control of the implanted dose.