986 resultados para MAGNETIC PROPERTIES


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recentment, ha crescut un notable interès pels materials multiferroics (o materials que presenten simultàniament propietats elèctriques i magnètiques), a causa de les seves múltiples aplicacions, sobretot en el camp de l"electrònica. Aquest article pretén donar a conèixer els materials multiferroics, tant des del punt de vista de la física fonamental com de la química de l"estat sòlid. Tanmateix, es presentarà un dels materials multiferroics actualment més estudiats i s"exposaran els detalls de la seva síntesi i caracterització habituals en la química de l"estat sòlid.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cardiovascular disease is the leading cause of death worldwide. Within this subset, coronary artery disease (CAD) is the most prevalent. Magnetic resonance angiography (MRA) is an emerging technique that provides a safe, non-invasive way of assessing CAD progression. To generate contrast between tissues, MR images are weighted according to the magnetic properties of those tissues. In cardiac MRI, T2 contrast, which is governed by the rate of transverse signal loss, is often created through the use of a T2-Preparation module. T2-Preparation, or T2-Prep, is a magnetization preparation scheme used to improve blood/myocardium contrast in cardiac MRI. T2-Prep methods generally use a non-selective +90°, 180°, 180°, -90° train of radiofrequency (RF) pulses (or variant thereof), to tip magnetization into the transverse plane, allow it to evolve, and then to restore it to the longitudinal plane. A key feature in this process is the combination of a +90° and -90° RF pulse. By changing either one of these, a mismatch occurs between signal excitation and restoration. This feature can be exploited to provide additional spectral or spatial selectivity. In this work, both of these possibilities are explored. The first - spectral selectivity - has been examined as a method of improving fat saturation in coronary MRA. The second - spatial selectivity - has been examined as a means of reducing imaging time by decreasing the field of view, and as a method of reducing artefacts originating from the tissues surrounding the heart. Two additional applications, parallel imaging and self-navigation, are also presented. This thesis is thus composed of four sections. The first, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", was originally published in the journal Magnetic Resonance in Medicine (MRM) with co-authors Ruud B. van Heeswijk and Matthias Stuber. The second, "Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", again with co-authors Ruud van Heeswijk and Matthias Stuber, was also published in the journal MRM. The third, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA-accelerated image quality in MRA of the right coronary artery", written with co-authors Jerome Yerly and Matthias Stuber, has been submitted to the "Journal of Cardiovascular Magnetic Resonance", and the fourth, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", with co¬authors Jerome Chaptinel, Giulia Ginami, Gabriele Bonanno, Simone Coppo, Ruud van Heeswijk, Davide Piccini, and Matthias Stuber, is undergoing internal review prior to submission to the journal MRM. -- Les maladies cardiovasculaires sont la cause principale de décès dans le monde : parmi celles-ci, les maladies coronariennes sont les plus répandues. L'angiographie par résonance magnétique (ARM) est une technique émergente qui fournit une manière sûre, non invasive d'évaluer la progression de la coronaropathie. Pour obtenir un contraste entre les tissus, les images d'IRM sont pondérées en fonction des propriétés magnétiques de ces tissus. En IRM cardiaque, le contraste en T2, qui est lié à la décroissance du signal transversal, est souvent créé grâce à l'utilisàtion d'un module de préparation T2. La préparation T2, ou T2-Prep, est un système de préparation de l'aimantation qui est utilisé pour améliorer le contraste entre le sang et le myocarde lors d'une IRM cardiaque. Les méthodes de T2-Prep utilisent généralement une série non-sélective d'impulsions de radiofréquence (RF), typiquement [+ 90°, 180°, 180°, -90°] ou une variante, qui bascule l'aimantation dans le plan transversal, lui permet d'évoluer, puis la restaure dans le plan longitudinal. Un élément clé de ce processus est la combinaison des impulsions RF de +90° et -90°. En changeant l'une ou l'autre des impulsions, un décalage se produit entre l'excitation du signal et de la restauration. Cette fonction peut être exploitée pour fournir une sélectivité spectrale ou spatiale. Dans cette thèse, les deux possibilités sont explorées. La première - la sélectivité spectrale - a été examinée comme une méthode d'améliorer la saturation de la graisse dans l'IRM coronarienne. La deuxième - la sélectivité spatiale - a été étudiée comme un moyen de réduire le temps d'imagerie en diminuant le champ de vue, et comme une méthode de réduction des artefacts provenant des tissus entourant le coeur. Deux applications supplémentaires, l'imagerie parallèle et la self-navigation, sont également présentées. Cette thèse est ainsi composée de quatre sections. La première, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", a été publiée dans la revue médicale Magnetic Resonance .in Medicine (MRM) avec les co-auteurs Ruud B. van Heeswijk et Matthias Stuber. La deuxième, Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", encore une fois avec les co-auteurs Ruud van Heeswijk et Matthias Stuber, a également été publiée dans le journal MRM. La troisième, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA- accelerated image quality in MRA of the right coronary artery", écrite avec les co-auteurs Jérôme Yerly et Matthias Stuber, a été présentée au "Journal of Cardiovascular Magnetic Resonance", et la quatrième, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", avec les co-auteurs Jérôme Chaptinel, Giulia Ginami, Gabriele Bonanno , Simone Coppo, Ruud van Heeswijk, Davide Piccini, et Matthias Stuber, subit un examen interne avant la soumission à la revue MRM.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple system to measure the magnetic susceptibility of different materials is presented. The system uses an analytical scale with sensitivity on the order of micrograms and a permanent NdBFe magnet, based in the Rankine method. In this apparatus, the sample is placed near to the magnet that is fixed on the scale. Depending on the magnetic properties of the sample, an attractive or repulsive force will appear between the magnet and the magnetizing sample. Measuring this force, registered by the scale as a mass, the magnetic parameters such as: permeability and susceptibility of the sample can be determined. Despite it is simplicity the method is quantitative, precise and easily reproducible in many laboratories, what makes it attractive for teaching experiments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work the adsorption features of zeolites (NaY, Beta, Mordenite and ZSM-5) have been combined with the magnetic properties of iron oxides in a composite to produce a magnetic adsorbent. These magnetic composites can be used as adsorbents for contaminants in water and subsequently removed from the medium by a simple magnetic process. The magnetic zeolites were characterized by XRD, magnetization measurements, chemical analyses, N2 adsorption isotherms and Mössbauer spectroscopy. These magnetic adsorbents show remarkable adsorption capacity for metal ion contaminants in water.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work temperature dependences of resistivity in zero field have been obtained for epitaxially grown Ga1_xMnxAs thin films with 6 % and 8 % Mn content in 50 300 K temperature range. Decrease of resistivity has been observed. Negative magnetoresistance has been explained by empirical spin dependent hopping model. Hall effect has been studied and anomalous Hall effect, inherent to ferromagnetic materials, has been observed. Both normal and anomalous Hall coefficients have been calculated from experimental data, as well as hole densities. Activation energy of impurity level has been estimated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work the adsorption features of hydrotalcites (Al, Mg- CO3) and the magnetic properties of iron oxides have been combined in a composite to produce a magnetic adsorbent. These magnetic composites can be used as adsorbents for anionic contaminants in water and subsequently removed from the medium by a simple magnetic process. The magnetic hydrotalcites were characterized by XRD, magnetization measurements, N2 adsorption isotherms and Mössbauer spectroscopy. These magnetic adsorbents show remarkable adsorption capacity for anionic contaminants in water.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper the evolution of the concept of aromaticity is discussed. It considers not only historical aspects of the aromaticity concept but also the different criteria (theoretical and experimental) that have appeared to explain the properties of the aromatic compounds. The topics range from the isolation of benzene by Faraday (1825) until the modern criteria based on geometries, magnetic properties, resonance energy (RE), aromatic stabilization energy (ASE), topological analyses, and others. A chronological separation of issues concerning aromaticity was made, splitting the definitions before and after the appearance of the quantum chemistry. This work reviews the concept of aromaticity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, hydrotalcite, a layered double hydroxide, had its adsorption and ion exchange properties combined with the magnetic properties of iron oxide to produce a magnetic adsorbent, HT-Fe. The removal of As(V) by a HT-Fe adsorbent was evaluated under various conditions. The Kinetic process was well described by a pseudo-second order rate model. The maximum adsorption capacity, calculated with the Langmuir model showed to be dependent on pH, reaching values of 24.09, 10.19 and 7.44 mg g-1, respectively, for pH values of 4.0, 7.0 and 9.0. The inhibition by competition of anions is dependent on the type of ionic species.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The perovskites are strategic materials due their catalytic, electronic and magnetic properties. These properties are influenced by the calcination and synthesis conditions. In this work was carried out the synthesis of LaNiO3 perovskite-type by chelating precursor method using EDTA and also was studied the optimization of the EDTA content in the synthesis. The synthesized materials were characterized by X-ray diffraction (XRD), thermal gravimetric analysis (TG) and Infrared Spectroscopy (FTIR). In the optimization of the EDTA content the lowest ratio of metal / EDTA used was 1.0 / 0.1, where it was possible to obtain monophasic perovskite.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In recent years there has been great progress in the field of nanotechnology largely driven by research into nanomaterials. Chemistry appears in this context for its relevant role in the synthesis and surface modification of nanomaterials. This review article discusses fundamental concepts related to the synthesis and properties of inorganic nanoparticles with diverse properties. Aspects related to unique size dependent optical and magnetic properties are discussed and the chemistry involved in the preparation of nanomaterials reviewed. Fundamental aspects of the chemical modification of nanoparticles envisaging potential applications for these materials are also addressed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes the synthesis and characterization of two new compounds with ligand opy (N-(2-pyridyl)oxamate): the copper(II) precursor [Me4N]2[Cu(opy)2].5H2O and CoII CuII coordination polymer {[CoCu(opy)2]}n×4nH2O. This latter compound was obtained by reaction of [Me4N]2[Cu(opy)2].5H2O and CoCl2.6H2O in water. The heterobimetallic CoII CuII chain was characterized by elemental analysis, IR spectroscopy, thermogravimetry and magnetic measurements. Magnetic characterization revealed typical behavior of one-dimensional (1D) ferrimagnetic chain as shown in the curves of temperature (T) dependence of magnetic susceptibility (χM), in the form of χMT versus T, and dependence of magnetization (M) with applied field (H).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, hydrotalcite, a layered double hydroxide, had its ion exchange properties combined with the magnetic properties of iron oxide to produce a magnetic adsorbent, HT-Fe 500. These magnetic composites can be used as adsorbents for anionic contaminants in water and subsequently removed from the medium by a simple magnetic process. Removal of chromium (VI) from aqueous solutions using HT-Fe 500 was achieved using batch adsorption experiments. The adsorption capacity, calculated with the Langmuir-Freundlich model showed to be dependent on temperature, reaching values of 25.93 and 48.31 mg g-1, respectively, for temperatures of 25 and 30 ºC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Synthesis, spectral identification, and magnetic properties of three complexes of Ni(II), Cu(II), and Zn(II) are described. All three compounds have the general formula [M(L)2(H2O)2], where L = deprotonated phenol in the Schiff base 2-((z)-(3-methylpyridin-2-yleimino)methyl)phenol. The three complexes were synthesized in a one-step synthesis and characterized by elemental analysis, Fourier transform infrared spectroscopy, electronic spectra, X-ray diffraction (XRD), and room temperature magnetic moments. The Cu(II) and Ni(II) complexes exhibited room temperature magnetic moments of 1.85 B.M. per copper atom and 2.96 B.M. per nickel atom. The X-band electron spin resonance spectra of a Cu(II) sample in dimethylformamide frozen at 77 K (liquid nitrogen temperature) showed a typical ΔMS = ± 1 transition. The complexes ([M(L)2(H2O)2]) were investigated by the cyclic voltammetry technique, which provided information regarding the electrochemical mechanism of redox behavior of the compounds. Thermal decomposition of the complexes at 750 ºC resulted in the formation of metal oxide nanoparticles. XRD analyses indicated that the nanoparticles had a high degree of crystallinity. The average sizes of the nanoparticles were found to be approximately 54.3, 30.1, and 44.4 nm for NiO, CuO, and ZnO, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This dissertation discusses Holocene palaeoenvironmental and palaeomagnetic secular variation (PSV) records reconstructed from sediments preserved in Lake Lehmilampi (63º37´N, 29º06´E) and Lake Kortejärvi (63º37´N, 28º56´E) in eastern Finland. Several piston and freeze cores were obtained from both lakes for varve and magnetic analyses. Sediment samples were impregnated in low-viscosity epoxy and physical parameters of varves, including varve thickness and relative grey-scale values, were recorded using x-ray densitometry combined with semiautomatic digital image analysis. On average, varve records of Lehmilampi and Kortejärvi cover 5122 and 3902 years, respectively. Past solar activity, as estimated by residual 14C data, compares favourably with varve thicknesses from Lehmilampi during the last 2000 years. This indicates the potential of clastic-organic varves to record sensitively climatic variations. Bulk magnetic parameters, including magnetic susceptibility together with natural, anhysteretic and isothermal remanent magnetizations, were measured to describe mineral magnetic properties and geomagnetic palaeosecular variation recorded in the sediments. Main stages in the development of the investigated lakes are reflected in the variations in the mineral magnetic records, sediment lithology and composition. Similar variations in magnetic parameters and sediment organic matter suggest contribution of bacterial magnetite in the magnetic assemblages of Lehmilampi. Inclination and relative declination records yielded largely consistent results, attesting to the great potential of these sediments to preserve directional palaeosecular variation in high resolution. The PSV data from Lehmilampi and Kortejärvi were stacked into North Karelian PSV stack, which may be used for dating homogenous lake sediments in the same regional context. Reconstructed millennial variations in relative palaeointensity results are approximately in agreement with those seen in the absolute palaeointensity data from Europe. Centennial variations in the relative palaeointensity, however, are influenced by environmental changes. Caution is recommended when using varved lake sediments in reconstructing relative palaeointensity.