948 resultados para Low signal-to-noise ratio regime
Resumo:
Handedness, as a potentially influencing, nonpathologic factor, has not been investigated in relation to transient evoked otoacoustic emissions (TEOAEs). The present study aimed to examine the effects of handedness on the TEOAE spectrum in entry-level schoolchildren, with attention also to possible ear asymmetry. A total of 228 subjects (114 males, 114 females, mean age = 6.3 years) were tested using the ILO292 Otodynamics Analyzer (Quickscreen mode) in quiet rooms in 22 schools. For statistical analysis, subjects were matched for factors such as handedness, gender, age, and history of recent ear infection. The results from subjects with passing TEOAE, pure-tone screening, and tympanometry revealed no significant handedness effect overall, although a significant ear asymmetry effect on the measurement parameters of AB difference, noise level, response level, whole-wave reproducibility, band reproducibility, and signal-to-noise ratios was found.
Resumo:
This study compares the performance of the Quickscreen and Default protocols of the ILO-96 Otodynamics Analyzer in recording transient evoked otoacoustic emissions (TEOAEs) from adults using clinical decision analysis. Data were collected from 25 males (mean age = 29.0 years, SD = 6.8) and 35 females (mean age = 28.1 years, SD = 9.6). The results showed that the mean signal-to-noise ratios obtained from the Quickscreen were significantly greater than those from the Default protocol at 1,2, and 4 kHz. The comparison of the performance of the two protocols, based on the results using receiver operating characteristics curves, revealed a higher performance of the Quickscreen than the Default protocol at 1 and 4 kHz but not at 2 kHz. In view of the enhanced performance of the Quickscreen over the Default protocol in general, the routine use of the Default protocol for testing adults in audiology clinics should be reconsidered.
Resumo:
O presente estudo avalia o efeito da cafeína no valor da razão contraste ruído (CNR) em imagens SWI. A população do estudo incluiu 24 voluntários saudáveis que estiveram pelo menos 24h privados da ingestão de cafeína. Adquiriram-se imagens SWI antes e após a ingestão de 100ml de café. Os voluntários foram divididos em 4 grupos de 6 indivíduos e avaliados sequencialmente (15, 25, 30 e 45 min pós-cafeína). ABSTRACT - The present study investigates the effect of caffeine on contrast-to-noise ratio (CNR) in SWI images. Twenty-four volunteers were enrolled in the study. All the volunteers were caffeine-free for 24h prior to the test. SWI images were acquired before caffeine ingestion and post-ingestion of 100ml of coffee. The volunteers were divided into four groups of subjects and evaluated sequentially (15, 25, 30 and 45 min after caffeine).
Resumo:
Susceptibility-weighted imaging (SWI) is a relatively new contrast in MR imaging. Previous studies have found an effect of caffeine in the contrast generated by SWI images. The present study investigates the effect of caffeine on contrast-to-noise ratio (CNR) in SWI.
Resumo:
Susceptibility Weighted Image (SWI) is a Magnetic Resonance Imaging (MRI) technique that combines high spatial resolution and sensitivity to provide magnetic susceptibility differences between tissues. It is extremely sensitive to venous blood due to its iron content of deoxyhemoglobin. The aim of this study was to evaluate, through the SWI technique, the differences in cerebral venous vasculature according to the variation of blood pressure values. 20 subjects divided in two groups (10 hypertensive and 10 normotensive patients) underwent a MRI system with a Siemens® scanner model Avanto of 1.5T using a synergy head coil (4 channels). The obtained sequences were T1w, T2w-FLAIR, T2* and SWI. The value of Contrast-to-Noise Ratio (CNR) was assessed in MinIP (Minimum Intensity Projection) and Magnitude images, through drawing free hand ROIs in venous structures: Superior Sagittal Sinus (SSS) Internal Cerebral Vein (ICV) and Sinus Confluence (SC). The obtained values were presented in descriptive statistics-quartiles and extremes diagrams. The results were compared between groups. CNR shown higher values for normotensive group in MinIP (108.89 ± 6.907) to ICV; (238.73 ± 18.556) to SC and (239.384 ± 52.303) to SSS. These values are bigger than images from Hypertensive group about 46 a.u. in average. Comparing the results of Magnitude and MinIP images, there were obtained lower CNR values for the hypertensive group. There were differences in the CNR values between both groups, being these values more expressive in the large vessels-SSS and SC. The SWI is a potential technique to evaluate and characterize the blood pressure variation in the studied vessels adding a physiological perspective to MRI and giving a new approach to the radiological vascular studies.
Resumo:
Signal-to-interference ratio (SIR) performance of a multiband orthogonal frequency division multiplexing ultra-wideband system with residual timing offset is investigated. To do so, an exact mathematical derivation of the SIR of this system is derived. It becomes obvious that, unlike a cyclic prefixing based system, a zero padding based system is sensitive to residual timing offset.
Resumo:
As the financial crisis hit the Portuguese banks, the profitability of the whole sector squeezed to historical minimums. Reinventing the banking business model in the post-crisis context is an overriding issue to achieve sustainable profits and a low cost-to-income ratio. We propose banks to adopt a true multichannel approach, proceeding to a branch network reformatting and a relocation of services to online channels; adopt a true customer-centric approach and reduce the product and services portfolio complexity; finally, industrialize operations and rationalize the structure. With these measures in place, Portuguese banks will become leaner and more efficient, aspiring to a cost-to-income ratio below 45%.
Resumo:
RESUMO: Os mais recentes métodos de neuro imagem tal como a Ressonância Magnética (RM) permitiram obter imagens detalhadas do cérebro humano in vivo. Essas imagens revelam, muitas vezes, achados imprevistos face ao padrão normal, com elevada propensão para os indivíduos idosos e franca coexistência com fatores de risco vascular, como característica dum processo de envelhecimento normal. Embora na última década tenham surgido várias publicações sobre este assunto, ele continua ainda pouco explicado. Um pouco por todo o mundo têm emergido os programas de prevenção da doença e promoção da saúde desenvolvidos pela Saúde Pública suportadas sobretudo pelo avanço das tecnologias médicas que resultaram, entre outros impactos, num crescimento da população idosa. Estima-se, em 2030, uma composição demográfica com 20% de indivíduos acima dos 65 anos. Neste contexto, a doença microvascular cerebral é a causa mais frequente de comprometimento cognitivo vascular no idoso sendo as características senescentes na imagem por RM do tipo lesões isquémicas da Substância Branca (Leukoaraiosis) e enfartes lacunares (Status lacunar), atrofia cerebral, gliose e acumulação excessiva de ferro nos núcleos da base. Esta tese, considerando a linha de investigação de que deriva – Ciências da Vida - especialização em Medicina Clinica - Biotecnologia, reúne e reflete sobre três vertentes ligadas à RM e interdependentes em relação a uma problemática comum. A primeira trata da caracterização da Tecnologia por Ressonância Magnética existente em Portugal, a qual inclui uma avaliação exploratória da aplicação da técnica de Difusão Anisotrópica nos estudos cerebrais. As dimensões analíticas estudadas foram a Tecnológica, Sociodemográfica e Económica. Na recolha de dados recorreu-se a várias fontes de informação e a uma metodologia exploratória faseada, validada pela triangulação dos resultados. A sua análise obedeceu a critérios de estratificação e agrupamento segundo as mesmas dimensões analíticas. Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular A segunda descreve o estudo anátomo – radiológico que recaiu sobre parâmetros de quantificação assente na temática do cérebro do idoso em cadáver segundo uma metodologia experimental aplicada às métricas da difusão por RM. Na terceira, e última, é apresentado o estudo técnico - radiológico para avaliação e otimização da imagem ponderada em difusão em estudos clínicos associados ao cérebro do idoso “The Usual Brain Aging” ou Envelhecimento Cerebral Normal, com base metodológica assente nos critérios e indicadores estabelecidos pelo Estudo de Imagem de Roterdão (Rotterdam Scan Study - RSS). Como principais resultados obteve-se que não existem em Portugal estruturas para avaliação dos equipamentos pesados ou Agência de Avaliação das Tecnologias da Saúde para desenvolver o importante papel da produção de estudos comparativos entre os equipamentos disponíveis no mercado, a relação preço-qualidade e a sua afetação às necessidades clínico-epidemiológicas. Constatou-se que a implementação de equipamentos de RM está fortemente assente em critérios económicos carecendo de recomendações e diretivas para o uso racionalizado destas tecnologias. Quanto a dados quantitativos concluímos que a maioria dos equipamentos está instalada em instituições privadas (80,2%); a intensidade de campo magnético mais frequente é [1,5T] com 119 equipamentos; os equipamentos estão instalados maioritariamente nos distritos de Lisboa (55 unidades) e do Porto (39 unidades); o rácio médio de equipamentos por habitante em Portugal é de 1 para 65 195 habitantes; a amplitude de gradientes com maior expressão na amostra é 30-39mT/m; a maioria dos equipamentos foi instalada no intervalo temporal [2009-2012] com 59 equipamentos; apenas 6 instituições desenvolvem investigação clinica e a maioria das bobinas para estudos de crânio são do tipo Array. O estudo de otimização da técnica da difusão revelou, quanto à avaliação dos valoresb, que os mais baixos (b=500 s/mm2 e b=1000 s/mm2), apresentam maior IS e SNR sendo esta uma boa medida referente à qualidade de imagem, no entanto, os valores-b mais elevados (b=2000 s/mm2) apresentam maior CNR e CR, face aos anteriores, o Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular que apesar de proporcionar inferior detalhe anatómico e consequentemente inferior qualidade de imagem, num encéfalo normal, pode auxiliar na interpretação e apresentar vantagens na identificação de lesões microvasculares sempre que persistirem dúvidas em relação ao diagnóstico diferencial de doença microvascular do tipo status lacunar ou Hiperintensidades da Substância Branca. As alterações deste parâmetro são particularmente refletidas nas diferenças da avaliação da qualidade de imagem na região fronto-calos Concluímos da avaliação quantitativa da concentração média de ferro (26Fe) em todas as faixas etárias que os núcleos da base que apresentam maior concentração são, por ordem decrescente: Substância Nigra, Globus Pallidus, Putamen, Tálamo, Núcleo Rubro e Núcleo Caudado; que existe uma predominância na concentração de ferro (26Fe) no hemisfério esquerdo e que os indivíduos do género masculino apresentam mais ferro (26Fe) que os do género feminino nas faixas etárias [30-40[, [40-50[ e [50-60[. Como principal conclusão do estudo da concentração média de ferro em relação à idade destacamos que a concentração média de ferro (26Fe) é superior nos grupos etários superiores, logo aumenta com a idade, sobretudo na Substância Nigra e no Núcleo Lenticular. No estudo técnico-radiológico encontrámos evidências do aumento da difusibilidade da água na substância branca subcortical dos sujeitos idosos comparativamente aos mais jovens. Uma relação idêntica foi avaliada nos tálamos. O aumento relacionado com a idade parece ser predominantemente observado em doentes com mais de 65 anos de idade o que pode refletir alterações estruturais ligeiras associados ao envelhecimento normal. Os resultados indicam que a análise quantitativa das imagens ponderadas em difusão fornece informações, sobre a estrutura do cérebro, as quai s não estão disponíveis apenas por inspeção visual, tanto nas imagens ponderadas em difusão como em outras sequências de aplicação clínica de rotina. Para fazer face às desvantagens dos sistemas de quantificação das HSB os quais são dispendiosos, complexos, requererem tecnologia e formação específicas, recomendamos que a aplicação automatizada GUIAL, desenvolvida ao longo do nosso trabalho é de utilização elementar e prática para que seja introduzida nos sistemas de aquisição de imagem por RM com o fim de integrar o processamento de imagem nos indivíduos portadores de fatores de risco vascular. A avaliação do ADC, nesta amostra, permitiu concluir que a variação desta variável é explicada estatisticamente pela existência da condição clínica de status lacunar em ambos os hemisférios ou por outras palavras, o status lacunar influencia o valor de ADC. Embora uma pequena percentagem da variação do ADC seja explicada pelo género, o ADC nos homens foi superior ao das mulheres o que não nos surpreende, pois são também os homens onde a frequência de doença microvascular se revelou mais expressiva. Os valores do ADC, globalmente, entre os hemisférios cerebrais não mostraram alterações exceto na SB entre os idosos e não idosos. A SB da região frontal mostrou valores diminuídos na anisotropia e isotropia face às restantes áreas anatómicas. Os estudos indicam que na idade avançada existe uma maior predisposição para suscetibilidades de estrutura com status de desconexão. A classificação das HSB foi superior em indivíduos mais velhos e com status lacunar, e em menor quantidade (inferior rating de classificação) nos indivíduos idosos sem status lacunar. As alterações volumétricas foram mais frequentes no homem do que na mulher, presumivelmente devido à associação com a elevada classificação de status lacunar. Um aumento do índice de Evan correspondeu, neste estudo, ao aumento das HSB, à diminuição do volume cerebral total, à expansão ventrículo-sulcal frontal e ao aumento da medida do ângulo caloso. Estes resultados foram agravados pela classificação elevada de status lacunar nos indivíduos que apresentaram indícios de doença de pequenos vasos, com manifesto aumento dos espaços de Virchow-Robin,enfartes lacunares ou HSB. Esses resultados foram mais expressivos no género masculino do que no feminino revelando uma maior vulnerabilidade sobretudo na atrofia frontal nos homens. Por sua vez as dimensões do Corpo Caloso tornaram-se reduzidas devido à compressão dos ventrículos laterais e terceiro ventrículo. Estes indicadores tiveram expressão particularmente nos indivíduos com mais de 65 anos. ---------------------------------------------------------------------------------------------ABSTRACT: The latest neuroimaging methods, such as Magnetic Resonance Imaging (MRI), have enabled detailed images of in vivo human brain. These images reveal often unexpected findings related to the normal pattern, with high predisposition for the elderly people with forthright coexistence with vascular risk factors such as characteristics of a normal aging process. Although it has been, in the last decade, several publications on this subject, it is still little explained. All over the world have emerged disease prevention programs and health promotion developed by the Public Health sector, supported mainly by the advancement of medical technologies that have resulted, among other impacts, in a growing of the elderly population. It is estimated, in 2030, a demographic composition with 20% o people over 65 years. In this context, microvascular disease is the most common cause of cognitive vascular impairment in the elderly and senescent characteristics in the MRI trough ischemic lesions of the white matter (Leukoaraiosis) and lacunar infarcts (lacunar status), cerebral atrophy, gliosis and iron accumulation in the basal ganglia in excess.This thesis, considering the research line that stems - Life Sciences - specialization in Clinical Medicine, Biotechnology, gathers and reflects on three aspects linked to MR, interdependent and related to a common problem. The first deals with the Magnetic Resonance Technology characterization in Portugal, which includes an exploratory evaluation of the implementation of Anisotropic Diffusion technique in brain studies. The analytical dimensions studied were the Technologic, Socio-demographic and Economics. Collecting data was supported by different sources of information and was applied an exploratory methodology whose results were validated by triangulation. The research method was grouped and stratified criteria under the same analytical dimensions. The second describes the anatomical study - which was focused on radiological measurement parameters, based on the brain’s specimen under an experimental methodology applied to MRI diffusion metrics. Radiological evaluation and optimization of the weighted image diffusion in clinical studies were associated with the brain of the elderly "The Usual Brain Aging" with methodological basis based on established criteria and indicators by Rotterdam Scan Study (RSS). The main results obtained reveal the inexistence frameworks in Portugal for evaluation of equipments or Agency of Health Technology to produce studies comparing the equipment available on the market, the value for money and its allocation to clinical and epidemiological needs. It was found that the implementation of MRI equipment is strongly based on economic criteria lacking recommendations and guidelines for the rationalized use of these technologies. As the quantitative data we conclude that most of the scanners are located in private clinical institutions (80,2%); the most frequent magnetic field intensity is [1.5T] with 119 scanners; the scanners are mainly installed in Lisbon (55 units) and Porto (39 units) districts; the average ratio of equipment per capita in Portugal is 1 to 65 195 people; the gradient power with higher expression in the sample is 30-39mT / m;most of the scanners were installed in the years range [2009-2012 years] with 59 equipment; only 6 clinical placements develop clinical research and the most coils for brain studies are of Array type. The optimization study of diffusion technique revealed, as the assessment of the bvalues, the lower (b = 500 s / mm2 and b = 1000 s / mm 2), promotes an increase in the SI and SNR being this measure related to a higher image quality, however the highest b values (b = 2000 s / mm 2) have a higher CNR (Contrast to Noise-Ratio) and CR (Contrast Ratio), compared to the previous ones. This may provide less anatomical details and, thus, ower image quality, of a normal brain, however can help the interpretation and have advantages in identifying microvascular injuries when doubts persist regarding the differential diagnosis of microvascular disease of lacunar or WMH (White Matter Hyperintensities) status type. Changes on this parameter are Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular particularly reflected in the differences of image quality evaluation in the frontocallosum anatomical area. We conclude from the quantitative assessment of the average concentration of iron (26Fe), in all age groups to the basal ganglia, that the higher concentrations are, in descending order: Nigral Substantia, Globus pallidus, Putamen, Thalamus, Rubio nucleus and Caudate nucleus; that there is a predominance in the concentration of iron (26Fe) in the left hemisphere and that male gender show higher iron (26Fe) level tha females, in the age groups [30-40 [[40-50 [and [50- 60 [. Regarding a main conclusion of the mean concentration study of iron, in terms of age we point out that the average concentration of iron (26Fe) is higher among older groups and increases with age, especially in Nigral Substantia and Lenticular Nucleus. On the technical and radiological study we found evidence of an increased in water /diffusivity in the ubcortical white matter of the elderly compared with younger subjects. A similar relationship was assessed in the Thalamus. The increase agerelated seems to be predominantly observed in patients over 65 years which may reflect minor structural changes associated with normal aging. The results indicate that quantitative analysis of diffusion weighted imaging can provide information about the structure of the brain which is not reached only by visual inspection or standard sequences applied in clinical routine. To address the disadvantages the systems of quantification of WMH which the authors state that are costly, complex, require specific technology and training, we recommend that the automated application GUIAL, developed over our work is basic and practical to use and to be introduced in MR image systems acquisition in order to integrate image processing in patients with vascular risk factors. The evaluation of the ADC showed that its variation is statistically explained by the existence of the medical condition of lacunar status, in both hemispheres, or in other words, the lacunar status influences the ADC value. Although a small percentage of the ADC variation is explained by gender, the ADC in men was higher than women which Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular do not surprise us, since they are also men where the frequency of microvasculardisease has proved more significant. The values of ADC, overall, between the cerebral hemispheres showed no changes but were different in WM among the elderly and non-elderly subjects.The WM's forehead showed decreased values in anisotropy and isotropy face the other anatomical areas. The studies indicate that in old age there is a greater tendency to higher susceptibility to disconnection- status framework. The classification of WMH was higher in elderly people and lacunar status, and fewer (lower classification rating) in the elderly without lacunar status. volumetric changes were more frequent in men than in women, most probably because of its association with high lacunar status rating. An increase of Evan index corresponded, in this study, to an increase in WMH, to a decreased of total brain volume, to a ventricle sulcal frontal and callous angle expansion. These results were wound up by high ranking of lacunar status in subjects who had small vessel disease, clear increase in spaces of Virchow-Robin, lacunar infarctions or WMH. These results were more significant in males than in females revealing vulnerability particularly in the frontal atrophy in men. In turn the size of Corpus Callosum because reduced due to the compression of the lateral and third ventricles. These indicators had expression particularly in individuals over 65 years.
Resumo:
In the Brazilian Amazon, large areas of abandoned lands may revert to secondary forest. In the process, pioneer tree species have an important role to restore productivity in old fields and improve environmental conditions. To determine potential photosynthesis (Apot), stomatal conductance (g), transpiration (E), and leaf micronutrient concentrations in Ochroma pyramidale (Cav. ex Lam.) Urban a study was carried out in the Brazilian Amazon (01o 51' S; 60o 04' W). Photosynthetic parameters were measured at increasing [CO2], saturating light intensity (1 mmol (photons) m-2 s-1), and ambient temperature. The rate of electron-transport (J), Apot,and water-use efficiency (WUE) increased consistently at increasing internal CO2 concentration (Ci). Conversely, increasing [CO2] decreased gs, E, and photorespiration (Pr). At the CO2-saturated region of the CO2 response curve (1.1 mmol (CO2) mol-1(air), J was 120 μmol (e-) m-2s-1 and Apot reached up to 24 μmol (CO2) m-2s-1. Likewise, at saturating C1 g and E were 30 and 1.4 mmol (H2O) m-2s-1, respectively, and P 2 r about 1.5 μmol (CO2) m-2s-1. Foliar nutrients were 185, 134, 50, and 10 μmol (element) m-2 (leaf area) for Fe, Mn, Zn, and Cu, respectively. It was concluded that [CO ] probably limits light saturated photosynthesis in this site. Furthermore, from a nutritional point of view, the low Fe to Cu ratio (15:1) may reflect nutritional imbalance in O. pyramidale at this site.
Resumo:
A measurement is presented of the tt¯ inclusive production cross section in pp collisions at a center-of-mass energy of s√=8 TeV using data collected by the ATLAS detector at the CERN Large Hadron Collider. The measurement was performed in the lepton+jets final state using a data set corresponding to an integrated luminosity of 20.3 fb−1. The cross section was obtained using a likelihood discriminant fit and b-jet identification was used to improve the signal-to-background ratio. The inclusive tt¯ production cross section was measured to be 260±1(stat)+22−23(stat)±8(lumi)±4(beam) pb assuming a top-quark mass of 172.5 GeV, in good agreement with the theoretical prediction of 253+13−15 pb. The tt¯→(e,μ)+jets production cross section in the fiducial region determined by the detector acceptance is also reported.
Resumo:
OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.
Resumo:
When speech is degraded, word report is higher for semantically coherent sentences (e.g., her new skirt was made of denim) than for anomalous sentences (e.g., her good slope was done in carrot). Such increased intelligibility is often described as resulting from "top-down" processes, reflecting an assumption that higher-level (semantic) neural processes support lower-level (perceptual) mechanisms. We used time-resolved sparse fMRI to test for top-down neural mechanisms, measuring activity while participants heard coherent and anomalous sentences presented in speech envelope/spectrum noise at varying signal-to-noise ratios (SNR). The timing of BOLD responses to more intelligible speech provides evidence of hierarchical organization, with earlier responses in peri-auditory regions of the posterior superior temporal gyrus than in more distant temporal and frontal regions. Despite Sentence content × SNR interactions in the superior temporal gyrus, prefrontal regions respond after auditory/perceptual regions. Although we cannot rule out top-down effects, this pattern is more compatible with a purely feedforward or bottom-up account, in which the results of lower-level perceptual processing are passed to inferior frontal regions. Behavioral and neural evidence that sentence content influences perception of degraded speech does not necessarily imply "top-down" neural processes.
Resumo:
BACKGROUND: To test the hypothesis that intervals with superior beat-to-beat coronary artery repositioning precision exist in the cardiac cycle, to design a coronary MR angiography (MRA) methodology in response, and to ascertain its performance. METHODS: Coronary repositioning precision in consecutive heartbeats was measured on x-ray coronary angiograms of 17 patients and periods with the highest repositioning precision were identified. In response, the temporal order of coronary MRA pulse sequence elements required modification and the T2 -prep now follows (T2 -post) rather than precedes the imaging part of the sequence. The performance of T2 -post was quantitatively compared (signal-to-noise [SNR], contrast-to-noise [CNR], vessel sharpness) to that of T2 -prep in vivo. RESULTS: Coronary repositioning precision is <1 mm at peak systole and in mid diastole. When comparing systolic T2 -post to diastolic T2 -prep, CNR and vessel sharpness remained unchanged (both P = NS) but SNR for muscle and blood increased by 104% and 36% (both P < 0.05), respectively. CONCLUSION: Windows with improved coronary repositioning precision exist in the cardiac cycle: one in peak systole and one in mid diastole. Peak-systolic imaging necessitates a re-design of conventional coronary MRA pulse sequences and leads to image quality very similar to that of conventional mid-diastolic data acquisition but improved SNR. J. Magn. Reson. Imaging 2015;41:1251-1258. © 2014 Wiley Periodicals, Inc.
Resumo:
The large spatial inhomogeneity in transmit B, field (B-1(+)) observable in human MR images at hi h static magnetic fields (B-0) severely impairs image quality. To overcome this effect in brain T-1-weighted images the, MPRAGE sequence was modified to generate two different images at different inversion times MP2RAGE By combining the two images in a novel fashion, it was possible to create T-1-weigthed images where the result image was free of proton density contrast, T-2* contrast, reception bias field, and, to first order transmit field inhomogeneity. MP2RAGE sequence parameters were optimized using Bloch equations to maximize contrast-to-noise ratio per unit of time between brain tissues and minimize the effect of B-1(+) variations through space. Images of high anatomical quality and excellent brain tissue differentiation suitable for applications such as segmentation and voxel-based morphometry were obtained at 3 and 7 T. From such T-1-weighted images, acquired within 12 min, high-resolution 3D T-1 maps were routinely calculated at 7 T with sub-millimeter voxel resolution (0.65-0.85 mm isotropic). T-1 maps were validated in phantom experiments. In humans, the T, values obtained at 7 T were 1.15 +/- 0.06 s for white matter (WM) and 1.92 +/- 0.16 s for grey matter (GM), in good agreement with literature values obtained at lower spatial resolution. At 3 T, where whole-brain acquisitions with 1 mm isotropic voxels were acquired in 8 min the T-1 values obtained (0.81 +/- 0.03 S for WM and 1.35 +/- 0.05 for GM) were once again found to be in very good agreement with values in the literature. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.