951 resultados para Logical Correction
Resumo:
Computer modelling has shown that electrical characteristics of individual pixels may be extracted from within multiple-frequency electrical impedance tomography (MFEIT) images formed using a reference data set obtained from a purely resistive, homogeneous medium. In some applications it is desirable to extract the electrical characteristics of individual pixels from images where a purely resistive, homogeneous reference data set is not available. One such application of the technique of MFEIT is to allow the acquisition of in vivo images using reference data sets obtained from a non-homogeneous medium with a reactive component. However, the reactive component of the reference data set introduces difficulties with the extraction of the true electrical characteristics from the image pixels. This study was a preliminary investigation of a technique to extract electrical parameters from multifrequency images when the reference data set has a reactive component. Unlike the situation in which a homogenous, resistive data set is available, it is not possible to obtain the impedance and phase information directly from the image pixel values of the MFEIT images data set, as the phase of the reactive reference is not known. The method reported here to extract the electrical characteristics (the Cole-Cole plot) initially assumes that this phase angle is zero. With this assumption, an impedance spectrum can be directly extracted from the image set. To obtain the true Cole-Cole plot a correction must be applied to account for the inherent rotation of the extracted impedance spectrum about the origin, which is a result of the assumption. This work shows that the angle of rotation associated with the reactive component of the reference data set may be determined using a priori knowledge of the distribution of frequencies of the Cole-Cole plot. Using this angle of rotation, the true Cole-Cole plot can be obtained from the impedance spectrum extracted from the MFEIT image data set. The method was investigated using simulated data, both with and without noise, and also for image data obtained in vitro. The in vitro studies involved 32 logarithmically spaced frequencies from 4 kHz up to 1 MHz and demonstrated that differences between the true characteristics and those of the impedance spectrum were reduced significantly after application of the correction technique. The differences between the extracted parameters and the true values prior to correction were in the range from 16% to 70%. Following application of the correction technique the differences were reduced to less than 5%. The parameters obtained from the Cole-Cole plot may be useful as a characterization of the nature and health of the imaged tissues.
Resumo:
The small sample performance of Granger causality tests under different model dimensions, degree of cointegration, direction of causality, and system stability are presented. Two tests based on maximum likelihood estimation of error-correction models (LR and WALD) are compared to a Wald test based on multivariate least squares estimation of a modified VAR (MWALD). In large samples all test statistics perform well in terms of size and power. For smaller samples, the LR and WALD tests perform better than the MWALD test. Overall, the LR test outperforms the other two in terms of size and power in small samples.
Resumo:
Radiation dose calculations in nuclear medicine depend on quantification of activity via planar and/or tomographic imaging methods. However, both methods have inherent limitations, and the accuracy of activity estimates varies with object size, background levels, and other variables. The goal of this study was to evaluate the limitations of quantitative imaging with planar and single photon emission computed tomography (SPECT) approaches, with a focus on activity quantification for use in calculating absorbed dose estimates for normal organs and tumors. To do this we studied a series of phantoms of varying complexity of geometry, with three radionuclides whose decay schemes varied from simple to complex. Four aqueous concentrations of (99m)Tc, (131)I, and (111)In (74, 185, 370, and 740 kBq mL(-1)) were placed in spheres of four different sizes in a water-filled phantom, with three different levels of activity in the surrounding water. Planar and SPECT images of the phantoms were obtained on a modern SPECT/computed tomography (CT) system. These radionuclides and concentration/background studies were repeated using a cardiac phantom and a modified torso phantom with liver and ""tumor"" regions containing the radionuclide concentrations and with the same varying background levels. Planar quantification was performed using the geometric mean approach, with attenuation correction (AC), and with and without scatter corrections (SC and NSC). SPECT images were reconstructed using attenuation maps (AM) for AC; scatter windows were used to perform SC during image reconstruction. For spherical sources with corrected data, good accuracy was observed (generally within +/- 10% of known values) for the largest sphere (11.5 mL) and for both planar and SPECT methods with (99m)Tc and (131)I, but were poorest and deviated from known values for smaller objects, most notably for (111)In. SPECT quantification was affected by the partial volume effect in smaller objects and generally showed larger errors than the planar results in these cases for all radionuclides. For the cardiac phantom, results were the most accurate of all of the experiments for all radionuclides. Background subtraction was an important factor influencing these results. The contribution of scattered photons was important in quantification with (131)I; if scatter was not accounted for, activity tended to be overestimated using planar quantification methods. For the torso phantom experiments, results show a clear underestimation of activity when compared to previous experiment with spherical sources for all radionuclides. Despite some variations that were observed as the level of background increased, the SPECT results were more consistent across different activity concentrations. Planar or SPECT quantification on state-of-the-art gamma cameras with appropriate quantitative processing can provide accuracies of better than 10% for large objects and modest target-to-background concentrations; however when smaller objects are used, in the presence of higher background, and for nuclides with more complex decay schemes, SPECT quantification methods generally produce better results. Health Phys. 99(5):688-701; 2010
Resumo:
We propose two quantum error-correction schemes which increase the maximum storage time for qubits in a system of cold-trapped ions, using a minimal number of ancillary qubits. Both schemes consider only the errors introduced by the decoherence due to spontaneous emission from the upper levels of the ions. Continuous monitoring of the ion fluorescence is used in conjunction with selective coherent feedback to eliminate these errors immediately following spontaneous emission events.
Resumo:
Annular pancreas is a rare congenital anomaly, which is only surgically treated in symptomatic cases. Surgical treatment consists of bypassing the duodenal transit by gastrojejunal or duodenal-jejunal anastomosis. In the absolute majority of published cases, laparotomy is the most widely used access technique. The aim of this article is to report a case of an annular pancreas and describe the technical steps involved in carrying out a laparoscopic duodenal-jejunal anastomosis, for correction of the duodenal obstruction. The patient`s recovery was uneventful; she was discharged on the fourth postoperative day and remained asymptomatic for the 2-year, outpatient follow-up period. Laparoscopic duodenal-jejunal bypass is shown to be feasible and safe, and produce less surgical trauma, when carried out by an experienced surgeon who is duly trained and familiar with the laparoscopic technique.
Resumo:
OBJECTIVE: We introduce a technique for performing a selective amygdalohippocampectomy (AH) through a minisupraorbital approach. METHODS: A minisupraorbital craniotomy and an anterior selective AH were performed in 8 cadaver heads (16 sides). The anatomic specimens were analyzed, and the extent of resection of the hippocampus and amygdala was evaluated. Surgically relevant measurements were performed using anatomic specimens. An image-guided system was used to document the extent of the anterior AH. Laboratory data were used to support the clinical application of the technique. RESULTS: The anterior route allowed removal of the amygdala and hippocampus, as confirmed by anatomic assessment. The image-guided system and anatomic evaluation confirmed that the amygdala and hippocampus can be accessed and removed through this route. The mean distance between the anterior aspect of the uncus and the tip of the temporal horn was 17.0 +/- 4.6 mm; the mean distance from the head of the hippocampus to the posterior border of the cerebral peduncles was 26.0 +/- 3.2 mm. Clinical application resulted in satisfactory removal of the amygdala and hippocampus. CONCLUSION: The anterior route for selective AH is a logical and straightforward approach to the mesial temporal lobe. Compared with other variations, it is less invasive and destructive, especially in terms of the fibers of the optic pathway, temporal stem, and lateral temporal neocortex.
Resumo:
OBJECTIVE: Perforating arteries are commonly involved during the surgical dissection and clipping of intracranial aneurysms. Occlusion of perforating arteries is responsible for ischemic infarction and poor outcome. The goal of this study is to describe the usefulness of near-infrared indocyanine green videoangiography (ICGA) for the intraoperative assessment of blood flow in perforating arteries that are visible in the surgical field during clipping of intracranial aneurysms. In addition, we analyzed the incidence of perforating vessels involved during the aneurysm surgery and the incidence of ischemic infarct caused by compromised small arteries. METHODS: Sixty patients with 64 aneurysms were surgically treated and prospectively included in this study. Intraoperative ICGA was performed using a surgical microscope (Carl Zeiss Co., Oberkochen, Germany) with integrated ICGA technology. The presence and involvement of perforating arteries were analyzed in the microsurgical field during surgical dissection and clip application. Assessment of vascular patency after clipping was also investigated. Only those small arteries that were not visible on preoperative digital subtraction angiography were considered for analysis. RESULTS: The ICGA was able to visualize flow in all patients in whom perforating vessels were found in the microscope field. Among 36 patients whose perforating vessels were visible on ICGA, 11 (30%) presented a close relation between the aneurysm and perforating arteries. In one (9%) of these 11 patients, ICGA showed occlusion of a P1 perforating artery after clip application, which led to immediate correction of the clip confirmed by immediate reestablishment of flow visible with ICGA without clinical consequences. Four patients (6.7%) presented with postoperative perforating artery infarct, three of whom had perforating arteries that were not visible or distant from the aneurysm. CONCLUSION: The involvement of perforating arteries during clip application for aneurysm occlusion is a usual finding. Intraoperative ICGA may provide visual information with regard to the patency of these small vessels.
Resumo:
Objective: To estimate the prevalence of blindness in the elderly population of Campinas, Brazil, and to describe the coverage and quality of cataract surgery services in the area. Methods: A brief assessment of cataract surgery services (using the RACSS (Rapid Assessment of Cataract Surgical Services Method) was conducted using random cluster sampling, with a sample composed of 60 clusters of 40 people aged 50 years or older. Visual acuity (VA) was measured and the lens status observed by direct visual ophthalmoscopy. From the selected sample of 2,400 subjects, 92.67% were examined. Results: Blindness (VA 3/60 with available correction) was found in 1.98 % (2.03 % among male subjects, and 1.94 % among female subjects). The prevalence of blindness varied with age, from 0.2%, in the group from 50 to 54 years, to 7.2% in those above 80. Cataract was the main cause of blindness (40.2%) followed by suspected posterior segment disorders (18.2%), diabetic retinopathy (15.9%), and glaucoma (11.4%). The cataract surgical coverage was of 93% (VA 3/60) and 82.18% when the criterion was VA 6/60 in the best eye. The main reasons the subjects did not receive surgical treatment were: fear of undergoing surgery, 11.1%; lack of awareness about the condition, 16.7%; waiting for maturity, 16.7%; and contraindication to surgery, 44.4%. Conclusion: Cataract is the major cause of blindness in Campinas. Education on eye diseases, their prevention and treatment must become part of the city`s public healthcare policies.
Resumo:
Toxoplasma gondii causes severe disease both to man and livestock and its detection in meat after slaughtering requires PCR or biological tests. Meat packages contain retained exudate that could be used for serology due to its blood content. Similar studies reported false negative assays in those tests. We standardized an anti-T. gondii IgG ELISA in muscle juices from experimentally infected rabbits, with blood content determination by cyanhemoglobin spectrophotometry. IgG titers and immunoblotting profiles were similar in blood, serum or meat juice, after blood content correction. These assays were adequate regardless of the storage time up to 120 days or freeze-thaw cycles, without false negative results. We also found 1.35% (1/74) positive sample in commercial Brazilian rabbit meat cuts, by this assay. The blood content determination shows ELISA of meat juice may be useful for quality control for toxoplasmosis monitoring. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Congenital sternal cleft is a rare disease, and primary repair in the neonatal period is its best management. In 1998 we presented three surgical techniques for sternal cleft correction, but since 1999 we have elected one of them as our procedure of choice. Our latest results are now presented. It is a review of 15 patients operated from October 1979 to December 2007. Surgical repair consisted of 3 sliding chondrotomies, 10 reconstructions basec on a `posterior sternal wall`, 1 reconstruction combined to Ravitch operation for pectus excavatum and 1 associated with total repair of Cantrell`s pentalogy. Data concerning epidemiological features, surgical reconstruction, aesthetic results, postoperative major complications, mortality and hospital stay, were collected from hospital charts. Follow-up ranged from 4 months to 27 years. All patients submitted to surgical, correction had a good aesthetic and functional result. Neither postoperative mortality nor major complication was observed. Two patients had subcutaneous fluid collection that prolonged the drainage duration. The mean hospital stay was 6 days. In conclusion, reconstructing sterna. cleft with a `posterior periosteal flap from sternal bars and chondral graft` is an effective option with good aesthetic and long-term functional results. (C) 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND: One of the key elements for a successful endoscopic intervention in the ventricular system is the ability to recognize the anatomic structures and use them as a reference. OBJECTIVE: To measure the choroid plexus with endoscopy in the interventricular foramen, together with the structures on the third ventricle floor, and to compare these variables. METHODS: An observational prospective study was carried out on 37 brains of cadavers for which the cause of death was assessed at the Death Check Unit of the University of Sao Paulo in April 2008. This study was done on adults of both sexes with a rigid neuroendoscope. Endoscopic images were recorded, submitted for correction of distortion, and then measured. RESULTS: The measurements of the choroid plexus in the interventricular foramen, laterolateral distance of mammillary bodies, distance from the infundibular recess to the mammillary bodies, and area of the triangle in the tuber cinereum were 1.71 +/- 0.77 mm, 2.23 +/- 0.74 mm, 3.22 +/- 0.82 mm, and 3.69 +/- 2.09 mm(2), respectively. The ventricle floor was opaque in 84% of cases. The internal distance of mammillary bodies was absent in 89%. Associations between the translucent floor of the third ventricle and laterolateral distance of mammillary bodies, internal distance of mammillary bodies, and age were identified. CONCLUSION: Before this research, there was no record of the measurements of the choroid plexus in the interventricular foramen. The remaining variables of the present study show a greater number in normal brains compared with others.
Resumo:
Purpose: The aim of this study was to characterize the first 48-hour evolution of metabolic acidosis of adult patients with diabetic ketoacidosis admitted to the intensive care unit. Materials and Methods: We studied 9 patients retrieved from our prospective collected database, using the physicochemical approach to acid-base disturbances. Results: Mean (SD) age was 34 (13) years; mean (SD) Acute Physiology and Chronic Health Evaluation II score was 16 (10); mean (SD) blood glucose level on admission was 480 (144) mg/dL; mean (SD) pH was 7.17 (0.18); and mean (SD) standard base excess was -16.8 (7.7) mEq/L. On admission, a great part of metabolic acidosis was attributed to unmeasured anions (strong ion gap [SIG], 20 +/- 10 mEq/L), with a wide range of strong ion difference (41 +/- 10 mEq/L). During the first 48 hours of treatment, 297 +/- 180 IU of insulin and 9240 +/- 6505 mL of fluids were used. Metabolic improvement was marked by the normalization of pH, partial correction of standard base excess, and a reduction of hyperglycemia. There was a significant improvement of SIG (7.6 +/- 6.2 mEq/L) and a worsening of strong ion difference acidosis (36 +/- 5 mEq/L) in the first 24 hours, with a trend toward recuperation between 24 and 48 hours (38 +/- 6 mEq/L). Conclusion: Initial metabolic acidosis was due to SIG, and the treatment was associated with a significant decrease of SIG with an elevation of serum chloride above the normal range. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Purpose: To evaluate the use of orbital polyacrylamide gel injection for the correction of anophthalmic enophthalmos. Methods: Noncontrolled clinical trial of 21 patients (14 with ocular implants, 5 with phthisis bulbi, and 2 with dermis-fat graft). Orbital CT was performed to estimate the volume of polyacrylamide gel needed to restore orbital volume. Polyacrylamide gel was injected using a 22-gauge (30 x 0.7 min) needle transcutaneously inserted in the lateral third of the lower eyelid, directed to the orbital muscle cone. A second injection was administered 15 days later. if necessary. CT was repeated 30 days after the last procedure. Exophthalmometry was performed before Bind 90 days after file procedure. Results: The mean total volume injected per orbit was 2.4 +/- 0.7 ml (range 1-3.5 ml). The volume of the enophthalmic orbit increased front 26.9 +/- 5.0 ml to 29.3 +/- 4.9 ml (p < 0.001). The mean difference in exophthalmometry readings was 3.3 +/- 1.6 mm (range, 1.5-8.0 mm) before the procedure and 1.0 +/- 0.9 mm (range, 0.0-3.0 mm) after 3 months (p < 0.001). Adjustment of the ocular prosthesis or fabrication of a new one was necessary in 11 patients (52.4%), and the mean volume of the ocular prosthesis was reduced front 2.0 +/- 0.6 ml to 1.6 +/- 0.6 ml (p = 0.003). All patients were satisfied with the aesthetic results. No serious adverse events were observed. The initial results were maintained 1 year after the procedure. Conclusions: Polyacrylamide gel injection in the orbital space effectively reduces enophthalmos in ocular prosthesis wearers.
Resumo:
Introduction: The ACCM/PALS guidelines address early correction of paediatric septic shock using conventional measures. In the evolution of these recommendations, indirect measures of the balance between systemic oxygen delivery and demands using central venous or superior vena cava oxygen saturation ( ScvO(2) >= 70%) in a goal-directed approach have been added. However, while these additional goal-directed endpoints are based on evidence-based adult studies, the extrapolation to the paediatric patient remains unvalidated. Objective: The purpose of this study was to compare treatment according to ACCM/PALS guidelines, performed with and without ScvO(2) goal-directed therapy, on the morbidity and mortality rate of children with severe sepsis and septic shock. Design, participants and interventions: Children and adolescents with severe sepsis or fluid-refractory septic shock were randomly assigned to ACCM/PALS with or without ScvO(2) goal-directed resuscitation. Measurements: Twenty-eight-day mortality was the primary endpoint. Results: Of the 102 enrolled patients, 51 received ACCM/PALS with ScvO(2) goal-directed therapy and 51 received ACCM/PALS without ScvO(2) goal-directed therapy. ScvO(2) goal-directed therapy resulted in less mortality ( 28-day mortality 11.8% vs. 39.2%, p = 0.002), and fewer new organ dysfunctions ( p = 0.03). ScvO(2) goal-directed therapy resulted in more crystalloid ( 28 ( 20-40) vs. 5 ( 0-20) ml/kg, p < 0.0001), blood transfusion ( 45.1% vs. 15.7%, p = 0.002) and inotropic ( 29.4% vs. 7.8%, p = 0.01) support in the first 6 h. Conclusions: This study supports the current ACCM/PALS guidelines. Goal-directed therapy using the endpoint of a ScvO(2) = 70% has a significant and additive impact on the outcome of children and adolescents with septic shock.
Resumo:
Objective: To develop a new endoscopic approach to the correction of a myelomeningocele-like defect in fetal sheep. Methods: The fetuses of 9 pregnant ewes, with an average gestational age of 115 days, were subjected to a 3.0 x 2.0 cm removal of the skin over the lumbar spine, performed through hysterotomy. The uterus was closed, and three 5-mm endoscopic cannulas, without valve mechanisms, were inserted. In the pilot phase (2 animals), we initially worked exclusively in the amniotic fluid space. In the study phase, we partially withdrew the fetus from the amniotic fluid to completely expose its back. By simply allowing air to enter the amniotic cavity (without gas injection), a working space was created using a uterine lift device. The skin around the defect was dissected, and a biosynthetic cellulose material was applied to cover the area. A continuous suture of the skin was performed to completely hide the material. Results: The combined air/fluid space allowed the skin to be successfully closed in 6 out of 7 cases in the study phase. All fetuses were alive at the end of the procedures. Time to complete the endoscopic part of the procedure fell from 3 to 1 h by the end of this series. Premature birth occurred in 2 of the 4 cases allowed to continue with the pregnancy. Conclusion: A new gasless fetoscopic surgery technique was developed as an alternative to current techniques used for fetal endoscopic surgery. Copyright (C) 2008 S. Karger AG, Basel.