914 resultados para Level effect


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present research was undertaken to explore the influence of fructooligosaccharides (FOS) on the functional and thermal properties of sour cassava starch and the quality characteristics of gluten-free (GF) cheese bread. Fructooligosaccharides were used to replace sour cassava starch at substitution level of 9% (SF1), 17% (SF2), and 29% (SF3). The functional and thermal properties of the starch-FOS mixtures were determined by the water absorption index (WAI), water solubility index (WSI), pasting profile analysis, thermal transition temperatures and enthalpy of gelatinization. Moreover, the GF cheese breads with starch-FOS mixtures were analyzed for height, diameter, weight, specific volume and dough moisture content. The sample with the highest FOS content (SF3) presented the lowest WAI (1.44), peak (62.4 rapid visco units (RVU), breakdown (53.4 RVU), final (13.8 RVU), and setback (4.9 RVU) viscosities, dough moisture content (31.7%), and enthalpy of gelatinization (9.5 J/g) and the highest WSI (29.4%) and pasting temperature (69.1 degrees C). The height, diameter and specific volume of GF cheese bread samples made from sour cassava starch were 3.14 cm, 6.35 cm, and 1.49 cm(3)/g, respectively. The SF1 mixture samples resulted in a 3.01 cm height, 6.34 cm diameter, and 1.55 cm(3)/g specific volume. According to Brazilian food labeling regulations, the latter product cannot be categorized as a good source of fiber because the minimum level of fiber per portion was not reached.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The process of spermatic division and differentiation (spermatogenesis) occurs with intratesticular temperature lower that the corporal temperature and for that is essential that the testicular thermoregulation mechanism occurs properly. For evaluation of the scrotal surface temperature can be used the infrared thermography or testicular sensors, besides that, can be evaluated the blood flux in the spermatic cord through the Doppler ultrasonography. Thus, the aim of this study is to analyze the testicular thermoregulation in adult buffaloes through scrotal thermography and Doppler ultrasound of testicular artery and verify its effect on sperm quality. For that were used seven healthy buffaloes, with age of 3 and 4 years, of the Murrah breed. The animals were subjected to 3 semen collections using artificial vagina, with one day of interval. In addiction, the retal temperature measurement (RT) with dry bulb thermometer, the measurement of scrotal surface temperature (SST) and body surface temperature (BST) through infrared thermography and the pulsatility (PI) and resistivity (RI) index of testicular artery by Doppler ultrasonography, were performed using 2 distinct moments: animals previously placed to shade (M1) and animals subjected to 4 hours of sun (M2). All parameters were compared by T test and the correlations were performed by Pearson test using the In Stat Graph Pad 3 (R) program. The significant level considered was 5%. There was an increase (p<0,05) of RT, SST, SNT and RI in M2. increasing trend was observed (0,05>p>0,01) PI and RI between M1 and M2. There was a low correlation between SST and semen quality. The results of this study allow us to conclude that adult buffaloes have low ability to perform body and testicular thermoregulation in situations of enviromental heat stress. However, this low capacity of testicular temperature maintenance demonstrated no correlation with the sperm kinetic parameters and sperm morphological defects in buffalo spermatozoa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate and compare the reliability of implant-supported single crowns cemented onto abutments retained with coated (C) or noncoated (NC) screws and onto platform-switched abutments with coated screws. Materials and Methods: Fifty-four implants (DT Implant 4-mm Standard Platform, Intra-Lock International) were divided into three groups (n = 18 each) as follows: matching-platform abutments secured with noncoated abutment screws (MNC); matching-platform abutments tightened with coated abutment screws (MC); and switched-platform abutments secured with coated abutment screws (SC). Screws were characterized by scanning electron microscopy and x-ray photoelectron spectroscopy (XPS). The specimens were subjected to step-stress accelerated life testing. Use-level probability Weibull curves and reliability for 100,000 cycles at 200 N and 300 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used for fractographic analysis. Results: Scanning electron microscopy revealed differences in surface texture; noncoated screws presented the typical machining grooves texture, whereas coated screws presented a plastically deformed surface layer. XPS revealed the same base components for both screws, with the exception of higher degrees of silicon in the SiO2 form for the coated samples. For 100,000 cycles at 300 N, reliability values were 0.06 (0.01 to 0.16), 0.25 (0.09 to 0.45), and 0.25 (0.08 to 0.45), for MNC, MC, and SC, respectively. The most common failure mechanism for MNC was fracture of the abutment screw, followed by bending, or its fracture, along with fracture of the abutment or implant. Coated abutment screws most commonly fractured along with the abutment, irrespective of abutment type. Conclusion: Reliability was higher for both groups with the coated screw than with the uncoated screw. Failure modes differed between coated and uncoated groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study was carried out to evaluate the effect of statins associated with physical exercise (PE) in liver cells in dyslipidemic rats through cariometry. The animals were divided into six groups: animals subjected to a hypercholesterolemic diet (HD), simvastatin, with (G1) and without (G2) physical exercise (PE); HD submitted (G3) or not (G4) to PE, and commercial food diet (F) with (G5) and without (G6) PE. Histological analysis of the liver was performed by staining the slides with hematoxylin and eosin. The cariometric study included measuring the major and minor diameters of the hepatocytes nuclei. The Shapiro-Wilk test was also performed. To determine the differences among the groups, the Kruskal-Wallis Test with Dunn's post-test were conducted. The significance level was set at 5%. No difference was found in the hepatocytes nuclei between G5 and G6. When these groups were related with G3 and G4, reduced nuclei were observed. There was no difference between G1 and G6. The comparison between G6 and G2 showed that the nuclei in G2 were smaller. No difference was detected between G5 and G1. Changes were observed in the nuclei shape in G2 in comparison to G1. Considering G2 and G3, a decrease in the size of nuclei was observed in G3. On the other hand, G2 showed changes in shape in the comparative analysis with G4. The size and shape of G1 nuclei were larger than G3 as well as changes in shape were observed when compared to G4. G4 showed smaller nuclei than G3. Therefore, F, associated or not with the practice of PE, does not alter the size and shape of the hepatocytes nuclei; HD combined with sedentarism influences changes in the morphometric parameters of hepatocytes; and the association of simvastatin and PE seems to protect the hepatocytes nuclei with regard to HD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of the present study was to evaluate the effect of pursed-lip breathing (PLB) on cardiac autonomic modulation in individuals with chronic obstructive pulmonary disease (COPD) while at rest. Methods: Thirty-two individuals were allocated to one of two groups: COPD (n = 17; 67.29 +/- 6.87 years of age) and control (n = 15; 63.2 +/- 7.96 years of age). The groups were submitted to a two-stage experimental protocol. The first stage consisted of the characterization of the sample and spirometry. The second stage comprised the analysis of cardiac autonomic modulation through the recording of R-R intervals. This analysis was performed using both nonlinear and linear heart rate variability (HRV). In the statistical analysis, the level of significance was set to 5% (p = 0.05). Results: PLB promoted significant increases in the SD1, SD2, RMSSD and LF (ms(2)) indices as well as an increase in alpha(1) and a reduction in alpha(2) in the COPD group. A greater dispersion of points on the Poincare plots was also observed. The magnitude of the changes produced by PLB differed between groups. Conclusion: PLB led to a loss of fractal correlation properties of heart rate in the direction of linearity in patients with COPD as well as an increase in vagal activity and impact on the spectral analysis. The difference in the magnitude of the changes produced by PLB between groups may be related to the presence of the disease and alterations in the respiration rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the microtensile bond strength to dentin (ATBS) of two total-etching adhesives applied with delays of 1-30 s for curing. Fifty extracted molar teeth were used. Occlusal enamel was sectioned to expose flat dentin surface, which was further polished with 600-grit paper for smear layer standardization. The specimens were divided into two groups, G1: Single Bond total-etching adhesive (SB), and G2: Prime & Bond NT total-etching adhesive (PB). Each group was further divided into 5 subgroups according to the delayed light-cure initiation after the adhesive systems application (n=5): Subgroup 1s - 1 s; Subgroup 5s -5 s; Subgroup 10s - 10 s; Subgroup 20s - 20 s; Subgroup 30s - 30 s. Composite resin cones 5 mm height and 10 mm in diameter were fabricated. Specimens were stored in distilled water at 37 degrees C for 24 h and sectioned to obtain 1 x 1 mm(2) transversal specimens. Specimens were thermocycled and mu TBS was measured. Data were submitted to two-way ANOVA (AdhesiveXDelay time) and Tukey's test. The level of significance was set at 5%. The results in mean MPa(+/- SD) for interaction between adhesive and delay time were: PB/1s - 23.82 +/- 2.54a; SB/5s - 19.52 +/- 2.67b; PB/5s - 18.56 +/- 3.06bc; SB/1s - 15.49 +/- 2.69cd; SB/20s - 16.33 +/- 2.55d; SB/10s - 13.88 +/- 1.67d; PB/10s - 11.04 +/- 1.28e; PB/30s - 10.89 +/- 1.31e; PB/20s - 10.24 +/- 2.33e; SB/30s - 9.19 +/- 1.91e. It was concluded that light-cure initiation timing of total-etching adhesives interferes negatively with mu TBS to dentin. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)