991 resultados para LUMINESCENCE QUANTUM YIELD
Resumo:
Es mostra que, gracies a una extensió en la definició dels Índexs Moleculars Topològics, s'arriba a la formulació d'índexs relacionats amb la teoria de la Semblança Molecular Quàntica. Es posa de manifest la connexió entre les dues metodologies: es revela que un marc de treball teòric sòlidament fonamentat sobre la teoria de la Mecànica Quàntica es pot connectar amb una de les tècniques més antigues relacionades amb els estudis de QSPR. Es mostren els resultats per a dos casos d'exemple d'aplicació d'ambdues metodologies
Resumo:
Semiconductor nanoparticles, such as quantum dots (QDs), were used to carry out experiments in vivo and ex vivo with Trypanosoma cruzi. However, questions have been raised regarding the nanotoxicity of QDs in living cells, microorganisms, tissues and whole animals. The objective of this paper was to conduct a QD nanotoxicity study on living T. cruzi protozoa using analytical methods. This was accomplished using in vitro experiments to test the interference of the QDs on parasite development, morphology and viability. Our results show that after 72 h, a 200 μM cadmium telluride (CdTe) QD solution induced important morphological alterations in T. cruzi, such as DNA damage, plasma membrane blebbing and mitochondrial swelling. Flow cytometry assays showed no damage to the plasma membrane when incubated with 200 μM CdTe QDs for up to 72 h (propidium iodide cells), giving no evidence of classical necrosis. Parasites incubated with 2 μM CdTe QDs still proliferated after seven days. In summary, a low concentration of CdTe QDs (2 μM) is optimal for bioimaging, whereas a high concentration (200 μM CdTe) could be toxic to cells. Taken together, our data indicate that 2 μM QD can be used for the successful long-term study of the parasite-vector interaction in real time.
Resumo:
The European Prospective Investigation into Cancer and nutrition (EPIC) is a long-term, multi-centric prospective study in Europe investigating the relationships between cancer and nutrition. This study has served as a basis for a number of Genome-Wide Association Studies (GWAS) and other types of genetic analyses. Over a period of 5 years, 52,256 EPIC DNA samples have been extracted using an automated DNA extraction platform. Here we have evaluated the pre-analytical factors affecting DNA yield, including anthropometric, epidemiological and technical factors such as center of subject recruitment, age, gender, body-mass index, disease case or control status, tobacco consumption, number of aliquots of buffy coat used for DNA extraction, extraction machine or procedure, DNA quantification method, degree of haemolysis and variations in the timing of sample processing. We show that the largest significant variations in DNA yield were observed with degree of haemolysis and with center of subject recruitment. Age, gender, body-mass index, cancer case or control status and tobacco consumption also significantly impacted DNA yield. Feedback from laboratories which have analyzed DNA with different SNP genotyping technologies demonstrate that the vast majority of samples (approximately 88%) performed adequately in different types of assays. To our knowledge this study is the largest to date to evaluate the sources of pre-analytical variations in DNA extracted from peripheral leucocytes. The results provide a strong evidence-based rationale for standardized recommendations on blood collection and processing protocols for large-scale genetic studies.
Resumo:
The lanthanide binuclear helicate [Eu(2)(L(C2(CO(2)H)))(3)] is coupled to avidin to yield a luminescent bioconjugate EuB1 (Q = 9.3%, tau((5)D(0)) = 2.17 ms). MALDI/TOF mass spectrometry confirms the covalent binding of the Eu chelate and UV-visible spectroscopy allows one to determine a luminophore/protein ratio equal to 3.2. Bio-affinity assays involving the recognition of a mucin-like protein expressed on human breast cancer MCF-7 cells by a biotinylated monoclonal antibody 5D10 to which EuB1 is attached via avidin-biotin coupling demonstrate that (i) avidin activity is little affected by the coupling reaction and (ii) detection limits obtained by time-resolved (TR) luminescence with EuB1 and a commercial Eu-avidin conjugate are one order of magnitude lower than those of an organic conjugate (FITC-streptavidin). In the second part of the paper, conditions for growing MCF-7 cells in 100-200 microm wide microchannels engraved in PDMS are established; we demonstrate that EuB1 can be applied as effectively on this lab-on-a-chip device for the detection of tumour-associated antigens as on MCF-7 cells grown in normal culture vials. In order to exploit the versatility of the ligand used for self-assembling [Ln(2)(L(C2(CO(2)H)))(3)] helicates, which sensitizes the luminescence of both Eu(III) and Tb(III) ions, a dual on-chip assay is proposed in which estrogen receptors (ERs) and human epidermal growth factor receptors (Her2/neu) can be simultaneously detected on human breast cancer tissue sections. The Ln helicates are coupled to two secondary antibodies: ERs are visualized by red-emitting EuB4 using goat anti-mouse IgG and Her2/neu receptors by green-emitting TbB5 using goat anti-rabbit IgG. The fact that the assay is more than 6 times faster and requires 5 times less reactants than conventional immunohistochemical assays provides essential advantages over conventional immunohistochemistry for future clinical biomarker detection.
Resumo:
Es descriu l'aproximació de Capes Atòmiques dins de la teoria de la Semblança Molecular Quàntica. Partint només de dades teòriques, s'ha trobat una relació entre estructura molecular i activitat biològica per a diversos conjunts de molècules. Es descriuen els aspectes teòrics de la Semblança Molecular Quàntica i alguns exemples d'aplicació
Resumo:
In order to evaluate the diagnostic yield of a PCR assay for patients with focal complications of brucellosis, we studied by PCR and by conventional microbiological techniques 34 nonblood samples from 32 patients with different focal forms of brucellosis. The samples from patients with brucellosis were paired to an equal number of control samples from the same locations of patients whose illnesses had different etiologies. Thirty-three of the 34 nonblood samples (97%) from the brucellosis patients were positive by PCR, whereas Brucella spp. were isolated from only 29.4% of the conventional cultures. For 11.4% of the patients, the confirmatory serological tests were either negative or showed titers below the diagnostic range. Two patients (6.2%) from the control group, both with tuberculous vertebral osteomyelitis, had a positive PCR result. The brucella PCR of blood from these two patients was also positive, and the two strains of Mycobacterium tuberculosis isolated were analyzed by the brucella PCR, with no evidence of amplification. These results show that the PCR assay is far more sensitive than conventional cultures, and this, coupled with its speed and reduction in risk to laboratory workers, makes this technique a very useful tool for the diagnosis of focal complications of brucellosis.
Resumo:
A new practical method to generate a subspace of active coordinates for quantum dynamics calculations is presented. These reduced coordinates are obtained as the normal modes of an analytical quadratic representation of the energy difference between excited and ground states within the complete active space self-consistent field method. At the Franck-Condon point, the largest negative eigenvalues of this Hessian correspond to the photoactive modes: those that reduce the energy difference and lead to the conical intersection; eigenvalues close to 0 correspond to bath modes, while modes with large positive eigenvalues are photoinactive vibrations, which increase the energy difference. The efficacy of quantum dynamics run in the subspace of the photoactive modes is illustrated with the photochemistry of benzene, where theoretical simulations are designed to assist optimal control experiments
Resumo:
Quantum molecular similarity (QMS) techniques are used to assess the response of the electron density of various small molecules to application of a static, uniform electric field. Likewise, QMS is used to analyze the changes in electron density generated by the process of floating a basis set. The results obtained show an interrelation between the floating process, the optimum geometry, and the presence of an external field. Cases involving the Le Chatelier principle are discussed, and an insight on the changes of bond critical point properties, self-similarity values and density differences is performed
Resumo:
The electron hole transfer (HT) properties of DNA are substantially affected by thermal fluctuations of the π stack structure. Depending on the mutual position of neighboring nucleobases, electronic coupling V may change by several orders of magnitude. In the present paper, we report the results of systematic QM/molecular dynamic (MD) calculations of the electronic couplings and on-site energies for the hole transfer. Based on 15 ns MD trajectories for several DNA oligomers, we calculate the average coupling squares 〈 V2 〉 and the energies of basepair triplets X G+ Y and X A+ Y, where X, Y=G, A, T, and C. For each of the 32 systems, 15 000 conformations separated by 1 ps are considered. The three-state generalized Mulliken-Hush method is used to derive electronic couplings for HT between neighboring basepairs. The adiabatic energies and dipole moment matrix elements are computed within the INDO/S method. We compare the rms values of V with the couplings estimated for the idealized B -DNA structure and show that in several important cases the couplings calculated for the idealized B -DNA structure are considerably underestimated. The rms values for intrastrand couplings G-G, A-A, G-A, and A-G are found to be similar, ∼0.07 eV, while the interstrand couplings are quite different. The energies of hole states G+ and A+ in the stack depend on the nature of the neighboring pairs. The X G+ Y are by 0.5 eV more stable than X A+ Y. The thermal fluctuations of the DNA structure facilitate the HT process from guanine to adenine. The tabulated couplings and on-site energies can be used as reference parameters in theoretical and computational studies of HT processes in DNA
Resumo:
PDMS-based microfluidic devices combined with lanthanide-based immunocomplexes have been successfully tested for the multiplex detection of biomarkers on cancerous tissues, revealing an enhanced sensitivity compared to classical organic dyes.
Resumo:
The aim of this thesis is to present a solution to the quantum phase problem of the single-mode optical field. The solution is based on the use of phase shift covariant normalized positive operator measures. These measures describe realistic direct coherent state phase measurements such as the phase measurement schemes based on eight-port homodyne detection or heterodyne detection. The structure of covariant operator measures and, more generally, covariant sesquilinear form measures is analyzed in this work. Four different characterizations for phase shift covariant normalized positive operator measures are presented. The canonical covariant operator measure is definded and its properties are studied. Finally, some other suggested phase theories are introduced to investigate their connections to the covariant sesquilinear form measures.
Resumo:
An affine asset pricing model in which traders have rational but heterogeneous expectations aboutfuture asset prices is developed. We use the framework to analyze the term structure of interestrates and to perform a novel three-way decomposition of bond yields into (i) average expectationsabout short rates (ii) common risk premia and (iii) a speculative component due to heterogeneousexpectations about the resale value of a bond. The speculative term is orthogonal to public informationin real time and therefore statistically distinct from common risk premia. Empirically wefind that the speculative component is quantitatively important accounting for up to a percentagepoint of yields, even in the low yield environment of the last decade. Furthermore, allowing for aspeculative component in bond yields results in estimates of historical risk premia that are morevolatile than suggested by standard Affine Gaussian term structure models which our frameworknests.
Resumo:
BACKGROUND: The quality of colon cleansing is a major determinant of quality of colonoscopy. To our knowledge, the impact of bowel preparation on the quality of colonoscopy has not been assessed prospectively in a large multicenter study. Therefore, this study assessed the factors that determine colon-cleansing quality and the impact of cleansing quality on the technical performance and diagnostic yield of colonoscopy. METHODS: Twenty-one centers from 11 countries participated in this prospective observational study. Colon-cleansing quality was assessed on a 5-point scale and was categorized on 3 levels. The clinical indication for colonoscopy, diagnoses, and technical parameters related to colonoscopy were recorded. RESULTS: A total of 5832 patients were included in the study (48.7% men, mean age 57.6 [15.9] years). Cleansing quality was lower in elderly patients and in patients in the hospital. Procedures in poorly prepared patients were longer, more difficult, and more often incomplete. The detection of polyps of any size depended on cleansing quality: odds ratio (OR) 1.73: 95% confidence interval (CI)[1.28, 2.36] for intermediate-quality compared with low-quality preparation; and OR 1.46: 95% CI[1.11, 1.93] for high-quality compared with low-quality preparation. For polyps >10 mm in size, corresponding ORs were 1.0 for low-quality cleansing, OR 1.83: 95% CI[1.11, 3.05] for intermediate-quality cleansing, and OR 1.72: 95% CI[1.11, 2.67] for high-quality cleansing. Cancers were not detected less frequently in the case of poor preparation. CONCLUSIONS: Cleansing quality critically determines quality, difficulty, speed, and completeness of colonoscopy, and is lower in hospitalized patients and patients with higher levels of comorbid conditions. The proportion of patients who undergo polypectomy increases with higher cleansing quality, whereas colon cancer detection does not seem to critically depend on the quality of bowel preparation.