919 resultados para Jorge, Lidia
Resumo:
A little-known facet of Cuban internationalism is the Cuba shares in the education of young people who want to help build a stronger media culture that represents voices from the global South. Cuba was instrumental in the establishment and operation of the International Film and Television School at San Antonio de los Baños. The Cuban government provided the location and buildings for the school, and among the range of international media professionals who teach the students are selected Cuban professors from the Institute of the Arts, based n Havana. The International Film and Television School is supported by funding from Spain and other countries, and by the willingness of international media professionals to teach short courses for little more than an honorarium. Cuba used to provide full scholarships for student from the South to study a two-year course in film or television, but now charges fees for its three-year diploma course.
Resumo:
Household air pollution (HAP), arising mainly from the combustion of solid and other polluting fuels, is responsible for a very substantial public health burden, most recently estimated as causing 3.5 million premature deaths in 2010. These patterns of household fuel use have also important negative impacts on safety, prospects for poverty reduction and the environment, including climate change. Building on previous air quality guidelines, the WHO is developing new guidelines focused on household fuel combustion, covering cooking, heating and lighting, and although global, the key focus is low and middle income countries reflecting the distribution of disease burden. As discussed in this paper, currently in development, the guidelines will include reviews of a wide range of evidence including fuel use in homes, emissions from stoves and lighting, household air pollution and exposure levels experienced by populations, health risks, impacts of interventions on HAP and exposure, and also key factors influencing sustainable and equitable adoption of improved stoves and cleaner fuels. GRADE, the standard method used for guidelines evidence review may not be well suited to the variety and nature of evidence required for this project, and a modified approach is being developed and tested. Work on the guidelines is being carried out in close collaboration with the UN Foundation Global Alliance on Clean cookstoves, allowing alignment with specific tools including recently developed international voluntary standards for stoves, and the development of country action plans. Following publication, WHO plans to work closely with a number of countries to learn from implementation efforts, in order to further strengthen support and guidance. A case study on the situation and policy actions to date in Bhutan provide an illustration of the challenges and opportunities involved, and the timely importance of the new guidelines and associated research, evaluation and policy development agendas.
Resumo:
As a result of growing evidence regarding the effects of environmental characteristics on the health and wellbeing of people in healthcare facilities (HCFs), more emphasis is being placed on, and more attention being paid to, the consequences of design choices in HCFs. Therefore, we have critically reviewed the implications of key indoor physical design parameters, in relation to their potential impact on human health and wellbeing. In addition, we discussed these findings within the context of the relevant guidelines and standards for the design of HCFs. A total of 810 abstracts, which met the inclusion criteria, were identified through a Pubmed search, and these covered journal articles, guidelines, books, reports and monographs in the studied area. Of these, 231 full publications were selected for this review. According to the literature, the most beneficial design elements were: single-bed patient rooms, safe and easily cleaned surface materials, sound-absorbing ceiling tiles, adequate and sufficient ventilation, thermal comfort, natural daylight, control over temperature and lighting, views, exposure and access to nature, and appropriate equipment, tools and furniture. The effects of some design elements, such as lighting (e.g. artificial lighting levels) and layout (e.g. decentralized versus centralized nurses’ stations), on staff and patients vary, and “the best design practice” for each HCF should always be formulated in co-operation with different user groups and a multi-professional design team. The relevant guidelines and standards should also be considered in future design, construction and renovations, in order to produce more favourable physical indoor environments in HCFs.
Resumo:
Understanding the physical characteristics of the indoor environment that affect human health and wellbeing is the key requirement underpinning the beneficial design of a healthcare facility (HCF). We reviewed and summarised physical factors of the indoor environment reported to affect human health and wellbeing in HCFs. Research materials included articles identified in a Pubmed search, guidelines, books, reports and monographs, as well as the bibliographies of review articles in the area studied. Of these, 209 publications were selected for this review. According to the literature, there is evidence that the following physical factors of the indoor environment affect the health and wellbeing of human beings in an HCF: safety, ventilation and HVAC systems, thermal environment, acoustic environment, interior layout and room type, windows (including daylight and views), nature and gardens, lighting, colour, floor covering, furniture and its placement, ergonomics, wayfinding, artworks and music. Some of these, in themselves, directly promote or hinder health and wellbeing, but the physical factors may also have numerous indirect impacts by influencing the behaviour, actions, and interactions of patients, their families and the staff members. The findings of this research enable a good understanding of the different physical factors of the indoor environment on health and wellbeing and provide a practical resource for those responsible for the design and operate the facilities as well as researchers investigating these factors. However, more studies are needed in order to inform the design of optimally beneficial indoor environments in HCFs for all user groups.
Resumo:
Particulate matter is common in our environment and has been linked to human health problems particularly in the ultrafine size range. A range of chemical species have been associated with particulate matter and of special concern are the hazardous chemicals that can accentuate health problems. If the sources of such particles can be identified then strategies can be developed for the reduction of air pollution and consequently, the improvement of the quality of life. In this investigation, particle number size distribution data and the concentrations of chemical species were obtained at two sites in Brisbane, Australia. Source apportionment was used to determine the sources (or factors) responsible for the particle size distribution data. The apportionment was performed by Positive Matrix Factorisation (PMF) and Principal Component Analysis/Absolute Principal Component Scores (PCA/APCS), and the results were compared with information from the gaseous chemical composition analysis. Although PCA/APCS resolved more sources, the results of the PMF analysis appear to be more reliable. Six common sources identified by both methods include: traffic 1, traffic 2, local traffic, biomass burning, and two unassigned factors. Thus motor vehicle related activities had the most impact on the data with the average contribution from nearly all sources to the measured concentrations higher during peak traffic hours and weekdays. Further analyses incorporated the meteorological measurements into the PMF results to determine the direction of the sources relative to the measurement sites, and this indicated that traffic on the nearby road and intersection was responsible for most of the factors. The described methodology which utilised a combination of three types of data related to particulate matter to determine the sources could assist future development of particle emission control and reduction strategies.
Resumo:
Deterioration of air quality in Indian megacities (Delhi, Mumbai or Kolkata) is much more significant than that observed in the megacities of developed countries. Densely packed high-rise buildings restrict the self-cleaning capabilities of Indian megacities. Also, the ever growing number of on-road vehicles, resuspension of the dust, and anthropogenic activities exacerbate the levels of ambient air pollution, which is in turn breathed by urban dwellers. Pollution levels exceeding the standards on a regular basis often result in a notable increase in morbidity and mortality. This article discusses the challenges faced by Indian megacities in their quest for sustainable growth, without compromising the air quality and urban way of life.
Resumo:
Background: Bicycle commuting in an urban environment of high air pollution is known as a potential health risk, especially for susceptible individuals. While risk management strategies aimed to reduce motorised traffic emissions exposure have been suggested, limited studies have assessed the utility of such strategies in real-world circumstances. Objectives: The potential of reducing exposure to ultrafine particles (UFP; < 0.1 µm) during bicycle commuting by lowering interaction with motorised traffic was investigated with real-time air pollution and acute inflammatory measurements in healthy individuals using their typical, and an alternative to their typical, bicycle commute route. Methods: Thirty-five healthy adults (mean ± SD: age = 39 ± 11 yr; 29% female) each completed two return trips of their typical route (HIGH) and a pre-determined altered route of lower interaction with motorised traffic (LOW; determined by the proportion of on-road cycle paths). Particle number concentration (PNC) and diameter (PD) were monitored in real-time in-commute. Acute inflammatory indices of respiratory symptom incidence, lung function and spontaneous sputum (for inflammatory cell analyses) were collected immediately pre-commute, and one and three hours post-commute. Results: LOW resulted in a significant reduction in mean PNC (1.91 x e4 ± 0.93 x e4 ppcc vs. 2.95 x e4 ± 1.50 x e4 ppcc; p ≤ 0.001). Besides incidence of in-commute offensive odour detection (42 vs. 56 %; p = 0.019), incidence of dust and soot observation (33 vs. 47 %; p = 0.038) and nasopharyngeal irritation (31 vs. 41 %; p = 0.007), acute inflammatory indices were not significantly associated to in-commute PNC, nor were these indices reduced with LOW compared to HIGH. Conclusions: Exposure to PNC, and the incidence of offensive odour and nasopharyngeal irritation, can be significantly reduced when utilising a strategy of lowering interaction with motorised traffic whilst bicycle commuting, which may bring important benefits for both healthy and susceptible individuals.
Resumo:
Air pollution has significant impacts on both the environment and human health. Therefore, urban areas have received ever growing attention, because they not only have the highest concentrations of air pollutants, but they also have the highest human population. In modern societies, urban air quality (UAQ) is routinely evaluated and local authorities provide regular reports to the public about current UAQ levels. Both local and international authorities also recommended that some air pollutant concentrations remain below a certain level, with the aim of reducing emissions and improving the air quality, both in urban areas and on a more regional scale. In some countries, protocols aimed at reducing emissions have come in force as a result of international agreements.
Resumo:
Long term exposure to vehicle emissions has been associated with harmful health effects. Children are amongst the most susceptible group and schools represent an environment where they can experience significant exposure to vehicle emissions. However, there are limited studies on children’s exposure to vehicle emissions in schools. The aim of this study was to quantify the concentration of organic aerosol and in particular, vehicle emissions that children are exposed to during school hours. Therefore an Aerodyne compact time-of-flight aerosol mass spectrometer (TOF-AMS) was deployed at five urban schools in Brisbane, Australia. The TOF-AMS enabled the chemical composition of the non- refractory (NR-PM1) to be analysed with a high temporal resolution to assess the concentration of vehicle emissions and other organic aerosols during school hours. At each school the organic fraction comprised the majority of NR-PM1 with secondary organic aerosols as the main constitute. At two of the schools, a significant source of the organic aerosol (OA) was slightly aged vehicle emissions from nearby highways. More aged and oxidised OA was observed at the other three schools, which also recorded strong biomass burning influences. Primary emissions were found to dominate the OA at only one school which had an O:C ratio of 0.17, due to fuel powered gardening equipment used near the TOF-AMS. The diurnal cycle of OA concentration varied between schools and was found to be at a minimum during school hours. The major organic component that school children were exposed to during school hours was secondary OA. Peak exposure of school children to HOA occurred during school drop off and pick up times. Unless a school is located near major roads, children are exposed predominately to regional secondary OA as opposed to local emissions during schools hours in urban environments.
Resumo:
In order to provide realistic data for air pollution inventories and source apportionment at airports, the morphology and composition of ultrafine particles (UFP) in aircraft engine exhaust were measured and characterized. For this purpose, two independent measurement techniques were employed to collect emissions during normal takeoff and landing operations at Brisbane Airport, Australia. PM1 emissions in the airfield were collected on filters and analyzed using the particle-induced X-ray emission (PIXE) technique. Morphological and compositional analyses of individual ultrafine particles in aircraft plumes were performed on silicon nitride membrane grids using transmission electron microscopy (TEM) combined with energy-dispersive X-ray microanalysis (EDX). TEM results showed that the deposited particles were in the range of 5 to 100 nm in diameter, had semisolid spherical shapes and were dominant in the nucleation mode (18 – 20 nm). The EDX analysis showed the main elements in the nucleation particles were C, O, S and Cl. The PIXE analysis of the airfield samples was generally in agreement with the EDX in detecting S, Cl, K, Fe and Si in the particles. The results of this study provide important scientific information on the toxicity of aircraft exhaust and their impact on local air quality.
Resumo:
It has not yet been established whether the spatial variation of particle number concentration (PNC) within a microscale environment can have an effect on exposure estimation results. In general, the degree of spatial variation within microscale environments remains unclear, since previous studies have only focused on spatial variation within macroscale environments. The aims of this study were to determine the spatial variation of PNC within microscale school environments, in order to assess the importance of the number of monitoring sites on exposure estimation. Furthermore, this paper aims to identify which parameters have the largest influence on spatial variation, as well as the relationship between those parameters and spatial variation. Air quality measurements were conducted for two consecutive weeks at each of the 25 schools across Brisbane, Australia. PNC was measured at three sites within the grounds of each school, along with the measurement of meteorological and several other air quality parameters. Traffic density was recorded for the busiest road adjacent to the school. Spatial variation at each school was quantified using coefficient of variation (CV). The portion of CV associated with instrument uncertainty was found to be 0.3 and therefore, CV was corrected so that only non-instrument uncertainty was analysed in the data. The median corrected CV (CVc) ranged from 0 to 0.35 across the schools, with 12 schools found to exhibit spatial variation. The study determined the number of required monitoring sites at schools with spatial variability and tested the deviation in exposure estimation arising from using only a single site. Nine schools required two measurement sites and three schools required three sites. Overall, the deviation in exposure estimation from using only one monitoring site was as much as one order of magnitude. The study also tested the association of spatial variation with wind speed/direction and traffic density, using partial correlation coefficients to identify sources of variation and non-parametric function estimation to quantify the level of variability. Traffic density and road to school wind direction were found to have a positive effect on CVc, and therefore, also on spatial variation. Wind speed was found to have a decreasing effect on spatial variation when it exceeded a threshold of 1.5 (m/s), while it had no effect below this threshold. Traffic density had a positive effect on spatial variation and its effect increased until it reached a density of 70 vehicles per five minutes, at which point its effect plateaued and did not increase further as a result of increasing traffic density.