994 resultados para Integrated seminar
Resumo:
An on-farm trial was conducted over 150 days to determine appropriate stocking ratio, growth and production of climbing perch (Anabas testudineus) in cages and carps in open water of ponds in eighteen farmers' ponds from Haluaghat Upazila at Mymensingh district of Bangladesh. One or two 1 m super(3) cage was suspended in each of 12 earthen ponds and other 6 ponds served as control without cages. Climbing perch of 2-3 g in size were stocked in cages while fingerlings of silver carp (Hypophthalmicthys molitrix), catla (Catla catla), rohu (Labeo rohita), mirgal (Cirhinus cirrhosus), rajputi (Puntius sarana) and common carp (Cyprinus carpio) were stocked at 1 fish/m super(2) with a species ratio of 5:4:4:4:2:1 in open water of all ponds to give cage to open-pond fish ratios of 1:1 (T sub(1:1)) and 2:1 (T sub(2:1)) and 0:1 (T sub(0:1)) as three treatments with six replicates each. Survival of climbing perch was higher in T sub(1:1) (61.67%) than that of T sub(2:1) (29.5%) and was significantly different (p>0.05) between the treatments. Stocking of small size climbing perch fry increased the mortality rate in cages. The net yields of Thai koi were 0.13±0.01 (t/ha) and 0.10±0.01 (t/ha) in treatments T sub(1:1) and T sub(2:1), respectively and both were significantly different (p>0.05). Survival of-open-pond carps was high, ranging from 50 to 91.67% with significantly lower in T sub(0:1) than that of T sub(1:1) and T sub(2:1) treatment. Net and gross yield of each carp species were significantly higher in the T sub(1:1) and T sub(2:1) treatment than that in T sub(0:1) treatment. Net revenues were positive but low in all treatments. Therefore, bigger size climbing perch with lower stocking ratio (T sub(1:1)) is suitable for integrated cage-pond culture of climbing perch and carps. However, more on-farm trials in different ecosystem with scientific interventions are necessary to develop the technology for further dissemination among the rural farmers.
Resumo:
This paper examines policy processes, policy trends and policy implementation with regards to capture fisheries, the marine environment and Integrated Coastal Management (ICM) in BOBLME countries. Individual country information was analyzed to generate a regional synthesis.
Resumo:
Student projects included: conservation and protection of critical coral habitats in Phuket; assessing the carrying capacity on conservation and protection strategies; proactive stakeholder strategy to tackle an environmental threat; improving the environmental management through participation and sustainable freshwater management. All of these projects were conducted on Racha Yai Island in Phuket.
Resumo:
Current research into the process of engineering design is extending the use of computers towards the acquisition, representation and application of design process knowledge in addition to the existing storage and manipulation of product-based models of design objects. This is a difficult task because the design of mechanical systems is a complex, often unpredictable process involving ill-structured problem solving skills and large amounts of knowledge, some which may be of an incomplete and subjective nature. Design problems require the integration of a variety of modes of working such as numerical, graphical, algorithmic or heuristic and demand products through synthesis, analysis and evaluation activities.
This report presents the results of a feasibility study into the blackboard approach and discusses the development of an initial prototype system that will enable an alphanumeric design dialogue between a designer and an expert to be analysed in a formal way, thus providing real-life protocol data on which to base the blackboard message structures.
Resumo:
Participants consisted of 25 middle and junior level personnel from BOBLME countries. Modules included: Integrated Coastal Management (ICM) concept and principles; ICM development and implementation; indicators of good practice; and action planning.
Resumo:
Growing fish with rice while maximizing land use can bring advantages to both crops as production is intensified. Details are given of the basic structure of rice field aquaculture, listing the major advantages and disadvantages of this system. Particular reference is made to the integrated farms at Culasi, Antique (Western Philippines) and at Barangay Igcocolo, Guimbal, Iloilo where agricultural crops other than rice are integrated with fish farming (tilapia -- Oreochromis mossambicus) and livestock rearing. An account is also given of the system at the AQD site at New Busuang, Kalibo, Aklan which evaluates the economic feasibility and profitability of farming mudcrab in tidal flats with existing mangroves.
Resumo:
BIPV (building integrated photovoltaics) has progressed in the past years and become an element to be considered in city planning. BIPV has significant influence on microclimate in urban environments and the performance of BIPV is also affected by urban climate. The thermal model and electrical performance model of ventilated BIPV are combined to predict PV temperature and PV power output in Tianjin, China. Then, by using dynamic building energy model, the building cooling load for installing BIPV is calculated. A multi-layer model AUSSSM of urban canopy layer is used to assess the effect of BIPV on the Urban Heat Island (UHI). The simulation results show that in comparison with the conventional roof, the total building cooling load with ventilation PV roof may be decreased by 10%. The UHI effect after using BIPV relies on the surface absorptivity of original building. In this case, the daily total PV electricity output in urban areas may be reduced by 13% compared with the suburban areas due to UHI and solar radiation attenuation because of urban air pollution. The calculation results reveal that it is necessary to pay attention to and further analyze interactions between BIPV and microdimate in urban environments to decrease urban pollution, improve BIPV performance and reduce cooling load. Copyright © 2006 by ASME.
Resumo:
Building integrated photovoltaics (BIPV) has potential of becoming the mainstream of renewable energy in the urban environment. BIPV has significant influence on the thermal performance of building envelope and changes radiation energy balance by adding or replacing conventional building elements in urban areas. PTEBU model was developed to evaluate the effect of photovoltaic (PV) system on the microclimate of urban canopy layer. PTEBU model consists of four sub-models: PV thermal model, PV electrical performance model, building energy consumption model, and urban canyon energy budget model. PTEBU model is forced with temperature, wind speed, and solar radiation above the roof level and incorporates detailed data of PV system and urban canyon in Tianjin, China. The simulation results show that PV roof and PV façade with ventilated air gap significantly change the building surface temperature and sensible heat flux density, but the air temperature of urban canyon with PV module varies little compared with the urban canyon of no PV. The PV module also changes the magnitude and pattern of diurnal variation of the storage heat flux and the net radiation for the urban canyon with PV increase slightly. The increase in the PV conversion efficiency not only improves the PV power output, but also reduces the urban canyon air temperature. © 2006.
Resumo:
It is generally recognized that BIPV (building integrated photovoltaics) has the potential to become a major source of renewable energy in the urban environment. The actual output of a PV module in the field is a function of orientation, total irradiance, spectral irradiance, wind speed, air temperature, soiling and various system-related losses. In urban areas, the attenuation of solar radiation due to air pollution is obvious, and the solar spectral content subsequently changes. The urban air temperature is higher than that in the surrounding countryside, and the wind speed in urban areas is usually less than that in rural areas. Three different models of PV power are used to investigate the effect of urban climate on PV performance. The results show that the dimming of solar radiation in the urban environment is the main reason for the decrease of PV module output using the climatic data of urban and rural sites in Mexico City for year 2003. The urban PV conversion efficiency is higher than that of the rural PV system because the PV module temperature in the urban areas is slightly lower than that in the rural areas in the case. The DC power output of PV seems to be underestimated if the spectral response of PV in the urban environment is not taken into account based on the urban hourly meteorological data of Sao Paulo for year 2004. © 2006 Elsevier Ltd. All rights reserved.
Resumo:
Building integrated photovoltaics (BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influence on the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. Four different roofs are used to assess the impacts of BIPV on the building's heating-and-cooling loads; namely ventilated air-gap BIPV, non-ventilated (closed) air-gap BIPV, closeroof mounted BIPV, and the conventional roof with no PV and no air gap. One-dimensional transient models of four cases are derived to evaluate the PV performances and building cooling-and-heating loads across the different roofs in order to select the appropriate PV building integration method in Tianjin, China. The simulation results show that the PV roof with ventilated air-gap is suitable for the application in summer because this integration leads to the low cooling load and high PV conversion efficiency. The PV roof with ventilation air-gap has a high time lag and small decrement factor in comparison with other three roofs and has the same heat gain as the cool roof of absorptance 0.4. In winter, BIPV of non-ventilated air gap is more appropriate due to the combination of the low heating-load through the PV roof and high PV electrical output. © 2005 Elsevier Ltd. All rights reserved.