931 resultados para Injection molding of plastics
Resumo:
We determined the effect of intracerebroventricular (icv) administration of losartan, an angiotensin II (ANG II) subtype 1 receptor (AT1) antagonist, on icv carbachol-induced natriuresis, kaliuresis and antidiuresis in water-loaded male Holtzman rats (250-300 g) with a cannula implanted into the lateral ventricle (LV). The rats were water loaded with 5% of their body weight by gavage twice, with the second gavage one hour after the first. Carbachol (2 nmol in 1 mu l) was injected icv immediately after the second load. When losartan (DUP-753, 50 nmol in 1 mu l) was administered icv, it was given 3 min before carbachol. Previous icv treatment with losartan significantly reduced the icv carbachol-induced natriuresis (324 +/- 17 mu Eq/120 min), kaliuresis (103 +/- 15 mu Eq/120 min) and antidiuresis (13.5 +/- 2.1 ml/120 min) compared to the effects of previous icv injection of saline (Nai excretion = 498 +/- 22 mu Eq/120 min; K+ excretion = 167 +/- 20 mu Eq/120 min; urine volume = 5.2 +/- 1.2 ml/120 min). These results, reported as means +/- SEM for 12 rats in each group, are consistent with the hypothesis that AT1 subtype receptors participate in the regulation of body electrolyte balance.
Resumo:
A flow injection system with online sample preparation is proposed for the determination of phosphite in liquid fertilizers by spectrophotometry. After loop-based injection, phosphite is oxidized by an acidic permanganate solution (1.0 10(-2) mol L-1 KMnO4 + 1.0 mol L-1 H2SO4) in a heated reactor (50 degreesC). The phosphate generated is then determined by the molybdenum blue method. Influence of flow rates, temperature, and concentration and order of addition of reagents, sample volume, and reactor configuration for the blue complex formation on recorded signals were investigated. The pow system was applied to phosphite determination in commercial samples of liquid fertilizers. The proposed system handles about 80 samples per hour [0.05-0.40% (w/v) H3PO3; R = 0,9998], consuming about 80 muL sample, 1 mg KMnO4, 25 mg (NH)(6)Mo7O24, and Ia mg ascorbic acid per determination. Results are precise [relative standard deviation less than or equal to 3.5% for 0.1% (w/v) H3PO3, n = 12] and in agreement with those obtained by gravimetry at 95% confidence level. (C) 2000 John Wiley & Sons, Inc.
Resumo:
We studied the effect of ramipril injected into the third ventricle (3rdV) on the control of water intake induced by injection of noradrenaline into the 3rdV of adult male Holtzman rats (250-300 g) implanted with a chronic stainless steel cannula into the 3rdV. The injection volume was always 1 mu l and was injected over a period of 30-60 sec. Control animals were injected with 0.15 M NaCl. After the injection of isotonic saline (control, 0.15 M NaCl) into the 3rdV, water ingestion was 0.3 +/- 0.1 ml/h. Ramipril (1 mu g/mu l) injected into the 3rdV prior to isotonic saline produced no changes in water ingestion (0.4 +/- 0.2 ml/h). The injection of noradrenaline (40 nmol/mu l) after isotonic saline induced an increase in water intake (3.0 +/- 1.1 ml/h). The prior injection of ramipril decreased this ingestion to 1.8 +/- 0.3 ml/h. These data show that the inhibition of converting enzyme in the brain reduces the water intake induced by catecholaminergic stimulation. We conclude that the brain is able to transform the prodrug ramipril into the active drug ramiprilat.
Resumo:
A sensor based on graphite electrode modified with palladium-platinum-palladium film is proposed for phosphite determination by flow-injection amperometry. The modified electrode was prepared by a sequential cathodic deposition of Pd, Pt and Pd on a graphite electrode from 0.5% m/v PdCl2 + 28% m/v NH4OH and 2% m/v H2PtCl6 + 10% v/v H2SO4 solutions. After suitable conditioning, the electrode showed catalytic activity for phosphite oxidation when 0. 15 V was applied. The proposed system handles approximately 50 samples per hour (0.0.1 - 0.05 mol L-1 Na-2 HPO3; R-2 = 0.9997), consuming ca. 70 mu L of sample per determination. The limit of detection and amperometric sensibility were 5 X 10(-4) mol L-1 and 1.5 mA L mol(-1), respectively. The proposed method was applied to analysis of fertilizer samples without pre-treatment. Results are in agreement with those obtained by spectrophotometry and titrimetry at 95% confidence level and good recoveries (96-109%) of spiked samples were found. Relative standard deviation (n=12) of a 0.01 mol L-1 Na2HPO3 sample was 2%. The useful lifetime of modified electrode was around 220 determinations. For routine purposes it means that this electrode can be continuously used for 5 hours.
Resumo:
Superoxide radical (O2-) is a free radical that may be involved in various toxic processes. Cu-Zn superoxide dismutase catalyses the dismutation of the superoxide free radical and protects cells from oxidative damage, and it has been used clinically. The concentration of Ni2+ and Cu-Zn superoxide dismutase activity were measured in lungs of rats at time intervals of 5, 12, 19, 26, 33, and 40 days following an intratracheal injection of 127 nmol of NiCl2. Nickel chloride increased nickel content and resulted in a significant increase of Cu-Zn superoxide dismutase activity in lungs. This elevation of Cu-Zn superoxide dismutase activity was highest on the 12th day (approximately threefold) and is at levels comparable to controls rats on day 40 onwards. Since Cu-Zn superoxide dismutase activity was increased in lung throughout our experimental period without corresponding increases of Cu2+ and Zn2+, we speculate that the elevation of Cu-Zn superoxide dismutase activity might be due to an increased half-life of the enzyme, induced by nickel.
Resumo:
A comparative study is reported between C-18 bonded silica gel and powdered polyethylene (PE) as sorbent for Cd, Cu, and Pb determination using ammonium diethyldithiophosphate (ADTP) as the complexing agent in a flow injection system. The complexes were formed in 0.14 mol L-1 HNO3 and processed in a simple flow system comprising a peristaltic pump, a manual injector-commutator, and a sorbent-packed minicolumn. Ethanol was selected as the eluent and analytes in the eluate were determined by flame atomic absorption spectrometry. The optimum concentration of the complexing agent was 0.1% (m/v) ADTP for Cu and Pb determination using either C-18 or PE, and 0.25% (m/v) ADTP for Cd determination using PE. The sample loading flow rates were 5.0, 3.6, and 3.0 mL min(-1) for Cu, Pb, and Cd, respectively. The best elution flow rate was 6.5 mL min(-1). For a 60-sec preconcentration time, the sampling rate was 40 h(-1) and the enrichment factors of 33, 36, and 11 times (C-18) or 18, 22, and 23 times (PE) were obtained for Cu, Pb, and Cd, respectively. The limits of detection (LOD) were 1.6 mug L-1 Cu, 11 mug L-1 Pb, and 2.0 mug L-1 Cd using C-18 or 2.9 mug L-1 Cu, 19 mug L-1 Pb, and 1.0 mug L-1 Cd using PE, respectively. The relative standard deviations (n = 12) were typically <2%, <2%, and <6% for Cd, Cu, and Pb, respectively. The recoveries of Cd, Cu, and Pb added to wine samples varied from 96-99%, 97-102%, and 90-99%, respectively, using C-18 or PE. Accuracy was checked for Cd, Cu, and Pb determination in six wine samples digested by block digestor and open-vessel microwave-assisted digestion systems. The results revealed that C-18 was more efficient for Cu and Pb determination, while PE was the best sorbent for Cd.
Resumo:
A new method was developed for the simultaneous determination of As, Bi, Sb, and Se by flow injection hydride generation graphite furnace atomic absorption spectrometry. An alternative two-step sample treatment procedure was used. The sample was heated (80degreesC) for 10 min in 6 M HCl to reduce Se(VI) to Se(IV), followed by the addition of 1% (m/v) thiourea solution to reduce arsenic and antimony from the pentavalent to the trivalent states.With this procedure, all analytes were converted to their most favorable and sensitive oxidation states to generate the corresponding hydrides. The pre-treated sample solution was then processed in the flow system for in situ trapping and atomization in a graphite tube coated with iridium. The impermanent modifier remained stable up to 300 firings and new coating out significant were possible wit changes in the analytical performance.The accuracy was checked for As, Bi, Sb, and Se determination in water standard reference materials NIST 1640 and 1643d and the results were in agreement with the certified values at a 95% confidence level. Good recoveries (94-104%.) of spiked mineral waters and synthetic As(V), Sb(Ill), mixtures of As(Ill), Sb(V), Se(VI), and Se(IV) were also found. Calculated characteristic masses were 32 mug As, 79 mug Bi, 35 mug Sb, and 130 pg Se, and the corresponding limits of detection were 0.06, 0.16, 0.19, and 0.59 mug L-1, respectively. The repeatability for a typical solution containing 5 mug L-1 As, Bi, Sb, and Se was in the 1-3% range.
Resumo:
An automated system with a C-18 bonded silica gel packed minicolumn is proposed for spectrophotometric detection of arsenic using flow-injection hydride generation following sorbent extraction preconcentration. Complexes formed between arsenic(III) and ammonium diethyl dithiophosphate (ADDP) are retained on a C-18 sorbent. The eluted As-DDP complexes are merged with a 1.5% (w/v) NaBH4 and the resulting solution is thereafter injected into the hydride generator/gas-liquid separator. The arsine generated is carried out by a stream of N-2 and trapped in an alkaline iodine solution in which the analyte is determined by the arsenomolybdenum blue method. With preconcentration time of 120 s, calibration in the 5.00-50.0 mu g As l(-1) range and sampling rate of about 20 samples h(-1) are achieved, corresponding to 36 mg ADDP plus 36 mg ammonium heptamolybdate plus 7 mg hydrazine sulfate plus 0.7 mg stannous chloride and about 7 mi sample consumed per determination. The detection limit is 0.06 mu g l(-1) and the relative standard deviation (n = 12) for a typical 17.0 mu g As l(-1) sample is ca. 6%. The accuracy was checked for arsenic determination in plant materials from the NIST (1572 citrus leaves; 1573 tomato leaves) and the results were in agreement with the certified values at 95% confidence level. Good recoveries (94-104%) of spiked tap waters, sugars and synthetic mixtures of trivalent and pentavalent arsenic were also found. (C) 1999 Elsevier B.V. B.V. All rights reserved.
Resumo:
In order to cooperate in minimizing the problems of the current and growing volume of waste, this work aims at the production of panels made from industrial waste -thermoplastic (Polypropylene - PP; Polyethylene - PE and Acrylonitrile Butadiene Styrene - ABS) reinforced with agro-industrial waste - pupunha palm waste (shells and sheaths). The properties of the panels were evaluated: density, thickness swelling, water absorption and moisture content. It was used the ASTM D1037; EN 317; and ANSI A208.1 standards regarding particle boards. The best results in physical tests were treatments 1 (100% waste plastic), 6 (60% plastic waste and 40% waste of pupunha) and 7 (70% waste plastic and 30% waste of pupunha). The best results in the mechanical tests were treatments 3 (30% de residuos plasticos e 70% de residuos da pupunha), 4 (40% de residuos plasticos c 60% de residuos da pupunha) and 5 (50% de residuos plasticos e 50% de residuos da pupunha). For mechanical tests it was concluded that the results of modulus of rupture and of modulus of elasticity the best treatments were those with more fibers. In the tensile tests perpendicular to the surface, it is clear that using more waste plastics leads to the best results. It was concluded that the waste can be used as raw material for the production of alternative materials mainly in civil construction and furniture industries, and it can be employed in urban or rural environment, given the concept of eco-efficient products.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)