924 resultados para Impedance matching
Resumo:
This dissertation mimics the Turkish college admission procedure. It started with the purpose to reduce the inefficiencies in Turkish market. For this purpose, we propose a mechanism under a new market structure; as we prefer to call, semi-centralization. In chapter 1, we give a brief summary of Matching Theory. We present the first examples in Matching history with the most general papers and mechanisms. In chapter 2, we propose our mechanism. In real life application, that is in Turkish university placements, the mechanism reduces the inefficiencies of the current system. The success of the mechanism depends on the preference profile. It is easy to show that under complete information the mechanism implements the full set of stable matchings for a given profile. In chapter 3, we refine our basic mechanism. The modification on the mechanism has a crucial effect on the results. The new mechanism is, as we call, a middle mechanism. In one of the subdomain, this mechanism coincides with the original basic mechanism. But, in the other partition, it gives the same results with Gale and Shapley's algorithm. In chapter 4, we apply our basic mechanism to well known Roommate Problem. Since the roommate problem is in one-sided game patern, firstly we propose an auxiliary function to convert the game semi centralized two-sided game, because our basic mechanism is designed for this framework. We show that this process is succesful in finding a stable matching in the existence of stability. We also show that our mechanism easily and simply tells us if a profile lacks of stability by using purified orderings. Finally, we show a method to find all the stable matching in the existence of multi stability. The method is simply to run the mechanism for all of the top agents in the social preference.
Resumo:
Negli ultimi anni si è assistito al considerevole aumento della disponibilità di dati GPS e della loro precisione, dovuto alla diffusione e all’evoluzione tecnologica di smartphone e di applicazioni di localizzazione. Il processo di map-matching consiste nell’integrare tali dati - solitamente una lista ordinata di punti, identificati tramite coordinate geografiche ricavate mediante un sistema di localizzazione, come il GPS - con le reti disponibili; nell’ambito dell’ingegneria dei trasporti, l’obiettivo è di identificare il percorso realmente scelto dall’utente per lo spostamento. Il presente lavoro si propone l’obiettivo di studiare alcune metodologie di map-matching per l’identificazione degli itinerari degli utenti, in particolare della mobilità ciclabile. Nel primo capitolo è esposto il funzionamento dei sistemi di posizionamento e in particolare del sistema GPS: ne sono discusse le caratteristiche, la suddivisione nei vari segmenti, gli errori di misurazione e la cartografia di riferimento. Nel secondo capitolo sono presentati i vari aspetti del procedimento di map-matching, le sue principali applicazioni e alcune possibili classificazioni degli algoritmi di map-matching sviluppati in letteratura. Nel terzo capitolo è esposto lo studio eseguito su diversi algoritmi di map-matching, che sono stati testati su un database di spostamenti di ciclisti nell’area urbana di Bologna, registrati tramite i loro smartphone sotto forma di punti GPS, e sulla relativa rete. Si analizzano altresì i risultati ottenuti in un secondo ambiente di testing, predisposto nell’area urbana di Catania, dove sono state registrate in modo analogo alcune tracce di prova, e utilizzata la relativa rete. La comparazione degli algoritmi è eseguita graficamente e attraverso degli indicatori. Vengono inoltre proposti e valutati due algoritmi che forniscono un aggiornamento di quelli analizzati, al fine di migliorarne le prestazioni in termini di accuratezza dei risultati e di costo computazionale.
Resumo:
This paper presents a kernel density correlation based nonrigid point set matching method and shows its application in statistical model based 2D/3D reconstruction of a scaled, patient-specific model from an un-calibrated x-ray radiograph. In this method, both the reference point set and the floating point set are first represented using kernel density estimates. A correlation measure between these two kernel density estimates is then optimized to find a displacement field such that the floating point set is moved to the reference point set. Regularizations based on the overall deformation energy and the motion smoothness energy are used to constraint the displacement field for a robust point set matching. Incorporating this non-rigid point set matching method into a statistical model based 2D/3D reconstruction framework, we can reconstruct a scaled, patient-specific model from noisy edge points that are extracted directly from the x-ray radiograph by an edge detector. Our experiment conducted on datasets of two patients and six cadavers demonstrates a mean reconstruction error of 1.9 mm
Resumo:
The function of the coronary collateral circulation in heart transplant patients has not been investigated in a controlled fashion. Since it partly belongs to the microcirculation, which is affected by transplant vasculopathy, the hypothesis was tested that the coronary collateral circulation in heart transplant recipients is less developed than in coronary artery disease (CAD) patients.
Resumo:
Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.
Resumo:
This study sought to compare all-cause mortality in patients at intermediate surgical risk undergoing transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR).
Resumo:
Symptom association is important to distinguish non-erosive reflux disease [NERD; abnormal oesophageal acid exposure time (AET) and/or positive symptom association] from functional heartburn (FH; normal AET and negative symptom association). Asymptomatic patients during reflux monitoring are challenging as symptom association cannot be assessed.