872 resultados para Hip dysplasia
Resumo:
BOOK: Written by the surgeons of the Exeter Hip Team and their colleagues from around the world, this book describes 40 years of innovation and development with cemented hip replacement. Topics covered include the basic science behind successful cemented hip replacement, modern surgical techniques and recent advances. There is also extensive coverage of the revision techniques developed at Exeter and elsewhere, focussing on femoral and acetabular impaction grafting. Each chapter is a self-contained article with an emphasis, where appropriate, on practical techniques and surgical tips, supported by line drawings and intra-operative photographs.
Resumo:
Key points • The clinical aims of MR spectroscopy (MRS) in seizure disorders are to help identify, localize and characterize epileptogenic foci. • Lateralizing MRS abnormalities in temporal lobe epilepsy (TLE) may be used clinically in combination with structural and T2 MRI measurements together with other techniques such as EEG, PET and SPECT. • Characteristic metabolite abnormalities are decreased N-acetylaspartate (NAA) with increased choline (Cho) and myoinositol (mI) (short-echo time). • Contralateral metabolite abnormalities are frequently seen in TLE, but are of uncertain significance. • In extra-temporal epilepsy, metabolite abnormalities may be seen where MR imaging (MRI) is normal; but may not be sufficiently localized to be useful clinically. • MRS may help to characterize epileptogenic lesions visible on MRI (aggressive vs. indolent neoplastic, dysplasia). • Spectral editing techniques are required to evaluate specific epilepsy-relevant metabolites (e.g. -aminobutyric acid (GABA)), which may be useful in drug development and evaluation. • MRS with phosphorus (31P) and other nuclei probe metabolism of epilepsy, but are less useful clinically. • There is potential for assessing the of drug mode of action and efficacy through 13C carbon metabolite measurements, while changes in sodium homeostasis resulting from seizure activity may be detected with 23Na MRS.
Resumo:
Objectives: To evaluate the validity, reliability and responsiveness of EDC using the WOMAC® NRS 3.1 Index on Motorola V3 mobile phones. ---------- Methods: Patients with osteoarthritis (OA) undergoing primary unilateral hip or knee joint replacement surgery were assessed pre-operatively and 3-4 months post-operatively. Patients completed the WOMAC® Index in paper (p-WOMAC®) and electronic (m-WOMAC®) format in random order. ---------- Results: 24 men and 38 women with hip and knee OA participated and successfully completed the m-WOMAC® questionnaire. Pearson correlations between the summated total index scores for the p-WOMAC® and m-WOMAC® pre- and post-surgery were 0.98 and 0.99 (p<0.0001). There was no clinically important or statistically significant between-method difference in the adjusted total summated scores, pre- and post-surgery (adjusted mean difference = 4.44, p = 0.474 and 1.73, p = 0.781). Internal consistency estimates of m-WOMAC® reliability were 0.87 – 0.98. The m-WOMAC® detected clinically important, statistically significant (p<0.0001) improvements in pain, stiffness, function and total index score. ---------- Conclusions: Sixty-two patients with hip and knee OA successfully completed EDC by Motorola V3 mobile phone using the m-WOMAC® NRS3.1 Index; completion times averaging only 1-1.5 minutes longer than the p-WOMAC® Index. Data were successfully and securely transmitted from patients in Australia to a server in the USA. There was close agreement and no significant differences between m-WOMAC® and p-WOMAC® scores. This study confirms the validity, reliability and responsiveness of the Exco InTouch engineered, Java-based m-WOMAC® Index application. EDC with the m-WOMAC® Index provides unique opportunities for using quantitative measurement in clinical research and practice.
Resumo:
Background and purpose Our aim was to prove in an animal model that the use of HA paste at the cement-bone interface in the acetabulum would improve fixation. We examined, in sheep, the effect of interposing a layer of hydroxyapatite cement around the periphery of a polyethylene socket prior to fixing it using polymethylemethacrylate (PMMA). Methods We made a randomized study involving 22 sheep to test whether the application of BoneSource hydroxyapatite material to the surface of the ovine acetabulum prior to cementing a polyethylene cup at hip arthroplasty improved the fixation and the nature of the interface. We studied the gross radiographical appearance of the implant-bone interface and the histological appearance at the interface. Results There were more radiolucencies evident in the control group. Histologically, only sheep randomized into the BoneSource group exhibited a fully osseointegrated interface. Use of the hydroxyapatite material did not confer any detrimental effects. In some cases the material appeared to have been fully resorbed. When the material was evident on histological section, it was incorporated into an osseointegrated interface. There was no giant cell reaction present in any case. There was no evidence of migration of BoneSource to the articulation. Interpretation The application of HA material prior to cementation of a socket produced an improved interface. The technique may be useful in man with to extend the longevity of the cemented implant by protecting the socket interface from the effect of hydrodynamic fluid flow and particulate debris.
Resumo:
This paper proposes a security architecture for the basic cross indexing systems emerging as foundational structures in current health information systems. In these systems unique identifiers are issued to healthcare providers and consumers. In most cases, such numbering schemes are national in scope and must therefore necessarily be used via an indexing system to identify records contained in pre-existing local, regional or national health information systems. Most large scale electronic health record systems envisage that such correlation between national healthcare identifiers and pre-existing identifiers will be performed by some centrally administered cross referencing, or index system. This paper is concerned with the security architecture for such indexing servers and the manner in which they interface with pre-existing health systems (including both workstations and servers). The paper proposes two required structures to achieve the goal of a national scale, and secure exchange of electronic health information, including: (a) the employment of high trust computer systems to perform an indexing function, and (b) the development and deployment of an appropriate high trust interface module, a Healthcare Interface Processor (HIP), to be integrated into the connected workstations or servers of healthcare service providers. This proposed architecture is specifically oriented toward requirements identified in the Connectivity Architecture for Australia’s e-health scheme as outlined by NEHTA and the national e-health strategy released by the Australian Health Ministers.
Resumo:
How does a digitally mediated environment work towards the ongoing support of the Hip Hop landscape present in the work of Jonzi D productions UK National Tour of "Markus the Sadist"
Resumo:
Obese children move less and with greater difficulty than normal-weight counterparts but expend comparable energy. Increased metabolic costs have been attributed to poor biomechanics but few studies have investigated the influence of obesity on mechanical demands of gait. This study sought to assess three-dimensional lower extremity joint powers in two walking cadences in 28 obese and normal-weight children. 3D-motion analysis was conducted for five trials of barefoot walking at self-selected and 30% greater than self-selected cadences. Mechanical power was calculated at the hip, knee, and ankle in sagittal, frontal and transverse planes. Significant group differences were seen for all power phases in the sagittal plane, hip and knee power at weight acceptance and hip power at propulsion in the frontal plane, and knee power during mid-stance in the transverse plane. After adjusting for body weight, group differences existed in hip and knee power phases at weight acceptance in sagittal and frontal planes, respectively. Differences in cadence existed for all hip joint powers in the sagittal plane and frontal plane hip power at propulsion. Frontal plane knee power at weight acceptance and sagittal plane knee power at propulsion were significantly different between cadences. Larger joint powers in obese children contribute to difficulty performing locomotor tasks, potentially decreasing motivation to exercise.
Resumo:
Background The purpose of this study was to provide a detailed evaluation of adherence to nutrition supplements by patients with a lower limb fracture. Methods These descriptive data are from 49 nutritionally“ at-risk” patients aged 70+ years admitted to the hospital after a fall-related lower limb fracture and allocated to receive supplementation as part of a randomized, controlled trial. Supplementation commenced on day 7 and continued for 42 days. Prescribed volumes aimed to meet 45% of individually estimated theoretical energy requirements to meet the shortfall between literature estimates of energy intake and requirements. The supplement was administered by nursing staff on medication rounds in the acute or residential care settings and supervised through thrice-weekly home visits postdischarge. Results Median daily percent of the prescribed volume of nutrition supplement consumed averaged over the 42 days was 67% (interquartile range [IQR], 31–89, n = 49). There was no difference in adherence for gender, accommodation, cognition, or whether the supplement was self-administered or supervised. Twenty-three participants took some supplement every day, and a further 12 missed <5 days. For these 35 “nonrefusers,” adherence was 82% (IQR, 65–93), and they lost on average 0.7% (SD, 4.0%) of baseline weight over the 6 weeks of supplementation compared with a loss of 5.5% (SD, 5.4%) in the “refusers” (n = 14, 29%), p = .003. Conclusions We achieved better volume and energy consumption than previous studies of hip fracture patients but still failed to meet target supplement volumes prescribed to meet 45% of theoretical energy requirements. Clinicians should consider alternative methods of feeding such as a nasogastric tube, particularly in those patients where adherence to oral nutrition supplements is poor and dietary intake alone is insufficient to meet estimated energy requirements.
Resumo:
One of the main causes of above knee or transfemoral amputation (TFA) in the developed world is trauma to the limb. The number of people undergoing TFA due to limb trauma, particularly due to war injuries, has been increasing. Typically the trauma amputee population, including war-related amputees, are otherwise healthy, active and desire to return to employment and their usual lifestyle. Consequently there is a growing need to restore long-term mobility and limb function to this population. Traditionally transfemoral amputees are provided with an artificial or prosthetic leg that consists of a fabricated socket, knee joint mechanism and a prosthetic foot. Amputees have reported several problems related to the socket of their prosthetic limb. These include pain in the residual limb, poor socket fit, discomfort and poor mobility. Removing the socket from the prosthetic limb could eliminate or reduce these problems. A solution to this is the direct attachment of the prosthesis to the residual bone (femur) inside the residual limb. This technique has been used on a small population of transfemoral amputees since 1990. A threaded titanium implant is screwed in to the shaft of the femur and a second component connects between the implant and the prosthesis. A period of time is required to allow the implant to become fully attached to the bone, called osseointegration (OI), and be able to withstand applied load; then the prosthesis can be attached. The advantages of transfemoral osseointegration (TFOI) over conventional prosthetic sockets include better hip mobility, sitting comfort and prosthetic retention and fewer skin problems on the residual limb. However, due to the length of time required for OI to progress and to complete the rehabilitation exercises, it can take up to twelve months after implant insertion for an amputee to be able to load bear and to walk unaided. The long rehabilitation time is a significant disadvantage of TFOI and may be impeding the wider adoption of the technique. There is a need for a non-invasive method of assessing the degree of osseointegration between the bone and the implant. If such a method was capable of determining the progression of TFOI and assessing when the implant was able to withstand physiological load it could reduce the overall rehabilitation time. Vibration analysis has been suggested as a potential technique: it is a non destructive method of assessing the dynamic properties of a structure. Changes in the physical properties of a structure can be identified from changes in its dynamic properties. Consequently vibration analysis, both experimental and computational, has been used to assess bone fracture healing, prosthetic hip loosening and dental implant OI with varying degrees of success. More recently experimental vibration analysis has been used in TFOI. However further work is needed to assess the potential of the technique and fully characterise the femur-implant system. The overall aim of this study was to develop physical and computational models of the TFOI femur-implant system and use these models to investigate the feasibility of vibration analysis to detect the process of OI. Femur-implant physical models were developed and manufactured using synthetic materials to represent four key stages of OI development (identified from a physiological model), simulated using different interface conditions between the implant and femur. Experimental vibration analysis (modal analysis) was then conducted using the physical models. The femur-implant models, representing stage one to stage four of OI development, were excited and the modal parameters obtained over the range 0-5kHz. The results indicated the technique had limited capability in distinguishing between different interface conditions. The fundamental bending mode did not alter with interfacial changes. However higher modes were able to track chronological changes in interface condition by the change in natural frequency, although no one modal parameter could uniquely distinguish between each interface condition. The importance of the model boundary condition (how the model is constrained) was the key finding; variations in the boundary condition altered the modal parameters obtained. Therefore the boundary conditions need to be held constant between tests in order for the detected modal parameter changes to be attributed to interface condition changes. A three dimensional Finite Element (FE) model of the femur-implant model was then developed and used to explore the sensitivity of the modal parameters to more subtle interfacial and boundary condition changes. The FE model was created using the synthetic femur geometry and an approximation of the implant geometry. The natural frequencies of the FE model were found to match the experimental frequencies within 20% and the FE and experimental mode shapes were similar. Therefore the FE model was shown to successfully capture the dynamic response of the physical system. As was found with the experimental modal analysis, the fundamental bending mode of the FE model did not alter due to changes in interface elastic modulus. Axial and torsional modes were identified by the FE model that were not detected experimentally; the torsional mode exhibited the largest frequency change due to interfacial changes (103% between the lower and upper limits of the interface modulus range). Therefore the FE model provided additional information on the dynamic response of the system and was complementary to the experimental model. The small changes in natural frequency over a large range of interface region elastic moduli indicated the method may only be able to distinguish between early and late OI progression. The boundary conditions applied to the FE model influenced the modal parameters to a far greater extent than the interface condition variations. Therefore the FE model, as well as the experimental modal analysis, indicated that the boundary conditions need to be held constant between tests in order for the detected changes in modal parameters to be attributed to interface condition changes alone. The results of this study suggest that in a clinical setting it is unlikely that the in vivo boundary conditions of the amputated femur could be adequately controlled or replicated over time and consequently it is unlikely that any longitudinal change in frequency detected by the modal analysis technique could be attributed exclusively to changes at the femur-implant interface. Therefore further development of the modal analysis technique would require significant consideration of the clinical boundary conditions and investigation of modes other than the bending modes.
Resumo:
Changes in stride characteristics and gait rhythmicity characterize gait in Parkinson's disease and are widely believed to contribute to falls in this population. However, few studies have examined gait in PD patients who fall. This study reports on the complexities of walking in PD patients who reported falling during a 12-month follow-up. Forty-nine patients clinically diagnosed with idiopathic PD and 34 controls had their gait assessed using three-dimensional motion analysis. Of the PD patients, 32 (65%) reported at least one fall during the follow-up compared with 17 (50%) controls. The results showed that PD patients had increased stride timing variability, reduced arm swing and walked with a more stooped posture than controls. Additionally, PD fallers took shorter strides, walked slower, spent more time in double-support, had poorer gait stability ratios and did not project their center of mass as far forward of their base of support when compared with controls. These stride changes were accompanied by a reduced range of angular motion for the hip and knee joints. Relative to walking velocity, PD fallers had increased mediolateral head motion compared with PD nonfallers and controls. Therefore, head motion could exceed “normal” limits, if patients increased their walking speed to match healthy individuals. This could be a limiting factor for improving gait in PD and emphasizes the importance of clinically assessing gait to facilitate the early identification of PD patients with a higher risk of falling.
Resumo:
Rationale, aims and objectives: Patient preference for interventions aimed at preventing in-hospital falls has not previously been investigated. This study aims to contrast the amount patients are willing to pay to prevent falls through six intervention approaches. ----- ----- Methods: This was a cross-sectional willingness-to-pay (WTP), contingent valuation survey conducted among hospital inpatients (n = 125) during their first week on a geriatric rehabilitation unit in Queensland, Australia. Contingent valuation scenarios were constructed for six falls prevention interventions: a falls consultation, an exercise programme, a face-to-face education programme, a booklet and video education programme, hip protectors and a targeted, multifactorial intervention programme. The benefit to participants in terms of reduction in risk of falls was held constant (30% risk reduction) within each scenario. ----- ----- Results: Participants valued the targeted, multifactorial intervention programme the highest [mean WTP (95% CI): $(AUD)268 ($240, $296)], followed by the falls consultation [$215 ($196, $234)], exercise [$174 ($156, $191)], face-to-face education [$164 ($146, $182)], hip protector [$74 ($62, $87)] and booklet and video education interventions [$68 ($57, $80)]. A ‘cost of provision’ bias was identified, which adversely affected the valuation of the booklet and video education intervention. ----- ----- Conclusion: There may be considerable indirect and intangible costs associated with interventions to prevent falls in hospitals that can substantially affect patient preferences. These costs could substantially influence the ability of these interventions to generate a net benefit in a cost–benefit analysis.
Resumo:
Previous research has suggested that perceptual-motor difficulties may account for obese children's lower motor competence; however, specific evidence is currently lacking. Therefore, this study examined the effect of altered visual conditions on spatiotemporal and kinematic gait parameters in obese versus normal-weight children. Thirty-two obese and normal-weight children (11.2 ± 1.5 years) walked barefoot on an instrumented walkway at constant self-selected speed during LIGHT and DARK conditions. Three-dimensional motion analysis was performed to calculate spatiotemporal parameters, as well as sagittal trunk segment and lower extremity joint angles at heel-strike and toe-off. Self-selected speed did not significantly differ between groups. In the DARK condition, all participants walked at a significantly slower speed, decreased stride length, and increased stride width. Without normal vision, obese children had a more pronounced increase in relative double support time compared to the normal-weight group, resulting in a significantly greater percentage of the gait cycle spent in stance. Walking in the DARK, both groups showed greater forward tilt of the trunk and restricted hip movement. All participants had increased knee flexion at heel-strike, as well as decreased knee extension and ankle plantarflexion at toe-off in the DARK condition. The removal of normal vision affected obese children's temporal gait pattern to a larger extent than that of normal-weight peers. Results suggest an increased dependency on vision in obese children to control locomotion. Next to the mechanical problem of moving excess mass, a different coupling between perception and action appears to be governing obese children's motor coordination and control.
Resumo:
There has been no direct attempt to evaluate whether gait performed overground and on a treadmill is the same for lower limb amputees. A multiple case study approach was adopted to explore the degenerate movement behavior displayed by three male amputees. Participants walked overground at a self-selected preferred pace and when this speed was enforced on a treadmill (50 stride cycles per condition). The extremities of motion (i.e., maximum flexion) for the hip and knee joints differed between conditions (0.2–3.8°). For two participants, the temporal asymmetry of gait was reduced on the treadmill. Initial data suggest that research on amputees simulating overground walking on a treadmill might need to be interpreted with some caution.