944 resultados para High-Functioning ASD


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The high penetration of distributed energy resources (DER) in distribution networks and the competitiveenvironment of electricity markets impose the use of new approaches in several domains. The networkcost allocation, traditionally used in transmission networks, should be adapted and used in the distribu-tion networks considering the specifications of the connected resources. The main goal is to develop afairer methodology trying to distribute the distribution network use costs to all players which are usingthe network in each period. In this paper, a model considering different type of costs (fixed, losses, andcongestion costs) is proposed comprising the use of a large set of DER, namely distributed generation(DG), demand response (DR) of direct load control type, energy storage systems (ESS), and electric vehi-cles with capability of discharging energy to the network, which is known as vehicle-to-grid (V2G). Theproposed model includes three distinct phases of operation. The first phase of the model consists in aneconomic dispatch based on an AC optimal power flow (AC-OPF); in the second phase Kirschen’s andBialek’s tracing algorithms are used and compared to evaluate the impact of each resource in the net-work. Finally, the MW-mile method is used in the third phase of the proposed model. A distributionnetwork of 33 buses with large penetration of DER is used to illustrate the application of the proposedmodel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A clinical trial pilot study, double-blinded, randomized, and controlled with a placebo to assess the effectiveness of oral doxycycline (200 mg, single dose) in preventing leptospirosis after high exposure to potentially contamined water was performed in São Paulo, SP, Brazil. Confirmed cases were defined as those with leptospira IgM antibody and symptoms; asymptomatic cases were those presenting with IgM antibodies but no symptoms; and suspected cases were individuals with symptoms but no IgM antibody. Forty subjects were given doxycycline and 42 were given placebo. In the drug-treated group there were 2 confirmed cases, 11 asymptomatic cases, and 6 suspected cases. In the placebo group there were 5 confirmed, 6 symptomatic, and 5 suspected cases. Even though we found a protective association of doxycycline for confirmed leptospirosis cases (RR = 2.3) and seroconversion only (RR = 2.0), the association was not statistically significant because of the small number of individuals enrolled in this pilot study. We observed that the 22% of the volunteers already had IgM antibodies to leptospirosis at the first sampling. Finally, the attack rate to confirmed, asymptomatic, and suspected cases of Leptospirosis was 8.5%, 22%, and 13%, respectively, in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presented at Faculdade de Ciências e Tecnologias, Universidade de Lisboa, to obtain the Master Degree in Conservation and Restoration of Textiles

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O Sector eléctrico possui uma grande importância nas sociedades modernas. Dados os elevados custos de produção de energia e o grande impacto que esta tem na nossa economia e na sociedade, em geral, a utilização mais eficiente da energia é um factor fulcral. Com a evolução da electrónica e consequente aumento das capacidades dos computadores, as protecções eléctricas são cada vez mais eficazes e com índices de fiabilidade mais elevados, algo muito importante em instalações de elevado custo de investimento e manutenção. No entanto, o seu bom funcionamento está dependente do correcto dimensionamento das protecções e de uma análise técnica capaz de prever necessidades futuras. Após uma breve introdução no capítulo 1 é efectuado no capítulo 2 um breve estudo de protecções eléctricas e o seu estado de arte. Nos Capítulos 3 e 4 é efectuado o dimensionamento e estudo da selectividade das protecções de grupo de Alternador e Transformador escolhidos para a nova central de cogeração da refinaria de Matosinhos da Galp. No presente estudo foram apenas consideradas as protecções típicas de alternador e apenas a protecção diferencial do transformador. Todas as protecções foram dimensionadas com base no tutorial de protecções de geradores do IEE e com informação referente ao manual de instruções do relé G60 da GE industrial systems, o DTP-B da GE multilin e o ELIN Power Plant Automation. No Capítulo 5 é demonstrada a importância da análise Safety Instruments Systems (SIS), o seu modo de aplicação e necessidade de implementação em locais industriais como o caso em estudo. Por último, é efectuado um pequeno estudo económico onde é efectuada a comparação dos custos dos diversos equipamentos, protecções e manutenções efectuadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Biotecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta dissertação apresenta o trabalho realizado no âmbito da unidade curricular de Tese/Dissertação (TEDI), do 2º ano, do Mestrado em Engenharia Eletrotécnica e de Computadores no ramo de Automação e Sistemas. O principal objetivo desta dissertação consiste no desenvolvimento de um sistema que permita efetuar a deteção de um determinado número de anomalias num sinal eletrocardiográfico. O coração é um dos órgãos mais importantes do corpo humano. É ele que recebe e bombeia o sangue pelo organismo. Isto é, recebe sangue pobre em oxigénio, encaminha-o para os pulmões onde será enriquecido em oxigénio. O sangue enriquecido em oxigénio é então encaminhado novamente para o coração que será enviado para todas as partes do corpo humano. O eletrocardiograma desempenha um papel fundamental de modo a diagnosticar eventuais anomalias no correto funcionamento do coração. Estas anomalias podem dever-se a diversos fatores como tabaco, colesterol, pressão sanguínea alta ou diabetes entre outros. As anomalias associadas ao ritmo cardíaco são denominadas de arritmias. As arritmias são fundamentalmente originadas pela alteração da frequência ou do ritmo cardíaco. Utilizando a lógica difusa, pretendeu-se desenvolver um sistema que fizesse a identificação de um determinado número de tipos de batimentos entre os quais: o bloqueio do ramo esquerdo (LBBB), bloqueio do ramo direito (RBBB), contração prematura ventricular (VPC) e contração prematura auricular (APC). Todos os desenvolvimentos efetuados, a nível de programação, são neste documento relatados de forma a constituírem um possível guia para a utilização deste tipo de sistemas. Mais ainda, descrevem-se nele toda a pesquisa efetuada e as alternativas de desenvolvimento selecionadas. O Sistema de Deteção de Arritmias (SDA) desenvolvido mostrou-se eficaz desde que o utilizador consiga identificar corretamente os parâmetros que lhe são pedidos. A interface gráfica desenvolvida permitiu também uma maior facilidade durante a análise do sinal eletrocardiográfico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No âmbito do desenvolvimento da dissertação do Mestrado de Engenharia Eletrotécnica – Sistemas Elétricos de Energia, surgiu a oportunidade de participar no desenvolvimento de um projeto integrante numa subestação de energia. O presente caso de estudo tem em vista a resolução de condicionantes na conceção desta subestação, tais como cumprir requisitos estéticos projetando todo o tipo de equipamentos dentro de edifícios, a ventilação das salas de transformação assim como insonorização de todo o ruído produzido de forma a cumprir os limites legais e não perturbar a vizinhança. A presente subestação de energia está situada numa zona urbana da cidade de Leiria, localidade de Parceiros, dando origem ao nome Subestação de Energia de Parceiros. Esta subestação pertence ao cliente Energias de Portugal, conhecida como EDP, e visa o melhoramento da distribuição do serviço eléctrico. As tradicionais subestações de energia, com aparência bastante desenquadrada dos meios urbanos, representam um entrave ao nível da aproximação destes centros de produção energética às zonas urbanas, comprometendo a melhoria da rede elétrica. Desta forma, foi implementada a tecnologia Gas-Insolated Switchgear e permite o enquadramento destes centros energéticos em zonas urbanas, constituindo mais um edifício urbano na zona onde se insere. Esta substitui os convencionais barramentos existentes nos Parques Exteriores de Aparelhagem das subestações e apresenta-se com dimensões muito reduzidas quando comparadas com as estruturas instaladas nestes parques. Dado que esta tecnologia é desenvolvida no sentido de permitir a construção destes centros energéticos em zonas urbanas, podem ser alojadas dentro de edifícios produzindo assim vantagens ao nível estético, não perturbando a paisagem. Dado que os principais equipamentos de funcionamento na subestação de Parceiros, nomeadamente o Transformador de Potência, se encontram instalados num edifício completamente fechado, foram construídas duas salas de ventilação, na parte superior deste edifício, cada uma adjacente a uma sala de transformação. O transformador instalado possui elevadas dimensões, pesando 53000 kg e contendo 11000 kg de óleo que em estado normal de funcionamento circula por quase todo o interior da máquina a elevadas temperaturas, provocando um aquecimento elevado no interior do edifício o que condiciona o bom funcionamento do transformador. Para ultrapassar esta condicionante foi realizado um estudo de um sistema de ventilação capaz de avaliar e controlar os valores térmicos existentes e proceder à circulação de ar, que será movimentado ou bloqueado, recorrendo a um sistema autónomo, mantendo a temperatura ideal nas salas de transformação. Este autómato é o cérebro de toda a cadeia lógica que, mediante as leituras efetuadas irá dar ordens de atuação aos diversos equipamentos. Apesar dos TP estarem protegidos dentro do edifício, estes produzem um maior ruído. A necessidade da existência do referido sistema de ventilação das divisões de funcionamento destas máquinas, implica a utilização de aparelhos que, apesar da sua evolução tecnológica os torna cada vez menos ruidosos, mas geram sempre alguma perturbação, o que pode representar um problema no cumprimento do regulamento geral do ruído.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ammonia is an important gas in many power plants and industrial processes so its detection is of extreme importance in environmental monitoring and process control due to its high toxicity. Ammonia’s threshold limit is 25 ppm and the exposure time limit is 8 h, however exposure to 35 ppm is only secure for 10 min. In this work a brief introduction to ammonia aspects are presented, like its physical and chemical properties, the dangers in its manipulation, its ways of production and its sources. The application areas in which ammonia gas detection is important and needed are also referred: environmental gas analysis (e.g. intense farming), automotive-, chemical- and medical industries. In order to monitor ammonia gas in these different areas there are some requirements that must be attended. These requirements determine the choice of sensor and, therefore, several types of sensors with different characteristics were developed, like metal oxides, surface acoustic wave-, catalytic-, and optical sensors, indirect gas analyzers, and conducting polymers. All the sensors types are described, but more attention will be given to polyaniline (PANI), particularly to its characteristics, syntheses, chemical doping processes, deposition methods, transduction modes, and its adhesion to inorganic materials. Besides this, short descriptions of PANI nanostructures, the use of electrospinning in the formation of nanofibers/microfibers, and graphene and its characteristics are included. The created sensor is an instrument that tries to achieve a goal of the medical community in the control of the breath’s ammonia levels being an easy and non-invasive method for diagnostic of kidney malfunction and/or gastric ulcers. For that the device should be capable to detect different levels of ammonia gas concentrations. So, in the present work an ammonia gas sensor was developed using a conductive polymer composite which was immobilized on a carbon transducer surface. The experiments were targeted to ammonia measurements at ppb level. Ammonia gas measurements were carried out in the concentration range from 1 ppb to 500 ppb. A commercial substrate was used; screen-printed carbon electrodes. After adequate surface pre-treatment of the substrate, its electrodes were covered by a nanofibrous polymeric composite. The conducting polyaniline doped with sulfuric acid (H2SO4) was blended with reduced graphene oxide (RGO) obtained by wet chemical synthesis. This composite formed the basis for the formation of nanofibers by electrospinning. Nanofibers will increase the sensitivity of the sensing material. The electrospun PANI-RGO fibers were placed on the substrate and then dried at ambient temperature. Amperometric measurements were performed at different ammonia gas concentrations (1 to 500 ppb). The I-V characteristics were registered and some interfering gases were studied (NO2, ethanol, and acetone). The gas samples were prepared in a custom setup and were diluted with dry nitrogen gas. Electrospun nanofibers of PANI-RGO composite demonstrated an enhancement in NH3 gas detection when comparing with only electrospun PANI nanofibers. Was visible higher range of resistance at concentrations from 1 to 500 ppb. It was also observed that the sensor had stable, reproducible and recoverable properties. Moreover, it had better response and recovery times. The new sensing material of the developed sensor demonstrated to be a good candidate for ammonia gas determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevalence of TT virus (TTV) infection was investigated by Polymerase Chain Reaction (PCR) in low- (blood donors and healthy children/adolescents) and high-risk (hemophiliacs) groups from São Paulo, Brazil. Primers based on the untranslated region (UTR) of the viral genome proved to be much more ubiquitous, leading to much higher frequencies for both groups ( > or = 81%) than the earlier N22-PCR directed to the open reading frame 1 (blood donors, 5.5%, and hemophiliacs, 42.3%). The UTR-PCR also revealed an interesting profile for healthy children/adolescents: very high prevalence at the early years and significant decrease in male teenagers. The N22-PCR, in turn, demonstrated higher frequency in hemophiliacs treated with fresh blood products (58%), than in those treated with virus-inactivated clotting factors (9.4%) and blood donors (5.5%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the presence of the Hepatitis G Virus on a population of blood donors from São Paulo, Brazil and to evaluate its association to sociodemographic variables. Two RT-PCR systems targeting the putative 5'NCR and NS3 regions were employed and the former has shown a higher sensitivity. The observed prevalence of HGV-RNA on 545 blood donors was 9.7% (CI 95% 7.4;12.5). Statistical analysis depicted an association with race/ethnicity, black and mulatto donors being more frequently infected; and also with years of education, less educated donors presenting higher prevalences. No association was observed with other sociodemographic parameters as age, gender, place of birth and of residence. DNA sequencing of nine randomly chosen isolates demonstrated the presence of genotypes 1, 2 and 3 among our population but clustering of these Brazilian isolates was not detected upon phylogenetic analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been well demonstrated the relationship between the infection with high-risk human papillomavirus (HPVs) genotypes and cervical cancer. In Northeastern Argentina a high incidence of this pathology has been described and therefore a high prevalence of HPV infection is expected. In order to identify HPV genotypes associated with malignant and pre-malignant cervical lesions present in the area, 53 ecto-endo cervical cell specimens obtained from women with cytohistological alterations were studied by a PCR-RFLP technique. Out of 53 patients, 34 (64.2%) were positive for HPV infection, being HPV-16 (32.3%) the most frequently found genotype, followed by HPV-58 (14.7%), -6, -18 and -45 (5.9%), -33, -52, -53, -54, -56, -66, -MM4 and -LVX100 (2.9%). Also 5 cases of infection caused by multiple genotypes were found, which corresponded to 14.7% of the positive cases. Results indicate that besides HPV-16 and -18, the most prevalent high-risk HPV genotypes worldwide, others like -45 and -58 as well as co-infection cases are frequent between women of Northeastern Argentina, and a particular attention should be paid to this circumstance because it could be an epidemiological feature of regional importance and a useful information for a future vaccination program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bartonellosis or Carrion's disease is endemic in some regions of Peru, classically found in the inter-Andean valleys located between 500 and 3200 meters above sea level. We report the case of a 43 year-old male patient, farmer, who was born in the Pichanaki district (Chanchamayo, Junin), located in the High Forest of Peru. He presented with disseminated, raised, erythematous cutaneous lesions, some of which bled. The distribution of these lesions included the nasal mucosa and penile region. Additionally subcutaneous nodules were distributed over the trunk and extremities. Hematologic exams showed a moderate anemia. Serologic studies for HIV and Treponema pallidum were negative. The histopathologic results of two biopsies were compatible with Peruvian wart. Oral treatment with ciprofloxacin (500 mg BID) was begun. Over 10 days, the patient showed clinical improvement. This is the first report of a confirmed case of bartonellosis in the eruptive phase originating from the Peruvian High Forest, showing the geographical expansion of the Carrion's disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Atrial septal defects (ASD) are among the most common congenital anomalies and account for 10% of congenital heart disease in the pediatric age-group and 30% in adults. Closure is indicated when there is evidence of hemodynamic significance or after a paradoxical embolic event. Ten years ago, percutaneous closure became the treatment of choice in our center for all patients with a clear indication and favorable anatomy. In this paper we report the experience of this first decade. OBJECTIVE: To assess the short- and long-term results of our ten-year experience with percutaneous closure of atrial septal defects. METHODS: We studied retrospectively all patients with ASD treated with a percutaneous approach between November 1998 and December 2008. The pediatric age-group consisted of patients younger than 19 years old. Demographic data, clinical indications, minor and major complication rates, success rate and long-term outcome were assessed. RESULTS: In the first ten years of experience 510 patients, of whom 166 were in the pediatric group, were treated in our center by a team of adult and pediatric cardiologists. The overall success rate of the procedure was 98% (97.5% in ASD and 99.5% in patent foramen ovale (PFO). The minor complication rate was 3% (3.4% in ASD and 2% in PFO). The most frequent complication was supraventricular tachycardia. The major complication rate was 1.2% (0.6% in ASD and 2% in PFO). Two patients developed cardiac tamponade due to hemopericardium that was resolved by pericardiocentesis, without need for surgery. One patient had an arterial pseudoaneurysm corrected by vascular surgery. There was no device embolization and no need for urgent surgery in this population. During follow-up two patients had recurrence of ischemic stroke, one had a transient ischemic attack and another had a hemorrhagic stroke. Mortality was 0.6% (0.6% in ASD and 0.5% in PFO). There were no in-hospital deaths. During follow-up there were two deaths, both in the adult group. DISCUSSION AND CONCLUSION: In this population the success rate was high and most of the complications were minor. The results of this collaboration between adult and pediatric cardiologists in the first ten years of activity confirm the safety and efficacy of percutaneous closure of septal defects, when there is careful patient selection and a standardized technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anti-Toxoplasma IgG-avidity was determined in 168 serum samples from IgG- and IgM-positive pregnant women at various times during pregnancy, in order to evaluate the predictive value for risk of mother-to-child transmission in a single sample, taking the limitations of conventional serology into account. The neonatal IgM was considered the serologic marker of transmission. Fluorometric tests for IgG, IgM (immunocapture) and IgG-avidity were performed. Fifty-one of the 128 pregnant women tested gave birth in the hospital and neonatal IgM was obtained. The results showed 32 (62.75%) pregnant women having high avidity, IgM indexes between 0.6 and 2.4, and no infected newborn. Nineteen (37.25%) had low or inconclusive avidity, IgM indexes between 0.6 and 11.9, and five infected newborns and one stillbirth. In two infected newborns and the stillbirth maternal IgM indexes were low and in one infected newborn the only maternal parameter that suggested fetal risk was IgG-avidity. In the present study, IgG-avidity performed in single samples from positive IgM pregnant women helped to determine the risk of transmission at any time during pregnancy, especially when the indexes of the two tests were analysed with respect to gestational age. This model may be less expensive in developing countries where there is a high prevalence of infection than the follow-up of susceptible mothers until childbirth with monthly serology, and it creates a new perspective for the diagnosis of congenital toxoplasmosis.