975 resultados para Heat Flux Measurement
Resumo:
This paper presents a measurement of the charged current interaction rate of the electron neutrino beam component of the beam above 1.5 GeV using the large fiducial mass of the T2K π0 detector. The predominant portion of the νe flux (∼85%) at these energies comes from kaon decays. The measured ratio of the observed beam interaction rate to the predicted rate in the detector with water targets filled is 0.89 ± 0.08 (stat.) ± 0.11 (sys.), and with the water targets emptied is 0.90 ± 0.09 (stat.) ± 0.13 (sys.). The ratio obtained for the interactions on water only from an event subtraction method is 0.87 ± 0.33 (stat.) ± 0.21 (sys.). This is the first measurement of the interaction rate of electron neutrinos on water, which is particularly of interest to experiments with water Cherenkov detectors.
Resumo:
There are several heat and mass diffusion problems which affect to the IFC chamber design. New simulation models and experiments are needed to take into account the extreme conditions due to ignition pulses and neutron flux
Resumo:
Although there are numerous accurate measuring methods to determine soil moisture content in a spot, until very recently there were no precise in situ and in real time methods that were able to measure soil moisture content along a line. By means of the Distributed Fiber Optic Temperature Measurement method or DFOT, the temperature in 0.12 m intervals and long distances (up to 10,000 m) with a high time frequency and an accuracy of +0.2º C is determined. The principle of temperature measurement along a fiber optic cable is based on the thermal sensitivity of the relative intensities of backscattered photons that arise from collisions with electrons in the core of the glass fiber. A laser pulse, generated by the DTS unit, traversing a fiber optic cable will result in backscatter at two frequencies. The DTS quantifies the intensity of these backscattered photons and elapsed time between the pulse and the observed returned light. The intensity of one of the frequencies is strongly dependent on the temperature at the point where the scattering process occurred. The computed temperature is attributed to the position along the cable from which the light was reflected, computed from the time of travel for the light.
Resumo:
Aunque se conocen muchos métodos precisos para medidas de humedad puntuales, hasta hace muy poco, no existían métodos in situ para la medida del contenido de humedad a escala de metros o de kilómetros, importantes cuando pensamos a nivel de cuenca hidrográfica. La fibra óptica ha sido muy utilizada en el área de las comunicaciones. Sin embargo, entre sus aplicaciones más recientes, destaca la de su uso para medir la temperatura incluso en grandes distancias (hasta 10 km) y con una alta frecuencia temporal, lo que ha abierto un amplio abanico de posibilidades muy importantes en el seguimiento medioambiental (Selker et al. 2006a; 2006b, Tyler et al. 2008; Westhoff et al., 2007; Freifeld et al., 2008). La precisión en la medida puede alcanzar ± 0,2ºC en una distancia de ± 25 cm. El método utilizado en los ensayos explicados en esta comunicación es el denominado “Distributed Fiber Optic Temperature Measurement” (medida distribuida de la temperatura con fibra óptica) o DFOT, que consiste en emitir un impulso óptico con láser y medir en el tiempo la señal reflejada en diferentes puntos de la fibra. Este método se ha utilizado en el estudio de filtraciones de minas abandonadas (Selker et al. 2006a) y en proyectos relacionados con el cambio climático, como en el estudio del deshielo en glaciares y balances hídricos en pequeñas cuencas (Selker et al. 2006b). Además, en medios porosos, se ha usado, con buenos resultados para la detección de rotura de diques en presas (Perzlmaier et al. 2004a y 2004b) y para la detección de entrada de agua en vertederos urbanos con cubierta vegetal (Weiss, 2003b). Imhoff et al. (2006) en su revisión de técnicas de medidas de contenido de agua en el suelo destaca el uso del “DFOT heat pulse method” (método DFOT del pulso de calor).