921 resultados para HECUBA GAP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Encyclopedia of Nanoscience and Nanotechnology® is the World's first encyclopedia ever published in the field of nanotechnology. The 10-volume Encyclopedia is an unprecedented single reference source that provides ideal introduction and overview of most recent advances and emerging new aspects of nanotechnology spanning from science to engineering to medicine. Although there are many books/handbook and journals focused on nanotechnology, no encyclopedic reference work has been published covering all aspects of nanoscale science and technology dealing with materials synthesis, processing, fabrication, probes, spectroscopy, physical properties, electronics, optics, mechanics, biotechnology, devices, etc. The Encyclopedia fills this gap to provide basic information on all fundamental and applied aspects of nanotechnology by drawing on two decades of pioneering research. It is the only scientific work of its kind since the beginning of the field of nanotechnology bringing together core knowledge and the very latest advances. It is written for all levels audience that allows non-scientists to understand the nanotechnology while providing up-to-date latest information to active scientists to experts in the field. This outstanding encyclopedia is an indispensable source for research professionals, technology investors and developers seeking the most up-to-date information on the nanotechnology among a wide range of disciplines from science to engineering to medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the percutaneous Achilles tendon sectioning technique using a large gauge needle for the correction of residual equinus of congenital clubfoot treated with the Ponseti method. Methods: Fifty-seven Achilles tendon sections were prospectively evaluated in thirty-nine patients with clubfoot, treated with the Ponseti method between July 2005 and December 2008. The tenotomy was performed percutaneously with a large gauge needle. Ultrasound scan was performed immediately after the section, to ascertain whether the tenotomy was complete, as well as stump separation. Results: There was complete tendon section in all cases, but the need to perform the section maneuver more than once was common, due to the persistence of the residual strands between tendon stumps. The Thompson test and dynamic ultrasound evaluation were able to detect incomplete tenotomies. The mean ultrasound measurement of the tendon gap was 5.70 +/- 2.23 mm. Two patients had abnormal bleeding, which was controlled by digital pressure and did not compromise foot perfusion. Conclusion: Percutaneous Achilles tendon sectioning with a needle proved to be efficient and safe to correct residual equinus of clubfoot treated with the Ponseti technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endothelial dysfunction has been linked to a decrease in nitric oxide (NO) bioavailability and attenuated endothelium-derived hyperpolarizing factor (EDHF)-mediated relaxation. The small (SK(Ca)) and intermediate (IK(Ca)) calcium-activated potassium channels play a key role in endothelium-dependent relaxation. Because the repressor element 1-silencing transcription factor (REST) negatively regulates IK(Ca) expression, we hypothesized that augmented REST and decreased IK(Ca) expression contributes to impaired endothelium-dependent vasodilation associated with hypertension. Acetylcholine (ACh) responses were slightly decreased in small mesenteric arteries from male stroke-prone spontaneously hypertensive rats (SHRSPs) versus arteries from Wistar Kyoto (WKY) rats. Incubation with N-nitro-L-arginine methyl ester (L-NAME; 100 mu mol/L) and indomethacin (100 mu mol/L) greatly impaired ACh responses in vessels from SHRSP. lberiotoxin (0.1 mu mol/L), which is a selective inhibitor of large-conductance K(Ca) (BK(Ca)) channels, did not modify EDHF-mediated vasodilation in SHRSP or WKY. UCL-1684 (0.1 mu mol/L.), which is a selective inhibitor of SKCa channels, almost abolished EDHF-mediated vasodilation in WKY and decreased relaxation in SHRSP. 1-((2-chlorophenyl)diphenylmethyl)-1H-pyrazole (TRAM-34; 10 mu mol/L) and charybdotoxin (0.1 mu mol/L), which are both IKCa inhibitors, produced a small decrease of EDHF relaxation in WKY but completely abrogated EDHF vasodilation in SHRSP. EDHF-mediated relaxant responses were completely abolished in both groups by simultaneous treatment with UCL-1684 and TRAM-34 or charybdotoxin. Relaxation to SK(Ca)/IK(Ca) channels agonist NS-309 was decreased in SHRSP arteries. The expression of SK(Ca) was decreased, whereas IK(Ca) was increased in SHRSP mesenteric arteries. REST expression was reduced in arteries from SHRSP. Vessels incubated with TRAM-34 (10 mu mol/L) for 24h displayed reduced REST expression and demonstrated no differences in IK(Ca). In conclusion, IK(Ca) channel upregulation, via decreased REST, seems to compensate deficient activity of SK(Ca) channels in the vasculature of spontaneously hypertensive rats. (Translational Research 2009; 154:183-193)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many studies have used genetic markers to understand global migration patterns of our species. However, there are only few studies of human migration on a local scale. We, therefore, researched migration dynamics in three Afro-Brazilian rural communities, using demographic data and ten Ancestry Informative Markers. In addition to the description of migration and marriage structures, we carried out genetic comparisons between the three populations, as well as between locals and migrants from each community. Genetic admixture analyses were conducted according to the gene-identity method, with Sub-Saharan Africans, Amerindians, and Europeans as parental populations. The three analyzed Afro-Brazilian rural communities consisted of 16% to 30% of migrants, most of them women. The age pyramid revealed a gap in the segment of men aged between 20 to 30 yrs. While endogamous marriages predominated, exogamous marriages were mainly patrilocal. Migration dynamics are apparently associated with matrimonial customs and other social practices of such communities. The impact of migration upon the populations` genetic composition was low but showed an increase in European alleles with a concomitant decrease in the Amerindian contribution. Admixture analysis evidenced a higher African contribution to the gene pool of the studied populations, followed by the contribution of Europeans and Amerindians, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate infection control practices among dentists in private and public practice. Design: Survey and cross-sectional analysis. Setting: Sertaozinho city, Brazil. Participants: All dentists who were currently working at the study city, and agreed to participate, resulting in a study population of 135 dentists. Methods: Participants were personally interviewed and variables were submitted to X(2) or Fisher`s exact test. Results: Hand washing before and after each patient was reported by 86.7% of dentists, but private practitioners used liquid soap and paper towels more often than their public colleagues (p<0.001). Most of the study population (97.8%) used gloves routinely during clinical sessions, but 8.2% reused them. Dry-heat was the main method employed for sterilisation of heat-stable devices by 80.0% of dentists, but adequate temperature and time of exposure was accomplished by only 32.1% of public and 70.0% of private professionals (p<0.001). Heat-sensitive devices were disinfected with an adequate substance by 60.0% of both affiliation dentists (p=0.908). Conclusions: There is a large gap between infection control recommendations and practices observed among the study population, and the situation is worse in public services. To reverse that situation, infection control issues must be openly debated by professional associations, dental schools and health authorities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the proliferative behavior of the corneal and limbal epithelia after debridement on the central region of the rabbit cornea. Methods: After scraping a circular epithelial area, 5 mm in diameter, in the center of the cornea, (3)H-thymidine ((3)H-TdR) was injected intravitreally, and the rabbits killed from 1 to 49 days afterward. The cornea, together with the adjacent conjunctiva, was processed for autoradiography. Results: The regenerating epithelium at the center of the cornea exhibited high frequencies of labeled nuclei when compared to controls. The mitotic indexes for the limbus were comparable in experimental and control eyes. The unique basal stratum of the limbal epithelium exhibited quick proliferation and vertical migration in all eyes. Cells that remained labeled for four weeks or more were observed throughout the corneal epithelium, including its basal stratum, and this did not depend on epithelial damage. Conclusion: Corneal epithelium wounds are healed by sliding and proliferation of cells surrounding the epithelial gap without any evidence for the participation of the limbal epithelium. Daughter cells labeled with (3)H-TdR were visualized in all layers of the corneal epithelium up to 7 weeks after the DNA precursor injection. However, at this long interval, the only labeled cells in the limbus were in the suprabasal layers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neutrophil influx is essential for corneal regeneration (Gan et al. 1999). KM+, a lectin from Artocarpus integrifolia, induces neutrophil migration (Santos-de-Oliveira et al. 1994). This study aims at investigating a possible effect of KM+ on corneal regeneration in rabbits. A 6,0-mm diameter area of debridement was created on the cornea of both eyes by mechanical scraping. The experimental eyes received drops of KM+ (2.5 mu g/ml) every 2 h, The control eyes received buffer, The epithelial wounded areas of the lectin-treated and untreated eyes were stained with fluorescein, photographed and measured, The animals were killed 12 h (group 1, n = 5), 24 h (group 2, n = 10) and 48 h (group 3, n = 5) after the scraping. The corneas were analysed histologically (haematoxylin and eosin and immunostaining for proliferation cell nuclear antigen, p&3, vascular endothelial growth factor, c-Met and laminin). No significant differences were found at the epithelial gap between treated and control eyes in the group 1. However, the number of neutrophils in the wounded area was significantly higher in treated eyes in this group. Three control and seven treated eyes were healed completely and only rare neutrophils persisted in the corneal stroma in group 2. No morphological distinction was observed between treated and control eyes in group 3. In treated corneas of group 2, there was an increase in immunostaining of factors involved in corneal healing compared to controls, Thus, topical application of KM+ may facilitate corneal epithelial wound healing in rabbits by means of a mechanism that involves increased influx of neutrophils into the wounded area induced by the lectin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Whenever the surgeon uses the stomach as an esophageal substitute, either one of two techniques is generally performed: total gastric transposition or gastric tube esophagoplasty. No existing reports compare the complications associated with these two surgical procedures. The purpose of this study is to review the authors` experience with total gastric transposition and verify whether this technique is superior to gastric tube esophagoplasty in children by comparing the main complications with those reported in the publications of gastric tubes esophagoplasties in the English language literature published in the last 38 years. A total of 35 children underwent total gastric transposition according to the classical technique. Most of these patients (27, or 77.1%) had long gap esophageal atresia. The most frequently observed complications were compared to those reported in nine studies of gastric tube esophagoplasty comprising 184 patients. Mortality and graft failure rates were also compared. Seven patients (20.0%) presented with leaks, all of which closed spontaneously. Six children were reoperated, three experienced gastric outlet obstruction secondary to axial torsion of the stomach placed in the retrosternal space and the other three experienced delayed gastric emptying that required revision of the piloroplasty. There were two deaths (5.7%) and no graft failure. Strictures were observed in five patients (14.2%) and all of these were resolved with endoscopic dilatations. Six patients had diarrhea that spontaneously resolved. In the late follow-up period, all patients were on full feed and thriving well. The comparisons with gastric tube patients demonstrated that the total gastric transposition group presented with significantly less leaks and strictures (P = 0.0001 and 0.001, respectively). The incidence of death and graft failure was not statistically different. In conclusion, gastric transposition is as a simple technical procedure for esophageal replacement in children with satisfactory results, and is superior to gastric tube esophagoplasty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives To compare the biomechanical characteristics of 2 arthrodesis techniques for the equine proximal interphalangeal joint (PIP) using either a 3-hole 4.5 mm locking compression plate (LCP) or 3-hole 4.5 mm narrow dynamic compression plate (DCP), both with 2 transarticular 5.5 mm cortex screws. Study Design Experimental. Sample Population Cadaveric adult equine forelimbs (*n=6 pairs). Methods For each forelimb pair, 1 limb was randomly assigned to 1 of 2 treatment groups and the contralateral limb by default to the other treatment group. Construct stiffness, gap formation across the PIP joint, and rotation about the PIP joint were determined for each construct before cyclic axial loading and after each of four, 5000 cycle loading regimens. After the 20,000 cycle axial loading regimen, each construct was loaded to failure. Results There were no significant differences in construct stiffness, gap formation, or sagittal plane rotation between the LCP and DCP treatment groups at any of the measured time points. Conclusion Biomechanically, fixation of the equine PIP joint with a 3-hole 4.5 mm LCP is equivalent to fixation with a 3-hole 4.5 mm narrow DCP under the test conditions used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gap junction channels, formed by connexins (Cx), are involved in the maintenance of tissue homeostasis, cell growth, differentiation, and development. Several studies have shown that Cx43 is involved in the control of wound healing in dermal tissue. However, it remains unknown whether Cx43 plays a role in the control of liver fibrogenesis. Our study investigated the roles of Cx43 heterologous deletion on carbon tetrachloride (CCl(4))-induced hepatic fibrosis in mice. We administered CCl(4) to both Cx43-deficient (Cx43(+/-)) and wild-type mice and examined hepatocellular injury and collagen deposition by histological and ultrastructural analyses. Serum biochemical analysis was performed to quantify liver injury. Hepatocyte proliferation was analyzed immunohistochemically. Protein and messenger RNA (mRNA) expression of liver connexins were evaluated using immunohistochemistry as well as immunoblotting analysis and quantitative real-time PCR. We demonstrated that Cx43(+/-) mice developed excessive liver fibrosis compared with wild-type mice after CCl(4)-induced chronic hepatic injury, with thick and irregular collagen fibers. Histopathological evaluation showed that Cx43(+/-) mice present less necroinflammatory lesions in liver parenchyma and consequent reduction of serum aminotransferase activity. Hepatocyte cell proliferation was reduced in Cx43(+/-) mice. There was no difference in Cx32 and Cx26 protein or mRNA expression in fibrotic mice. Protein expression of Cx43 increased in CCl(4)-treated mice, although with aberrant protein location on cytoplasm of perisinusoidal cells. Our results demonstrate that Cx43 plays an important role in the control and regulation of hepatic fibrogenesis. Microsc. Res. Tech. 74:421-429, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the effects of three different dental adhesive systems on the formation of secondary root caries, in vitro, with a standardized interfacial gap in a filled cavity model. Methods: 40 sound human molars were selected and randomly assigned to four experimental groups: Clearfil SE Bond (CSEB), Xeno III (X-III), Scotchbond Multi-Purpose Plus (SBMP) and negative control (NC) without an adhesive system. After the standardized Class V cavity preparations on the buccal and lingual surfaces, restorations were placed with resin composite (Filtek Z250) using a standardized interfacial gap, using a 3 x 2 mm piece of 50 mu m metal matrix. The teeth were sterilized with gamma irradiation and exposed to a cariogenic challenge using a bacterial system with Streptococcus mutans. Depth and extension of wall lesions formed and the depth of outer lesions were measured by software coupled with light microscopy. Results: For wall lesion extension the ANOVA test showed differences between groups except between X-HI and SBMP (P= 0.294). The Tukey`s test of confidence intervals indicated smaller values for the CSEB group than for the others. For wall lesion depth the CSEB group also presented the smallest mean values of wall lesion depth when compared to the others (P< 0.0001) for all comparisons using Tukey`s test. Regarding outer lesion depth, all adhesives showed statistically similar behavior. SEM evaluation of the morphologic appearance of caries lesions confirmed the statistical results showing small caries lesion development for cavities restored with CSEB adhesive system, which may suggest that this adhesive system interdiffusion zone promoted a good interaction with subjacent dentin protecting the dental tissues from recurrent caries. (Am J Dent 2010;23:93-97).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined the early and long-term microtensile bond strengths (mu TBS) and interfacial enamel gap formation (IGW) of two-step selfetch systems to unground and ground enamel. Resin composite (Filtek Z250) buildups were bonded to proximal enamel surfaces (unground, bur-cut or SiC-treated enamel) of third molars after the application of four self-etch adhesives: a mild (Clearfil SE Bond [SE]), two moderate (Optibond Solo Plus Self-Etch Primer [SO] and AdheSE [AD]) and a strong adhesive (Tyrian Self Priming Etchant + One Step Plus [TY]) and two etch-and-rinse adhesive systems (Single Bond [SB] and Scotchbond Multi-Purpose Plus [SBMP]). Ten tooth halves were assigned for each adhesive. After storage in water (24 hours/37 degrees C), the bonded specimens were sectioned into beams (0.9 mm(2)) and subjected to mu TBS (0.5 mm/minute) or interfacial gap width measurement (stereomicroscope at 400x) either immediately (IM) or after 12 months (12M) of water storage. The data were analyzed by three-way repeated measures ANOVA and Tukey`s test (alpha=0.05). No gap formation was observed in any experimental condition. The mu TBS in the Si-C paper and diamond bur groups were similar and greater than the unground group only for the moderate self-etch systems (SO and AD). No reductions in bond strength values were observed after 12 months of water storage, regardless of the adhesive evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. Researchers have proposed the restoration of abfraction lesions, but limited information is available about the effects of occlusal loading on the margins of such restorations. Because abfraction is a well-recognized problem, the authors conducted a study to assess the effects of occlusal loading on the margins of cervical restorations. Methods. The authors prepared 40 wedge-shaped cavities in extracted premolars and restored them with a resin-based composite. They subjected specimens to occlusal loading (150 newtons, 101 cycles) on the buccal cusp, on the central fossa or on the lingual cusp, and they stored 1 the control group, specimens in deionized water. The authors used fluorescein to delimit marginal defects and evaluated the defects by using laser scanning confocal microscopy. Results. Results of chi(2) and Kruskal-Wallis tests (P < .05) showed that specimens subjected to occlusal loading had a higher percentage of marginal gaps (53.3 percent) than did the control specimens (10.0 percent). There were no differences between groups in marginal defect formation or in defect location, length or width. Conclusions. Occlusal loading led to a significant increase in gap formation at the margins of cervical resin-based composite restorations. Clinical Implications. The clinician cannot underestimate the effects of occlusal loading When restoring teeth with cervical wedge-shaped lesions. If occlusal loading is the main factor contributing to lesion formation, the clinician should identify and treat it before placing the restoration or otherwise run the risk that the restorative treatment will fail because of marginal gap formation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the dentin/resin adhesive interface of lateral walls of occlusal restorations after thermocycling. Materials and Methods: Occlusal cavities were prepared in 60 human molars, divided into six groups: no liner (1 and 4); glass-ionomer cement (GIC, Ketac Molar Easymix, 3M ESPE) (2 and 5); and resin-modified glass-ionomer cement (RMGIC, Vitrebond, 3M ESPE) (3 and 6). Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adper Single Bond 2, 3M ESPE) that was mixed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. Specimens of groups 4, 5 and 6 were thermocycled (5 degrees C-55 degrees C) with a dwell time of 30 seconds for 5000 cycles. After this period, teeth were sectioned in approximately 0.8-mm slices. One slice of each tooth was randomly selected for confocal microscopy analysis. The other slices were sectioned into 0.8 nun x 0.8 mm beams, which were submitted to microtensile testing (MPa). Data were analyzed using two-way ANOVA and Tukey test (p < 0.05). Results: There was no detectedstatistical difference on bond strength among groups (alpha < 0.05). Confocal microscopy analysis showed a higher mean gap size in group 4(12.5 mu m) and a higher percentage of marginal gaps in the thermocycled groups. The RNIGIC liner groups showed the lowest percentage of marginal gaps. Conclusions: Lining with RMGIC resulted in less gap formation at the dentin/resin adhesive interface after artificial aging. RMGIC or GIC liners did not alter the microtensile bond strength of adhesive system/resin composite to dentin on the lateral walls of Class I restorations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This prospective and controlled histologic study evaluates the impact of smoking on bone-to-implant contact, the bone density in the threaded area, and the bone density outside the threaded area around microimplants with anodized surface retrieved from human jaws. Methods: A total of 24 subjects (mean age 51.32 +/- 7.5 years) were divided in two groups: smokers (n = 13 subjects) and non-smokers (n = 11 subjects). Each subject received one microimplant with oxidized surface during conventional mandible or maxilla implant surgery. After 8 weeks, the microimplants and the surrounding tissue were removed and prepared for histomorphometric analysis. Results: Three microimplants placed in smokers showed no osseointegration. The newly formed bone showed early stages of maturation, mainly in the non-smokers. Marginal bone loss, gap, and fibrous tissue were present around implants retrieved from smokers. Histometric evaluation indicated that the mean bone-to-implant contact ranged between 25.97% +/- 9.02% and 40.01% +/- 12.98% for smokers and non-smokers, respectively (P <0.001). Smokers presented 28.17% +/- 10.32% of bone density in the threaded area, whereas non-smokers showed 46.34% +/- 19.12%. The mean of bone density outside the threaded area ranged between 18.76% and 25.11% for smokers and non-smokers, respectively (P>0.05). Conclusion: The present data obtained in human subjects confirm that smoking has a detrimental effect on early bone tissue response around oxidized implant surfaces. J Periodontol 2010;81:575-583.