993 resultados para Fabry-Perot Lasers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In specific conditions, photodynamic therapy (PDT) can enhance the distribution of macromolecules across the endothelial barrier in solid tumors. It was recently postulated that tumor neovessels were more responsive to PDT than the normal vasculature. We hypothesized that Visudyne(R)-mediated PDT could selectively increase liposomal doxorubicin (Liporubicin) uptake in sarcoma tumors to rodent lungs while sparing the normal surrounding tissue. MATERIALS AND METHODS: Sarcoma tumors were generated subpleurally in the left lower lung lobe of 66 Fischer rats. Ten days following sarcoma implantation, tumors underwent different pre-treatment schemes: no PDT (controls), low-dose PDT (0.0625 mg/kg Visudyne(R), 10 J/cm(2) and 35 mW/cm(2)) and high-dose PDT (0.125 mg/kg Visudyne(R), 10 J/cm(2) and 35 mW/cm(2)). Liporubicin was then administered and allowed to circulate for 1, 3, or 6 hours. At the end of each treatment scheme, we assessed the uptake of Liporubicin in tumor and lung tissues by high-performance liquid chromatography and fluorescence microscopy. RESULTS: In all PDT-treated groups, there was a significant enhancement of Liporubicin uptake in tumors compared to controls after 3 and 6 hours of drug circulation. In addition, Liporubicin distribution within the normal lung tissue was not affected by PDT. Thus, PDT pre-treatment significantly enhanced the ratio of tumor-to-lung drug uptake compared to controls. Finally, fluorescence microscopy revealed a well-detectable Liporubicin signaling throughout PDT-treated tumors but not in controls. CONCLUSIONS: PDT is a tumor-specific enhancer of Liporubicin distribution in sarcoma lung tumors which may find a translation in clinics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thin disk and fiber lasers are new solid-state laser technologies that offer a combinationof high beam quality and a wavelength that is easily absorbed by metal surfacesand are expected to challenge the CO2 and Nd:YAG lasers in cutting of metals ofthick sections (thickness greater than 2mm). This thesis studied the potential of the disk and fiber lasers for cutting applications and the benefits of their better beam quality. The literature review covered the principles of the disk laser, high power fiber laser, CO2 laser and Nd:YAG laser as well as the principle of laser cutting. The cutting experiments were made with thedisk, fiber and CO2 lasers using nitrogen as an assist gas. The test material was austenitic stainless steel of sheet thickness 1.3mm, 2.3mm, 4.3mm and 6.2mm for the disk and fiber laser cutting experiments and sheet thickness of 1.3mm, 1.85mm, 4.4mm and 6.4mm for the CO2 laser cutting experiments. The experiments focused on the maximum cutting speeds with appropriate cut quality. Kerf width, cutedge perpendicularity and surface roughness were the cut characteristics used to analyze the cut quality. Attempts were made to draw conclusions on the influence of high beam quality on the cutting speed and cut quality. The cutting speeds were enormous for the disk and fiber laser cutting experiments with the 1.3mm and 2.3mm sheet thickness and the cut quality was good. The disk and fiber laser cutting speeds were lower at 4.3mm and 6.2mm sheet thickness but there was still a considerable percentage increase in cutting speeds compared to the CO2 laser cutting speeds at similar sheet thickness. However, the cut quality for 6.2mm thickness was not very good for the disk and fiber laser cutting experiments but could probably be improved by proper selection of cutting parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: A study was made to determine the temperature increment at the dental root surface following Er,Cr:YSGG laser irradiation of the root canal. Design. Human canines and incisors previously instrumented to K file number ISO 30 were used. Irradiation was carried out with glass fiber endodontic tips measuring 200 μm in diameter and especially designed for insertion in the root canal. The teeth were irradiated at 1 and 2 W for 30 seconds, without water spraying or air, and applying a continuous circular movement (approximately 2 mm/sec.) in the apico-coronal direction. Results: At the 1 W power setting, the mean temperature increment was 3.84ºC versus 5.01ºC at 2 W. In all cases the difference in mean value obtained after irradiation versus the mean baseline temperature proved statistically significant (p< 0.05). Conclusions: Application of the Er,Cr:YSGG laser gives rise to a statistically significant temperature increment at the external root surface, though this increment is probably clinically irrelevant, since it would appear to damage the tissues (periodontal ligament and alveolar bone) in proximity to the treated tooth

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fiber laser for materials processing have undergone a rapid development in the pastseveral years. As fiber laser provides a combination of high beam quality and awavelength that is easily absorbed by metal surfaces, the named future laser isexpected to challenge the CO2 and Nd:YAG lasers in the area of metal cutting. This thesis studied the performance of fiber laser cutting mild steel. In the literature review part, it introduced the laser cutting principle and the principle of fiber laser including the newest development of fiber laser cuttingtechnology. Because the fiber laser cutting mild steel is a very young technology, a preliminary test was made in order to investigate effect of the cutting parameters on cut quality. Then the formal fiber laser cutting experiment was madeby using 3 mm thickness S355 steel with oxygen as assistant gas. The experimentwas focused on the cut quality with maximum cutting speed and minimum oxygen gas pressure. And the cut quality is mainly decided by the kerf width, perpendicularity tolerance, surface roughness and striation patterns. After analysis the cutting result, several conclusions were made. Although the best result got in the experiment is not perfect as predicted, the whole result of the test can be accepted. Compared with CO2 laser, a higher cutting speed was achieved by fiber laser with very low oxygen gas pressure. A further improvement about the cutting quality might be possible by proper selection of process parameters. And in order to investigate the cutting performance more clearly, a future study about cutting different thickness mild steel and different shape was recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A collaborative study on Raman spectroscopy and microspectrophotometry (MSP) was carried out by members of the ENFSI (European Network of Forensic Science Institutes) European Fibres Group (EFG) on different dyed cotton fabrics. The detection limits of the two methods were tested on two cotton sets with a dye concentration ranging from 0.5 to 0.005% (w/w). This survey shows that it is possible to detect the presence of dye in fibres with concentrations below that detectable by the traditional methods of light microscopy and microspectrophotometry (MSP). The MSP detection limit for the dyes used in this study was found to be a concentration of 0.5% (w/w). At this concentration, the fibres appear colourless with light microscopy. Raman spectroscopy clearly shows a higher potential to detect concentrations of dyes as low as 0.05% for the yellow dye RY145 and 0.005% for the blue dye RB221. This detection limit was found to depend both on the chemical composition of the dye itself and on the analytical conditions, particularly the laser wavelength. Furthermore, analysis of binary mixtures of dyes showed that while the minor dye was detected at 1.5% (w/w) (30% of the total dye concentration) using microspectrophotometry, it was detected at a level as low as 0.05% (w/w) (10% of the total dye concentration) using Raman spectroscopy. This work also highlights the importance of a flexible Raman instrument equipped with several lasers at different wavelengths for the analysis of dyed fibres. The operator and the set up of the analytical conditions are also of prime importance in order to obtain high quality spectra. Changing the laser wavelength is important to detect different dyes in a mixture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The pre-conditioning of tumor vessels by low-dose photodynamic therapy (L-PDT) was shown to enhance the distribution of chemotherapy in different tumor types. However, how light dose affects drug distribution and tumor response is unknown. Here we determined the effect of L-PDT fluence on vascular transport in human mesothelioma xenografts. The best L-PDT conditions regarding drug transport were then combined with Lipoplatin(®) to determine tumor response. in vivo. Lasers Surg. Med. 47:323-330, 2015. © 2015 Wiley Periodicals, Inc. METHODS: Nude mice bearing dorsal skinfold chambers were implanted with H-Meso1 cells. Tumors were treated by Visudyne(®) -mediated photodynamic therapy with 100 mW/cm(2) fluence rate and a variable fluence (5, 10, 30, and 50 J/cm(2) ). FITC-Dextran (FITC-D) distribution was assessed in real time in tumor and normal tissues. Tumor response was then determined with best L-PDT conditions combined to Lipoplatin(®) and compared to controls in luciferase expressing H-Meso1 tumors by size and whole body bioluminescence assessment (n = 7/group). RESULTS: Tumor uptake of FITC-D following L-PDT was significantly enhanced by 10-fold in the 10 J/cm(2) but not in the 5, 30, and 50 J/cm(2) groups compared to controls. Normal surrounding tissue uptake of FITC-D following L-PDT was significantly enhanced in the 30 J/cm(2) and 50 J/cm(2) groups compared to controls. Altogether, the FITC-D tumor to normal tissue ratio was significantly higher in the 10 J/cm(2) group compared others. Tumor growth was significantly delayed in animals treated by 10 J/cm2-L-PDT combined to Lipoplatin(®) compared to controls. CONCLUSIONS: Fluence of L-PDT is critical for the optimal distribution and effect of subsequently administered chemotherapy. These findings have an importance for the clinical translation of the vascular L-PDT concept in the clinics. Lasers Surg. Med. 47:323-330, 2015.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El láser de Nd:YAG está compuesto por un granate de itrio y aluminio, contaminado por neodimio. Emite a una longitud de onda de 1064 nm, en el infrarrojo cercano. A diferencia de otros láseres, el láser de Nd:YAG, puede transmitirse a través de fibra óptica, lo cual permite una fácil aplicación de este tipo de energía en espacios anatómicos bucodentarios de difícil acceso. Este hecho, asociado al potente efecto bactericida que produce esta longitud de onda, lo convierten en una herramienta ideal en los tratamientos endodóncicos y periodontales, en los que puede mejorar los resultados obtenidos con las técnicas convencionales. También se utiliza en ciertos tratamientos de Cirugía Bucal, principalmente para las exéresis de lesiones de tejidos blandos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lasertarkkuusporauksella on tämän hetken teollisuudessa useita sovelluksia, kuten esimerkiksi mustesuihkukirjoittimet, dieselmoottoreiden polttoainesuuttimet, lääketieteen instrumentit, turbiinien lapojen jäähdytysreiät ja stensiilit. Tässä työssä on tutkittu laserporauksen mahdollisuuksia 99,9 % kupariin sekä EN 1.4301 ruostumattomaan teräkseen (vastaava AISI 304). Ainepaksuuksia oli käytettävissä kolmea: 0,1 mm, 0,5 mm ja 1,0 mm. Vertailun vuoksi valittiin tutkimukseen mukaan ainepaksuudeltaan 1,0 mm EN 1.4432 haponkestävää terästä (vastaava AISI 316L). Tutkimuksessa käytettiin kolmea eritehoista 1,064 µm aallonpituuden Nd:YAG – laseria ja yhtä CO2 – laseria. Poratut reiät kuvattiin elektronimikroskoopilla ja jokaisesta reiästä mitattiin halkaisija, ympyrämäisyys ja kartiokkuus. Lisäksi reiän laatua arvioitaessa tarkasteltiin purseen määrää reikien ympärillä. Tutkimus osoitti, että eri materiaaleihin voidaan porata, laserin säteen laadusta ja aallonpituudesta riippuen, hyvin erikokoisia reikiä. Kartiokkuuteen havaittiin voitavan vaikuttaa polttopisteen paikkaa siirtämällä.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityö on tehty kuitumateriaalien laserleikkauksen tutkimusprojektissa ILAC/PAPER. Päätavoitteena on selvittää laserleikkauksen kustannukset ja arvioida kahden laserleikkaussovelluksen taloudellista kannattavuutta. Teoriaosassa tavoitteena on etsiä teknologiainvestoinneista piirteitä, jotka tulee ottaa huomioon hanketta suunnitellessa. Työssä esitellään myös menetelmä teknologiainvestointien arviointiin. Työssä on kolme aihepiiriä; teknologiainvestointien arviointi, laserleikkauksen perusteet ja kuitumateriaalien laserleikkauskustannuksia käsittelevä empiriaosa. Teoriaosan lähdemateriaalina on käytetty toimintolaskentaa ja teknologiainvestointeja käsiteleviä julkaisuja. Empiriaosa on koottu teollisuuden tiedonannoista, tutkimusmateriaalista ja myyntitarjouksista. Teknologiainvestointien perusteleminen on vaikeaa perinteisillä investointilaskennan menetelmillä vähäisistä suorista kustannussäästöistä johtuen. Sopiva menetelmä arvioikin hankkeet laajempina kokonaisuuksina. Laserlaitteistojen vuosittaiset kustannukset ovat suuret. Luotettavuus, huoltovapaus ja joustavuus ovat hyötyjä, jotka tekevät laserlaitteistosta kannattavan. Hankintahinta ja tuottavuus ratkaisevat investoinnin kannattavuuden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityössä tutkitaan diodilaserhitsausta mahdollisena teollisuuden menetelmänä ja menetelmän vaatimuksia hitsattaessa ohutlevyjä. Työssä tutkittavat materiaalit ovat kylmävalssattu teräs ja ruostumaton teräs sekä liitosmuotoina päittäis-, laippa- ja päällekkäisliitos. Materiaalivahvuudet ovat 0,50 mm:stä 1,50 mm:iin. Työn tavoitteena on määrittää näille kyseisille materiaaleille ja liitosmuodoille hitsausnopeus levynvahvuuden funktiona. Lisäksi käsitellään diodilaserin rakennetta, säteen muodostusta, säteen muokkaamista, säteen analysointia ja säteen turvallisuuteen liittyviä asioita. Suoritetaan vertailua käytössä oleviin muihin lasertyöstömenetelmiin konepajoissa ja tehdään arvio mahdollisen diodilaserinvestoinnin kannattavuudesta. Diodilaserhitsauskokeissa käytettiin Hämeen ammattikorkeakoulun Riihimäen yksikön 1 kW:n tehoista diodilaseria. Koekappaleet leikattiin suuntaisleikkurilla. Osalle hitsatuista kappaleista tehtiin poikittaiset vetokokeet ja mitattiin mikrokovuudet. Virheitä tutkittiin silmämääräisesti sekä radiografisella kuvauksella. Kaikille tutkituille liitoksille, materiaaleille ja vahvuuksille saatiin määriteltyä hitsausnopeudet. Tehtyjen testien perusteella suuntaisleikkurin käyttö on mahdollista. Lisäksi havaittiin suojakaasun käytön myötä, että kirkkaan sulan aiheuttama heijastavuuden kasvu edellyttää hitsausnopeuden pienentämistä.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By exciting at 788 nm, we have characterized the near infrared emissions of trivalent thulium ions in monoclinic KGd(WO4)2 single crystals at 1.48 and 1.84 mm as a function of dopant concentration from 0.1% to 10% and temperature from 10 K to room temperature. We used the reciprocity method to calculate the maximum emission cross-section of 3.0310220 cm2 at 1.838 mm for the polarization parallel to the Nm principal optical direction. These results agrees well with the experimental data. Experimental decay times of the 3H4!3F4 and 3F4!3H6 transitions have been measured as a function of thulium concentration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Els làsers aporten solucions a una gran varietat de problemes de la vida diària ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laser diffraction (LD) and static image analysis (SIA) of rectangular particles [United States Pharmacopeia, USP30-NF25, General Chapter <776>, Optical Miroscopy.] have been systematically studied. To rule out sample dispersion and particle orientation as the root cause of differences in size distribution profiles, we immobilize powder samples on a glass plate by means of a dry disperser. For a defined region of the glass plate, we measure the diffraction pattern as induced by the dispersed particles, and the 2D dimensions of the individual particles using LD and optical microscopy, respectively. We demonstrate a correlation between LD and SIA, with the scattering intensity of the individual particles as the dominant factor. In theory, the scattering intensity is related to the square of the projected area of both spherical and rectangular particles. In traditional LD the size distribution profile is dominated by the maximum projected area of the particles (A). The diffraction diameters of a rectangular particle with length L and breadth B as measured by the LD instrument approximately correspond to spheres of diameter ØL and ØB respectively. Differences in the scattering intensity between spherical and rectangular particles suggest that the contribution made to the overall LD volume probability distribution by each rectangular particle is proportional to A2/L and A2/B. Accordingly, for rectangular particles the scattering intensity weighted diffraction diameter (SIWDD) explains an overestimation of their shortest dimension and an underestimation of their longest dimension. This study analyzes various samples of particles whose length ranges from approximately 10 to 1000 μm. The correlation we demonstrate between LD and SIA can be used to improve validation of LD methods based on SIA data for a variety of pharmaceutical powders all with a different rectangular particle size and shape.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lasers in pediatric dermatology were developed as a result of the treatment of port-wine stains. Infantile hemangiomas may benefit, in some cases, from laser treatment as well as venous and lymphatic malformations. For certain pigmented lesions, as well as some hamartomas, laser treatments are a credible alternative to surgical resection. Bum scars are improved by lasers which stimulate collagen remodeling. Furthermore, hair removal of congenital and acquired hypertrichosis can relieve psychosocial discomfort and improve quality of life. The management of pain and fear of children undergoing laser treatment, using either topical or general anesthesia, remains of central importance.