869 resultados para Effect of surface active agents on rubber filter interaction
Resumo:
PurposeThe mechanical properties of acrylic resins used in intraoral prostheses may be altered by frequent exposure to liquids such as beverages and mouthwashes. This study aimed to evaluate the effect of thermocycling and liquid immersion on the hardness of four brands of acrylic resins commonly used in removable prostheses (Onda Cryl, QC-20, Classico, Lucitone).Materials and MethodsFor each brand of resin, seven specimens were immersed in each of six solutions (coffee, cola, red wine, Plax-Colgate, Listerine [LI], Oral B), and seven more were placed in artificial saliva (control). The hardness was tested using a microhardness tester before and after 5000 thermocycles and after 1, 3, 24, 48, and 96 hours of immersion. The results were analyzed using three-way repeated-measures ANOVA and Tukey's test (p < 0.05).ResultsThe hardness of the resins decreased following thermocycling and immersion in the solutions. Specimens immersed in cola and wine exhibited significant decreases in hardness after immersion for 96 hours, although the greatest significant decrease in hardness occurred in specimens immersed in LI. However, according to American Dental Association specification 12, the Knoop hardness of acrylic resins for intraoral prostheses should not be below 15. Thus, the median values of superficial hardness observed in most of the acrylic resins in this study are considered clinically acceptable.ConclusionsThe microhardness of polymers used for intraoral prostheses decreases following thermocycling. Among specimens immersed in beverages, those immersed in cola or wine experienced the greatest decrease in microhardness. Immersion of acrylic resins in LI significantly decreased the microhardness in relation to the initial value. Among the resins assessed, QC-20 exhibited the lowest initial hardness.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The Polymeric Precursor Method has proved suitable for synthesizing reactive powders using low temperatures of calcination, especially when compared with conventional methods. However, during the thermal decomposition of the polymeric precursor the combustion event can be releases an additional heat that raises the temperature of the sample in several tens of degrees Celsius above the set temperature of the oven. This event may be detrimental to some material types, such as the titanium dioxide semiconductor. This ceramic material has a phase transition at around 600 ° C, which involves the irreversible structural rearrangement, characterized by the phase transition from anatase to rutile TiO2 phase. The control of the calcination step then becomes very important because the efficiency of the photocatalyst is dependent on the amount of anatase phase in the material. Furthermore, use of dopant in the material aims to improve various properties, such as increasing the absorption of radiation and in the time of the excited state, shifting of the absorption edge to the visible region, and increasing of the thermal stability of anatase. In this work, samples of titanium dioxide were synthesized by the Polymeric Precursor Method in order to investigate the effect of Fe (III) doping on the calcination stages. Thermal analysis has demonstrated that the Fe (III) insertion at 1 mol% anticipates the organic decomposition, reducing the combustion event in the final calcination. Furthermore, FTIR-PAS, XRD and SEM results showed that organic matter amount was reduced in the Fe (III)-doped TiO2 sample, which reduced the rutile phase amount and increased the reactivity and crystallinity of the powder samples.
Resumo:
Objective: The purpose of this study was to evaluate the effects of the platelet-rich plasma (PRP) when used in combination with autogenous bone graft and bioabsorbable membrane (Resolut® ) in the treatment of Class III furcation defects in dogs. Material and method: Class III furcation defects (5 mm in height and in depth) were surgically created in the mandibular third premolars of five mongrel dogs. After nine weeks, the lesions were treated with scaling and root planning and each defect received one of the following treatments: autogenous bone graft + membrane (group C) or PRP + autogenous bone graft + membrane (group T). After a healing period of 90 days, the animals were sacrificed. Routine histological processing and staining with hematoxilyn and eosin and Masson trichrome were performed and a histomorphometric analysis determined the effect of the treatments on periodontal tissue regereneration. Data were analyzed by Hotelling’s T-squared (p < 0.05). Result: No statistically significant difference between C and T groups was observed by the histomorphometric analysis of the furcation area. Both treatment groups demonstrated similar regenerative results with the furcation defects partially filled and periodontal regeneration limited to the experimental notches of the lesions. (p > 0.05). Conclusion: According to the present results, PRP does not enhance the periodontal regeneration in class III furcation defects treated with autogenous bone graft and bioabsorbable membrane.
Resumo:
The purpose of this study was to evaluate the effects of the platelet-rich plasma (PRP) when used in combination with autogenous bone graft and bioabsorbable membrane (Resolut® ) in the treatment of Class III furcation defects in dogs. Material and method: Class III furcation defects (5 mm in height and in depth) were surgically created in the mandibular third premolars of five mongrel dogs. After nine weeks, the lesions were treated with scaling and root planning and each defect received one of the following treatments: autogenous bone graft + membrane (group C) or PRP + autogenous bone graft + membrane (group T). After a healing period of 90 days, the animals were sacrificed. Routine histological processing and staining with hematoxilyn and eosin and Masson trichrome were performed and a histomorphometric analysis determined the effect of the treatments on periodontal tissue regereneration. Data were analyzed by Hotelling’s T-squared (p < 0.05). Result: No statistically significant difference between C and T groups was observed by the histomorphometric analysis of the furcation area. Both treatment groups demonstrated similar regenerative results with the furcation defects partially filled and periodontal regeneration limited to the experimental notches of the lesions. (p > 0.05). Conclusion: According to the present results, PRP does not enhance the periodontal regeneration in class III furcation defects treated with autogenous bone graft and bioabsorbable membrane.
Resumo:
Objective In studies on Candida albicans adhesion to surfaces, diverse protocols have been used for collection and preparation of saliva samples. Thus, this study investigated whether variations in the centrifugation parameters and number of donors of saliva would influence the adhesion of C. albicans to a denture base resin. Methods Resin acrylic samples (n = 72) were made and then divided into four groups: (a) control – specimens were left without preconditioning in saliva; (b) three experimental groups, in which the specimens were preconditioned with saliva collected from 15 volunteers and centrifuged at 12 000 g for 5 min (G1); from 15 volunteers and centrifuged at 18 000 g for 30 min (G2); and from one volunteer and centrifuged at 12 000 g for 5 min (G3). Candida adhesion was evaluated by both the 2,3-bis(2-methoxy-4-nitro-5-sulfophenyl)-5-[(phenylamino) carbonyl]-2H-tetrazolium hydroxide (XTT) reduction method and crystal violet staining. Data were analyzed by one-way analyses of variance (P = 0.05). Results For XTT reduction assay, groups G2, G3, and control were not significantly different, whereas group G1 showed significantly higher absorbance value than control. For crystal violet staining there were no significant differences among all groups. Conclusion Variations in the centrifugation parameters and number of donors of saliva may influence C. albicans adhesion to denture base resins.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)