994 resultados para Dissertation of vestibular exam


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The capacity to use geologic materials (soil and rock) that are available in the surrounding environment is inherent to the human civilization and has contributed to the evolution of societies throughout the course of history. The use of these materials in the construction of structures such as houses, roads, railways or dams, stirred the improvement of socioeconomic and environmental conditions. Several reports of structural problems on embankments can be found throughout history. A considerable number of those registers can be linked to inadequate compaction, demonstrating the importance of guaranteeing a suitable quality of soil compaction. Various methodologies and specifications of compaction quality control on site of earthworks, based on the fill moisture content and dry unit weight, were developed during the 20th century. Two widely known methodologies are the conventional and nuclear techniques. The conventional methods are based on the use of the field sand cone test (or similar) and sampling of material for laboratory-based testing to evaluate the fill dry unit weight and water content. The nuclear techniques measure both parameters in the field using a nuclear density gauge. A topic under discussion in the geotechnical community, namely in Portugal, is the comparison between the accuracy of the nuclear gauge and sand cone test results for assessing the compaction and density ratio of earth fills, particularly for dams. The main purpose of this dissertation is to compare both of them. The data used were acquired during the compaction quality control operations at the Coutada/Tamujais dam trial embankment and core construction. This is a 25 m high earth dam located in Vila Velha de Rodão, Portugal. To analyse the spatial distribution of the compaction parameters (water content and compaction ratio), a 3D model was also developed. The main results achieved are discussed and finally some considerations are put forward on the suitability of both techniques to ensure fill compaction quality and on additional research to complement the conclusions obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract: New Delhi metallo-beta-lactamase-1 (NDM-1) is a bacterial enzyme that renders the bacteria resistant to a variety of beta-lactam antibiotics. A 20-year-old man was hospitalized several times for surgical treatment and complications caused by a right-sided vestibular schwannoma. Although the patient acquired several multidrug-resistant infections, this study focuses on the NDM-1-producing Acinetobacter spp. infection. As it was resistant to all antimicrobials tested, the medical team developed a 20-day regimen of 750mg/day metronidazole, 2,000,000IU/day polymyxin B, and 100mg/day tigecycline. The treatment was effective, and the patient recovered and was discharged from the hospital.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to assess the flexor-extensor group of muscles of the knee in young athletes diagnosed with a total rupture of the anterior cruciate ligament (ACL). Eighteen knees of 18 athletes (14 men and 4 women) with an average age of 21.6 years (range 16-32 years) were assessed with a Cybex 6000 model isokinetic apparatus. The average interval between occurrence of the injury and assessment was 10.2 months (range 2 - 48 months). There was an associated meniscal injury in eight of the knees. Athletes with any other kind of associated injury, limitation, or blockage of the movement of the joint, significant pain during the exam, or interval between injury and exam of less than two months were excluded from the study. The parameters studied were the peak torque-velocity and flexor-extensor relationships at the constant angular velocities of 60°/sec and 240°/sec. Previous warming-up was done by means of an ergometric bicycle and adaptation with 3 submaximal repetitions. The contra-lateral side, which presented no injury, was used as control. Peak torque (PT) at the constant velocity of 60°/sec was greater than that at 240°/sec for knees with and without injuries. However, there was no significant difference between the injured and uninjured sides at 60°/sec or at 240°/sec. The average value for the flexor-extensor relationship at 60°/sec on the injured was 60% (( 6), compared to 57% (( 10) on the contra-lateral side. At 240°/sec, the average value was 75% ((10) on the injured side, and 65% ((12) on the contra-lateral side. In conclusion, despite the complete rupture of the ACL of one knee, the average values for the flexor-extensor relationship were similar on the injured and uninjured sides at the velocity of 60°/sec. As the velocity increased, an increase in the values for the flexor-extensor relationship of the knee also occurred, indicating a tendency of the performance of the flexor muscle group to approach that of the extensor muscle group, and this tendency was more pronounced on the side of the injury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Materials engineering focuses on the assembly of materials´ properties to design new products with the best performance. By using sub-micrometer size materials in the production of composites, it is possible to obtain objects with properties that none of their compounds show individually. Once three-dimensional materials can be easily customized to obtain desired properties, much interest has been paid to nanostructured poly-mers in order to build biocompatible devices. Over the past years, the thermosensitive microgels have become more common in the framework of bio-materials with potential applicability in therapy and/or diagnostics. In addition, high aspect ratio biopolymers fibers have been produced using the cost-effective method called electrospinning. Taking advantage of both microgels and electrospun fibers, surfaces with enhanced functionalities can be obtained and, therefore employed in a wide range of applications. This dissertation reports on the confinement of stimuli-responsive microgels through the colloidal electro-spinning process. The process mainly depends on the composition, properties and patterning of the precur-sor materials within the polymer jet. Microgels as well as the electrospun non-woven mats were investigated to correlate the starting materials with the final morphology of the composite fibers. PNIPAAm and PNIPAAm/Chitosan thermosensitive microgels with different compositions were obtained via surfactant free emulsion polymerization (SFEP) and characterized in terms of chemical structure, morphology, thermal sta-bility, swelling properties and thermosensitivity. Finally, the colloidal electrospinning method was carried out from spinning solutions composed of the stable microgel dispersions (up to a concentration of about 35 wt. % microgels) and a polymer solution of PEO/water/ethanol mixture acting as fiber template solution. The confinement of microgels was confirmed by Scanning Electron Microscopy (SEM). The electrospinning process was statistically analysed providing the optimum set of parameters aimed to minimize the fiber diameter, which give rise to electrospun nanofibers of PNIPAAm microgels/PEO with a mean fiber diameter of 63 ± 25 nm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quasi two-dimensional electron gas (q2DEG) hosted in the interface of an epitaxially grown lanthanum aluminate (LaAlO3) thin film with a TiO2-termi-nated strontium titanate (SrTiO3) substrate (001) has been massively studied in the last few years. The confinement of mobile electrons to within a few nanome-ters from the interface, superconductive behavior at low temperatures and elec-tron mobility exceeding 1000 cm2/(V.s) make this system an interesting candi-date to explore the physics of spin injection and transport. However, due to the critical thickness for conduction of 4 unit cells (uc) of LaAlO3, a high tunneling resistance hampers electrical access to the q2DEG, preventing proper injection of spin polarized current. Recently, our group found that depositing a thin overlayer of Co on LaAlO3 reduces the critical thickness, enabling conduction with only 1 uc of LaAlO3. Two scenarios arise to explain this phenomenon: a pinning of the Fermi level in the metal, inducing charge transfer in the SrTiO3; the creation of oxygen vacancies at the interface between LaAlO3 and the metal, leading to an n-type doping of the SrTiO3. In this dissertation, we will report on magnetotransport of metal/LaAlO3/SrTiO3 (metal: Ti, Ta, Co, Py, Au, Pt, Pd) heterostructures with 2 uc of LaAlO3 studied at low temperatures (2 K) and high magnetic fields (9 T). We have analyzed the transport properties of the gas, namely, the carrier concen-tration, mobility and magnetotransport regime and we will discuss the results in the light of the two scenarios mentioned above.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays manufacturing companies are facing a more challenging environment due to the unpredictability of the markets in order to survive. Enterprises need to keep innovating and deliver products with new internal or external characteristics. There are strategies and solutions, to different organisational level from strategic to operational, when technology is growing faster in operational level, more specifically in manufacturing system. This means that companies have to deal with the changes of the emergent manufacturing systems while it can be expensive and not easy to be implement. An agile manufacturing system can help to cope with the markets changeability. Evolvable Production Systems (EPS) is an emergent paradigm which aims to bring new solutions to deal with changeability. The proposed paradigm is characterised by modularity and intends to introduce high flexibility and dynamism at shop floor level through the use of the evolution of new computational devices and technology. This new approach brings to enterprises the ability to plug and unplug new devices and allowing fast reformulation of the production line without reprogramming. There is no doubt about the advantages and benefits of this emerging technology but the feasibility and applicability is still under questioned. Most researches in this area are focused on technical side, explaining the advantages of those systems while there are no sufficient works discussing the implementation risks from different perspective, including business owner. The main objective of this work is to propose a methodology and model to identify, classify and measure potential risk associated with an implementation of this emergent paradigm. To quantify the proposed comprehensive risk model, an Intelligent Decision system is developed employing Fuzzy Inference System to deal with the knowledge of experts, as there are no historical data and sufficient research on this area. The result can be the vulnerability assessment of implementing EPS technology in manufacturing companies when the focus is more on SMEs. The present dissertation used the experts’ knowledge and experiences, who were involved in FP7 project IDEAS, which is one of the leading projects in this area.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work has its origin on the necessity of enabling a design certified company, or DOA (Design Organization Approval), to perform a modification; this modification is the installation of EO/IR (Electro-optical infrared) sensors on aircrafts. The subject of interest in this dissertation lies on the aerodynamic impact of the modification on the aircraft. The primary purpose of the present thesis is the creation of a methodology that regards the design stage of the modification. This methodology serves as guidance to the DOA design team that is assigned to the design of the modification. The methodology includes a recommendation to the certification of the modification; it contains a method intended to decide the location of the installation of the sensors on the aircraft; it also comprises of a design structure specifically adapted to the modification in study. Regarding the aerodynamic impact, it is studied the aerodynamic analysis’ tools, which allows one to relate the different stages of design to the most suited tools to each stage. A case study is performed with the purpose of not only validating the methodology which was created but also to giving a first approach to the preliminary design of the modification. As example, there are used the Lockheed Martin C-130 aircraft and the FLIR Star Safire III sensor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: We tested the role of frozen section examination of the cone specimen in the evaluation of the resection margin status and to rule out invasion in patients with high-grade cervical intraepithelial neoplasia. METHODS: Twenty-five patients with cervical intraepithelial neoplasia underwent conization followed by frozen section examination and planned hysterectomy. The results of the definitive paraffin exam were compared with frozen section examination. RESULTS: In the evaluation of the margins by frozen section examination, 16 patients (64%) had positive cone margins and 9 (36%) had negative margins. The definitive paraffin examination of margin status was concordant in all the cases. Intraoperative diagnosis of invasion was made in 5 cases, and 1 of these was microinvasive. Among the remaining 20 cases, we detected 2 additional microinvasive carcinomas after paraffin study, so the diagnosis of the frozen section examination was concordant with the paraffin sections in 23/25 cases (92%). Two cases of microinvasive carcinoma were diagnosed as cervical intraepithelial neoplasia by frozen section examination and had less than 2 mm stromal invasion. CONCLUSIONS: In high-grade cervical intraepithelial neoplasia, frozen section examination can provide immediate and precise evaluation of the cone margin status in high-grade cervical intraepithelial neoplasia. It can identify frank invasion and permit adequate treatment in a one-stage procedure. In early microinvasive disease, frozen section examination fails to detect the area of invasion but reliably detects clear resection margins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine the eradication rate of an ultra-short treatment schedule for Helicobacter pylori infection in a population with peptic ulcers, using omeprazole, secnidazole, and azithromycin in a once-daily dose for 3 days. METHODS: Thirty patients with peptic ulcer diagnosed by upper endoscopy and for Helicobacter pylori infection by rapid urease test and histologic examination received omeprazole 40 mg, secnidazole 1000 mg, and azithromycin 500 mg, administered once daily for 3 days. A follow-up exam was performed 12 weeks after the end of the treatment. Patients who were negative for Helicobacter pylori infection by rapid urease test and histologic examination were considered cured. RESULTS: Patients were predominantly female, and the mean age was 50 years. Duodenal peptic ulcer was found in 73% of the patients. Eradication was achieved in 9 of the 28 (32%) patients as determined from the follow-up endoscopic exam. The eradication rate by intention to treat was 30%. Side effects were present in 3% of the patients, and compliance to treatment was total. CONCLUSIONS: In spite of the low rate of side effects and good compliance, the eradication index was low. A possible drawback of this therapy is that it reduces the efficacy of macrolide and nitroimidazole compounds in subsequent treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Preservation of the anal sphincter in surgery for cancer of the distal rectum in an attempt to avoid colostomy has been a main concern of colorectal surgeons. Various proposed procedures contradict oncological principles, especially with respect to pelvic lymphadenectomy. Therefore, prior knowledge of pelvic lymph node involvement is an important factor in choosing the operative technique, i.e., radical or conservative resection. Introduction of ultrasound, computerized tomography, and magnetic resonance have made preoperative study of the area possible. Nevertheless, these resources offer information of an anatomical nature only. Lymphoscintigraphy enables the morphological and functional evaluation of the pelvic area and contributes toward complementing the data obtained with the other imaging techniques. The objective of this prospective study is twofold: to standardize the lymphoscintigraphy technique and to use it to differentiate patients with rectal cancer from those with other coloproctologic diseases. CASUISTIC AND METHODS: Sixty patients with various coloproctologic diseases were studied prospectively. Ages ranged from 21 to 96 years (average, 51 and median, 55 years). Twenty-six patients were male and 34 were female. Thirty patients had carcinoma of the distal rectum as diagnosed by proctologic and anatomic-pathologic examinations, 20 patients had hemorrhoids, 5 had chagasic megacolon, 2 had diverticular disease, 2 had neoplasm of the right colon, and 1 had ulcerative colitis as diagnosed by proctologic exam and/or enema. The lymphoscintigraphy method consisted of injecting 0.25 mL of a dextran solution marked with radioactive technetium-99m into the right and left sides of the perianal region and obtaining images with a gamma camera. The results were analyzed statistically with a confidence level of 95% (P < .05) using the following statistical techniques: arithmetic and medium average, Fisher exact test, chi-square test corrected for continuity according to Yates, and distribution tables for the number of patients. RESULTS: In rectal cancer, the tracer progresses unilaterally or is absent; in other patients, the progress of the tracer is bilateral and symmetrical, although its progress may be slow. Statistical tests showed with high significance that the agreement index between the clinical diagnosis and the result of the lymphoscintigraphic exam was 93%. CONCLUSIONS: Lymphoscintigraphy is a standardized, painless, and harmless test that can be performed in all cases; it differentiates patients with rectal cancer from those with other coloproctological diseases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The cerebellum floccular complex lobes (FCLs) are housed in the FCL fossa of the periotic complex. There is experimental evidence indicating that the FCLs integrate visual and vestibular information, responsible for the vestibulo-ocular reflex, vestibulo-collic reflex, smooth pursuit and gaze holding. Thus, the behavior of extinct animals has been correlated with FCLs dimension in multiple paleoneuroanatomy studies. Here I analyzed braincase endocasts of a representative sample of Mammalia (48 species) and Aves (59 species) rendered using tomography and image segmentation and tested statistical correlations between the floccular complex volume, ecological and behavioral traits to assess various previously formulated paleobiological speculations. My results demonstrate: 1) there is no significant correlation between relative FCL volume and body mass; 2) there is no significant correlation between relative FCL and optic lobes size in birds; 3) average relative FCL size is larger in diurnal than in nocturnal birds but there is no statistically significant difference in mammals; 4) feeding strategies are related with different FCL size patterns in birds, but not in mammals; 5) locomotion type is not related with relative FCL size in mammals; 6) agility is not significantly correlated with FCL size in mammals. I conclude that, despite the apparent relation between FCL size and ecology in birds, the cerebellum of tetrapods is a highly plastic structure and may be adapted to control different functions across different taxonomic levels. For example, the european mole (Talpa europaea) which is fossorial and practically blind, has a FCL fossae relative size larger than those of bats, which are highly maneuverable. Therefore, variation in FCL size may be better explained by a combination of multiple factors with relation to anatomical and phylogenetic evolutionary constraints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Infertility is one of the less common presenting features associated with testicular tumors. We evaluated the histologic and biochemical findings, and pregnancy outcome in patients presenting with infertility who were found to have testicular tumors. METHODS: Seven patients with infertility were found to have testicular cancer over a 15-year period. All patients had a testicular ultrasound evaluation. The indications for the ultrasound were testicular pain in 2 patients, suspicious palpable mass in 4, and to rule out the presence of germ cell neoplasia in a patient with carcinoma in situ detected on a previous biopsy. Physical exam, histological findings, hormonal levels, tumor markers, and pregnancy outcome results were recorded from the patients medical charts. RESULTS: Two men had elevated serum follicle stimulant hormone and luteinizing hormone levels, 1 of them had an abnormally low serum testosterone level. Tumor markers were normal in all patients. In 4 patients the tumor was on the right side and in 3 on the left. The histological diagnoses were seminoma (n = 5), Leydig cell tumor (n = 1), and carcinoma in situ (n = 1). Of the 7 patients, 5 underwent adjuvant radiation therapy. Two patients had sperm cryopreserved. Follow up on fertility status was available in 6 cases. One patient has established a pregnancy and 5 did not achieve a pregnancy after treatment for their cancer. CONCLUSIONS: Most of the men who have testicular cancer and male infertility have a seminona. Therefore, men who present with infertility should be thoroughly investigated to rule out such serious, concomitant diseases along with their infertility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The unique proprieties exhibited by nanoscale particles compared to their macro size counterparts allow for the creation of novel neural activity manipula-tion procedures. In this sense, gold nanoparticles (AuNPs) can be used to stimu-late the electrical activity of neuron by converting light into heat. During this dissertation, AuNPs are synthesized by the citrate reduction method, resulting in a hydrodynamic diameter of approximately 16 nm and an absorbance peak of 530 nm. A system to control a 532 nm laser and measure the temperature variation was custom built from scratch specifically for this project. Temperature is then measured with recourse to a thermocouple and through changes in impedance. The built system had in consideration the necessities pre-sented by in vivo tests. Trials were performed by measuring the temperature rise of colloidal AuNP solutions, having the temperature variation reached a maximum of ap-proximately 18 ºC relative to control trials; successfully showing that light is ef-fectively transduced into heat when AuNPs are present. This novel approach enables an alternative to optogenetics, which require the animal to be genetically modified in order to allow neuron stimulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to differentiate benign ovarian tumors from malignant ones before surgery using color and pulsed Doppler sonography, and to compare results obtained before and after use of contrast medium, thereby verifying whether contrast results in an improvement in the diagnostic sensitivity. METHODS: Sixty two women (mean age 49.9 years) with ovarian tumors were studied, 45 with benign and 17 with malignant tumors. All women underwent a transvaginal color Doppler ultrasonographic exam. A study of the arterial vascular flow was made in all tumor areas, as well as an impedance evaluation of arterial vascular flow using the resistance index. RESULT: Localization of the vessels in the tumor revealed a greater proportion of malignant tumors with detectable internal vascular flows (64%) than benign tumors with such flows (22%). There was a considerable overlap of these findings. The use of contrast identified a greater number of vessels with confirmation in the totality of tumors, but did not improve the Doppler capacity in tumoral differentiation. Malignant tumors presented lower values of resistance index than the benign ones, whether or not contrast was used. The cutoff value for resistance index that better maximized the Doppler sensitivity and specificity was 0.55. Through this value, an increase of the sensitivity after contrast use was obtained, varying from 47% to 82%, while specificity remained statistically unchanged. CONCLUSION: Although the injection of a microbubble agent improved the sensitivity of the method detecting vascularization of tumors, a positive finding for vascularization by this method was not clinically useful in the differentiation of benign and malignant ovarian tumors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conventional molecular techniques for detection and characterization of relevant nucleic acid (i.e. DNA) sequences are, nowadays, cumbersome, expensive and with reduced portability. The main objective of this dissertation consisted in the optimization and validation of a fast and low-cost colorimetric nanodiagnostic methodology for the detection of single nucleotide polymorphisms (SNPs). This was done considering SNPs associated to obesity of commercial interest for STAB VIDA, and subsequent evaluation of other clinically relevant targets. Also, integration of this methodology into a microfluidic platform envisaging portability and application on points-of-care (POC) was achieved. To warrant success in pursuing these objectives, the experimental work was divided in four sections: i) genetic association of SNPs to obesity in the Portuguese population; ii) optimization and validation of the non-cross-linking approach for complete genotype characterization of these SNPs; iii) incorporation into a microfluidic platform; and iv) translation to other relevant commercial targets. FTO dbSNP rs#:9939609 carriers had higher body mass index (BMI), total body fat mass, waist perimeter and 2.5 times higher risk to obesity. AuNPs functionalized with thiolated oligonucleotides (Au-nanoprobes) were used via the non-cross-linking to validate a diagnostics approach against the gold standard technique - Sanger Sequencing - with high levels of sensitivity (87.50%) and specificity (91.67%). A proof-of-concept POC microfluidic device was assembled towards incorporation of the molecular detection strategy. In conclusion a successful framework was developed and validated for the detection of SNPs with commercial interest for STAB VIDA, towards future translation into a POC device.