959 resultados para Diagnostic Test Accuracy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Non-invasive vascular studies can provide crucial information on the presence, location, and severity of critical limb ischaemia (CLI), as well as the initial assessment or treatment planning. Ankle-brachial index with Doppler ultrasound, despite limitations in diabetic and end-stage renal failure patients, is the first-line evaluation of CLI. In this group of patients, toe-brachial index measurement may better establish the diagnosis. Other non-invasive measurements, such as segmental limb pressure, continuous-wave Doppler analysis and pulse volume recording, are of limited accuracy. Transcutaneous oxygen pressure (TcPO(2)) measurement may be of value when rest pain and ulcerations of the foot are present. Duplex ultrasound is the most important non-invasive tool in CLI patients combining haemodynamic evaluation with imaging modality. Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) are the next imaging studies in the algorithm for CLI. Both CTA and MRA have been proven effective in aiding the decision-making of clinicians and accurate planning of intervention. The data acquired with CTA and MRA can be manipulated in a multiplanar and 3D fashion and can offer exquisite detail. CTA results are generally equivalent to MRA, and both compare favourably with contrast angiography. The individual use of different imaging modalities depends on local availability, experience, and costs. Contrast angiography represents the gold standard, provides detailed information about arterial anatomy, and is recommended when revascularisation is needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives  To determine the diagnostic accuracy of World Health Organization (WHO) 2010 and 2006 as well as United States Department of Health and Human Services (DHHS) 2008 definitions of immunological failure for identifying virological failure (VF) in children on antiretroviral therapy (ART). Methods  Analysis of data from children (<16 years at ART initiation) at South African ART sites at which CD4 count/per cent and HIV-RNA monitoring are performed 6-monthly. Incomplete virological suppression (IVS) was defined as failure to achieve ≥1 HIV-RNA ≤400 copies/ml between 6 and 15 months on ART and viral rebound (VR) as confirmed HIV-RNA ≥5000 copies/ml in a child on ART for ≥18 months who had achieved suppression during the first year on treatment. Results  Among 3115 children [median (interquartile range) age 48 (20-84) months at ART initiation] on treatment for ≥1 year, sensitivity of immunological criteria for IVS was 10%, 6% and 26% for WHO 2006, WHO 2010 and DHHS 2008 criteria, respectively. The corresponding positive predictive values (PPV) were 31%, 20% and 20%. Diagnostic accuracy for VR was determined in 2513 children with ≥18 months of follow-up and virological suppression during the first year on ART with sensitivity of 5% (WHO 2006/2010) and 27% (DHHS 2008). PPV results were 42% (WHO 2010), 43% (WHO 2006) and 20% (DHHS 2008). Conclusion  Current immunological criteria are unable to correctly identify children failing ART virologically. Improved access to viral load testing is needed to reliably identify VF in children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective:The most difficult thyroid tumors to be diagnosed by cytology and histology are conventional follicular carcinomas (cFTCs) and oncocytic follicular carcinomas (oFTCs). Several microRNAs (miRNAs) have been previously found to be consistently deregulated in papillary thyroid carcinomas; however, very limited information is available for cFTC and oFTC. The aim of this study was to explore miRNA deregulation and find candidate miRNA markers for follicular carcinomas that can be used diagnostically.Design:Thirty-eight follicular thyroid carcinomas (21 cFTCs, 17 oFTCs) and 10 normal thyroid tissue samples were studied for expression of 381 miRNAs using human microarray assays. Expression of deregulated miRNAs was confirmed by individual RT-PCR assays in all samples. In addition, 11 follicular adenomas, two hyperplastic nodules (HNs), and 19 fine-needle aspiration samples were studied for expression of novel miRNA markers detected in this study.Results:The unsupervised hierarchical clustering analysis demonstrated individual clusters for cFTC and oFTC, indicating the difference in miRNA expression between these tumor types. Both cFTCs and oFTCs showed an up-regulation of miR-182/-183/-221/-222/-125a-3p and a down-regulation of miR-542-5p/-574-3p/-455/-199a. Novel miRNA (miR-885-5p) was found to be strongly up-regulated (>40-fold) in oFTCs but not in cFTCs, follicular adenomas, and HNs. The classification and regression tree algorithm applied to fine-needle aspiration samples demonstrated that three dysregulated miRNAs (miR-885-5p/-221/-574-3p) allowed distinguishing follicular thyroid carcinomas from benign HNs with high accuracy.Conclusions:In this study we demonstrate that different histopathological types of follicular thyroid carcinomas have distinct miRNA expression profiles. MiR-885-5p is highly up-regulated in oncocytic follicular carcinomas and may serve as a diagnostic marker for these tumors. A small set of deregulated miRNAs allows for an accurate discrimination between follicular carcinomas and hyperplastic nodules and can be used diagnostically in fine-needle aspiration biopsies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tuberculosis (TB) in South American camelids (SAC) is caused by Mycobacterium bovis or Mycobacterium microti. Two serological methods, rapid testing (RT) and the dual-path platform (DPP) assay, were evaluated using naturally infected SAC. The study population included 156 alpacas and 175 llamas in Great Britain, Switzerland, and the United States. TB due to M. bovis (n = 44) or M. microti (n = 8) in 35 alpacas and 17 llamas was diagnosed by gross pathology examination and culture. Control animals were from herds with no TB history. The RT and the DPP assay showed sensitivities of 71% and 74%, respectively, for alpacas, while the sensitivity for llamas was 77% for both assays. The specificity of the DPP assay (98%) was higher than that of RT (94%) for llamas; the specificities of the two assays were identical (98%) for alpacas. When the two antibody tests were combined, the parallel-testing interpretation (applied when either assay produced a positive result) enhanced the sensitivities of antibody detection to 89% for alpacas and 88% for llamas but at the cost of lower specificities (97% and 93%, respectively), whereas the serial-testing interpretation (applied when both assays produced a positive result) maximized the specificity to 100% for both SAC species, although the sensitivities were 57% for alpacas and 65% for llamas. Over 95% of the animals with evidence of TB failed to produce skin test reactions, thus confirming concerns about the validity of this method for testing SAC. The findings suggest that serological assays may offer a more accurate and practical alternative for antemortem detection of camelid TB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess the effect of tumor size and tumor-to-liver contrast of simulated hypovascular liver tumors on the diagnostic accuracy of hepatic computed tomography (CT).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Insect bite hypersensitivity (IBH) is an IgE-mediated allergic dermatitis caused by bites of Culicoides and Simulium species, and improved means of diagnosis are required. OBJECTIVES: The cellular antigen simulation test (CAST) with C. nubeculosus and S. vittatum extracts was assessed in a population of IBH-affected and healthy horses. Variations in test results over a one year period and possible cross-reactivity between different insect extracts was studied. METHODS: A total of 314 mature horses were studied using the CAST. Influence of severity of clinical signs, gender and age were evaluated, and 32 horses were tested repeatedly over one year. The kappa reliability test was used to assess agreement of the test results with different insect extracts. RESULTS: Horses with IBH had significantly higher sLT release than controls with C. nubeculosus and S. vittatum. The highest diagnostic sensitivity and specificity levels were attained when using adult C. nubeculosus extracts with the CAST (78% and 97%, respectively), suggesting that most horses with IBH are sensitised against Culicoides allergens. A proportion of IBH-affected horses was found to be sensitised to allergens of Simulium spp. in addition to those of C. nubeculosus. The CAST with C. nubeculosus had positive and negative predictive values > or = 80% for a true prevalence of IBH of 12-52%. In the follow-up study, the proportion of IBH-affected horses with a positive test result ranged from 90% in November to 68% in March. Severity of clinical signs or age did not influence test results significantly. However, IBH-affected males achieved significantly more positive test results than IBH-affected females. CONCLUSIONS: The CAST with adult C. nubeculosus has high specificity and good sensitivity for diagnosis of IBH. Horses with IBH are mainly sensitised to Culicoides allergens, and some horses are additionally also sensitised to allergens in Simulium spp. POTENTIAL RELEVANCE: The CAST is likely to be a useful test for diagnosis of IBH, even allowing the identification of IBH-affected but asymptomatic horses. This test may also help in further characterisation of allergens involved in this condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: To compare morphometric parameters and diagnostic performance of the new Stratus Optical Coherence Tomograph (OCT) Disc mode and the Heidelberg Retina Tomograph (HRT); to evaluate OCT's accuracy in determining optic nerve head (ONH) borders. METHODS: Controls and patients with ocular hypertension, glaucoma-like discs, and glaucoma were imaged with OCT Disc mode, HRT II, and colour disc photography (DISC-PHOT). In a separate session, automatically depicted ONH shape and size in OCT were compared with DISC-PHOT, and disc borders adjusted manually where required. In a masked fashion, all print-outs and photographs were studied and discs classified as normal, borderline, and abnormal. The Cohen kappa method was then applied to test for agreement of classification. Bland-Altman analysis was used for comparison of disc measures. RESULTS: In all, 49 eyes were evaluated. Automated disc margin recognition failed in 53%. Misplaced margin points were more frequently found in myopic eyes, but only 31/187 were located in an area of peripapillary atrophy. Agreement of OCT with photography-based diagnosis was excellent in normally looking ONHs, but moderate in discs with large cups, where HRT performed better. OCT values were consistently larger than HRT values for disc and cup area. Compared with HRT, small rim areas and volumes tended to be minimized by OCT, and larger ones to be magnified. CONCLUSIONS: Stratus OCT Disc protocol performed overall well in differentiating between normal and glaucomatous ONHs. However, failure of disc border recognition was frequently observed, making manual correction necessary. ONH measures cannot be directly compared between HRT and OCT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A nested PCR that successfully detected Neospora caninum DNA in serum of cattle was used for investigation of selected abortion cases and in a study of healthy pregnant cows at an abattoir. N. caninum DNA was not detected in serum from antibody positive dams that aborted due to N. caninum, but was present in serum of some antibody negative dams that aborted due to other causes. N. caninum DNA was also found in the serum of about half of the animals that aborted of undetermined cause, but was not detected in cow sera from two beef cattle herds in Western Australia with no recent history of abortion. In the abattoir study of 79 dams and their foetuses N. caninum DNA was found in serum of 3 dams and in material from 11 foetuses. The majority of the cows and all foetuses were antibody negative. Our findings suggest that there is no obvious relationship between the presence or absence of N. caninum DNA in serum and the presence of antibodies to N. caninum in dams, the presence of N. caninum DNA in foetuses or abortion due to N. caninum. This is the first report of the detection of N. caninum DNA in serum of cattle rather than the white blood cell fraction. It indicates the presence of free tachyzoites and/or parasite DNA in circulation. The results suggest that persistent infection in the absence of antibodies is a possible outcome of N. caninum infection. Infection of foetuses in the absence of antibodies supports the possibility of persistent infection due to immunotolerance to an early in utero infection. It is therefore important to test for N. caninum DNA as well as antibodies for the detection of exposed and/or infected animals. However, the presence or absence of N. caninum antibodies or DNA did not support nor exclude N. caninum as the cause of abortion. Additional criteria are required for a positive diagnosis of abortion caused by N. caninum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The positive and negative predictive value are standard measures used to quantify the predictive accuracy of binary biomarkers when the outcome being predicted is also binary. When the biomarkers are instead being used to predict a failure time outcome, there is no standard way of quantifying predictive accuracy. We propose a natural extension of the traditional predictive values to accommodate censored survival data. We discuss not only quantifying predictive accuracy using these extended predictive values, but also rigorously comparing the accuracy of two biomarkers in terms of their predictive values. Using a marginal regression framework, we describe how to estimate differences in predictive accuracy and how to test whether the observed difference is statistically significant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The rigorous test to which homeopathy was subject in our recent double-blind clinical trail of homeopathic treatment of attention deficit hyperactivity disorder (ADHD) necessitated optimized treatment meeting the highest standards. METHODS: Optimization was performed in three steps: (1) In successfully treated children, prescriptions leading to an insufficient response were analysed by a general questionnaire to identify unreliable symptoms. (2) Polarity analysis, a further development of Bönninghausen's concept of contraindications, was introduced in response to the frequently one-sided symptoms. This enabled us to use few but specific symptoms to identify the medicine whose genius symptoms exhibit the closest match to the patient's characteristic symptoms. (3) We investigated the influence of the primary perception symptoms on the result of the repertorization. Perception symptoms are not normally recorded during a patient interview even though they are among the most reliable facts related by the patients. At the same time we were able to improve the continuity of improvement of ADHD symptoms using liquid Q-potencies. RESULTS: Introducing the questionnaire, polarity analysis, and including perception symptoms, lead to an improvement in the success rate of the first prescription from 21% to 54%, of the fifth prescription from 68% to 84%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with suspected extracranial carotid or peripheral arterial disease received four SonoVue doses (0.3 ml, 0.6 ml, 1.2 ml and 2.4 ml) with Doppler ultrasound performed before and following each dose. Diagnostic quality of the CE-US examinations was evaluated off-site for duration of clinically useful contrast enhancement, artefact effects and percentage of examinations converted from non-diagnostic to diagnostic. Accuracy, sensitivity and specificity were assessed as agreement of CE-US diagnosis evaluated by an independent panel of experts with reference standard modality. The median duration of clinically useful signal enhancement significantly increased with increasing SonoVue doses (p< or =0.002). At the dose of 2.4 ml of SonoVue, diagnostic quality evaluated as number of inconclusive examinations significantly improved, falling from 40.7% at baseline down to 5.1%. Furthermore, SonoVue significantly (p<0.01) increased the accuracy, sensitivity and specificity of assessment of disease compared with baseline ultrasound. SonoVue increases the diagnostic quality of Doppler images and improves the accuracy of both spectral and colour Doppler examinations of extracranial carotid or peripheral arterial disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Preoperative chemoradiotherapy is generally recommended for locally advanced esophageal cancer (clinical stage T3 or T4 or nodal positive disease) but not for early cancer (clinical stage T0 to T2, N0). EUS has been described as the most accurate method to distinguish between early and locally advanced stage in several studies. Recently however, the high accuracy of EUS (90% or higher) was questioned by some investigators. This raises the issue whether the results of studies focused on EUS accuracy may be directly translated into daily clinical practice. Aim & Methods: The aim of this retrospective analysis was to assess the accuracy of preoperative EUS to distinguish between early and locally advanced esophageal cancer in daily clinical practice outside a study setting. EUS was performed by several investigators, including trainees in one university hospital. For this purpose, EUS reports and patient files (medical and surgical) including histological reports of 300 consecutive pts with esophageal tumors were reviewed. In pts with adenocarcinoma or squamous cell cancer and surgical resection without previous radio-/chemotherapy, EUS tumor staging was compared with histological diagnosis. Results: Out of the 300 consecutive pts with esophageal tumor and EUS 102 pts had esophageal surgery after EUS-staging without any radio-/chemotherapy. In 93 pts oesophageal cancer was confirmed, whereas 9 had other tumors. The mean age was 65 years (range 27-89), sex ratio female:male was 1:3.2. To distinguish between early and late tumor stage, the accuracy was 85%. The sensitivity and specificity for early cancer was 59%, and 93%, respectively. The diagnostic accuracy for local tumor spread was 90%, 90%, 68%, 69%, 89% for pT0, pT1, pT2, pT3 and pT4 lesions, respectively. The overall accuracy for T-stage was 74%. For pN-positive staging the accuracy of EUS was 73%. Conclusion: In daily clinical practice, the accuracy of EUS in assessing esophageal tumor staging is lower than in specific studies focusing on EUS accuracy. Mainly early esophageal cancer stages were overstaged. Thus, the implementation of recommendations for diagnostic work-up of esophageal cancer patients resulting from highly specific studies should consider the appropriate clinical setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine the accuracy of 1.5 Tesla (T) and 3 T magnetic resonance angiography (MRA) versus digital subtraction angiography (DSA) in the depiction of infrageniculate arteries in patients with symptomatic peripheral arterial disease. PATIENTS AND METHODS: A prospective 1.5 T, 3 T MRA, and DSA comparison was used to evaluate 360 vessel segments in 10 patients (15 limbs) with chronic symptomatic peripheral arterial disease. Selective DSA was performed within 30 days before both MRAs. The accuracy of 1.5 T and 3 T MRA was compared with DSA as the standard of reference by consensus agreement of 2 experienced readers. Signal-to-noise ratios (SNR) and signal-difference-to-noise ratios (SDNRs) were quantified. RESULTS: No significant difference in overall image quality, sufficiency for diagnosis, depiction of arterial anatomy, motion artifacts, and venous overlap was found comparing 1.5 T with 3 T MRA (P > 0.05 by Wilcoxon signed rank and as by Cohen k test). Overall sensitivity of 1.5 and 3 T MRA for detection of significant arterial stenosis was 79% and 82%, and specificity was 87% and 87% for both modalities, respectively. Interobserver agreement was excellent k > 0.8, P < 0.05) for 1.5 T as well as for 3 T MRA. SNR and SDNR were significantly increased using the 3 T system (average increase: 36.5%, P < 0.032 by t test, and 38.5%, P < 0.037 respectively). CONCLUSIONS: Despite marked improvement of SDNR, 3 T MRA does not yet provide a significantly higher accuracy in diagnostic imaging of atherosclerotic lesions below the knee joint as compared with 1.5 T MRA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most indices for the assessment of wear of various aetiologies include the distinction between 'enamel still present' and 'dentine exposed' for grading. Since the visual diagnosis of exposed dentine has not yet been validated, the present study is a first attempt to investigate its accuracy and consistency. Sixty-one examiners (23 scientists, 18 university dentists and 20 dental students) were asked to diagnose 49 tooth areas with different grades of wear and to decide whether dentine was exposed (positive test) or not (negative test). Afterwards, the teeth were histologically evaluated. In 44 areas, dentine (also in all cases with minor wear) was exposed, and in 5 areas enamel was present. Overall sensitivity was 0.65, specificity 0.88 and the proportion of correct diagnoses was 0.67. The diagnosis 'dentine is exposed' was about 5 times as likely and the diagnosis 'dentine is not exposed' half as likely to come from an area with exposed dentine than from an enamel-covered area. The closeness of the visual diagnosis to the histological findings was only fair (kappa=0.27), no significant impact of professional experience was found. For inter- and intra-examiner agreement, kappa was 0.28 and 0.55, respectively. It was concluded that the diagnosis of exposed dentine is difficult.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although the diagnosis of Gitelman syndrome (GS) and Bartter syndrome (BS) is now feasible by genetic analysis, implementation of genetic testing for these disorders is still hampered by several difficulties, including large gene dimensions, lack of hot-spot mutations, heavy workup time, and costs. This study evaluated in a cohort of patients with genetically proven GS or BS diagnostic sensibility and specificity of a diuretic test with oral hydrochlorothiazide (HCT test). Forty-one patients with GS (22 adults, aged 25 to 57; 19 children-adolescents, aged 7 to 17) and seven patients with BS (five type I, two type III) were studied; three patients with "pseudo-BS" from surreptitious diuretic intake (two patients) or vomiting (one patient) were also included. HCT test consisted of the administration of 50 mg of HCT orally (1 mg/kg in children-adolescents) and measurement of the maximal diuretic-induced increase over basal in the subsequent 3 h of chloride fractional clearance. All but three patients with GS but no patients with BS and pseudo-BS showed blunted (<2.3%) response to HCT; patients with BS and the two patients with pseudo-BS from diuretic intake had increased response to HCT. No overlap existed between patients with GS and both patients with BS and pseudo-BS. The response to HCT test is blunted in patients with GS but not in patients with BS or nongenetic hypokalemia. In patients with the highly selected phenotype of normotensive hypokalemic alkalosis, abnormal HCT test allows prediction with a very high sensitivity and specificity of the Gitelman genotype and may avoid genotyping.