999 resultados para Democracy quality
Resumo:
INTRODUCTION: We report the impact of canakinumab, a fully human anti-interleukin-1β monoclonal antibody, on inflammation and health-related quality of life (HRQoL) in patients with difficult-to-treat Gouty Arthritis. METHODS: In this eight-week, single-blind, double-dummy, dose-ranging study, patients with acute Gouty Arthritis flares who were unresponsive or intolerant to--or had contraindications for--non-steroidal anti-inflammatory drugs and/or colchicine were randomized to receive a single subcutaneous dose of canakinumab (10, 25, 50, 90, or 150 mg) (N = 143) or an intramuscular dose of triamcinolone acetonide 40 mg (N = 57). Patients assessed pain using a Likert scale, physicians assessed clinical signs of joint inflammation, and HRQoL was measured using the 36-item Short-Form Health Survey (SF-36) (acute version). RESULTS: At baseline, 98% of patients were suffering from moderate-to-extreme pain. The percentage of patients with no or mild pain was numerically greater in most canakinumab groups compared with triamcinolone acetonide from 24 to 72 hours post-dose; the difference was statistically significant for canakinumab 150 mg at these time points (P < 0.05). Treatment with canakinumab 150 mg was associated with statistically significant lower Likert scores for tenderness (odds ratio (OR), 3.2; 95% confidence interval (CI), 1.27 to 7.89; P = 0.014) and swelling (OR, 2.7; 95% CI, 1.09 to 6.50, P = 0.032) at 72 hours compared with triamcinolone acetonide. Median C-reactive protein and serum amyloid A levels were normalized by seven days post-dose in most canakinumab groups, but remained elevated in the triamcinolone acetonide group. Improvements in physical health were observed at seven days post-dose in all treatment groups; increases in scores were highest for canakinumab 150 mg. In this group, the mean SF-36 physical component summary score increased by 12.0 points from baseline to 48.3 at seven days post-dose. SF-36 scores for physical functioning and bodily pain for the canakinumab 150 mg group approached those for the US general population by seven days post-dose and reached norm values by eight weeks post-dose. CONCLUSIONS: Canakinumab 150 mg provided significantly greater and more rapid reduction in pain and signs and symptoms of inflammation compared with triamcinolone acetonide 40 mg. Improvements in HRQoL were seen in both treatment groups with a faster onset with canakinumab 150 mg compared with triamcinolone acetonide 40 mg. TRIAL REGISTRATION: clinicaltrials.gov: NCT00798369.
The quality of the diagnostic process of urinary tract infections: from the indication to the result
Resumo:
Background The PEmb-QoL is a validated 40-item questionnaire to quantify health-related quality of life in patients having experienced pulmonary embolism (PE). It covers six health dimensions: frequency of complaints, activities of daily living limitations, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we sought to prospectively validate the psychometric properties of a French version of the PEmb-QoL.MethodsWe performed a forward and backward translation of the English version of the PEmb-QoL into French. French-speaking consecutive adult patients with an acute, objectively confirmed PE admitted to the emergency department of a Swiss university hospital between 08/2009 and 09/2011 were recruited telephonically. We used standard psychometric tests and criteria to evaluate the acceptability, reliability, and validity of the French version of the PEmb-QoL. We also performed an exploratory factor analysis.ResultsOverall, 102 patients were enrolled in the study. The French version of the PEmb-QoL showed good reliability (internal consistency, item¿total and inter-item correlations), reproducibility (test-retest reliability), and validity (convergent, discriminant) in French-speaking patients with PE. The exploratory factor analysis suggested three underlying dimensions: limitations in daily activity (items 4b-m, 5a-d), symptoms (items 1a-h and 7), and emotional complaints (items 9a-f and j).ConclusionWe successfully validated the French version of the PEmb-QoL questionnaire in patients with PE. Our results show that the PEmb-QoL is a valuable tool for assessing health-related quality of life after PE in French-speaking patients.
Resumo:
This paper analyzes the implications of pre-trade transpareny on market performance. We find that transparency increases the precision held by agents, however we show that this increase in precision may not be due to prices themselves. In competitive markets, transparency increases market liquidity and reduces price volatility, whereas these results may not hold under imperfect competition. More importantly, market depth and volatility might be positively related with proper priors. Moreover, we study the incentives for liquidity traders to engage in sunshine trading. We obtain that the choice of sunshine/dark trading for a noise trader is independent of his order size, being the traders with higher liquidity needs more interested in sunshine trading, as long as this practice is desirable. Key words: Market Microstructure, Transparency, Prior Information, Market Quality, Sunshine Trading
Resumo:
In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.
Resumo:
A parliament with n members, distributed among two parties, decides whether to accept or reject a certain proposal. Each member of the parliament votes in favour or against. If there are at least t members in favour, the proposal is accepted; otherwise it is rejected. A non-member of the parliament, the briber, is interested in having the proposal accepted. To this end, he is willing to bribe members to induce them to vote in favour. It is compared a parliament with party discipline, where members vote according to the party line, and a parliament without party discipline, where members vote according to their own opinion. The paper determines, for given values of n and t , the average number of members that the briber has to bribe in each case (with the average taken with respect to all the possible allocations of members between parties and their votes, and also with respect to those allocations inducing the briber to bribe). The results show that a parliament with parties with party discipline is more costly for the briber to be bribed.
Resumo:
BACKGROUND: The superficial femoral vein (SFV) is a well-established alternative conduit for infra-inguinal reconstructivenous hypertension after SFV harvest may however result in significant morbidity. This study reports the efficiency of SFV as conduit for infra-inguinal reconstructions and characterize the anatomic and physiologic changes in harvest limbs and their relationship to the development of venous complications. METHODS: From May 1999 through November 2003, 23 SFV were harvested from 21 patients undergoing infra-inguinal reconstructions. Bypasses were controlled by regular duplex-ultrasound. The venous morbidity was assessed by measurements of leg circumferences, strain-gauge plethysmography and quality of life, investigated by the VEINES-QOL scale. RESULTS: At a mean follow-up of 10.4 months (range 1-56), primary, secondary patency and limb salvage rates of infra-inguinal bypasses using SFV are 71.4%, 76.2% and 85.7% respectively. No patient had major venous claudication. Oedema was significantly present in nine patients. Strain-gauge plethysmography showed outflow obstruction in all patients. The VEINES-QOL assessment showed no limitation in social and domestic activity, moderate complain about leg heaviness despite presence of oedema. CONCLUSION: The SFV harvest is a reliable conduit for infra-inguinal reconstructions and results in moderate venous morbidity in terms of functional consequences and quality of life.
Resumo:
Designation of Co-benefits and Its Implication for Policy: Water Quality versus Carbon Sequestration in Agricultural Soils, The