989 resultados para Cone, Spencer Houghton, 1785-1855.
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods Tubes containing solutions with different concentrations of K2HPO4 were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the K2HPO4 solutions were measured. The relationship between CT number and K2HPO4 concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results The relationship between K2HPO4 concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.
Resumo:
The hypertrophy of the mandibular coronoid process is a rare condition, progressive and of unknown etiology, characterized by the over development of the coronoid process determining their size increased, resulting in progressive and painful limitation of mouth opening. The mandibular hypomobility is a present symptom in several diseases and associates it to a specific cause requires detailed clinical and imaginologic examination. The cone-beam computed tomography has the potential to provide complementary informations above than conventional radiography. It also has the advantage of eliminate overlaps, provide high resolution image, helping not only in diagnosis, but also in planning the surgical procedure. Here we report a case of male patient, who appeared at the clinic for an evaluation of a trismus. He had no pain, only discomfort for progressive limitation of mouth opening. On physical examination, only a limited mouth opening has been found. Although the movements of laterality and protrusión were posible, they were very limited. Cone-beam computed tomography examination was performed, that showed an image compatible with bilateral hypertrophy of the mandibular coronoid process.
Resumo:
The aim of this study was to evaluate in vitro the apical leakage after the apical re-preparation and replacement of the principal gutta-percha point plus endodontic sealer (Sealer 26TM). Sixty extracted human canines were prepared by using a step back technique up to size 50 K type file apically. At each change of instrument the canals were irrigated with distilled water. After that step, the external surface roots were coated and subdivided into six groups with ten roots each: I – single gutta percha point technique; II – lateral condensation and III – hybrid technique. The IV, V and VI groups were similar to others groups but after to place the principal gutta percha point, it was removed, re-prepared up to size 60K file and in sequence replaced the principal gutta percha point and the root canal filling finished. The specimens were immersed in 2% Rhodamine BTM for 7 days at 37 oC. The apical leakage was measured by Image ToolsTM program. With Kruskal Wallis test statistical analysis showed that there was no significant difference between the techniques (p > 0.05).
Resumo:
The ability to tridimensionally evaluate pathological and anatomical areas, in apical surgery planning, presents a number of advantages. Cone beam computed tomography (CBCT) was developed for dental applications. This paper aims to present a literature review on CBCT, highlighting its advantages over both conventional computed tomography (CT) and radiography. Moreover, its clinical applications in apical surgery are discussed. LITERATURE REVIEW AND CONCLUSION: Unlikely CT, CBCT captures a volume of data in a single 360º rotation, providing benefits such as higher accuracy, better resolution, reduced scanning time and reduced radiation dose. In the maxillofacial region, CBCT has been mainly used in the assessment of dento-alveolar pathology and oral traumatology. CBCT provides a better diagnosis and quantitative information on periodontal bone levels than conventional radiography. It has also been used for patients requiring surgical facial reconstruction, orthognathic surgery, dental implants, and more complex tooth extractions. Besides that, it seems to be a significant tool in modern endodontic practice, presenting useful applications in apical surgery.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A class of light-cone integrals typical to one-loop calculations in the two-component formalism is considered. For the particular cases considered, convergence is verified though the results cannot be expressed as a finite sum of elementary functions. © 1988 American Institute of Physics.
Resumo:
The purpose of this study is to make a 3-dimensional (3-D) evaluation of the pharyngeal airway space (PAS) in patients with class I, II, and III malocclusion. Sixty patients were evaluated. The patients were divided in 3 groups according to their occlusion classification. The volume and area of PAS were evaluated using the software Dolphin 3-D Imaging in the preoperative period for orthognathic surgery. PAS volume and area were influenced by different patterns of malocclusion. The mean volume and area for class III patients were statistically bigger than for classes I and II patients (P < .001). There was also a significant difference for volume values between class I and II patients, being the bigger volume for the class I patients (P < .05). It was possible to conclude that the class III patients presented a bigger PAS compared with classes I and II patients.
Resumo:
This clinical study was conducted to correlate the levels of endotoxins and bacterial counts found in primary endodontic infection with the volume of periapical bone destruction determined by cone-beam computed tomography (CBCT) analysis. Moreover, the levels of bacteria and endotoxins were correlated with the development of clinical features. Twenty-four root canals with primary endodontic disease and apical periodontitis were selected. Clinical features such as pain on palpation, pain on percussion, and previous episode of pain were recorded. The volume (cubic millimeters) of periapical bone destruction was determined by CBCT analysis. Endotoxins and bacterial samplings were collected by using sterile/apyrogenic paper points. Endotoxins were quantified by using limulus amebocyte lysate assay (KQCL test), and bacterial count (colony-forming units [CFU]/mL) was determined by using anaerobic culture techniques. Data were analyzed by Pearson correlation and multiple logistic regression (P < .05). Endotoxins and bacteria were detected in 100% of the root canal samples (24 of 24), with median values of 10.92 endotoxin units (EU)/mL (1.75-128 EU/mL) and 7.5 × 10(5) CFU/mL (3.20 × 10(5)-8.16 × 10(6) CFU/mL), respectively. The median volume of bone destruction determined by CBCT analysis was 100 mm(3) (10-450 mm(3)). The multiple regression analysis revealed a positive correlation between higher levels of endotoxins present in root canal infection and larger volume of bone destruction (P < .05). Moreover, higher levels of endotoxins were also correlated with the presence of previous pain (P < .05). Our findings revealed that the levels of endotoxins found in root canal infection are related to the volume of periapical bone destruction determined by CBCT analysis. Moreover, the levels of endotoxin are related to the presence of previous pain.
Resumo:
The Morse Taper implant system, developed from its introduction in engineering, has become increasingly effective for use in dentistry. However, other systems, main external hexagon type, have been used more frequently today. Current studies have been reported the positive features of the Morse taper system and even emphasized as ideal within the systems used in implantology. Unfortunately, some professional duty by not knowing this system, or even prefer hexagon type system by decreased cost of components, have refused to use it. Thus, this study was aimed to perform a brief review of the Morse taper system, emphasizing its main points of interest in dentistry, in an attempt to familiarize the professionals to at least learn more about this system that has the prospect to become the leading system implants used in dentistry in the coming years. It is concluded that this system of dental implants is favorable showing predictability and success.
Resumo:
The purpose of this study was to analyze the biomechanical interactions in bone tissue between short implants and implant-supported crowns with different heights. Two models were made using the programs InVesalius 3.0, Rhinoceros 4.0 and Solidworks 2010. The models were established from a bone block with the short implant (3.75 x 8.5 mm) with geometry Morse taper connection (MT). The height of the crown (cemented) was set at 10.0 mm and 15.00 mm. The models were processed by programs and 10 NEiNastran Femap 10.0. The force applied was 200N (vertical) and 100N (oblique). The results were plotted on maps Voltage Maximum Principal. Statistical analysis was performed using ANOVA. The results showed that the increase in crown height, increased stress concentration in the crown of 15 mm under oblique loading (p <0.001), the oblique loading has significantly expanded the area of stress concentration (p <0.001). Conclusion:the increase of the crown increased the stress concentration, being statistically significant for short implants Morse taper. The mesial and distal region had the highest concentration of stresses under oblique loading. The oblique loading was more harmful when compared with axial loading, being statistically significant.