1000 resultados para COMPARATIVE PHARMACOKINETICS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent availability of the chicken genome sequence poses the question of whether there are human protein-coding genes conserved in chicken that are currently not included in the human gene catalog. Here, we show, using comparative gene finding followed by experimental verification of exon pairs by RT-PCR, that the addition to the multi-exonic subset of this catalog could be as little as 0.2%, suggesting that we may be closing in on the human gene set. Our protocol, however, has two shortcomings: (i) the bioinformatic screening of the predicted genes, applied to filter out false positives, cannot handle intronless genes; and (ii) the experimental verification could fail to identify expression at a specific developmental time. This highlights the importance of developing methods that could provide a reliable estimate of the number of these two types of genes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le concept de mécanismes de défense en psychanalyse fut introduit pour la première fois par S. Freud en¦1894 dans l'ouvrage Les psychonévroses de défense. Selon la définition qu'on lui donne de nos jours, ce¦concept regroupe « les processus psychiques inconscients visant à réduire ou annuler les effets désagréables des dangers réels ou imaginaires en remaniant les réalités internes et / ou externes et dont les manifestations peuvent être conscientes ou inconscientes1.»¦Les mécanismes de défense ne concernent d'ailleurs pas seulement les personnes souffrant d'un trouble¦psychiatrique, chacun de nous utilisant quotidiennement toutes sortes de défenses de quelque niveau de¦maturité qu'elles soient, nous permettant de nous adapter au contraintes affectives de tous les jours. Ils¦représentent de plus l'un des rares concepts en psychanalyse se prêtant à l'étude empirique, c'est pourquoi ils revêtent un grand intérêt dans la recherche actuellement. Grâce à l'élaboration d'une échelle d'évaluation de ces mécanismes par J. C. Perry (2009), le Defense Mechanisms Rating Scale, il est devenu possible de mettre en évidence « des liens entre les défenses et le niveau d'adaptation des patients, entre les défenses et la psychopathologie, et de montrer l'évolution des défenses au cours des psychothérapies psychanalytiques2.»¦Le DMRS comprend 28 défenses classées en 7 niveaux hiérarchiques en fonction de leur niveau¦d'adaptation. Il ne comprend cependant pas encore les défenses dites psychotiques. Toutefois, un groupe de travail s'attache à construire, puis à valider un instrument d'évaluation de ces mécanismes sous la forme d'un addendum au DMRS.¦Le but de mon travail sera d'évaluer quatre entretiens, deux de patients souffrant d'un trouble du spectre de la schizophrénie, deux d'un trouble bipolaire, sur la base des données recueillies par l'institut de¦psychothérapie du CHUV. A l'aide du DMRS, j'effectuerai une cotation de leur mécanismes de défense¦respectifs. Pour ce faire, il s'agira dans un premier temps de me familiariser avec l'outil qu'est le DMRS afin de pouvoir, dans un deuxième temps, mettre en évidence et analyser les mécanismes de défense utilisés par les patients lors de ces entretiens psychothérapeutiques. Les patients devraient montrer un niveau défensif global comparable, en vue de la gravité de leur pathologie. Cependant, des différences devraient apparaître quant aux catégories de défenses utilisées par chaque patient, puisque celles-ci dépendent de leur pathologie ainsi que de leur fonctionnement psychique pour faire face aux difficultés qu'il rencontre. Enfin, leurs niveaux défensifs seront pondérés par ce dont ils parleront dans l'entretien en question, en lien avec les interventions du thérapeute.¦Ce travail devrait me permettre de montrer que tout patient présente un large éventail de défenses, et pas¦seulement des défenses dites psychotiques. Il s'agira aussi de monter quelles sont les applications possibles et les limites de l'outil qu'est le DMRS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evidence exists that many natural facts are described better as a fractal. Although fractals are very useful for describing nature, it is also appropiate to review the concept of random fractal in finance. Due to the extraordinary importance of Brownian motion in physics, chemistry or biology, we will consider the generalization that supposes fractional Brownian motion introduced by Mandelbrot.The main goal of this work is to analyse the existence of long range dependence in instantaneous forward rates of different financial markets. Concretelly, we perform an empirical analysis on the Spanish, Mexican and U.S. interbanking interest rate. We work with three time series of daily data corresponding to 1 day operations from 28th March 1996 to 21st May 2002. From among all the existing tests on this matter we apply the methodology proposed in Taqqu, Teverovsky and Willinger (1995).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to determine whether thoracic endovascular aortic repair (TEVAR) reduces death and morbidity compared with open surgical repair for descending thoracic aortic disease. BACKGROUND: The role of TEVAR versus open surgery remains unclear. Metaregression can be used to maximally inform adoption of new technologies by utilizing evidence from existing trials. METHODS: Data from comparative studies of TEVAR versus open repair of the descending aorta were combined through meta-analysis. Metaregression was performed to account for baseline risk factor imbalances, study design, and thoracic pathology. Due to significant heterogeneity, registry data were analyzed separately from comparative studies. RESULTS: Forty-two nonrandomized studies involving 5,888 patients were included (38 comparative studies, 4 registries). Patient characteristics were balanced except for age, as TEVAR patients were usually older than open surgery patients (p = 0.001). Registry data suggested overall perioperative complications were reduced. In comparative studies, all-cause mortality at 30 days (odds ratio [OR]: 0.44, 95% confidence interval [CI]: 0.33 to 0.59) and paraplegia (OR: 0.42, 95% CI: 0.28 to 0.63) were reduced for TEVAR versus open surgery. In addition, cardiac complications, transfusions, reoperation for bleeding, renal dysfunction, pneumonia, and length of stay were reduced. There was no significant difference in stroke, myocardial infarction, aortic reintervention, and mortality beyond 1 year. Metaregression to adjust for age imbalance, study design, and pathology did not materially change the results. CONCLUSIONS: Current data from nonrandomized studies suggest that TEVAR may reduce early death, paraplegia, renal insufficiency, transfusions, reoperation for bleeding, cardiac complications, pneumonia, and length of stay compared with open surgery. Sustained benefits on survival have not been proven.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasmid DNA and adenovirus vectors currently used in cardiovascular gene therapy trials are limited by low efficiency and short-lived transgene expression, respectively. Recombinant adeno-associated virus (AAV) has recently emerged as an attractive vector for cardiovascular gene therapy. In the present study, we have compared AAV and adenovirus vectors with respect to gene transfer efficiency and the duration of transgene expression in mouse hearts and arteries in vivo. AAV vectors (titer: 5 x 10(8) transducing units (TU)/ml) and adenovirus vectors (1.2 x 10(10) TU/ml) expressing a green fluorescent protein (EGFP) gene were injected either intramyocardially (n=32) or intrapericardially (n=3) in CD-1 mice. Hearts were harvested at varying time intervals (3 days to 1 year) after gene delivery. After intramyocardial injection of 5 microl virus stock solution, cardiomyocyte transduction rates with AAV vectors were 4-fold lower than with adenovirus vectors (1.5% (range: 0.5-2.6%) vs. 6.2% (range: 2.7-13.7%); P<0.05), but similar to titer-matched adenovirus vectors (0.7%; range: 0.2-1.2%). AAV-mediated EGFP expression lasted for at least 1 year. AAV vectors instilled into the pericardial space transduced epicardial myocytes. Arterial gene transfer was studied in mouse carotids (n=26). Both vectors selectively transduced endothelial cells after luminal instillation. Transduction rates with AAV vectors were 8-fold lower than with adenovirus vectors (2.0% (range: 0-3.2%) vs. 16.2% (range: 8.5-20.2%); P<0.05). Prolonged EGFP expression was observed after AAV but not adenovirus-mediated gene transfer. In conclusion, AAV vectors deliver and express genes for extended periods of time in the myocardium and arterial endothelium in vivo. AAV vectors may be useful for gene therapy approaches to chronic cardiovascular diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The combination of embolic beads with a multitargeted tyrosine kinase inhibitor that inhibits tumor vessel growth is suggested as an alternative and improvement to the current standard doxorubicin-eluting beads for use in transarterial chemoembolization. This study demonstrates the in vitro loading and release kinetics of sunitinib using commercially available embolization microspheres and evaluates the in vitro biologic efficacy on cell cultures and the resulting in vivo pharmacokinetics profiles in an animal model. MATERIALS AND METHODS: DC Bead microspheres, 70-150 µm and 100-300 µm (Biocompatibles Ltd., Farnham, United Kingdom), were loaded by immersion in sunitinib solution. Drug release was measured in saline in a USP-approved flow-through apparatus and quantified by spectrophotometry. Activity after release was confirmed in cell culture. For pharmacokinetics and in vivo toxicity evaluation, New Zealand white rabbits received sunitinib either by intraarterial injection of 100-300 µm sized beads or per os. Plasma and liver tissue drug concentrations were assessed by liquid chromatography-tandem mass spectroscopy. RESULTS: Sunitinib loading on beads was close to complete and homogeneous. A total release of 80% in saline was measured, with similar fast-release profiles for both sphere sizes. After embolization, drug plasma levels remained below the therapeutic threshold (< 50 ng/mL), but high concentrations at 6 hours (14.9 µg/g) and 24 hours (3.4 µg/g) were found in the liver tissue. CONCLUSIONS: DC Bead microspheres of two sizes were efficiently loaded with sunitinib and displayed a fast and almost complete release in saline. High liver drug concentrations and low systemic levels indicated the potential of sunitinib-eluting beads for use in embolization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthese :Comparaison des effets vasculaires et tubulaires rénaux de plusieurs antagonistes des récepteurs de |'angiotensine II en combinaison avec un diurétique thiazidique chez l'humainObjectif : Le but de ce travail était d'investiguer si les antagonistes des récepteurs AT1 de l'angiotensine II (ARA2) entraînent un blocage équivalent des récepteurs au niveau vasculaire et au niveau rénal, en particulier lorsque le système rénine- angiotensine est stimulé par l'administration d'un diurétique thiazidique. Méthode : trente volontaires masculins en bonne santé ont participé à cette étude randomisée, contrôlée, en simple insu. Nous avons mesuré les variations de pression artérielle, d'hémodynamique rénale ainsi que la réponse tubulaire rénale à une perfusion d'angiotensine II 3ng/kg/min administrée sur 1 heure. Ceci avant traitement puis après sept jours d'administration, 24 heures après la dernière dose de médicament. Nous avons comparé l'irbésartan 300 mg seul ou en association avec 12.5 ou 25 mg d'hydrochlorothiazide. (irbésartan 300/12.5 ; irbésartan 300/25). Nous avons également comparé les effets de l'irbésartan 300/25 au losartan 100 mg, au valsartan 160 mg ainsi qu'à l'olmésartan 20 mg, tous administrés avec 25 mg d'hydrochlorothiazide. Chaque participant a été randomisé pour recevoir 2 traitements de 7 jours espacés d'une période d'une semaine sans traitement. Résultats: La réponse de la pression artérielle à |'angiotensine II exogène était bloquée >90% avec l'irbésartan 300 mg seul ou en association avec le diurétique. Il en était de même avec l'olmésartan 20/25. Par contre le blocage n'était que de 60% environ dans les groupes valsartan 160/25 et losartan 100/25. Au niveau rénal, |'angiotensine II exogène réduisait le flux plasmatique rénal de 36% en pré- traitement. Dans les groupes recevant l'irbésartan 300 mg et l'olmésartan 20 mg associés à l'hydrochlorothiazide 25 mg, la vasoconstriction rénale était bloquée presque entièrement alors qu'el|e ne |'était que partiellement avec le valsartan 160/25 et le losartan 100/25 (34 et 45%, respectivement). En pré-traitement, au niveau tubulaire, l'angiotensine II exogène réduisait le volume urinaire de 84% et l'excrétion urinaire de sodium de 65 %. Les effets tubulaires n'étaient que partiellement bloqués par l'administration d'ARA2. Conclusion: Ces résultats démontrent que les ARA; aux doses maximales recommandées ne bloquent pas aussi efficacement les récepteurs ATI au niveau tubulaire qu'au niveau vasculaire. Cette observation pourrait constituer une justification à l'hypothèse selon laquelle des doses plus importantes d'ARA2 seraient nécessaires afin d'obtenir une meilleure protection d'organe. De plus, nos résultats confirment qu'i| y a d'importantes différences entre les ARA2, relatives à leur capacité d'induire un blocage prolongé sur 24 heures des récepteurs AT1 au niveau vasculaire et tubulaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Intimal hyperplasia (IH) is a vascular remodeling process which often leads to failure of arterial bypass or hemodialysis access. Experimental and clinical work have provided insight in IH development; however, further studies under precise controlled conditions are required to improve therapeutic strategies to inhibit IH development. Ex vivo perfusion of human vessel segments under standardized hemodynamic conditions may provide an adequate experimental approach for this purpose. Therefore, chronically perfused venous segments were studied and compared to traditional static culture procedures with regard to functional and histomorphologic characteristics as well as gene expression. MATERIALS AND METHODS: Static vein culture allowing high tissue viability was performed as previously described. Ex vivo vein support system (EVVSS) was performed using a vein support system consisting of an incubator with a perfusion chamber and a pump. EVVSS allows vessel perfusion under continuous flow while maintaining controlled hemodynamic conditions. Each human saphenous vein was divided in two parts, one cultured in a Pyrex dish and the other part perfused in EVVSS for 14days. Testing of vasomotion, histomorphometry, expression of CD 31, Factor VIII, MIB 1, alpha-actin, and PAI-l were determined before and after 14days of either experimental conditions. RESULTS: Human venous segments cultured under traditional or perfused conditions exhibited similar IH after 14 days as shown by histomorphometry. Smooth-muscle cell (SMC) was preserved after chronic perfusion. Although integrity of both endothelial and smooth-muscle cells appears to be maintained in both culture conditions as confirmed by CD31, factor VIII, and alpha-actin expression, a few smooth-muscle cells in the media stained positive for factor VIII. Cell-proliferation marker MIB-1 was also detected in the two settings and PAI-1 mRNA expression and activity increased significantly after 14 days of culture and perfusion. CONCLUSION: This study demonstrates the feasibility to chronically perfuse human vessels under sterile conditions with preservation of cellular integrity and vascular contractility. To gain insights into the mechanisms leading to IH, it will now be possible to study vascular remodeling not only under static conditions but also in hemodynamic environment mimicking as closely as possible the flow conditions encountered in reconstructive vascular surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evolution of continuous traits is the central component of comparative analyses in phylogenetics, and the comparison of alternative models of trait evolution has greatly improved our understanding of the mechanisms driving phenotypic differentiation. Several factors influence the comparison of models, and we explore the effects of random errors in trait measurement on the accuracy of model selection. We simulate trait data under a Brownian motion model (BM) and introduce different magnitudes of random measurement error. We then evaluate the resulting statistical support for this model against two alternative models: Ornstein-Uhlenbeck (OU) and accelerating/decelerating rates (ACDC). Our analyses show that even small measurement errors (10%) consistently bias model selection towards erroneous rejection of BM in favour of more parameter-rich models (most frequently the OU model). Fortunately, methods that explicitly incorporate measurement errors in phylogenetic analyses considerably improve the accuracy of model selection. Our results call for caution in interpreting the results of model selection in comparative analyses, especially when complex models garner only modest additional support. Importantly, as measurement errors occur in most trait data sets, we suggest that estimation of measurement errors should always be performed during comparative analysis to reduce chances of misidentification of evolutionary processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.