976 resultados para CHEMICAL-REDUCTION
Resumo:
The development and applications of thermoset polymeric composites, namely fibre reinforced plastics (FRP), have shifted in the last decades more and more into the mass market [1]. Despite of all advantages associated to FRP based products, the increasing production and consume also lead to an increasing amount of FRP wastes, either end-of-lifecycle products, or scrap and by-products generated by the manufacturing process itself. Whereas thermoplastic FRPs can be easily recycled, by remelting and remoulding, recyclability of thermosetting FRPs constitutes a more difficult task due to cross-linked nature of resin matrix. To date, most of the thermoset based FRP waste is being incinerated or landfilled, leading to negative environmental impacts and supplementary added costs to FRP producers and suppliers. This actual framework is putting increasing pressure on the industry to address the options available for FRP waste management, being an important driver for applied research undertaken cost efficient recycling methods. [1-2]. In spite of this, research on recycling solutions for thermoset composites is still at an elementary stage. Thermal and/or chemical recycling processes, with partial fibre recovering, have been investigated mostly for carbon fibre reinforced plastics (CFRP) due to inherent value of carbon fibre reinforcement; whereas for glass fibre reinforced plastics (GFRP), mechanical recycling, by means of milling and grinding processes, has been considered a more viable recycling method [1-2]. Though, at the moment, few solutions in the reuse of mechanically-recycled GFRP composites into valueadded products are being explored. Aiming filling this gap, in this study, a new waste management solution for thermoset GFRP based products was assessed. The mechanical recycling approach, with reduction of GFRP waste to powdered and fibrous materials was applied, and the potential added value of obtained recyclates was experimentally investigated as raw material for polyester based mortars. The use of a cementless concrete as host material for GFRP recyclates, instead of a conventional Portland cement based concrete, presents an important asset in avoiding the eventual incompatibility problems arisen from alkalis silica reaction between glass fibres and cementious binder matrix. Additionally, due to hermetic nature of resin binder, polymer based concretes present greater ability for incorporating recycled waste products [3]. Under this scope, different GFRP waste admixed polymer mortar (PM) formulations were analyzed varying the size grading and content of GFRP powder and fibre mix waste. Added value of potential recycling solution was assessed by means of flexural and compressive loading capacities of modified mortars with regard to waste-free polymer mortars.
Resumo:
Prescribed fire is a common forest management tool used in Portugal to reduce the fuel load availability and minimize the occurrence of wildfires. In addition, the use of this technique also causes an impact to ecosystems. In this presentation we propose to illustrate some results of our project in two forest sites, both located in Northwest Portugal, where the effect of prescribed fire on soil properties were recorded during a period of 6 months. Changes in soil moisture, organic matter, soil pH and iron, were examined by Principal Component Analysis multivariate statistics technique in order to determine impact of prescribed fire on these soil properties in these two different types of soils and determine the period of time that these forest soils need to recover to their pre-fire conditions, if they can indeed recover. Although the time allocated to this study does not allow for a widespread conclusion, the data analysis clearly indicates that the pH values are positively correlated with iron values at both sites. In addition, geomorphologic differences between both sampling sites, Gramelas and Anjos, are relevant as the soils’ properties considered have shown different performances in time. The use of prescribed fire produced a lower impact in soils originated from more amended bedrock and therefore with a ticker humus covering (Gramelas) than in more rocky soils with less litter covering (Anjos) after six months after the prescribed fire occurrence.
Resumo:
The Portuguese northern forests are often and severely affected by wildfires during the summer season. These occurrences affect significant and rudely all ecosystems, namely soil, fauna and flora. Preventive actions such as prescribed burnings and clear-cut logging are frequently used and have showed a significant reduction of the natural wildfires occurrences. In Portugal, and due to some technical and operational conditions, prescribed burnings in forests are the most common preventive action used to reduce the existing fuel hazard. The overall impacts of this preventive action on Portuguese ecosystems are complex and not fully understood. This work reports to the study of a prescribed burning impact in soil chemical properties, namely pH, humidity and organic matter, by monitoring the soil self-recovery capacity. The experiments were carried out in soil cover over a natural site of Andaluzitic schist, in Gramelas, Caminha, Portugal, who was able to maintain itself intact from prescribed burnings from four years. The composed soil samples were collected from five plots at three different layers (0-3cm, 3-6cm and 6-18cm) 1 day before prescribed fire and after the prescribed fire. The results have shown that the dynamic equilibrium in soil was affected significantly.
Physical, chemical and mineralogical properties of fine recycled aggregates made from concrete waste
Resumo:
This paper assesses the physical, chemical and mineralogical characteristics of fine recycled aggregates obtained from crushed concrete waste, comparing them with two types of natural fine aggregates from different origins. A commercial concrete was jaw crushed, and the effect of different aperture sizes on the particle size distribution of the resulting aggregates was evaluated. The density and water absorption of the recycled aggregates was determined and a model for predicting water absorption over time is proposed. Both natural and recycled aggregates were characterized regarding bulk density and fines content. Recycled aggregates were additionally characterized by XRD, SEM/EDS and DTA/TG of individual size fractions. The results show that natural and recycled fine aggregates have very different characteristics. This should be considered in potential applications, both in terms of the limits for replacing amounts and of the rules and design criteria of the manufactured products. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
An abstract theory on general synchronization of a system of several oscillators coupled by a medium is given. By generalized synchronization we mean the existence of an invariant manifold that allows a reduction in dimension. The case of a concrete system modeling the dynamics of a chemical solution on two containers connected to a third container is studied from the basics to arbitrary perturbations. Conditions under which synchronization occurs are given. Our theoretical results are complemented with a numerical study.
Resumo:
Materials selection is a matter of great importance to engineering design and software tools are valuable to inform decisions in the early stages of product development. However, when a set of alternative materials is available for the different parts a product is made of, the question of what optimal material mix to choose for a group of parts is not trivial. The engineer/designer therefore goes about this in a part-by-part procedure. Optimizing each part per se can lead to a global sub-optimal solution from the product point of view. An optimization procedure to deal with products with multiple parts, each with discrete design variables, and able to determine the optimal solution assuming different objectives is therefore needed. To solve this multiobjective optimization problem, a new routine based on Direct MultiSearch (DMS) algorithm is created. Results from the Pareto front can help the designer to align his/hers materials selection for a complete set of materials with product attribute objectives, depending on the relative importance of each objective.
Resumo:
The cleaning of syngas is one of the most important challenges in the development of technologies based on gasification of biomass. Tar is an undesired byproduct because, once condensed, it can cause fouling and plugging and damage the downstream equipment. Thermochemical methods for tar destruction, which include catalytic cracking and thermal cracking, are intrinsically attractive because they are energetically efficient and no movable parts are required nor byproducts are produced. The main difficulty with these methods is the tendency for tar to polymerize at high temperatures. An alternative to tar removal is the complete combustion of the syngas in a porous burner directly as it leaves the particle capture system. In this context, the main aim of this study is to evaluate the destruction of the tar present in the syngas from biomass gasification by combustion in porous media. A gas mixture was used to emulate the syngas, which included toluene as a tar surrogate. Initially, CHEMKIN was used to assess the potential of the proposed solution. The calculations revealed the complete destruction of the tar surrogate for a wide range of operating conditions and indicated that the most important reactions in the toluene conversion are C6H5CH3 + OH <-> C6H5CH2 + H2O, C6H5CH3 + OH <-> C6H4CH3 + H2O, and C6H5CH3 + O <-> OC6H4CH3 + H and that the formation of toluene can occur through C6H5CH2 + H <-> C6H5CH3. Subsequently, experimental tests were performed in a porous burner fired with pure methane and syngas for two equivalence ratios and three flow velocities. In these tests, the toluene concentration in the syngas varied from 50 to 200 g/Nm(3). In line with the CHEMKIN calculations, the results revealed that toluene was almost completely destroyed for all tested conditions and that the process did not affect the performance of the porous burner regarding the emissions of CO, hydrocarbons, and NOx.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro,Área de especialização Cerâmica e Vidro
Resumo:
Actas do 17º Congresso da Associação Internacional para a História do Vidro
Resumo:
Mestrado em Engenharia Mecânica- Energia
Resumo:
The most practicable assay for measurement of measles IgG (mIgG) in large numbers of sera is an enzyme immunoassay (EIA). To assess how EIA results would agree with those by the gold standard method of plaque reduction neutralization (PRN) we compared the results from the two methods in 43 pairs of maternal and umbilical cord sera, and sera from the corresponding infants when aged 11 - 14 months. In maternal-cord sera, the differences between mean antibody levels by EIA or PRN were not statistically significant, though in individual sera, differences could be large. However, agreement was less good for infants sera, in which levels of mIgG were very low. The conclusions of a study of transplacental transport of mIgG would not be affected by the use of either technique. When studying waning immunity in infants, PRN should be the method of choice, while results from studies using EIA should be interpreted with caution.
Resumo:
A presente dissertação tem como principal propósito avaliar o desempenho energético e a qualidade do ar interior do edifício principal do Parque Biológico de Vila Nova de Gaia (PBG). Para esse efeito, este estudo relaciona os termos definidos na legislação nacional em vigor até à presente data, e referentes a esta área de atuação, em particular, os presentes no SCE, RSECE, RCCTE e RSECE-QAI. Para avaliar o desempenho energético, procedeu-se numa primeira fase ao processo de auditoria no local e posteriormente à realização de uma simulação dinâmica detalhada, cuja modelação do edifício foi feita com recurso ao software DesignBuilder. Após a validação do modelo simulado, por verificação do desvio entre os consumos energéticos registados nas faturas e os calculados na simulação, igual a 5,97%, foi possível efetuar a desagregação dos consumos em percentagem pelos diferentes tipos de utilizações. Foi também possível determinar os IEE real e nominal, correspondendo a 29,9 e 41.3 kgep/m2.ano, respetivamente, constatando-se através dos mesmos que o edifício ficaria dispensado de implementar um plano de racionalização energética (PRE) e que a classe energética a atribuir é a C. Contudo, foram apresentadas algumas medidas de poupança de energia, de modo a melhorar a eficiência energética do edifício e reduzir a fatura associada. Destas destacam-se duas propostas, a primeira propõe a alteração do sistema de iluminação interior e exterior do edifício, conduzindo a uma redução no consumo de eletricidade de 47,5 MWh/ano, com um período de retorno de investimento de 3,5 anos. A segunda está relacionada com a alteração do sistema de produção de água quente para o aquecimento central, através do incremento de uma caldeira a lenha ao sistema atual, que prevê uma redução de 50 MWh no consumo de gás natural e um período de retorno de investimento de cerca de 4 anos. Na análise realizada à qualidade do ar interior (QAI), os parâmetros quantificados foram os exigidos legalmente, excetuando os microbiológicos. Deste modo, para os parâmetros físicos, temperatura e humidade relativa, obtiveram-se os resultados médios de 19,7ºC e 66,9%, respetivamente, ligeiramente abaixo do previsto na legislação (20,0ºC no período em que foi feita a medição, inverno). No que diz respeito aos parâmetros químicos, os valores médios registados para as concentrações de dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCHO), partículas em suspensão (PM10) e radão, foram iguais a 580 ppm, 0,2 ppm, 0,06 ppm, 0,01 ppm, 0,07 mg/m3 e 196 Bq/m3, respetivamente, verificando-se que estão abaixo dos valores máximos de referência presentes no regulamento (984 ppm, 10,7 ppm, 0,10 ppm, 0,08 ppm, 0,15 mg/m3 e 400 Bq/m3). No entanto, o parâmetro relativo aos compostos orgânicos voláteis (COV) teve um valor médio igual a 0,84 ppm, bastante acima do valor máximo de referência (0,26 ppm). Neste caso, terá que ser realizada uma nova série de medições utilizando meios cromatográficos, para avaliar qual(ais) são o(s) agente(s) poluidor(es), de modo a eliminar ou atenuar as fontes de emissão.
Resumo:
Antigenic preparations (saline, methylic, metabolic and exoantigens) of four agents of chromoblastomycosis, Fonsecaea pedrosoi, Phialophora verrucosa, Cladophialophora (Cladosporium) carrionii and Rhinocladiella aquaspersa were obtained. Partial chemical characterization of these antigenic preparations was obtained by determination of the levels of total lipids, protein, and carbohydrates, and identification of the main sterols and carbohydrates. Methylic antigens presented the highest lipid contents, whereas metabolic antigens showed the highest carbohydrate content. Total lipid, protein, and carbohydrate levels were in the range of 2.33 to 2.00mg/ml, 0.04 to 0.02 mg/ml and 0.10 to 0.02 mg/ml, respectively, in the methylic antigens and in the range of 0.53 to 0.18mg/ml, 0.44 to 0.26mg/ml, and 1.82 to 1.02 mg/ml, respectively, in saline antigens. Total lipid, protein, and carbohydrate contents were in the range of 0.55 to 0.20mg/ml, 0.69 to 0.57mg/ml and 10.73 to 5.93mg/ml, respectively, in the metabolic antigens, and in the range of 0.55 to 0.15mg/ml, 0.62 to 0.20mg/ml and 3.55 to 0.42mg/ml, respectively, in the exoantigens. Phospholipids were not detected in the preparations. Saline and metabolic antigens and exoantigens presented hexose and the methylic antigen revealed additional pentose units in their composition. The UV light absorption spectra of the sterols revealed squalene and an ergosterol fraction in the antigens. The characterization of these antigenic preparations may be useful for serological evaluation of patients of chromoblastomycosis.
Resumo:
Evidence indicates that exposure to high levels of noise adversely affects human health, and these effects are dependent upon various factors. In hospitals, there are many sources of noise, and high levels exert an impact on patients and staff, increasing both recovery time and stress, respectively. The goal of this pilot study was to develop, implement and evaluate the effectiveness of a training program (TP) on noise reduction in a Neonatal Intensive Care Units (NICU) by comparing the noise levels before and after the implementation of the program. A total of 79 health professionals participated in the study. The measurements of sound pressure levels took into account the layout of the unit and location of the main sources of noise. General results indicated that LAeq levels before implementation of the training program were often excessive, ranging from 48.7 ± 2.94 dBA to 71.7 ± 4.74 dBA, exceeding international guidelines. Similarly following implementation of the training program noise levels remained unchanged (54.5 ± 0.49 dBA to 63.9 ± 4.37 dBA), despite a decrease in some locations. There was no significant difference before and after the implementation of TP. However a significant difference was found for Lp, Cpeak, before and after training staff, suggesting greater care by healthcare professionals performing their tasks. Even recognizing that a TP is quite important to change behaviors, this needs to be considered in a broader context to effectively control noise in the NICU.
Resumo:
Dissertation submitted to obtain the phD degree in Biochemistry, specialty in Physical- Biochemistry, by the Faculdade de Ciências e Tecnologia from the Universidade Nova de Lisboa