985 resultados para Antibodies, Monoclonal, Humanized
Resumo:
Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.
Resumo:
In a transversal study on a sample of 386 children and adolescents from an outpatient clinic for filariasis in Recife, Northeast Brazil, the frequency of anti-Toxocara antibodies and its relation to age, gender, number of peripheral eosinophils, Wuchereria bancrofti microfilariae and intestinal helminths was determined. The total anti-Toxocara IgG antibody frequency was 39.4%, by ELISA technique. The difference in frequency between males (40.1%) and females (37.6%) was not statistically significant. The 6 to 10-year-old subset presented the highest frequency of anti-Toxocara antibodies (60%), and within this age group there was a statistically significant male bias. There was also a significant association between the number of eosinophils and the presence of anti-Toxocara antibodies. Intestinal parasite frequency was 52.1%, but no association was found between this data and the presence of anti-Toxocara antibodies. In the present sample, 42.2% of the patients were Wuchereria bancrofti carriers, however, again this was not associated with the presence of anti-Toxocara antibodies. In conclusion, anti-Toxocara antibodies were highly prevalent in this sample. The present data show that there is no cross correlation between anti-Toxocara IgG antibody and the presence of intestinal helminths and filariasis.
Resumo:
The purpose of the study was to estimate the prevalence of IgG antibodies against varicella zoster virus (VZV) in the two most populated indigenous ethnic groups from Xingu Indigenous National Park, in Brazil, prior to the introduction of vaccination against the disease, and to determine the positive and the negative predictive values of a history of varicella infection. In 2001, 589 inhabitants of two Kuikuro villages and three Kaiabi villages were evaluated and provided information concerning previous varicella infection. An indirect immunosorbent assay (ELISA) to detect IgG anti-VZV antibodies was performed in 224 blood samples - volunteer selection had no interference of anamnesis. IgG prevalence was 80.8% (95% Confidence Interval: 76% - 86%). The seroepidemiology of varicella in Xingu National Park prior to varicella vaccine introduction was comparable to the Brazilian national seroprevalence described in the literature, and so were the positive (98%) and the negative predictive value (41%) of the referred history.
Resumo:
Previous experiences have demonstrated the same ABO system and P system antigens in A. lumbricoides extracts and in their hosts. The aim was to show the behavior of an A. lumbricoides extract from an O Group patient against monoclonal antibodies of different specificities. Agglutination Inhibition Tests were carried out facing the extract against monoclonal antibodies (anti A 2.23; anti B 2.54; anti B 2.62; anti AB 2.39 and anti H 2.72) in optimal concentrations. Suspensions of O Group fresh red cells were used as revealing system. The extract only inhibited the agglutination of anti H 2.72 with O erythrocytes. The semiquantitative Agglutination Inhibition Test of the extract was made against two series of anti H 2.72 dilutions by using O Group fresh red cells as revealing system. A difference of five dilutions between the titers of both series has been observed and the presence of H Antigen in the extract has been significantly confirmed. The fact that the extract did not inhibit the agglutination against anti A, anti B and anti AB has corroborated our previous observations about absence of A and B epitopes in A. lumbricoides extracts from O Group patients. The results of the preceding studies and this experience have demonstrated the membrane glycoconjugated importance in A. lumbricoides. They could be involved in molecular mimicry for this parasite.
Resumo:
The aim of the present study was to screen the serum of blood donors, which are apparently healthy and residing in Pondicherry or its neighboring districts of Tamil Nadu State, for specific detection of Cysticercus antigens and antibodies. A total of 216 blood samples were collected from blood donors at the Central Blood Bank, JIPMER Hospital, Pondicherry, India during January and February 2004. Enzyme-linked immunosorbent assay (ELISA) was used to demonstrate anti-Cysticercus antibodies and the Co-agglutination (CoA) was used to detect antigen in sera. 14 (6.48 %) males were positive for either anti-Cysticercus antibodies or antigens. Of these eight sera were positive for anti-Cysticercus antibodies and six were positive for antigens. Results of the present study show that serum Cysticercus antigen detection may be a useful adjunct to antibody testing for seroprevalence studies of cysticercosis in the community. The present study is the first kind of study, carried out to determine both cysticercal antibodies as well as antigens in the serum samples collected from the healthy blood donors.
Resumo:
This paper reports the isolation of St. Louis encephalitis virus (SLEV) from a febrile human case suspected to be dengue, in São Pedro, São Paulo State. A MAC-ELISA done on the patient's acute and convalescent sera was inconclusive and hemagglutination inhibition test detected IgG antibody for flaviviruses. An indirect immunofluorescent assay done on the C6/36 cell culture inoculated with the acute serum was positive for flaviviruses but negative when tested with dengue monoclonal antibodies. RNA extracted from the infected cell culture supernatant was amplified by RT-PCR in the presence of NS5 universal flavivirus primers and directly sequenced. Results of BLAST search indicated that this sequence shares 93% nucleotide similarity with the sequence of SLEV (strain-MSI.7), confirmed by RT-PCR performed with SLEV specific primers. Since SLEV was identified as the cause of human disease, it is necessary to improve surveillance in order to achieve early detection of this agent in the state of São Paulo and in Brazil. This finding is also an alert to health professionals about the need for more complete clinical and epidemiological investigations of febrile illnesses as in the reported case. SLEV infections can be unrecognized or confused with other ones caused by an arbovirus, such as dengue.
Resumo:
A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB). Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51). The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5%) and 47-52 kDa (80%). The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001). In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.
Resumo:
Antibody in human sera that induces lysis of sheep erythrocytes in hemolytic assay was investigated. The present study showed that the presence in serum of the thermostable cytolytic anti-sheep red blood cells antibodies is dependent on the Schistosoma mansoni infection, and this is more frequent in adults than in children. The thermostable characteristic of hemolysins in normal sera was not dependent on the presence of Ascaris lumbricoides, Trichuris trichiura or hookworm geo-helminths. Further, thermostable complement-activating heterophile antibodies were noticed in children in association with massive number of S. mansoni eggs. The results were obtained by using the z- and the chi-square tests. The z-test allows us to formulate a one-sided alternative, i.e., a tendency of one of the attributes. On the other hand, the chi-square test analyzes the independence between attributes by using a contingency table. Besides the obtained results being interesting in the field of schistosomiasis mansoni, they can provide a new insight into the use of statistics in medical science.
Resumo:
The diagnosis of American cutaneous leishmaniasis (ACL) is frequently based on clinical and epidemiological data associated with the results of laboratory tests. Some laboratory methods are currently being applied for the diagnosis of ACL, among them the indirect immunofluorescence reaction (IIFR), the Montenegro skin test (MST), histopathological examination, and the polymerase chain reaction (PCR). The performance of these methods varies in a considerable proportion of patients. After the standardization of an immunoenzymatic test (ELISA) for the detection of IgG in the serum of patients with ACL using a crude Leishmania braziliensis antigen, the results obtained were compared to those of other tests routinely used for the diagnosis. The tests revealed the following sensitivity, when analyzed separately: 85% for ELISA IgG, 81% for PCR, 64.4% for MST, 58.1% for IIFR, and 34% for the presence of parasites in the biopsy. ELISA was positive in 75% of patients with ACL presenting a negative MST, in 84.8% of ACL patients with negative skin or mucous biopsies for the presence of the parasite, and in 100% of cases with a negative PCR. Thus, ELISA presented a higher sensitivity than the other tests and was useful as a complementary method for the diagnosis of ACL.
Resumo:
Herpes simplex virus type 1 (HSV-1) ophthalmic disease is the most common cause of corneal blindness in humans world-wide. Current culture techniques for HSV take several days and commercially available HSV laboratory based diagnostic techniques vary in sensitivity. Our study was conducted to evaluate the use of a quicker and simpler method to herpes ophthalmic diagnosis. Corneal smears were made by firm imprints of infected mouse eyes to glass slides, after smears were fixated with cold acetone, and an indirect immunofluorescence (IIF) method was performed using monoclonal antibodies in a murine model of ophthalmic herpes. Eye swabs from infected mice were inoculated in Vero cells for virus isolation. Cytology and histology of the eye were also performed, using hematoxylin-eosin routine. Mouse eyes were examined by slit-lamp biomicroscopy for evidence of herpetic disease at various times postinoculation. We made a comparative evaluation of sensitivity, specificity and speed of methods for laboratory detection of HSV. Our results indicate that this IIF method is quick, sensitive, specific and can be useful in the diagnosis of ophthalmic herpes as demonstrated in an animal model.
Resumo:
A gold nanoparticle-coated screen-printed carbon electrode was used as the transducer in the development of an electrochemical immunosensor for Ara h 1 (a major peanut allergen) detection in food samples. Gold nanoparticles (average diameter=32 nm) were electrochemically generated on the surface of screen-printed carbon electrodes. Two monoclonal antibodies were used in a sandwich-type immunoassay and the antibody–antigen interaction was electrochemically detected through stripping analysis of enzymatically (using alkaline phosphatase) deposited silver. The total time of the optimized immunoassay was 3 h 50 min. The developed immunosensor allowed the quantification of Ara h 1 between 12.6 and 2000 ng/ml, with a limit of detection of 3.8 ng/ml, and provided precise (RSD <8.7%) and accurate (recovery >96.6%) results. The immunosensor was successfully applied to the analysis of complex food matrices (cookies and chocolate), being able to detect Ara h 1 in samples containing 0.1% of peanut.
Resumo:
A seroprevalence study to detect total antibodies against Hepatitis A Virus was done with 220 samples from 589 Native Indians from Xingu National Park, Brazil, in five Kaiabi and Kuikuro villages, the most populous ethnic groups. Using a commercial immunoassay kit we detected 97.7% positive samples (95% Confidence Interval: 95%-99%). We noticed a precocious seroconversion, before the age of six years, when the disease is usually asymptomatic. These results are similar to those found in the literature in non-Indian population studies of the Northern, Northeastern and West Central regions of Brazil. They suggest that it is not necessary to introduce vaccination against Hepatitis A in these highly endemic populations.
Resumo:
Interferon-beta (IFN-beta) therapy for multiple sclerosis (MS) is associated with a potential for induction of neutralizing antibodies (NAbs). Because immune reactivity depends on changes in lipoprotein metabolism, we investigated whether plasma lipoprotein profiles could be associated with the development of NAbs. Thirty-one female MS patients treated with subcutaneously administered IFN-beta were included. Demographic and clinical characteristics were compared between NAbs response groups using t tests for continuous and logistic regression analysis and Fisher's exact tests for categorical data, respectively. Multivariate logistic regression was used to evaluate the effect of potential confounders. Patients who developed NAbs had lower apoE levels before treatment, 67 (47-74) mg/L median (interquartile range), and at the moment of NAb analysis, 53 (50-84) mg/L, in comparison to those who remained NAb-negative, 83 (68-107) mg/L, P = 0.03, and 76 (66-87) mg/L, P = 0.04, respectively. When adjusting for age and smoking for a one-standard deviation decrease in apoE levels, a 5.6-fold increase in the odds of becoming NAb-positive was detected: odds ratios (OR) 0.18 (95% CI 0.04-0.77), P = 0.04. When adjusting for apoE, smoking habit became associated with NAb induction: OR 5.6 (95% CI 1.3-87), P = 0.03. These results suggest that apoE-containing lipoprotein metabolism and, possibly, tobacco smoking may be associated with risk of NAb production in female MS patients treated with IFN-beta.
Resumo:
Considering the scarcity of defined antigens, actually useful and reliable for use in the field studies, we propose an alternative method for selection of cDNA clones with potential use in the diagnosis of schistosomiasis. Human antibodies specific to a protein fraction of 31/32 kDa (Sm31/32), dissociated from immune complexes, are used for screening of clones from an adult worm cDNA library. Partial sequencing of five clones, selected through this strategy, showed to be related to Schistosoma mansoni: two were identified as homologous to heat shock protein 70, one to glutathione S-transferase, one to homeodomain protein, and one to a previously described EST (expressed sequence tag) of S. mansoni. This last clone was the most consistently reactive during the screening process with the anti-Sm31/32 antibodies dissociated from the immune complexes. The complete sequence of this clone was obtained and the translation data yielded only one ORF (open reading frame) that code for a protein with 57 amino acids. Based on this amino acid sequence two peptides were chemically synthesized and evaluated separately against a pool of serum samples from schistosomiasis patients and non-schistosomiasis individuals. Both peptides showed strong reactivity only against the positive pool, suggesting that these peptides may be useful as antigens for the diagnosis of schistosomiasis mansoni.