909 resultados para Amperometric measurements
Resumo:
The most popular handgun in Brazil is the single round-barrel caliber 0.38 revolver. In recent years, however, owing to the modernization of police arms and their availability on the legal and illicit markets, pistols have become increasingly popular and currently represent about 20% of police seizures. In a previous paper we presented a novel collection method for gunshot residues (GSR) using a sampling procedure based on ethylenediamine-tetraacetic acid (EDTA) solution as a complexing agent on moistened swabs with subsequent detection using sector field-high resolution-inductively coupled plasma-mass spectrometry (SF-HR-ICP-MS). In the present paper, we discuss the capability of this methodology to identify antimony (Sb), barium (Ba) and lead (Pb) on the hands of volunteers after shot tests with 9 mm and 0.40 in. caliber pistols. Two types of munitions were tested: 9 mm Taurus and clean range. The use of a technique with high sensitivity, such as SF-HR-ICP-MS, permits the identification of low concentrations (less than 1 mu g/L) of metals in firearm residue and constitutes a powerful tool in forensic science. We also discuss the importance of the sampling procedure, including collection from a different body part than the gun hand of the suspect. Comparison of the analytical data obtained allows clear discrimination between samples from the hands of shooters and non-shooters. (C) 2007 Elsevier B.V.. All rights reserved.
Resumo:
Gigahertz conductivity of pressed pellets of ClO4--doped poly( 3-methylthiophene) can be readily obtained from the asymmetry ratio (A / B) of the electron spin resonance line using Dyson's theory. The measurements were performed in three different frequencies, 1.3, 9.4, and 35 GHz. The temperature dependence of the gigahertz conductivity is sensitive to the heating rate, probably due to the ordering of the randomly assembled anions. (C) 1994 Academic Press, Inc.
Resumo:
The electrical characteristics of oxidized poly(thionaphtheneindole) were investigated as a function of ambient relative humidity (r.h.). The current flowing through a pressed pellet of material between two massive gold electrodes plotted against voltage gives a wave-shaped curve with a halfwave potential at V = similar to 3 V. The current recorded at 4 V (plateau of the wave) is a sigmoidal function of r.h, with the inflexion point at similar to 60%. An interpretation of these findings is given, based on the influence of water on the dielectric constant of the material and on acid-base equilibrium between poly(thionaphtheneindole) and water, from which protons are produced. The behaviour of poly (thionaphtheneindole) as the active component of an amperometric humidity sensor is also reported.
Resumo:
According to the current international guidelines concerning environmental problems, it is necessary to evaluate and to know the indoor radon levels, specially since most of the natural radiation dose to man comes from radon gas and its progeny. Several countries have established National Institutions and National Programs for the study of radon and its connection with lung cancer risk and public health. The aim of this work is to present the indoor radon measurements and the detection methods used for different regions of Latin America (LA) in countries such as Argentina, Brazil, Ecuador, Mexico, Peru and Venezuela. This study shows that the passive radon devices based on alpha particle nuclear track methodology (NTM) is one of the more generalized methods in LA for long term indoor radon measurements, CR-39, LR-115 and Makrofol being the more commonly used detector materials. The participating institutions and the radon level measurements in the different countries are presented in this contribution. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Flow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrode
Resumo:
The PB film-modified electrode was used as an amperometric detector for flow injection analysis of ascorbic acid. The modified electrode detector showed good sensitivity, stability and reproducibility. The calibration curve for ascorbic acid was linear over the concentration range from 5.0 x 10(-6) to 1.0 x 10(-3) mol l(-1) with a slope of 19.9 mA mol(-1) per litre and a correlation coefficient of 0.999. The detection limit of this method was 2.49 x 10(-6) mol l(-1). The relative standard deviation of six replicate injections of 2.5 x 10(-4) mol l(-1) ascorbic acid was 2.5%. The results obtained for ascorbic acid determination in pharmaceutical products are in good agreement with those obtained by using the procedure involving the reaction between triiodide and ascorbic acid. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
Background the Test-mate kit determines acetylcholinesterase (AChE, EC 3.1.1.7) and hemoglobin content of a drop of blood, displaying enzyme activities normalized to 25degreesC. Previous models produced inconsistent results at different temperatures. This report focuses on the current model, ChE 400, and two instruments of a previous OP model.Methods AChE activities were determined by the Ellman assay, using the three kits and a 96-well microplate reader Temperatures ranged from 10 to 37degreesC. Fetal bovine serum was the source of AChE.Results Normalized activities decreased below 20degreesC in the ChE model and below 25 C in the OP models. Activities of the same serum sample differed between the three Test-mate kits, ranging from 1.03 to 1.49 mumoles/min/ml. Percent errors were greater than with the microplate reader at all temperatures.Conclusions Neither we nor the manufacturer recommend the current Test-mate model for fieldwork. Nevertheless, there have been field measurements with Test-Mate kits, and we recommend that an enzyme activity standard be run in parallel with their use. (C) 2002 Wiley-Liss, Inc.
Resumo:
We have measured internal friction and frequency as a function of temperature in molybdenum containing oxygen and nitrogen in solid solution. These measurements were performed by a torsion pendulum operating in the temperature range of 300 K to 700 K with oscillation frequency about 1.0 Hz. The results showed the complex relaxation process identifying the stress induced ordering of oxygen and nitrogen atom around the molybdenum atoms of the metallic matrix.
Resumo:
The malate dehydrogenase (MDH) and ascorbate oxidase were immobilized independently, onto silanized controlled porous silica and packed in a tygon tube. The reactors were inserted in the flow system, and the malic acid was determined by measurement of NADH produced by enzymatic reaction. The NADH was reoxidized in a wall jet cell that consisted of spectrographic graphite, Ag/AgCl, KCl(sat), and steel needle as work, reference, and counter electrodes, respectively. The current intensities were measured at 390 mV. The malate calibration curve shows a linear range from 5.0 x 10(-6) to 1.0 x 10(-4) molL(-1), the lifetime was 40 analyses, after that a decrease of 20% on the response is observed. Three different citric juices were analyzed and a good correlation between the proposed method and spectrophotometric commercial kit were obtained.
Resumo:
A pressed pellet of CIO (-)(4) poly (3-methylthiophene) (P3MT) was heated for two hours at 85 degrees C and suddenly dropped in liquid nitrogen. A change was observed around 220 K in the Electron Spin Resonance (ESR) spectra when the sample was slowly cooled from room temperature. ESR line asymmetry parameter (A/B) showed two spatially separated phases. One was identified as a small metallic-like phase. The other phase, the larger one, makes a transition to a semiconducting Charge-Density Wave (CDW) state.
Resumo:
Internal friction and frequency measurements as a function of temperature have been carried out in Nb and Nb-Zr policrystalline samples, using a torsion pendulum in the temperature range between 300K and 700K the heating rate was 1K/min and the pressure was kept better than 5x10(-3) mbar. Metals with bce lattice containing solute atoms dissolved interstitially often show anelastic behaviour due to a process know as stress-induced ordering responsible for the appearance of Snoek peaks. In the Nb sample it has been identified two constituent peaks corresponding to the interstitial-matrix interactions (Nb-O and Nb-N), but for the Nb-Zr samples with interstitial solute concentrations very close to those measured for the unalloyed Nb, it was not observed any mechanical relaxation peaks due to the presence of oxygen and nitrogen in solid solution.
Resumo:
We report here the first direct measurements of changes in protein hydration triggered by a functional binding. This task is achieved by weighing hemoglobin (Hb) and myoglobin films exposed to an atmosphere of 98%, relative humidity during oxygenation. The binding of the first oxygen molecules to Hb tetramer triggers a change in protein conformation, which increases binding affinity to the remaining empty sites giving rise to the appearance of cooperative phenomena. Although crystallographic data have evidenced that this structural change increases the protein water-accessible surface area, isobaric osmotic stress experiments in aqueous cosolutions have shown that water binding is linked to Hb oxygenation. Now we show that the differential hydration between fully oxygenated and fully deoxygenated states of these proteins, determined by weighing protein films with a quartz crystal microbalance, agree with the ones determined by osmotic stress in aqueous cosolutions, from the linkage between protein oxygen affinity and water activity. The agreements prove that the changes in water activity brought about by adding osmolytes to the buffer solution shift biochemical equilibrium in proportion to the number of water molecules associated with the reaction. The concomitant kinetics of oxygen and of water binding to Hb have been also determined. The data show that the binding of water molecules to the extra protein surface exposed on the transition from the low-affinity T to the high-affinity R conformations of hemoglobin is the rate-limiting step of Hb cooperative reaction. This evidences that water binding is a crucial step on the allosteric mechanism regulating cooperative interactions, and suggests the possibility that environmental water activity might be engaged in the kinetic control of some important reactions in vivo.
Resumo:
Throughout late 1998 and early 1999, the International GLONASS Experiment (IGEX) has delivered the first comprehensive inter-continental dual frequency GLONASS data set. This experiment represents the first opportunity to assess how a second global satellite positioning system could complement existing CPS geodetic infrastructure. Based on analysis of a three station network of IGEX stations from Southern Hemisphere IGEX stations, this paper discusses the internal and external precision of long baseline GPS, GLONASS and combined GPS/GLONASS solutions, and the possible contribution of GLONASS to future regional-scale geodetic work.
Resumo:
We report the discovery of 57 new fir laser lines from (CD3OH)-C-13 molecule optically pumped by a waveguide CO2 laser of 300 MHz tunability. For all lines, precise frequency offset measurements between the CO2 line center and the center of the absorbing (CD3OH)-C-13 line were performed using the transferred Lamb-Dip technique. We have also measured directly the frequency of seven FIR laser lines by heterodyning with already known laser lines.We present a complete list of all known laser lines (134) and frequency measurements (24) for this molecule.