956 resultados para Ammonium aminofluoride


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the use of clinoptilolite for removal of ammonium ions present in waters produced at the Campos' Basin. Samples were previously treated in order to remove organic compounds and metals. Experiments were run in fixed- and fluidized-bed systems, at room temperature. The fluidized-bed systems did not remove efficiently the ammonium ion. The best operational conditions were obtained with clinoptilolite particle size in the range 0.30-0.50 mm, under ascendant flow (3 mL min-1), in a fixed-bed system. The best zeolite performance was found when it was pretreated with 0.5 mol L-1 NaOH. Na+ was the most important interfering ion due to its high concentration in the water. Clinoptilolite lost partially its capacity to retain ammonium ions after several regeneration cycles with NaOH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to verify the effects of initial medium moisture content (U), addition of ammonium sulphate (N) and of potassium phosphate (P) in the production of the polygalacturonase through the solid-state fermentation, using cashew apple husk as substrate and Aspergillus niger CCT0916 as transformation agent. We also studied the best extraction conditions of the produced enzyme. The best condition of production was with U of 40%, 1% of N and 0% of P being reached an activity of the poligalacturonase of 10.1 U/g. The best extraction condition is an agitation system with a time of 100 min and a solvent-fermented medium volume ratio of 5 mL/g.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the liquid-liquid extraction of uranium after digestion of colofanite (a fluoroapatite) from Itataia with sulfuric acid. The experiments were run at room temperature in one stage. Among the solutions tested the highest distribution coefficient (D > 60) was found for 40%vol. DEHPA (di(2-ethyl-hexyl)phosphoric acid) + 20% vol. TOPO (trioctylphosphine oxide) in kerosene. Thorium in the raffinate was quantitatively extracted by TOPO (0.1% vol.) in cyclohexane. Uranium stripping and separation from iron was possible using 1.5 mol L-1 ammonium or sodium carbonate (room temperature, one stage). However, pH control is essential for a good separation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the study the adsorption of a cationic surfactant, cetyl trimethyl ammonium bromide (CTAB) in the hydrous niobium phosphate matrix. The matrix was characterized by powder X-ray diffraction (DRX), thermal analysis (TG), differential scanning calorimetry (DSC), scanning electron microscopy (SEM) and surface area measurements (BET). The Langmuir and Freundlich isothermal models were used in the CTAB adsorption study. The adsorption process wasn`t favorable for the NbOPO4.nH2O in both studied models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A commercial corrosion inhibitor used in petroleum production was characterized by means of infrared spectroscopy and energy dispersive spectroscopy (EDS). Predicting the adsorption behavior of corrosion inhibitor onto steel, sandstone and esmectite is the key to improve working conditions. In this study, the adsorption kinetics of inhibitor formulations in HCl 15% or in Mud Acid (HCl 13,5% and ammonium bifluoride) onto steel, sandstone and esmectite was determined by means of spectrophotometry. Kinetic parameters indicated that adsorption of inhibitor in the presence of bifluoride was favored. Moreover, the adsorption constant rate was the largest when the substrate was esmectite.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A binary sampling flow analysis system equipped with gas diffusion cell was developed for NH4+ and/or NH2Cl determination in wastewater and disinfection products samples based on the Berthelot reaction of the NH2Cl diffused through the semi-permeable PTFE membrane. The effect of the analytical conditions related to the reaction and flow parameters were evaluated and N-NH4+ and N-NH2Cl were determined in concentration ranges from 0.17 to 5 mg L-1 and from 0.5 to 14.5 mg L-1, respectively. Limits of detection (3σ) of 50 and 140 µg L-1 for N-NH4+ and N-NH2Cl were calculated, respectively, and RSD of 5 and 2% were calculated for 10 consecutive determinations of N-NH4+ (1 and 3 mg L-1) and N-NH2Cl (3 and 9 mg L-1), respectively with 30 determinations h-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a homemade autosampler for flow injection analysis (FIA), constructed with two step motors from old floppy disk drives (5¼-inch). The autosampler was connected to a computer through the parallel port and the sampling process was controlled by software in Quick Basic. The performance of the system was assessed by the determination of ammonium, based on the gaseous diffusion into a bromocresol purple solution, following the spectrophotometric determination of change in absorbance. The easy and simple construction is the main characteristics of this equipment and analytical results with RSD lower than 1% were obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the combustion process of ammonium dinitramide, ADN, has been modeled in two different situations: decomposition in open environment, with abundant air and decomposition in a rocket motor internal environmental conditions. The profiles of the two processes were achieved, based on molar fractions of the species that compose the products of ADN combustion. The velocity of formation and quantity of species in the open environment was bigger than the ones in the rocket motor environment, showing the effect of the different atmosphere in the reactions kinetics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main goal of this research was the preparation and use of a organophilic smectitic clay able to promoting the adsorption of phenol. In this work was used a natural clay called Chocolate, from Campina Grande - PB (Brazil). The natural clay was treated with a solution of sodium carbonate. After this the sodium clay was treated with quaternary ammonium salt. The adsorptive study was conducted by different values of pH and temperature. The results showed a better performance in adsorptive at pH 7 and temperature 30 ºC, with removal of more than 80% of phenol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rainwater samples (bulk deposition samples) were collected in Pinheiro and Viana. Rainwater pHs were higher than the range usually expected for unpolluted rain (5.0-5.6). The highest values were found in the beginning of the rainy season. High concentrations of ammonium found in the rainwater samples could probably explain the high pHs. Grazing animals and other human activities, combined with soil characteristics and climatic conditions can be the potential factors controlling the rainwater concentrations of ammonium in Baixada Maranhense.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analytical method based on high-performance liquid chromatography with electrochemical detection has been developed and applied to the determination of Solvent blue 14 (SA-14) and Solvent red 24 (SV-24) in fuel samples. The dyes were better separated on C18 column, using a mobile phase composed of acetonitrile and ammonium acetate (90:10, v/v). Detection was carried out at an oxidation potential of +0.85V. The detector response was linear at concentration range of 7.50×10-8 - 1.50×10-6 mol L-1 (r = 0.997) for SA-14 and SV-24, respectively. The method was used to quantify these dyes in fuels samples with satisfactory accuracy and precision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditionally, in the cigarettes industry, the determination of ammonium ion in the mainstream smoke is performed by ion chromatography. This work studies this determination and compares the results of this technique with the use of external and internal standard calibration. A reference cigarette sample presented measurement uncertainty of 2.0 μg/cigarette and 1.5 μg/cigarette, with external and internal standard, respectively. It is observed that the greatest source of uncertainty is the bias correction factor and that it is even more significant when using external standard, confirming thus the importance of internal standardization for this correction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aimed modify chemically the chitosan (QTS) surface to obtain a reticulate chitosan quaternary ammonium salt (SAQQR), and compare this anionic exchanger with an commercial ion exchanger in the extraction of available phosphorus in soils. The results showed that the two exchangers are identical, extracting similar and proportional quantities of available phosphorus in the studied soils, and the anionic exchanger of SAQQR provides a high chemical stability, not affected by the pH difference of soils.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Iron oxide nanoparticles were synthesized in microemulsion systems composed by Triton X-100/hexyl alcohol/cyclohexane/aqueous solution. The nanoparticles were synthesized in microemulsions containing different amounts of ammonium, in order to evaluate the influence of this parameter on the size of the nanoparticles and on the phase transformation after heat treatment. Powder materials were obtained after centrifugation, washing and drying, and they were analyzed as synthesized and after heating at 350, 500 and 1000 °C. It was observed that the higher amount of ammonium induced smaller particles and minor phase transformation, possibly due to a preferential nucleation process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Air samples of fine (PM2,5) and coarse (PM2,5-10) particulate matter were collected in São José dos Campos from February 2004 to February 2005. Average PM10 mass concentrations was 31.2 ± 14.0 μg m-3, half of which belonging to the PM2.5 fraction. Ammonium and SO4(2-) were predominantly found in the fine fraction. Average (NH4)2SO4 concentration was estimated to be about 2.9 μg m-3. Chloride, Na+ and NO3- were mostly associated with PM2,5-10. Chloride deficits with respect to sea-salt Cl/Na ratio were found in both size fractions.