980 resultados para Altman, Ida


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer (PCA) and reference analyzer (RA).Animals-Clinically normal animals (24 cattle, 22 horses, and 22 sheep).Procedures-pH; Pco(2); Po(2); total carbon dioxide concentration; oxygen saturation; base excess; concentrations of HCO(3)(-), Na(+), K(+), and ionized calcium; Hct; and hemoglobin concentration were determined with a PCA. Results were compared with those obtained for the same blood sample with an RA. Bias (mean difference) and variability (95% confidence interval) were determined for all data reported. Data were also subjected to analyses by Deming regression and Pearson correlation.Results-Analysis of Bland-Altman plots revealed good agreement between results obtained with the PCA and those obtained with the RA for pH and total carbon dioxide concentration in cattle, K(+) concentration in horses and sheep, and base excess in horses. Except for Na(+) concentration and Hct in horses and sheep, correlation was good or excellent for most variables reported.Conclusions and Clinical Relevance-Data from blood gas and electrolyte analyses obtained by use of the PCA can be used to evaluate the health status of cattle, horses, and sheep. Furthermore, the handheld PCA device may have a great advantage over the RA device as a result of the ability to analyze blood samples on farms that may be located far from urban centers. (Am J Vet Res 2010;71:515-521)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study compared the performance of fluorescence-based methods, radiographic examination, and International Caries Detection and Assessment System (ICDAS) II on occlusal surfaces. One hundred and nineteen permanent human molars were assessed twice by 2 experienced dentists using the laser fluorescence (LF and LFpen) and fluorescence camera (FC) devices, ICDAS II and bitewing radiographs (BW). After measuring, the teeth were histologically prepared and assessed for caries extension. The sensitivities for dentine caries detection were 0.86 (FC), 0.78 (LFpen), 0.73 (ICDAS II), 0.51 (LF) and 0.34 (BW). The specificities were 0.97 (BW), 0.89 (LF), 0.65 (ICDAS II), 0.63 (FC) and 0.56 (LFpen). BW presented the highest values of likelihood ratio (LR)+ (12.47) and LR- (0.68). Rank correlations with histology were 0.53 (LF), 0.52 (LFpen), 0.41 (FC), 0.59 (ICDAS II) and 0.57 (BW). The area under the ROC curve varied from 0.72 to 0.83. Inter- and intraexaminer intraclass correlation values were respectively 0.90 and 0.85 (LF), 0.93 and 0.87 (LFpen) and 0.85 and 0.76 (FC). The ICDAS II kappa values were 0.51 (interexaminer) and 0.61 (intraexaminer). The BW kappa values were 0.50 (interexaminer) and 0.62 (intraexaminer). The Bland and Altman limits of agreement were 46.0 and 38.2 (LF), 55.6 and 40.0 (LFpen) and 1.12 and 0.80 (FC), for intra- and interexaminer reproducibilities. The posttest probability for dentine caries detection was high for BW and LF. In conclusion, LFpen, FC and ICDAS II presented better sensitivity and LF and BW better specificity. ICDAS II combined with BW showed the best performance and is the best combination for detecting caries on occlusal surfaces. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do presente estudo foi desenvolver um snorquel (SNQ) de baixo custo para mensuração de parâmetros cardiorrespiratórios em natação. Para isso, a máscara do analisador de gases VO2000 (MASC) foi adaptada a um SNQ desenvolvido artesanalmente com espaço morto de 250ml. Oito participantes foram submetidos a dois testes incrementais (TI) em cicloergômetro utilizando a MASC e o SNQ. Os TI foram realizados até a exaustão voluntária e foram compostos por estágios de 3min com carga inicial e incrementos de 35W. em ambas as situações, amostras gasosas foram coletadas em intervalos de 10s para determinação dos volumes de oxigênio (VO2), gás carbônico (VCO2), ventilatório (VE) e mensuração da freqüência cardíaca (FC). A comparação dos parâmetros cardiorrespiratórios (VO2, VE, VCO2 e FC) mensurados com o SNQ e a MASC foi realizada com o teste t de Student para amostras dependentes, enquanto que o teste de correlação de Pearson e a análise gráfica de Bland e Altman foram utilizados para verificar as associações e concordância entre parâmetros. em todos os casos, o nível de significância foi de P < 0,05. A adequação das equações de correção para os valores provenientes do SNQ foi verificada pelos erros sistemáticos (bias), aleatórios (precisão) e acurácia (ac). Não foram observadas diferenças significativas entre os valores de VO2, VCO2 e FC obtidos com a MASC e SNQ. Os valores de VE mensurados com o SNQ foram significativamente superiores aos obtidos com a MASC. No entanto, todos os parâmetros apresentaram elevada concordância e coeficiente de correlação (0,88 a 0,97). Além disso, foram verificados reduzidos valores de bias (VO2 = 0,11L/min; VE = 4,11L/min; VCO2 = 0,54L/min; 8,87bpm), precisão (VO2 = 0,24L/min; VE = 11,02L/ min; VCO2 = 0,18L/min; 7,42bpm) e ac (VO2 = 0,27L/min; VE = 11,76L/min; VCO2 = 0,56L/min; 11,56bpm). Desse modo, pode-se concluir que o SNQ desenvolvido neste estudo possibilita a mensuração válida de parâmetros cardiorrespiratórios em natação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Undergraduate students on the first year of Chemistry Courses are unfamiliar with the representation of acid-base reactions using the ionic equation H+ + OH- → H2O. A chemistry class was proposed about acid-base reactions using theory and experimental evaluation of neutralization heat to discuss the energy involved when water is formed from H+ and OH- ions. The experiment is suggested using different strong acids and strong base pairs. The presentation of the theme within a chemistry class for high school teachers increased the number of individuals that saw the acid-base reaction from this perspective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

FUNDAMENTO: A medida precisa da pressão arterial é fundamental para a investigação científica ou decisão clínica. Nesse sentido, é importante verificar valores fornecidos por equipamentos eletrônicos. OBJETIVO: Validar o monitor Omron HEM 742 de medida de pressão arterial em adolescentes, segundo os critérios sugeridos pela British Hypertension Society. MÉTODOS: Participaram do estudo 150 adolescentes com idades entre 10 e 16 anos. O monitor automático Omron HEM 742 foi conectado em Y com equipamento auscultatório de coluna de mercúrio, e realizaram-se três avaliações simultâneas, calculando-se as diferenças entre os dois equipamentos. Para verificar a relação entre ambos, utilizaram-se o coeficiente de correlação intraclasse e a plotagem de Bland-Altman (concordância). A especificidade e a sensibilidade do aparelho foram determinadas pela curva ROC. RESULTADOS: A comparação entre as medidas acusou uma diferença menor ou igual a 5 mmHg em 67,3% dos valores sistólicos e 69,3% dos valores diastólicos; uma diferença menor ou igual a 10 mmHg ocorreu em 87,3% e 90,6% dos valores sistólicos e diastólicos, respectivamente; e uma diferença menor ou igual a 15 mmHg em 96,6% dos valores sistólicos e 97,3% dos diastólicos. Esses resultados indicam grau A segundo o protocolo da British Hypertension Society. Observou-se ainda elevada concordância nos valores obtidos por meio do monitor automático, e verificou-se que esse equipamento é capaz de identificar a presença ou a ausência da pressão arterial elevada. CONCLUSÃO: O monitor Omron HEM 742 mostrou-se válido para medidas de pressão arterial em adolescentes, conforme os critérios sugeridos pela British Hypertension Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sintering of SnO 2 compacts, obtained through slip casting, was studied by means of dilatometry, Hg porosimetry, scanning electron microscopy, and density measurement (Archimedes method). Sintering is strongly influenced by the green microstructure. Moreover, the sintering mechanisms are not dependent on the slurries' solid content up to 50% of solids in volume. Above this value, agglomerates are formed, leading to differential sintering inside and among the agglomerates. Another important point is the reduction of the temperature of maximum shrinkage rate when compared to tin oxide processed by isostatic pressing. This reduction is more accentuated when ammonium hydroxide is added to the suspension. (C) 2000 Published by Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rheological properties of tin oxide slurries were studied experimentally and theoretically. The deflocculants used were ammonium polyacrilate (PAA) and the copolymer poly(vinyl butyral-co-vinyl alcohol-co-vinyl acetate) (PVB-PVA-PVAc), in water and ethanol, respectively. The amount of deflocculant was optimized for different solid contents by means of viscosity measurements. In spite of the high stability of PVB-dispersed slurries, a high solid concentration was not obtained. On the other hand, a slurry with a 56.4 vol.% of solids was attained when PAA was used. A theoretical study of the adsorption of PAA in its dissociated (basic solution) and non-dissociated (acidic solution) forms on SnO 2 (110) is presented. This analysis was made by means of the PM3 method using a large cluster Sn 15O 28 for the surface model. The calculated adsorption energy is larger for the ionized PAA than for the non-ionized form, indicating that alkaline slurries favor PAA adsorption on the SnO 2 surface. © 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heavy metal oxide (HMO) glasses have received special attention due to their optical, electrical and magnetic properties. The problem with these glasses is their corrosive nature. In this work, three ceramic crucibles (Al 2O 3, SnO 2 and ZrO 2) were tested in the melting of the system 40 PbO-35 BiO 1.5-25 GaO 1.5 (cation-%). After glass melting, crucibles were transversally cut and analyzed by scanning electronic microscopy (SEM), coupled to microanalysis by energy dispersive spectroscopy (EDS). Results indicated that zirconia crucibles presented the highest corrosion, probably due to its smallest grain size. Tin oxide crucibles presented a low corrosion with small penetration of the glass into the crucible. This way, these crucibles are an interesting alternative to melt corrosive glasses in instead of gold or platinum crucibles. It is important to emphasize the lower cost of tin oxide crucibles, compared to gold or platinum ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to their low cost and high resistance to corrosion, ceramic crucibles can be used for the melting of PBG glasses (PbO-BiO 1.5GaO 1.5). These glasses present good window transmission from ultra-violet to infrared, making their use as optical fibres promising. However, their disadvantage is the high reactivity, leading to the corrosion of different crucibles, including gold and platinum ones. In this work, the corrosion of Al 2O 3, SnO 2 and ZrO 2 crucibles after melting at temperatures varying from 850 to 1000°C, was evaluated by Scanning Electronic Microscopy (SEM) in conjunction with microanalysis by EDS. The lead diffusion profile in the crucible material was obtained. Diffusion coefficients were calculated according to the Fick and Fisher theories. Results indicated that the different crucibles presented similar behaviour: in the region near the interface, diffusion occurs in the volumetric way and in regions away from the interface, diffusion occurs through grain boundary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to examine the agreement between the results of body fat (BF and BF%), fat-free mass (FFM) and FFM index (FFMI= FFM/height2) as estimated by skinfold anthropometry (ANT), bioelectrical impedance (BIA) and dual-energy X-ray absorptiometry (DXA) in two groups of men (> or = 50 y), one comprising healthy individuals (n=23) and the other, patients with chronic obstructive pulmonary disease (COPD) (n=24). Comparisons between body composition techniques were done by repeated measures ANOVA; the Bland & Altman procedure was used to analyse agreement. RESULTS AND CONCLUSIONS: 1) comparison between healthy and COPD groups showed significant differences between all studied variables; 2) in the healthy group, values for BF, BF%, FFM and FFMI were not significantly different when BIA or ANT was compared to DXA; however, in COPD, values for BF and BF% were significantly higher and for FFM and FFMI significantly lower when BIA was compared to DXA; in contrast, no differences were shown between values for these variables when ANT was compared with DXA; 3) Bland & Altman test, in both groups, showed no agreement between BIA and DXA and between ANT and DXA; it was also shown that body fat was overestimated and fat free mass underestimated by BIA in relation to DXA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Myosin-Va is a Ca 2+/calmodulin-regulated unconventional myosin involved in the transport of vesicles, membranous organelles, and macromolecular complexes composed of proteins and mRNA. The cellular localization of myosin-Va has been described in great detail in several vertebrate cell types, including neurons, melanocytes, lymphocytes, auditory tissues, and a number of cultured cells. Here, we provide an immunohistochemical view of the tissue distribution of myosin-Va in the major endocrine organs. Myosin-Va is highly expressed in the pineal and pituitary glands and in specific cell populations of other endocrine glands, especially the parafollicular cells of the thyroid, the principal cells of the parathyroid, the islets of Langerhans of the pancreas, the chromaffin cells of the adrenal medulla, and a subpopulation of interstitial testicular cells. Weak to moderate staining has been detected in steroidogenic cells of the adrenal cortex, ovary, and Leydig cells. Myosin-Va has also been localized to non-endocrine cells, such as the germ cells of the seminiferous epithelium and maturing oocytes and in the intercalated ducts of the exocrine pancreas. These data provide the first systematic description of myosin-Va localization in the major endocrine organs of rat. © 2008 Springer-Verlag.