949 resultados para Alignment Layers


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The skin localization of steroids following topical application is largely unknown. We determined the distribution of five steroids in human skin using excised epidermal, dermal, and full-thickness membranes in vitro. There was no significant difference in steroid maximum flux through epidermal and full-thickness membranes, other than significantly lower fluxes for the most polar steroid, aldosterone. Hydrocortisone had the highest dermal diffusivity and dermal penetration, and the accumulation of hydrocortisone and corticosterone was higher than that of the other steroids. Slower penetration and higher accumulation in the viable epidermis of progesterone in full-thickness skin were consistent with dermal penetration limitation effects associated with high lipophilicity. Copyright (c) 2006 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phakometric measurements of corneal and crystalline lens surface alignment are influenced by corneal asymmetry in which the corneal apex does not coincide with the limbal centre. The purpose of this study was to determine the horizontal separation (e) between these corneal landmarks. Measurements were made in 60 normal eyes (30 subjects) using the Orbscan Ilz corneal analysis workstation. Our results show that both corneal landmarks typically coincide, so that e = 0, but that inter-subject variations of about ±1 mm can be expected (so that the corneal apex may fall nasal or temporal to the visual axis). This suggests that no correction for corneal asymmetry is required when estimating average amounts of ocular alignment from samples of eyes but that the measurement of e is strongly recommended for measurements in individual eyes. © 2004 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements (autokeratometry, A-scan ultrasonography and video ophthalmophakometry) of ocular surface radii, axial separations and alignment were made in the horizontal meridian of nine emmetropes (aged 20-38 years) with relaxed (cycloplegia) and active accommodation (mean ± 95% confidence interval: 3.7 ± 1.1 D). The anterior chamber depth (-1.5 ± 0.3 D) and both crystalline lens surfaces (front 3.1 ± 0.8 D; rear 2.1 ± 0.6 D) contributed to dioptric vergence changes that accompany accommodation. Accommodation did not alter ocular surface alignment. Ocular misalignment in relaxed eyes is mainly because of eye rotation (5.7 ± 1.6° temporally) with small amounts of lens tilt (0.2 ± 0.8° temporally) and decentration (0.1 ± 0.1 mm nasally) but these results must be viewed with caution as we did not account for corneal asymmetry. Comparison of calculated and empirically derived coefficients (upon which ocular surface alignment calculations depend) revealed that negligible inherent errors arose from neglect of ocular surface asphericity, lens gradient refractive index properties, surface astigmatism, effects of pupil size and centration, assumed eye rotation axis position and use of linear equations for analysing Purkinje image shifts. © 2004 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ophthalmophakometric measurements of ocular surface radius of curvature and alignment were evaluated on physical model eyes encompassing a wide range of human ocular dimensions. The results indicated that defocus errors arising from imperfections in the ophthalmophakometer camera telecentricity and light source collimation were smaller than experimental errors. Reasonable estimates emerged for anterior lens surface radius of curvature (accuracy: 0.02–0.10 mm; precision 0.05–0.09 mm), posterior lens surface radius of curvature (accuracy: 0.10–0.55 mm; precision 0.06–0.20 mm), eye rotation (accuracy: 0.00–0.32°; precision 0.06–0.25°), lens tilt (accuracy: 0.00–0.33°; precision 0.05–0.98°) and lens decentration (accuracy: 0.00–0.07 mm; precision 0.00–0.07 mm).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a non-invasive phakometric method for determining corneal axis rotation relative to the visual axis (β) together with crystalline lens axis tilt (α) and decentration (d) relative to the corneal axis. This does not require corneal contact A-scan ultrasonography for the measurement of intraocular surface separations. Theoretical inherent errors of the method, evaluated by ray tracing through schematic eyes incorporating the full range of human ocular component variations, were found to be larger than the measurement errors (β < 0.67°, α < 0.72° and d < 0.08 mm) observed in nine human eyes with known ocular component dimensions. Intersubject variations (mean ± S.D.: β = 6.2 ± 3.4° temporal, α = 0.2 ± 1.8° temporal and d = 0.1 ± 0.1 mm temporal) and repeatability (1.96 × S.D. of difference between repeat readings: β ± 2.0°, α ± 1.8° and d ± 0.2 mm) were studied by measuring the left eyes of 45 subjects (aged 18-42 years, 29 females and 16 males, 15 Caucasians, 29 Indian Asians, one African, refractive error range -7.25 to +1.25 D mean spherical equivalent) on two occasions. © 2005 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-linear solutions and studies of their stability are presented for flows in a homogeneously heated fluid layer under the influence of a constant pressure gradient or when the mass flux across any lateral cross-section of the channel is required to vanish. The critical Grashof number is determined by a linear stability analysis of the basic state which depends only on the z-coordinate perpendicular to the boundary. Bifurcating longitudinal rolls as well as secondary solutions depending on the streamwise x-coordinate are investigated and their amplitudes are determined as functions of the supercritical Grashof number for various Prandtl numbers and angles of inclination of the layer. Solutions that emerge from a Hopf bifurcation assume the form of propagating waves and can thus be considered as steady flows relative to an appropriately moving frame of reference. The stability of these solutions with respect to three-dimensional disturbances is also analyzed in order to identify possible bifurcation points for evolving tertiary flows.