946 resultados para Ablation of aluminum
Resumo:
The expansion dynamics of the ablation plume generated by KrF laser irradiation of hydroxyapatite targets in a 0.1 mbar water atmosphere has been studied by fast intensified charge coupled device imaging with the aid of optical bandpass filters. The aim of the filters is to isolate the emission of a single species, which allows separate analysis of its expansion. Images obtained without a filter revealed two emissive components in the plume, which expand at different velocities for delay times of up to 1.1 ¿s. The dynamics of the first component is similar to that of a spherical shock wave, whereas the second component, smaller than the first, expands at constant velocity. Images obtained through a 520 nm filter show that the luminous intensity distribution and evolution of emissive atomic calcium is almost identical to those of the first component of the total emission and that there is no contribution from this species to the emission from the second component of the plume. The analysis through a 780 nm filter reveals that atomic oxygen partially diffuses into the water atmosphere and that there is a contribution from this species to the emission from the second component. The last species studied here, calcium oxide, was analyzed by means of a 600 nm filter. The images revealed an intensity pattern more complex than those from the atomic species. Calcium oxide also contributes to the emission from the second component. Finally, all the experiments were repeated in a Ne atmosphere. Comparison of the images revealed chemical reactions between the first component of the plume and the water atmosphere.
Resumo:
Interaction models of atomic Al with Si4H9, Si4H7, and Si6H9 clusters have been studied to simulate Al chemisorption on the Si(111) surface in the atop, fourfold atop, and open sites. Calculations were carried out using nonempirical pseudopotentials in the framework of the ab initio Hartree-Fock procedure. Equilibrium bond distances, binding energies for adsorption, and vibrational frequencies of the adatoms are calculated. Several basis sets were used in order to show the importance of polarization effects, especially in the binding energies. Final results show the importance of considering adatom-induced relaxation effects to specify the order of energy stabilities for the three different sites, the fourfold atop site being the preferred one, in agreement with experimental findings.
Resumo:
PURPOSE: To assess the usefulness of combining hyperthermia with a DNA repair inhibitor (double-strand break bait [Dbait]) and its potential application to radiofrequency ablation (RFA) in a preclinical model of human colorectal cancer. MATERIALS AND METHODS: The local ethics committee of animal experimentation approved all investigations. First, the relevance was assessed by studying the survival of four human colorectal adenocarcinoma cell cultures after 1 hour of hyperthermia at 41°C or 43°C with or without Dbait. Human colon adenocarcinoma cells (HT-29) were grafted subcutaneously into nude mice (n = 111). When tumors reached approximately 500 mm(3), mice were treated with Dbait alone (n = 20), sublethal RFA (n = 21), three different Dbait schemes and sublethal RFA (n = 52), or a sham treatment (n = 18). RFA was performed to ablate the tumor center alone. To elucidate antitumor mechanisms, 39 mice were sacrificed for blinded pathologic analysis, including assessment of DNA damage, cell proliferation, and tumor necrosis. Others were monitored for tumor growth and survival. Analyses of variance and log-rank tests were used to evaluate differences. RESULTS: When associated with mild hyperthermia, Dbait induced cytotoxicity in all tested colon cancer cell lines. Sublethal RFA or Dbait treatment alone moderately improved survival (median, 40 days vs 28 days for control; P = .0005) but combination treatment significantly improved survival (median, 84 days vs 40 days for RFA alone, P = .0004), with approximately half of the animals showing complete tumor responses. Pathologic studies showed that the Dbait and RFA combination strongly enhances DNA damage and coagulation areas in tumors. CONCLUSION: Combining Dbait with RFA sensitizes the tumor periphery to mild hyperthermia and increases RFA antitumor efficacy.
Resumo:
U-Pb dating of zircons by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is a widely used analytical technique in Earth Sciences. For U-Pb ages below 1 billion years (1 Ga), Pb-206/U-238 dates are usually used, showing the least bias by external parameters such as the presence of initial lead and its isotopic composition in the analysed mineral. Precision and accuracy of the Pb/U ratio are thus of highest importance in LA-ICPMS geochronology. We consider the evaluation of the statistical distribution of the sweep intensities based on goodness-of-fit tests in order to find a model probability distribution fitting the data to apply an appropriate formulation for the standard deviation. We then discuss three main methods to calculate the Pb/U intensity ratio and its uncertainty in the LA-ICPMS: (1) ratio-of-the-mean intensities method, (2) mean-of-the-intensity-ratios method and (3) intercept method. These methods apply different functions to the same raw intensity vs. time data to calculate the mean Pb/U intensity ratio. Thus, the calculated intensity ratio and its uncertainty depend on the method applied. We demonstrate that the accuracy and, conditionally, the precision of the ratio-of-the-mean intensities method are invariant to the intensity fluctuations and averaging related to the dwell time selection and off-line data transformation (averaging of several sweeps); we present a statistical approach how to calculate the uncertainty of this method for transient signals. We also show that the accuracy of methods (2) and (3) is influenced by the intensity fluctuations and averaging, and the extent of this influence can amount to tens of percentage points; we show that the uncertainty of these methods also depends on how the signal is averaged. Each of the above methods imposes requirements to the instrumentation. The ratio-of-the-mean intensities method is sufficiently accurate provided the laser induced fractionation between the beginning and the end of the signal is kept low and linear. We show, based on a comprehensive series of analyses with different ablation pit sizes, energy densities and repetition rates for a 193 nm ns-ablation system that such a fractionation behaviour requires using a low ablation speed (low energy density and low repetition rate). Overall, we conclude that the ratio-of-the-mean intensities method combined with low sampling rates is the most mathematically accurate among the existing data treatment methods for U-Pb zircon dating by sensitive sector field ICPMS.
A biophysical model of atrial fibrillation ablation: what can a surgeon learn from a computer model?
Resumo:
AIMS: Surgical ablation procedures for treating atrial fibrillation have been shown to be highly successful. However, the ideal ablation pattern still remains to be determined. This article reports on a systematic study of the effectiveness of the performance of different ablation line patterns. METHODS AND RESULTS: This study of ablation line patterns was performed in a biophysical model of human atria by combining basic lines: (i) in the right atrium: isthmus line, line between vena cavae and appendage line and (ii) in the left atrium: several versions of pulmonary vein isolation, connection of pulmonary veins, isthmus line, and appendage line. Success rates and the presence of residual atrial flutter were documented. Basic patterns yielded conversion rates of only 10-25 and 10-55% in the right and the left atria, respectively. The best result for pulmonary vein isolation was obtained when a single closed line encompassed all veins (55%). Combination of lines in the right/left atrium only led to a success rate of 65/80%. Higher rates, up to 90-100%, could be obtained if right and left lines were combined. The inclusion of a left isthmus line was found to be essential for avoiding uncommon left atrial flutter. CONCLUSION: Some patterns studied achieved a high conversion rate, although using a smaller number of lines than those of the Maze III procedure. The biophysical atrial model is shown to be effective in the search for promising alternative ablation strategies.
Resumo:
Purpose: Most of the patients with advanced colorectal cancer will develop liver metastasis, even after primary tumor resection. Although surgical resection remains the gold standard treatment of hepatic metastases, only few patients are eligible to curative resection. Radiofrequency ablation (RFA) is the most common curative alternative. Dbait are new molecules that inhibit DNA double-strand breaks repair. In vitro, Dbait has shown to increase cell death after hyperthermia. Here, we have assessed the combination of Dbait and RFA in the treatment of human colorectal cancer model xenografted in nude mice.Materials: 98 mice were flank-grafted with HT29 (human colon adenocarcinoma). When tumor reached 500 mm3, mice were sham treated (n=19), treated by Dbait via local injections (n=20), treated by RFA using an incomplete ablation scheme (n=20) or treated by combination of Dbait and RFA (n=39 separated in two Dbait regimens). After RFA, 39 mice were sacrificed for blinded pathological study, and 59 others were followed for survival analysis.Results: Mice treated by RFA-Dbait had significantly longer survival as compared to RFA alone (median survival: 56 vs 39 days, p<0.05) while RFA improved survival as compared to controls (median survival: 39 vs 28 days, p<0.05). Pathological studies of tumor slice have demonstrated significant decrease of tumor area and cancer cell viability in the RFA-Dbait group.Conclusions: While the implication of DNA repair activity in heat sensitivity remains unclear, our results show that the addition of Dbait to RFA enhances the antitumor response in this model and provide an experimental basis for the use of Dbait as an additional therapy to RFA.
Resumo:
BACKGROUND: Radiofrequency (RF) ablation is used to obtain local control of unresectable tumors in liver, kidney, prostate, and other organs. Accurate data on expected size and geometry of coagulation zones are essential for physicians to prevent collateral damage and local tumor recurrence. The aim of this study was to develop a standardized terminology to describe the size and geometry of these zones for experimental and clinical RF. METHODS: In a first step, the essential geometric parameters to accurately describe the coagulation zones and the spatial relationship between the coagulation zones and the electrodes were defined. In a second step, standard terms were assigned to each parameter. RESULTS: The proposed terms for single-electrode RF ablation include axial diameter, front margin, coagulation center, maximal and minimal radius, maximal and minimal transverse diameter, ellipticity index, and regularity index. In addition a subjective description of the general shape and regularity is recommended. CONCLUSIONS: Adoption of the proposed standardized description method may help to fill in the many gaps in our current knowledge of the size and geometry of RF coagulation zones.
Resumo:
The use of high-strength aluminium alloys as material for injection molding tools to produce small and medium batches of plastic products as well as prototyping molds is becoming of increasing demand by the tooling industry. These alloys are replacing the traditional use of steel in the cases above because they offer many advantages such as very high thermal conductivity associated with good corrosion and wear resistance presenting good machinability in milling and electrical discharge machining operations. Unfortunately there is little technological knowledge on the Electrical Discharge Machining (EDM) of high-strength aluminium alloys, especially about the AMP 8000 alloy. The duty factor, which means the ratio between pulse duration and pulse cycle time exerts an important role on the performance of EDM. This work has carried out an experimental study on the variation of the duty factor in order to analyze its influence on material removal rate and volumetric relative wear under roughing conditions of EDM process. The results showed that high values of duty factor are possible to be applied without bringing instability into the EDM process and with improvement of material removal rate and volumetric relative wear.
Resumo:
Aluminum (Al3+) intoxication is thought to play a major role in the development of Alzheimer's disease and in certain pathologic manifestations arising from long-term hemodialysis. Although the metal does not present redox capacity, it can stimulate tissue lipid peroxidation in animal models. Furthermore, in vitro studies have revealed that the fluoroaluminate complex induces diacylglycerol formation, 43-kDa protein phosphorylation and aggregation. Based on these observations, we postulated that Al3+-induced blood platelet aggregation was mediated by lipid peroxidation. Using chemiluminescence (CL) of luminol as an index of total lipid peroxidation capacity, we established a correlation between lipid peroxidation capacity and platelet aggregation. Al3+ (20-100 µM) stimulated CL production by human blood platelets as well as their aggregation. Incubation of the platelets with the antioxidants nor-dihydroguaiaretic acid (NDGA) (100 µM) and n-propyl gallate (NPG) (100 µM), inhibitors of the lipoxygenase pathway, completely prevented CL and platelet aggregation. Acetyl salicylic acid (ASA) (100 µM), an inhibitor of the cyclooxygenase pathway, was a weaker inhibitor of both events. These findings suggest that Al3+ stimulates lipid peroxidation and the lipoxygenase pathway in human blood platelets thereby causing their aggregation
Resumo:
Aluminum (Al3+) overload is frequently associated with lipid peroxidation and neurological disorders. Aluminum accumulation is also reported to be related to renal impairment, anemia and other clinical complications in hemodialysis patients. The aim of the present study was to determine the degree of lipid peroxidation, platelet aggregation and serum aluminum in patients receiving regular hemodialytic treatment. The level of plasma lipid peroxidation was evaluated on the basis of thiobarbituric acid reactive substances (TBARS). Mean platelet peroxidation in patients undergoing hemodialysis was significantly higher than in normal controls (2.7 ± 0.03 vs 1.8 ± 0.06 nmol/l, P<0.05). Platelet aggregation and serum aluminum levels were determined by a turbidimetric method and atomic absorption spectrophotometry, respectively. Serum aluminum was significantly higher in patients than in normal controls (44.5 ± 29 vs 10.8 ± 2.5 µg/l, P<0.05). Human blood platelets were stimulated with collagen (2.2 µg/ml), adenosine diphosphate (6 µM) and epinephrine (6 µM) and showed reduced function with the three agonists utilized. No correlation between aluminum levels and platelet aggregation or between aluminum and peroxidation was observed in hemodialyzed patients.
Resumo:
This study determined the effects of gallium-aluminum-arsenide laser (GaAlAs), gallium-arsenide laser (GaAs) and Dersani® healing ointment on skin wounds in Wistar rats. The parameters analyzed were: type I and III collagen fiber concentrations as well as the rate of wound closure. Five wounds, 12 mm in diameter, were made on the animals’ backs. The depth of the surgical incision was controlled by removing the epithelial tissue until the dorsal muscular fascia was exposed. The animals were anesthetized with ketamine and xylazine via intraperitoneal injection. The rats were randomly divided into five groups of 6 animals each, according to the treatment received. Group 1 (L4): GaAs laser (4 J/cm²); group 2 (L30): GaAlAs laser (30 J/cm²); group 3 (L60): GaAlAs laser (60 J/cm²); group 4 (D): Dersani® ointment; group 5 (control): 0.9% saline. The applications were made daily over a period of 20 days. Tissue fragments were stained with picrosirius to distinguish type I collagen from type III collagen. The collagen fibers were photo-documented and analyzed using the Quantum software based on the primary color spectrum (red, yellow and blue). Significant results for wound closing rate were obtained for group 1 (L4), 7.37 mm/day. The highest concentration of type III collagen fibers was observed in group 2 (L30; 37.80 ± 7.10%), which differed from control (29.86 ± 5.15%) on the 20th day of treatment. The type I collagen fibers of group 1 (L4; 2.67 ± 2.23%) and group 2 (L30; 2.87 ± 2.40%) differed significantly from control (1.77 ± 2.97%) on the 20th day of the experiment.
Resumo:
Contact force (CF) sensing technology allows real-time monitoring during catheter ablation for atrial fibrillation (AF). However, the effect of CF sensing technology on procedural parameters and clinical outcomes still needs clarification. Because of the inconsistent results thus far in this area, we performed a meta-analysis to determine whether CF sensing technology can improve procedural parameters and clinical outcomes for the treatment of AF. Studies examining the benefits of CF sensing technology were identified in English-language articles by searching the MEDLINE, Web of Science, and Cochrane Library databases (inception to May 2015). Ten randomized, controlled trials involving 1834 patients (1263 males, 571 females) were included in the meta-analysis (681 in the CF group, 1153 in the control group). Overall, the ablation time was significantly decreased by 7.34 min (95%CI=-12.21 to -2.46; P=0.003, Z test) in the CF group compared with the control group. CF sensing technology was associated with significantly improved freedom from AF after 12 months (OR=1.55, 95%CI=1.20 to 1.99; P=0.0007) and complications were significantly lower in the CF group than in the control group (OR=0.50, 95%CI=0.29 to 0.87; P=0.01). However, fluoroscopy time analysis showed no significantly decreased trend associated with CF-guided catheter ablation (weighted mean difference: -2.59; 95%CI=-9.06 to 3.88; P=0.43). The present meta-analysis shows improvement in ablation time and freedom from AF after 12 months in AF patients treated with CF-guided catheter ablation. However, CF-guided catheter ablation does not decrease fluoroscopy time.
Resumo:
The objective of this study was to evaluate the performance of seeds of two cultivars of lowland rice (Oryza sativa L.), coated with dolomitic limestone and aluminum silicate. It was used a completely randomized experimental design, with the treatments arranged in a 4 X 2 factorial scheme [4 treatments: dolomitic limestone; dolomitic limestone + aluminum silicate; aluminum silicate, at the dosages of 50 g/100 kg of seeds; and control (without the products) X 2 cultivars: IRGA424 and IRGA 422 CL], totaling eight treatments with four replications each. The variables analyzed were: fresh and dry weights of aerial biomass; plant height; leaf area at 10, 20, and 30 days after emergence (DAE). The physiological quality of seeds was also assessed using tests of: seed emergence; first count of germination; emergence speed index; and field emergence. It was concluded that the coating of rice seeds with dolomitic limestone and aluminum silicate does not affect seed germination and field seedling emergence. Aluminum silicate used via seed coating on cultivar IRGA 424 promoted greater leaf area, after 20 DAE. The dolomitic limestone and the aluminum silicate used via seed coating generated plants with larger dry biomass, after 20 DAE, for the cultivar IRGA 422 CL.
Resumo:
Transparent conducting oxides (TCO’s) have been known and used for technologically important applications for more than 50 years. The oxide materials such as In2O3, SnO2 and impurity doped SnO2: Sb, SnO2: F and In2O3: Sn (indium tin oxide) were primarily used as TCO’s. Indium based oxides had been widely used as TCO’s for the past few decades. But the current increase in the cost of indium and scarcity of this material created the difficulty in obtaining low cost TCO’s. Hence the search for alternative TCO material has been a topic of active research for the last few decades. This resulted in the development of various binary and ternary compounds. But the advantages of using binary oxides are the easiness to control the composition and deposition parameters. ZnO has been identified as the one of the promising candidate for transparent electronic applications owing to its exciting optoelectronic properties. Some optoelectronics applications of ZnO overlap with that of GaN, another wide band gap semiconductor which is widely used for the production of green, blue-violet and white light emitting devices. However ZnO has some advantages over GaN among which are the availability of fairly high quality ZnO bulk single crystals and large excitonic binding energy. ZnO also has much simpler crystal-growth technology, resulting in a potentially lower cost for ZnO based devices. Most of the TCO’s are n-type semiconductors and are utilized as transparent electrodes in variety of commercial applications such as photovoltaics, electrochromic windows, flat panel displays. TCO’s provide a great potential for realizing diverse range of active functions, novel functions can be integrated into the materials according to the requirement. However the application of TCO’s has been restricted to transparent electrodes, ii notwithstanding the fact that TCO’s are n-type semiconductors. The basic reason is the lack of p-type TCO, many of the active functions in semiconductor originate from the nature of pn-junction. In 1997, H. Kawazoe et al reported the CuAlO2 as the first p-type TCO along with the chemical design concept for the exploration of other p-type TCO’s. This has led to the fabrication of all transparent diode and transistors. Fabrication of nanostructures of TCO has been a focus of an ever-increasing number of researchers world wide, mainly due to their unique optical and electronic properties which makes them ideal for a wide spectrum of applications ranging from flexible displays, quantum well lasers to in vivo biological imaging and therapeutic agents. ZnO is a highly multifunctional material system with highly promising application potential for UV light emitting diodes, diode lasers, sensors, etc. ZnO nanocrystals and nanorods doped with transition metal impurities have also attracted great interest, recently, for their spin-electronic applications This thesis summarizes the results on the growth and characterization of ZnO based diodes and nanostructures by pulsed laser ablation. Various ZnO based heterojunction diodes have been fabricated using pulsed laser deposition (PLD) and their electrical characteristics were interpreted using existing models. Pulsed laser ablation has been employed to fabricate ZnO quantum dots, ZnO nanorods and ZnMgO/ZnO multiple quantum well structures with the aim of studying the luminescent properties.
Resumo:
The acoustic signals generated in solids due to interaction with pulsed laser beam is used to determine the ablation threshold of bulk polymer samples of teflon (polytetrafluoroethylene) and nylon under the irradiation from a Q-switched Nd:YAG laser at 1.06µm wavelength. A suitably designed piezoelectric transducer is employed for the detection of photoacoustic (PA) signals generated in this process. It has been observed that an abrupt increase in the amplitude of the PA signal occurs at the ablation threshold. Also there exist distinct values for the threshold corresponding to different mechanisms operative in producing damages like surface morphology, bond breaking and melting processes at different laser energy densities.