960 resultados para AUTLER-TOWNES MICROSCOPY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

GaN, InP and GaAs nanowires were investigated for piezoelectric response. Nanowires and structures based on them can find wide applications in areas purposes such as nanogenarators, nanodrives, Solar cells and other perspective areas. Experemental measurements were carried out on AFM Bruker multimode 8 and data was handled with Nanoscope software. AFM techniques permitted not only to visualize the surface topography, but also to show distribution of piezoresponse and allowed to calculate its properties. The calculated values are in the same range as published by other authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iron-chromium alloys are used as a model to study the microstructural evolution of defects in irradiated structural steel components of a nuclear reactor. We examine the effects of temperature and chromium concentration on the defect evolution and segregation behavior in the early stages of damage. In situ irradiations are conducted in a transmission electron microscope (TEM) at 300°C and 450°C with 150keV iron ions in single crystal Fe14Cr and Fe19Cr bicrystal to doses of 2E15 ions/cm^2. The microstructures resulting from annealing and irradiation of the alloy are characterized by analysis of TEM micrographs and diffraction patterns and compared with those of irradiated pure iron. We found the irradiation temperature to have little effect on the microstructural development. We also found that the presence of chromium in the sample leads to defect populations with small average loop size and no extended or nested loop structures, in contrast to the populations of large extended loops seen in irradiated pure iron. A very weak dependence was found on the specific chromium content of the alloy. Chromium was shown to suppress defect growth by inhibiting defect mobility in the alloy. While defects in pure iron are highly mobile and able to grow, those in the FeCr alloys remained small and relatively motionless due to the pinning effect of the chromium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis reports on the development of quantitative measurement using micromachined scanning thermal microscopy (SThM) probes. These thermal probes employ a resistive element at their end, which can be used in passive or active modes. With the help of a review of SThM, the current issues and potentials associated with this technique are revealed. As a consequence of this understanding, several experimental and theoretical methods are discussed, which expand our understanding of these probes. The whole thesis can be summarized into three parts, one focusing on the thermal probe, one on probe-sample thermal interactions, and the third on heat transfer within the sample. In the first part, a series of experiments are demonstrated, aimed at characterizing the probe in its electrical and thermal properties, benefiting advanced probe design, and laying a fundamental base for quantifying the temperature of the probe. The second part focuses on two artifacts observed during the thermal scans – one induced by topography and the other by air conduction. Correspondingly, two devices, probing these artifacts, are developed. A topography-free sample, utilizing a pattern transfer technique, minimises topography-related artifacts that limited the reliability of SThM data; a controlled temperature ‘Johnson noise device’, with multiple-heater design, offers a uniform, accurate, temperature distribution. Analyzing results of scan from these samples provides data for studying the thermal interactions within the probe and the tip-sample interface. In the final part, the observation is presented that quantification of measurements depends not only on an accurate measurement tool, but also on a deep understanding of the heat transfer within the sample resulting from the nanoscopic contact. It is believed that work in this thesis contributes to SThM gaining wider application in the scientific community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, the anodic oxide films of Al, Al-Cu 4.5% and Al-Si 6.5% alloys are formed using direct and pulse current. In the case of Al-Cu and Al-Si alloys, the electrolyte used contains sulfuric acid and oxalic acid, meanwhile for Al the electrolyte contains sulfuric acid only. Al-Cu alloy was submitted to a heat treatment in order to decrease the effect of inter metallic phase theta upon the anodic film structure. Fractured samples were observed using a field emission gun scanning electron microscope JSM-6330F at (LME)/Brazilian Synchrotron Light Laboratory (LNLS), Campinas, SP, Brazil. The oxide film images enable evaluation of the pore size and form with a resolution similar to the transmission electron microscope (TEM) resolution. It is also observed that the anodizing process using pulse current produces an irregular structure of pore walls, and by direct cur-rent it is produced a rectilinear pore wall. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Tuberculosis (TB) is caused by Mycobacterium tuberculosis and is transmitted mainly through aerosolization of infected sputum which puts laboratory workers at risk in spite of the laboratory workers’ risk of infection being at 3 to 9 times higher than the general public. Laboratory safety should therefore be prioritized and optimized to provide sufficient safety to laboratory workers. Objective To assess the safety for the laboratory workers in TB primary microscopy centres in Blantyre urban. Methodology TB primary microscopy centers in Blantyre urban were assessed in aspects of equipment availability, facility layout, and work practice, using a standardized WHO/AFRO ISO 15189 checklist for the developing countries which sets the minimum safety score at ≥80%. Each center was graded according to the score it earned upon assessment. Results Only one (1) microscopy center out nine (9) reached the minimum safety requirement. Four (4) centers were awarded 1 star level, four (4) centers were awarded 2 star level and only one (1) center was awarded 3 star level. Conclusion In Blantyre urban, 89% of the Tuberculosis microscopy centers are failing to provide the minimum safety to the laboratory workers. Government and other stake holders should be committed in addressing the safety challenges of TB microscopy centres in the country to ensure safety for the laboratory workers. Recommendations It is recommended that the study be conducted at the regional or national level for both public and private laboratories in order to have a general picture of safety in Tb microscopy centres possibly across the country.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The atomic-level structure and chemistry of materials ultimately dictate their observed macroscopic properties and behavior. As such, an intimate understanding of these characteristics allows for better materials engineering and improvements in the resulting devices. In our work, two material systems were investigated using advanced electron and ion microscopy techniques, relating the measured nanoscale traits to overall device performance. First, transmission electron microscopy and electron energy loss spectroscopy (TEM-EELS) were used to analyze interfacial states at the semiconductor/oxide interface in wide bandgap SiC microelectronics. This interface contains defects that significantly diminish SiC device performance, and their fundamental nature remains generally unresolved. The impacts of various microfabrication techniques were explored, examining both current commercial and next-generation processing strategies. In further investigations, machine learning techniques were applied to the EELS data, revealing previously hidden Si, C, and O bonding states at the interface, which help explain the origins of mobility enhancement in SiC devices. Finally, the impacts of SiC bias temperature stressing on the interfacial region were explored. In the second system, focused ion beam/scanning electron microscopy (FIB/SEM) was used to reconstruct 3D models of solid oxide fuel cell (SOFC) cathodes. Since the specific degradation mechanisms of SOFC cathodes are poorly understood, FIB/SEM and TEM were used to analyze and quantify changes in the microstructure during performance degradation. Novel strategies for microstructure calculation from FIB-nanotomography data were developed and applied to LSM-YSZ and LSCF-GDC composite cathodes, aged with environmental contaminants to promote degradation. In LSM-YSZ, migration of both La and Mn cations to the grain boundaries of YSZ was observed using TEM-EELS. Few substantial changes however, were observed in the overall microstructure of the cells, correlating with a lack of performance degradation induced by the H2O. Using similar strategies, a series of LSCF-GDC cathodes were analyzed, aged in H2O, CO2, and Cr-vapor environments. FIB/SEM observation revealed considerable formation of secondary phases within these cathodes, and quantifiable modifications of the microstructure. In particular, Cr-poisoning was observed to cause substantial byproduct formation, which was correlated with drastic reductions in cell performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atomic force microscopy (AFM) allows the analysis of individual polymers at nanostructural level with a minimal sample preparation. This technique has been used to analyse the pectin disassembly process during the ripening and postharvest storage of several fleshy fruits. In general, pectins analysed by AFM are usually visualized as isolated chains, unbranched or with a low number of branchs and, occasionally, as large aggregates. However, the exact nature of these structures is unknown. It has been suggested that pectin aggregates represent a mixture of rhamnonogalacturonan I and homogalacturonan, while isolated chains and their branches are mainly composed by polygalacturonic acid. In order to gain insight into the nature of these structures, sodium carbonate soluble pectins from ripe strawberry (Fragaria x ananassa, Duch.) fruits were subjected to enzymatic digestion with endo-Polygalacturonase M2 from Aspergillus aculeatus, and the samples visualized by AFM at different time intervals. Pectins isolated from control, non-transformed plants, and two transgenic genotypes with low level of expression of ripening-induced pectinase genes encoding a polygalacturonase (APG) or a pectate lyase (APEL) were also included in this study. Before digestion, isolated pectin chains from control were shorter than those from transgenic fruits, showing number-average (LN) contour length values of 73.2 nm vs. 95.9 nm and 91.4 nm in APG and APEL, respectively. The percentage of branched polymers was significantly higher in APG polyuronides than in the remaining genotypes, 33% in APG vs. 6% in control and APEL. As a result of the endo-PG treatment, a gradual decrease in the main backbone length of isolated chains was observed in the three samples. The minimum LN value was reached after 8 h of digestion, being similar in the three genotypes, 22 nm. By contrast, the branches were not visible after 1.5-2 h of digestion. LN values were plotted against digestion time and the data fitted to a first-order exponential decay curve, obtaining R2 values higher than 0.9. The half digestion time calculated with these equations were similar for control and APG pectins, 1.7 h, but significantly higher in APEL, 2.5 h, indicating that these polymer chains were more resistant to endo-PG digestion. Regarding the pectin aggregates, their volumes were estimated and used to calculate LN molecular weights. Before digestion, control and APEL samples showed complexes of similar molecular weights, 1722 kDa, and slightly higher than those observed in APG samples. After endo-PG digestion, size of complexes diminished significantly, reaching similar values in the three pectin samples, around 650 kDa. These results suggest that isolated polymer chains visualized by AFM are formed by a HG domain linked to a shorter polymer resistant to endo-PG digestion, maybe xylogalacturonan or RG-I. The silencing of the pectate lyase gene slightly modified the structure and/or chemical composition of polymer chains making these polyuronides more resistant to enzymatic degradation. Similarly, polygalacturonic acid is one of the main component of the aggregates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cell culture, cell structures suffer strong impact due to centrifugation during processing for electron microscope observation. In order to minimise this effect, a new protocol was successfully developed. Using conventional reagents and equipments, it took over one week, but cell compression was reduced to none or the lowest deformation possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We apply wide-field interferometric microscopy techniques to acquire quantitative phase profiles of ventricular cardiomyocytes in vitro during their rapid contraction with high temporal and spatial resolution. The whole-cell phase profiles are analyzed to yield valuable quantitative parameters characterizing the cell dynamics, without the need to decouple thickness from refractive index differences. Our experimental results verify that these new parameters can be used with wide field interferometric microscopy to discriminate the modulation of cardiomyocyte contraction dynamics due to temperature variation. To demonstrate the necessity of the proposed numerical analysis for cardiomyocytes, we present confocal dual-fluorescence-channel microscopy results which show that the rapid motion of the cell organelles during contraction preclude assuming a homogenous refractive index over the entire cell contents, or using multiple-exposure or scanning microscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of sulfates potentialize damage on cementbased materials, leading to structural failures. Therefore, structures must be designed to compensate for this effect. The mechanical properties of cement–chitin mixtures are investigated with different percentages of chitin (0.5, 1.3, and 2.1 wt.%) and aging of composite in a joint nanoscopic- and macroscopic-scale by experimental study. The objective is to increase the durability of concrete elements at coastal aquifers where concrete structures are in constant exposure to sulfate ions, chloride ions among others. Tapping mode AFM was used to characterize the surface structure and roughness of the cement pastes. To verify the chitin addition and the formation of sulfate-based aggregates Raman and IR spectra were recorded and are presented in this work. Then, force spectroscopy was used to obtain the nanomechanical properties at three different exposure times (1 day, 6 months, and 1 year) into water or a SO4 2 environment. Macroscopic parameters (e.g., compression strength of cylindrical probes) were assessed for comparison following standard guidelines. The results show a decrease of its mechanical properties as a function of the polymer concentration but more importantly, they correlate the elasticity and adhesion at the nanoscale with the behavior of the bulk material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have employed identical location transmission electron microscopy (IL-TEM) to study changes in the shape and morphology of faceted Pt nanoparticles as a result of electrochemical cycling; a procedure typically employed for activating platinum surfaces. We find that the shape and morphology of the as-prepared hexagonal nanoparticles are rapidly degraded as a result of potential cycling up to +1.3 V. As few as 25 potential cycles are sufficient to cause significant degradation, and after about 500–1000 cycles the particles are dramatically degraded. We also see clear evidence of particle migration during potential cycling. These finding suggest that great care must be exercised in the use and study of shaped Pt nanoparticles (and related systems) as electrocatlysts, especially for the oxygen reduction reaction where high positive potentials are typically employed.