995 resultados para 270


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent evidence that echinoids of the genus Echinometra have moderate visual acuity that appears to be mediated by their spines screening off-axis light suggests that the urchin Strongylocentrotus purpuratus, with its higher spine density, may have even more acute spatial vision. We analyzed the movements of 39 specimens of S. purpuratus after they were placed in the center of a featureless tank containing a round, black target that had an angular diameter of 6.5 deg. or 10 deg. (solid angles of 0.01 sr and 0.024 sr, respectively). An average orientation vector for each urchin was determined by testing the animal four times, with the target placed successively at bearings of 0 deg., 90 deg., 180 deg. and 270 deg. (relative to magnetic east). The urchins showed no significant unimodal or axial orientation relative to any non-target feature of the environment or relative to the changing position of the 6.5 deg. target. However, the urchins were strongly axially oriented relative to the changing position of the 10 deg. target (mean axis from -1 to 179 deg.; 95% confidence interval +/- 12 deg.; P<0.001, Moore's non-parametric Hotelling's test), with 10 of the 20 urchins tested against that target choosing an average bearing within 10 deg. of either the target center or its opposite direction (two would be expected by chance). In addition, the average length of the 20 target-normalized bearings for the 10 deg. target (each the vector sum of the bearings for the four trials) were far higher than would be expected by chance (P<10(-10); Monte Carlo simulation), showing that each urchin, whether it moved towards or away from the target, did so with high consistency. These results strongly suggest that S. purpuratus detected the 10 deg. target, responding either by approaching it or fleeing it. Given that the urchins did not appear to respond to the 6.5 deg. target, it is likely that the 10 deg. target was close to the minimum detectable size for this species. Interestingly, measurements of the spine density of the regions of the test that faced horizontally predicted a similar visual resolution (8.3+/-0.5 deg. for the interambulacrum and 11+/-0.54 deg. for the ambulacrum). The function of this relatively low, but functional, acuity - on par with that of the chambered Nautilus and the horseshoe crab - is unclear but, given the bimodal response, is likely to be related to both shelter seeking and predator avoidance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Variations in the ratio of magnesium to calcium (Mg/Ca) in fossil ostracodes from Deep Sea Drilling Project Site 607 in the deep North Atlantic show that the change in bottom water temperature during late Pliocene 41,000-year obliquity cycles averaged 1.5°C between 3.2 and 2.8 million years ago (Ma) and increased to 2.3°C between 2.8 and 2.3 Ma, coincidentally with the intensification of Northern Hemisphere glaciation. During the last two 100,000-year glacial-to-interglacial climatic cycles of the Quaternary, bottom water temperatures changed by 4.5°C. These results show that glacial deepwater cooling has intensified since 3.2 Ma, most likely as the result of progressively diminished deep-water production in the North Atlantic and of the greater influence of Antarctic bottom water in the North Atlantic during glacial periods. The ostracode Mg/Ca data also allow the direct determination of the temperature component of the benthic foraminiferal oxygen isotope record from Site 607, as well as derivation of a hypothetical sea-level curve for the late Pliocene and late Quaternary. The effects of dissolution on the Mg/Ca ratios of ostracode shells appear to have been minimal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The outcomes for both (i) radiation therapy and (ii) preclinical small animal radio- biology studies are dependent on the delivery of a known quantity of radiation to a specific and intentional location. Adverse effects can result from these procedures if the dose to the target is too high or low, and can also result from an incorrect spatial distribution in which nearby normal healthy tissue can be undesirably damaged by poor radiation delivery techniques. Thus, in mice and humans alike, the spatial dose distributions from radiation sources should be well characterized in terms of the absolute dose quantity, and with pin-point accuracy. When dealing with the steep spatial dose gradients consequential to either (i) high dose rate (HDR) brachytherapy or (ii) within the small organs and tissue inhomogeneities of mice, obtaining accurate and highly precise dose results can be very challenging, considering commercially available radiation detection tools, such as ion chambers, are often too large for in-vivo use.

In this dissertation two tools are developed and applied for both clinical and preclinical radiation measurement. The first tool is a novel radiation detector for acquiring physical measurements, fabricated from an inorganic nano-crystalline scintillator that has been fixed on an optical fiber terminus. This dosimeter allows for the measurement of point doses to sub-millimeter resolution, and has the ability to be placed in-vivo in humans and small animals. Real-time data is displayed to the user to provide instant quality assurance and dose-rate information. The second tool utilizes an open source Monte Carlo particle transport code, and was applied for small animal dosimetry studies to calculate organ doses and recommend new techniques of dose prescription in mice, as well as to characterize dose to the murine bone marrow compartment with micron-scale resolution.

Hardware design changes were implemented to reduce the overall fiber diameter to <0.9 mm for the nano-crystalline scintillator based fiber optic detector (NanoFOD) system. Lower limits of device sensitivity were found to be approximately 0.05 cGy/s. Herein, this detector was demonstrated to perform quality assurance of clinical 192Ir HDR brachytherapy procedures, providing comparable dose measurements as thermo-luminescent dosimeters and accuracy within 20% of the treatment planning software (TPS) for 27 treatments conducted, with an inter-quartile range ratio to the TPS dose value of (1.02-0.94=0.08). After removing contaminant signals (Cerenkov and diode background), calibration of the detector enabled accurate dose measurements for vaginal applicator brachytherapy procedures. For 192Ir use, energy response changed by a factor of 2.25 over the SDD values of 3 to 9 cm; however a cap made of 0.2 mm thickness silver reduced energy dependence to a factor of 1.25 over the same SDD range, but had the consequence of reducing overall sensitivity by 33%.

For preclinical measurements, dose accuracy of the NanoFOD was within 1.3% of MOSFET measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a MOSFET in the liver of a sacrificed mouse and treatment was delivered at 225 kV with 0.3 mm Cu filter, the dose difference was only 1.09% with use of the 4x4 cm collimator, and -0.03% with no collimation. Additionally, the NanoFOD utilized a scintillator of 11 µm thickness to measure small x-ray fields for microbeam radiation therapy (MRT) applications, and achieved 2.7% dose accuracy of the microbeam peak in comparison to radiochromic film. Modest differences between the full-width at half maximum measured lateral dimension of the MRT system were observed between the NanoFOD (420 µm) and radiochromic film (320 µm), but these differences have been explained mostly as an artifact due to the geometry used and volumetric effects in the scintillator material. Characterization of the energy dependence for the yttrium-oxide based scintillator material was performed in the range of 40-320 kV (2 mm Al filtration), and the maximum device sensitivity was achieved at 100 kV. Tissue maximum ratio data measurements were carried out on a small animal x-ray irradiator system at 320 kV and demonstrated an average difference of 0.9% as compared to a MOSFET dosimeter in the range of 2.5 to 33 cm depth in tissue equivalent plastic blocks. Irradiation of the NanoFOD fiber and scintillator material on a 137Cs gamma irradiator to 1600 Gy did not produce any measurable change in light output, suggesting that the NanoFOD system may be re-used without the need for replacement or recalibration over its lifetime.

For small animal irradiator systems, researchers can deliver a given dose to a target organ by controlling exposure time. Currently, researchers calculate this exposure time by dividing the total dose that they wish to deliver by a single provided dose rate value. This method is independent of the target organ. Studies conducted here used Monte Carlo particle transport codes to justify a new method of dose prescription in mice, that considers organ specific doses. Monte Carlo simulations were performed in the Geant4 Application for Tomographic Emission (GATE) toolkit using a MOBY mouse whole-body phantom. The non-homogeneous phantom was comprised of 256x256x800 voxels of size 0.145x0.145x0.145 mm3. Differences of up to 20-30% in dose to soft-tissue target organs was demonstrated, and methods for alleviating these errors were suggested during whole body radiation of mice by utilizing organ specific and x-ray tube filter specific dose rates for all irradiations.

Monte Carlo analysis was used on 1 µm resolution CT images of a mouse femur and a mouse vertebra to calculate the dose gradients within the bone marrow (BM) compartment of mice based on different radiation beam qualities relevant to x-ray and isotope type irradiators. Results and findings indicated that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose increases to the BM in the vertebra for these four aforementioned radiation beam qualities were found to be 31%, 17%, 8%, and 1%, respectively. Both in-vitro and in-vivo experimental studies confirmed these simulation results, demonstrating that the 320 kV, 1 mm Cu HVL beam caused statistically significant increased killing to the BM cells at 6 Gy dose levels in comparison to both the 320 kV, 4 mm Cu HVL and the 662 keV, 137Cs beams.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Los tambos son sistemas productivos muy complejos que dependen básicamente de cuatro pilares considerados como variables: el ambiente, los animales, la alimentación y los operarios. Comederos sin mantenimiento, con barro y estiércol, animales con pobre estado corporal, dietas no balanceadas o deficientes en nutrientes, predisponen a trastornos metabólicos. Personal sin capacitación y/o motivación, no realizará bien las múltiples tareas del tambo. Las vacas lecheras antes y después del parto tienen enormes cambios metabólicos y hormonales y esto es un factor que predispone a las enfermedades peripartales (IP) como: distocias, retención de placenta, edema de ubre, metritis, mastitis, cetosis, acidosis, desplazamiento de abomaso, timpanismo, hipocalcemia puerperal, lesiones podales, etc. ¿Como evaluar las variables?¿que miramos o qué metodología seguimos a campo? Para ello se propone el Índice Predictivo de Enfermedades Peripartales (IPEP). El IPEP es una guía que permite realizar un relevamiento ordenado y sistemático de los indicadores relacionados con las enfermedades peripartales sobre las variables del ambiente, los animales, la alimentación y los operarios. Es una herramienta metodológica que permite generar un diagnóstico a campo de las causas y factores predisponentes de las EP en establecimientos lecheros. A cada indicador se le asigna un número en una escala de 1 a 5, donde 1 es malo/pésimo; 2 es regular; 3 es bueno; 4 muy bueno y 5 es óptimo/excelente y los promedios de las variables da un IPEP final. El IPEP se aplicó en un tambo comercial, localizado en Brinkmann-Córdoba de 270 has, 210 vacas y 4200 litros de leche diarios. Se realizaron 4 visitas, se llenaron las planillas de indicadores del IPEP. Se observó el preparto, el rodeo en producción, las pasturas, las instalaciones y se habló con el personal. Se detectaron áreas en conflicto: dieta no balanceada, deficiente suplementación mineral, animales con pelaje seco, accesos en malas condiciones y la falta de una pileta pediluvio. En la primer visita abril de 2008 se realizó el IPEP y dio un valor de 3,11 , superior a 3 lo cual admite la calificación como tambo bueno. De acuerdo a la incidencia de EP y mortandad las pérdidas económicas para dicho IPEP fue de U$S 11.415, que equivalen al 7,3 por ciento de los ingresos por leche. Se propusieron correcciones y mejoró el índice, en septiembre del 2009, dio como resultado un IPEP de 3,71 y las perdidas económicas por EP y mortandad se estimaron en U$S 8.064, equivalentes al 0,43 de los ingresos por leche.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El efecto de la fecha de siembra sobre la producción y calidad del cultivo de maíz dulce en el norte de la provincia de Buenos Aires no ha sido estudiado y su conocimiento resulta de suma importancia para la planificación y obtención de resultados óptimos y viabilidad comercial para los productores de dicha zona. En base a esta problemática se estudió el efecto de tres fechas de siembra: 28 de octubre, 9 de noviembre y 5 de diciembre 2009 (fecha 1, 2 y 3, respectivamente) sobre el rendimiento y calidad comercial de Maíz Dulce (Zea Mays L., var. saccharata körn). La hipótesis principal que guió este trabajo fue que el atraso de la fecha de siembra reduciría el tamaño y peso de la espiga de maíz dulce afectando sus parámetros comerciales. Para poner a prueba esta hipótesis, se realizó un ensayo a campo en la localidad de Capilla del Señor, provincia de Buenos Aires. En las tres fechas mencionadas se sembró el híbrido Cahill (P) de un ciclo en fecha de siembra óptima de 75 días. El manejo de los cultivos respondió a un manejo convencional de la zona. Durante el ciclo del cultivo se llevaron a cabo determinaciones densidad y área foliar por planta. El momento de la cosecha se determinó por el método de apreciación visual del grano lechoso. Se tomaron muestras de espigas para la determinación de rendimiento y calidad comercial. El área foliar por planta no presentó diferencias significativas entre la fecha 2 y3, sin embargo hubo una tendencia hacia una mayor área foliar en la fecha 2 (2826 cm2 ± 256) que en la fecha 3 (2596 cm2 ± 256). Además, fue la fecha en la que la radiación acumulada incidente fue mayor (1605 mj/m2) en el ciclo de cultivo, ya que ésta fue en aumento desde principios de octubre hasta fines de enero; a partir de ese momento la radiación cayó marcadamente, coincidiendo con el ciclo del cultivo de la fecha 3 (1555 mj/m2). La mayor radiación incidente y la mayor capacidad de captura de la misma (Área Foliar) se tradujo en un mayor peso de la espiga (270 ± 58 gr) para los cultivos sembrados en la fecha 2 respecto de los de la fecha 3 (204 ± 58) y la fecha 1 (190 ± 58). Por otro lado, los cultivos en la fecha 2 presentaron mejor relación grano/marlo (2,57 ± 0,29) y mayor cantidad de granos comerciales (446 ± 45 granos/espiga) diferenciándose significativamente de los cultivos sembrados en la fecha 3 (1,97 ± 0,29) y la fecha 1 (0,92 ± 0,29) para la relación grano/marlo y también para los granos comerciales, 384 ± 45 y 394 ± 45 en los cultivos de la fecha 3 y 1, respectivamente. En vista de los resultados obtenidos se recomienda la fecha de principios de noviembre como fecha óptima de siembra ya que fue en la que se obtuvo el mayor rendimiento y mejor calidad de producto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En este trabajo utilizamos los razonamientos que llevan a cabo doce alumnos de Secundaria durante la resolución de una tarea matemática para detectar los errores en que incurren y las dificultades que encuentran en su ejecución. Se les propone la tarea en un contexto de entrevista semiestructurada en la que se guía a los alumnos por el camino a seguir. Entre los datos que se obtienen, se encuentran los errores aparecidos en el desarrollo de la tarea. El análisis de dichos errores se ha hecho siguiendo las clasificaciones de Evans (González, 1998) y Radatz (1979), y se conecta dichos errores con dificultades específicas siguiendo la clasificación de Socas (1997). Se concluye este trabajo con algunas reflexiones que conside-ramos interesantes para profesionales de la enseñanza de las matemáticas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper presents an improved version of the greedy open shop approximation algorithm with pre-ordering of jobs. It is shown that the algorithm compares favorably with the greedy algorithm with no pre-ordering by reducing either its absolute or relative error. In the case of three machines, the new algorithm creates a schedule with the makespan that is at most 3/2 times the optimal value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Data from a hilly forest study site at Batang Ule, Sumatra, are organized into 30 100-m × 10-m subplots lying perpendicular to the line of maximal topographic gradient, from the valley to the plateau/ridge. The following methodological question is addressed: what species diversity measures are best used in order to reveal the ecologically distinct regions in the site. The main tool used to answer this question is the α-diversity curve (Hα). Graphical examination of tree and species densities, and α-diversity curves identifies an anomalous species diversity behaviour of the ‘ridge above the slope’ subplots which may have implications on land-facet class definitions. Factor analysis of the α-diversity curves indicates that the diversity space is two-dimensional: i.e. two diversity measures are sufficient to characterize the site; the species density (H0), and the Berger-Parker index (H[infty infinity]). In the two-dimensional diversity-space three distinct species diversity groups are found which relate to the topographic gradient at the Batang Ule site. The results are compared with those for a flat homogeneous site at Pasirmayang, Sumatra. The implications of the results on land-classifications in species-diversity mapping and conservation strategy are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes how modeling technology has been used in providing fatigue life time data of two flip-chip models. Full-scale three-dimensional modeling of flip-chips under cyclic thermal loading has been combined with solder joint stand-off height prediction to analyze the stress and strain conditions in the two models. The Coffin-Manson empirical relationship is employed to predict the fatigue life times of the solder interconnects. In order to help designers in selecting the underfill material and the printed circuit board, the Young's modulus and the coefficient of thermal expansion of the underfill, as well as the thickness of the printed circuit boards are treated as variable parameters. Fatigue life times are therefore calculated over a range of these material and geometry parameters. In this paper we will also describe how the use of micro-via technology may affect fatigue life

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is the fifth in a series of six papers presenting key findings from a national study that was undertaken to investigate the role and responsibilities of midwives and to identify continuing educational need. The background to the study and the titles of the other papers in the series have been outlined in the first paper. This paper focuses on the methods used to identify the continuing educational needs of midwives, and provides an overview of the findings related to midwives' perceived confidence/competence to practice and their continuing educational needs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method of droplet generation based on applying a modulated AC high frequency magnetic field in the localized region of capillary breakup is considered as ans alternative to traditional methods for high temperature liquid melt droplet serial production by pressure variation. The method is based on a pseudo-spectral approximation with a coordinate transformation adaptin to the developing free surface. The electromagnetic field is recomputed continuously with the domain shape change. Practical application cases for liquid silicon droplets of 0.5 - 2 mm diameter are considered in detail.