970 resultados para 1403 Econometrics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In low-income settings, treatment failure is often identified using CD4 cell count monitoring. Consequently, patients remain on a failing regimen, resulting in a higher risk of transmission. We investigated the benefit of routine viral load monitoring for reducing HIV transmission.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis examines two panel data sets of 48 states from 1981 to 2009 and utilizes ordinary least squares (OLS) and fixed effects models to explore the relationship between rural Interstate speed limits and fatality rates and whether rural Interstate speed limits affect non-Interstate safety. Models provide evidence that rural Interstate speed limits higher than 55 MPH lead to higher fatality rates on rural Interstates though this effect is somewhat tempered by reductions in fatality rates for roads other than rural Interstates. These results provide some but not unanimous support for the traffic diversion hypothesis that rural Interstate speed limit increases lead to decreases in fatality rates of other roads. To the author’s knowledge, this paper is the first econometric study to differentiate between the effects of 70 MPH speed limits and speed limits above 70 MPH on fatality rates using a multi-state data set. Considering both rural Interstates and other roads, rural Interstate speed limit increases above 55 MPH are responsible for 39,700 net fatalities, 4.1 percent of total fatalities from 1987, the year limits were first raised, to 2009.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over the past four decades, the number of democracies in the world has increased exponentially. This project considers how democracy and FDI affect economic growth as well as whether the impact of FDI depends on the level of democracy in a country. Thus, I explore two major research questions: 1) Whether increased FDI speeds up economic growth, controlling for political regime type, urbanization and other developmental indicators; and 2) Whether an increase in political freedom helps or hinders economic growth, and specifically whether the impact of FDI varies depending on the political regime in the recipient country. To examine these questions, this paper used data from 150 countries over a period between 1980 and 2010 and utilized several models, testing variables such as institutions, agglomerations, urbanization, FDI and type of political regime, among others, for their impact on economic growth. I found that FDI does have a positive impact on economic growth, and that this impact is often magnified when it interacts with other relevant factors. I also found that, after controlling for other variables, FDI inflows do not have a different impact on economic growth in autocracies than they do in democracies. This may be partially explained by autocratic outliers such as China and the OPEC states, which have recently experienced rapid export-led growth. This suggests that factors such as education could have a greater impact on a country¿s economic growth than does its political system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Functional magnetic resonance imaging (fMRI) is presently either performed using blood oxygenation level-dependent (BOLD) contrast or using cerebral blood flow (CBF), measured with arterial spin labeling (ASL) technique. The present fMRI study aimed to provide practical hints to favour one method over the other. It involved three different acquisition methods during visual checkerboard stimulation on nine healthy subjects: 1) CBF contrast obtained from ASL, 2) BOLD contrast extracted from ASL and 3) BOLD contrast from Echo planar imaging. Previous findings were replicated; i) no differences between the three measurements were found in the location of the activated region; ii) differences were found in the temporal characteristics of the signals and iii) BOLD has significantly higher sensitivity than ASL perfusion. ASL fMRI was favoured when the investigation demands for perfusion and task related signal changes. BOLD fMRI is more suitable in conjunction with fast event related design.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alzheimer's disease (AD) is known to cause a variety of disturbances of higher visual functions that are closely related to the neuropathological changes. Visual association areas are more affected than primary visual cortex. Additionally, there is evidence from neuropsychological and imaging studies during rest or passive visual stimulation that the occipitotemporal pathway is less affected than the parietal pathway. Our goal was to investigate functional activation patterns during active visuospatial processing in AD patients and the impact of local cerebral atrophy on the strength of functional activation. Fourteen AD patients and fourteen age-matched controls were measured with functional magnetic resonance imaging (fMRI) while they performed an angle discrimination task. Both groups revealed overlapping networks engaged in angle discrimination including the superior parietal lobule (SPL), frontal and occipitotemporal (OTC) cortical regions, primary visual cortex, basal ganglia, and thalamus. The most pronounced differences between the two groups were found in the SPL (more activity in controls) and OTC (more activity in patients). The differences in functional activation between the AD patients and controls were partly explained by the differences in individual SPL atrophy. These results indicate that parietal dysfunction in mild to moderate AD is compensated by recruitment of the ventral visual pathway. We furthermore suggest that local cerebral atrophy should be considered as a covariate in functional imaging studies of neurodegenerative disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Autonomous system applications are typically limited by the power supply operational lifetime when battery replacement is difficult or costly. A trade-off between battery size and battery life is usually calculated to determine the device capability and lifespan. As a result, energy harvesting research has gained importance as society searches for alternative energy sources for power generation. For instance, energy harvesting has been a proven alternative for powering solar-based calculators and self-winding wristwatches. Thus, the use of energy harvesting technology can make it possible to assist or replace batteries for portable, wearable, or surgically-implantable autonomous systems. Applications such as cardiac pacemakers or electrical stimulation applications can benefit from this approach since the number of surgeries for battery replacement can be reduced or eliminated. Research on energy scavenging from body motion has been investigated to evaluate the feasibility of powering wearable or implantable systems. Energy from walking has been previously extracted using generators placed on shoes, backpacks, and knee braces while producing power levels ranging from milliwatts to watts. The research presented in this paper examines the available power from walking and running at several body locations. The ankle, knee, hip, chest, wrist, elbow, upper arm, side of the head, and back of the head were the chosen target localizations. Joints were preferred since they experience the most drastic acceleration changes. For this, a motor-driven treadmill test was performed on 11 healthy individuals at several walking (1-4 mph) and running (2-5 mph) speeds. The treadmill test provided the acceleration magnitudes from the listed body locations. Power can be estimated from the treadmill evaluation since it is proportional to the acceleration and frequency of occurrence. Available power output from walking was determined to be greater than 1mW/cm³ for most body locations while being over 10mW/cm³ at the foot and ankle locations. Available power from running was found to be almost 10 times higher than that from walking. Most energy harvester topologies use linear generator approaches that are well suited to fixed-frequency vibrations with sub-millimeter amplitude oscillations. In contrast, body motion is characterized with a wide frequency spectrum and larger amplitudes. A generator prototype based on self-winding wristwatches is deemed to be appropriate for harvesting body motion since it is not limited to operate at fixed-frequencies or restricted displacements. Electromagnetic generation is typically favored because of its slightly higher power output per unit volume. Then, a nonharmonic oscillating rotational energy scavenger prototype is proposed to harness body motion. The electromagnetic generator follows the approach from small wind turbine designs that overcome the lack of a gearbox by using a larger number of coil and magnets arrangements. The device presented here is composed of a rotor with multiple-pole permanent magnets having an eccentric weight and a stator composed of stacked planar coils. The rotor oscillations induce a voltage on the planar coil due to the eccentric mass unbalance produced by body motion. A meso-scale prototype device was then built and evaluated for energy generation. The meso-scale casing and rotor were constructed on PMMA with the help of a CNC mill machine. Commercially available discrete magnets were encased in a 25mm rotor. Commercial copper-coated polyimide film was employed to manufacture the planar coils using MEMS fabrication processes. Jewel bearings were used to finalize the arrangement. The prototypes were also tested at the listed body locations. A meso-scale generator with a 2-layer coil was capable to extract up to 234 µW of power at the ankle while walking at 3mph with a 2cm³ prototype for a power density of 117 µW/cm³. This dissertation presents the analysis of available power from walking and running at different speeds and the development of an unobtrusive miniature energy harvesting generator for body motion. Power generation indicates the possibility of powering devices by extracting energy from body motion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SPatch is an open source virtual laboratory designed to perform simulated electrophysiological experiments without the technical difficulties inherent to laboratory work. It provides the core equipment necessary for recording neuronal activity and allows the user to install the equipment, design their own protocols, prepare solutions to bathe the preparation or to fill the electrodes, and gather data. Assistance is provided for most steps with predefined components that are appropriate to a range of standard procedures. Experiments that can be performed with SPatch at present concern the study of voltage-gated channels in isolated neurons. This allows understanding the ionic mechanisms of Na+ and Ca2+ action potentials, after spike hyperpolarization, pacemaker tonic or bursting activity of neurons, delayed or sustained or adaptive firing of neurons in response to a depolarization, spontaneous depolarization of the membrane following an hyperpolarization, etc. In an educational context, the main interest of SPatch is to allow students to focus on the concepts and thought processes of electrophysiological investigation without the high equipment costs and extensive training required to perform laboratory work. It can be used to acquaint students with the relevant procedures before starting work in a real lab, or to give students an understanding of single neuron behavior and the ways it can be studied without requiring practical work. We illustrate the function and use of SPatch, explore educational issues arising from the inevitable differences between simulated and real laboratory work, and outline possible improvements.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Digitalisat der Ausg. Minsk, (1929)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We work out the phenomenology of a model of supersymmetry breaking in the presence of a tiny (tunable) positive cosmological constant, proposed by the authors in arXiv:1403.1534. It utilizes a single chiral multiplet with a gauged shift symmetry that can be identified with the string dilaton (or an appropriate compactification modulus). The model is coupled to the MSSM, leading to calculable soft supersymmetry breaking masses and a distinct low energy phenomenology that allows to differentiate it from other models of supersymmetry breaking and mediation mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Guidelines on the diagnosis and management of urinary tract infections in childhood do not address the issue of abnormalities in Na(+), K(+), Cl(-) and acid-base balance. We have conducted a narrative review of the literature with the aim to describe the underlying mechanisms of these abnormalities and to suggest therapeutic maneuvers. Abnormalities in Na(+), K(+), Cl(-) and acid-base balance are common in newborns and infants and uncommon in children of more than 3 years of age. Such abnormalities may result from factitious laboratory results, from signs and symptoms (such as excessive sweating, poor fluid intake, vomiting and passage of loose stools) of the infection itself, from a renal dysfunction, from improper parenteral fluid management or from the prescribed antimicrobials. In addition, two transient renal tubular dysfunctions may occur in infants with infectious renal parenchymal involvement: a reduced capacity to concentrate urine and pseudohypoaldosteronism secondary to renal tubular unresponsiveness to aldosterone that presents with hyponatremia, hyperkalemia and acidosis. In addition to antimicrobials, volume resuscitation with an isotonic solution is required in these children. In secondary pseudohypoaldosteronism, isotonic solutions (such as 0.9 % saline or lactated Ringer) correct not only the volume depletion but also the hyperkalemia and acidosis. In conclusion, our review suggests that in infants with infectious renal parenchymal involvement, non-renal and renal causes concur to cause fluid volume depletion and abnormalities in electrolyte and acid-base balance, most frequently hyponatremia.