818 resultados para titanium device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The new device DIAGNOdent pen based on red laser light induced fluorescence was introduced for the detection of approximal and occlusal caries. The aim of this study was to test its performance on occlusal surfaces. The new device comes with two different sapphire fibre tips: a cylindrical tip and a conical tip. The two new sapphire fibre tips were used and compared with the tip currently available with DIAGNOdent (DD). METHODS: The teeth were selected from a pool of extracted permanent human molars, which were stored frozen at -20 degrees C, until use. Prior to being measured the teeth were defrosted and cleaned. One hundred and nineteen teeth were selected and measured with the old tip and with the two new tips of the new device by two independent assessments. The teeth were histologically prepared and assessed for caries extension. RESULTS: Specificity values for D(1), D(2) and D(3) ranged between 0.69 and 0.89, sensitivity between 0.78 and 0.96. There were no statistically significant differences obtained between the two tips of the new and the one tip of the old device (p>0.05). Intra-examiner reliability with kappa values of >0.83 was high. CONCLUSIONS: In this study, the new laser fluorescence device performed on occlusal surfaces as well as the available device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The information on bacterial colonization immediately after dental implant insertion is limited. Aims: (1) to assess the early colonization on titanium implants immediately post placement through the first12 post-surgical weeks , (2) to compare the microflora at interproximal subgingival implant and adjacent tooth sites. Material and Methods: Subgingival plaque samples from implant and neighbouring teeth were studied by checkerboard DNA-DNA hybridization before, 30 min. after implant placement , 1 week, 2 weeks, 4 weeks, 8 weeks, and 12 weerks after surgery. Results: Comparing bacterial loads at implant sites between 30 min. after placement with one week data showed that only the levels of V.parvula (p<0.05) differed with higher loads at week 1. Week 12 data demonstrated significantly higher bacterial loads for 15/40 species at tooth sites compared to pre-surgery (p < values varying between 0.05 and 0.01). Between immediately post-surgery and week 12 at implant sites 29/40 species were more commonly found at week 12. Included among these bacteria at implant sites were P.gingivalis (p< 0.05), T.forsythia, (p < 0.01), and T denticola (p<0.001). Immediately post-surgery 5.9% of implants, and 26.2% of teeth and at week 12, 15.0 % of implants, and 39.1% of teeth harbored S.aureus. Comparing tooth and implant sites, significantly higher bacterial loads were found at tooth sites for 27/40 species at the 30 minutes after placement interval. This difference increased to 35/40 species at week 12. Conclusions: The colonization of bacteria occurs within 30 minutes. Colonization patterns differed between implants and tooth surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aims of the present study were (1)to assess the microbiota at implants in function diagnosed as having either peri-implantitis, or mucositis, or being clinically without symptoms of inflammation, (2) to identify explanatory factors to implant status. Material and Methods: Clinical and microbiological data were collected from 138 subjects (mean age: 62.3 ± 14.9) with 524 implants in function for an average of 10.8 years (S.D. +1.5). The checkerboard DNA-DNA hybridization method was used to identify 40 bacterial species. Results: Subjects had poor oral hygiene with a mean % plaque score 53.2 ± 24.4. In 36% of cases periodontitis was reported as the cause for implant therapy. Mucositis was diagnosed in 61.6% and per-implantitis in 15.9% of all cases. Edentulous subjects had at implants with peri-implantitis significantly higher bacterial loads for Streptococcus sanguis (p<0.01), Fusobacterium nucleatum sp. nucleatum (p<0.02), and Leptothrichia buccalis (p<0.05) than did dentate implant subjects. Dentate subjects had higher bacterial loads of Porphyromonas gingivalis (p<0.02). The levels of Fusobacterium nucleatum sp.vincentii and Capnocytophaga ochracea were explanatory to mucositis. Only a history of periodontitis as cause of tooth loss and smoking were explanatory to peri-implantitis. The microbiota was not affect by supportive care patterns. Conclusions: Presence or absence of teeth partly explains the implant microbiota. A past history of periodontitis and smoking are associated with peri-implantitis. The microbiota at implants with mucositis, or peri-implantitis is similar to that of teeth. Supportive periodontal and implant therapy fails to have an impact on implant microbiota and does not prevent mucositis and peri-implantitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Information on bacterial colonization immediately after dental implant insertion is limited. AIMS: (1) To assess the early colonization on titanium implants immediately after placement and throughout the first 12 post-surgical weeks, (2) to compare the microbiota at interproximal subgingival implant and adjacent tooth sites. MATERIAL AND METHODS: Subgingival plaque samples from implant and neighbouring teeth were studied by checkerboard DNA-DNA hybridization before surgery, 30 min after implant placement, and 1, 2, 4, 8, and 12 weeks after surgery. RESULTS: Comparing bacterial loads at implant sites between 30 min after placement with 1-week data showed that only the levels of Veillonella parvula (P<0.05) differed with higher loads at week 1 post-surgically. Week 12 data demonstrated significantly higher bacterial loads for 15/40 species at tooth sites compared with pre-surgery (P-values varying between 0.05 and 0.01). Between the period immediately after surgery and 12 weeks at implant sites, 29/40 species was more commonly found at 12 weeks. Included among these bacteria at implant sites were Porphyromonas gingivalis (P<0.05), Tannerella forsythia, (P<0.01), and Treponema denticola (P<0.001). Immediately post-surgery 5.9% of implants, and 26.2% of teeth, and at week 12, 15% of implants, and 39.1% of teeth harbored Staphylococcus aureus. Comparing tooth and implant sites, significantly higher bacterial loads were found at tooth sites for 27/40 species after 30 min following implant placement. This difference increased to 35/40 species at 12 weeks post-surgically. CONCLUSIONS: Bacterial colonization occurred within 30 min after implant placement. Early colonization patterns differed between implant and tooth surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess the microbiota at implants diagnosed with peri-implantitis, implant mucositis, or being clinically healthy. MATERIAL AND METHODS: Clinical and microbiological data were collected from 213 subjects (mean age: 65.7+/-14) with 976 implants in function (mean: 10.8 years, SD+/-1.5). Forty species were identified by the checkerboard DNA-DNA hybridization method. RESULTS: Implant mean % plaque score was 41.8+/-32.4%. Periodontitis defined by bone loss was found in 44.9% of subjects. Implant mucositis was diagnosed in 59% and peri-implantitis in 14.9% of all cases. Neisseria mucosa, Fusobacterium nucleatum sp. nucleatum, F. nucleatum sp. polymorphum, and Capnocytophaga sputigena dominated the implant sub-mucosal microbiota and the sub-gingival microbiota at tooth sites. Implant probing pocket depth at the implant site with the deepest probing depth was correlated with levels of Eikenella corrodens (r=0.16, P<0.05), the levels of F. nucleatum sp. vincentii (r=0.15, P<0.05), Porphyromonas gingivalis (r=0.14, P<0.05), and Micromonas micros (r=0.17, P=0.01). E. corrodens was found in higher levels at implants with mucositis compared with implant health (P<0.05). Subjects who lost teeth due to periodontitis had higher yields of F. nucleatum sp. vincentii (P<0.02) and N. mucosa (P<0.05). Independent of implant status subjects with teeth had higher levels of P. gingivalis (P<0.05), and Leptotrichia buccalis (P<0.05). CONCLUSIONS: At implant sites studied, few bacteria differed by whether subjects were dentate or not or by implant status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Translocation of nanoparticles (NP) from the pulmonary airways into other pulmonary compartments or the systemic circulation is controversially discussed in the literature. In a previous study it was shown that titanium dioxide (TiO2) NP were "distributed in four lung compartments (air-filled spaces, epithelium/endothelium, connective tissue, capillary lumen) in correlation with compartment size". It was concluded that particles can move freely between these tissue compartments. To analyze whether the distribution of TiO2 NP in the lungs is really random or shows a preferential targeting we applied a newly developed method for comparing NP distributions. METHODS: Rat lungs exposed to an aerosol containing TiO2 NP were prepared for light and electron microscopy at 1 h and at 24 h after exposure. Numbers of TiO2 NP associated with each compartment were counted using energy filtering transmission electron microscopy. Compartment size was estimated by unbiased stereology from systematically sampled light micrographs. Numbers of particles were related to compartment size using a relative deposition index and chi-squared analysis. RESULTS: Nanoparticle distribution within the four compartments was not random at 1 h or at 24 h after exposure. At 1 h the connective tissue was the preferential target of the particles. At 24 h the NP were preferentially located in the capillary lumen. CONCLUSION: We conclude that TiO2 NP do not move freely between pulmonary tissue compartments, although they can pass from one compartment to another with relative ease. The residence time of NP in each tissue compartment of the respiratory system depends on the compartment and the time after exposure. It is suggested that a small fraction of TiO2 NP are rapidly transported from the airway lumen to the connective tissue and subsequently released into the systemic circulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of macrophages in the clearance of particles with diameters less than 100 nm (ultrafine or nanoparticles) is not well established, although these particles deposit highly efficiently in peripheral lungs, where particle phagocytosis by macrophages is the primary clearance mechanism. To investigate the uptake of nanoparticles by lung phagocytes, we analyzed the distribution of titanium dioxide particles of 20 nm count median diameter in macrophages obtained by bronchoalveolar lavage at 1 hour and 24 hours after a 1-hour aerosol inhalation. Differential cell counts revealing greater than 96% macrophages and less than 1% neutrophils and lymphocytes excluded inflammatory cell responses. Employing energy-filtering transmission electron microscopy (EFTEM) for elemental microanalysis, we examined 1,594 macrophage profiles in the 1-hour group (n = 6) and 1,609 in the 24-hour group (n = 6). We found 4 particles in 3 macrophage profiles at 1 hour and 47 particles in 27 macrophage profiles at 24 hours. Model-based data analysis revealed an uptake of 0.06 to 0.12% ultrafine titanium-dioxide particles by lung-surface macrophages within 24 hours. Mean (SD) particle diameters were 31 (8) nm at 1 hour and 34 (10) nm at 24 hours. Particles were localized adjacent (within 13-83 nm) to the membrane in vesicles with mean (SD) diameters of 592 (375) nm at 1 hour and 414 (309) nm at 24 hours, containing other material like surfactant. Additional screening of macrophage profiles by conventional TEM revealed no evidence for agglomerated nanoparticles. These results give evidence for a sporadic and rather unspecific uptake of TiO(2)-nanoparticles by lung-surface macrophages within 24 hours after their deposition, and hence for an insufficient role of the key clearance mechanism in peripheral lungs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this follow-up study was to evaluate the clinical usefulness of a new type of 3-dimensional (3D) miniplate for open reduction and monocortical fixation of mandibular angle fractures. PATIENTS AND METHODS: In 20 consecutive patients, noncomminuted mandibular angle fractures were treated with open reduction and fixation using a 2 mm 3D miniplate system in a transoral approach. All patients were systematically monitored until 6 months postoperatively. Among the outcome parameters recorded were infection, hardware failure, wound dehiscence, and sensory disturbance of the inferior alveolar nerve. RESULTS: The mean operation time from incision to wound closure was 65 minutes. Two patients had a mucosal wound dehiscence with no consequences. None developed an infection requiring a plate removal. All but 2 patients had normal sensory function 3 months after surgery. Plate fracture occurred in one patient in whom a preceding surgical removal of the third molar had been the reason for the mandibular fracture. In the absence of clinical symptoms, the patient declined plate removal. On final follow-up, fracture healing was considered clinically complete in all patients. CONCLUSIONS: The 3D plating system described here is suitable for fixation of simple mandibular angle fractures and is an easy-to-use alternative to conventional miniplates. The system may be contraindicated in patients in whom insufficient interfragmentary bone contact causes minor stability of the fracture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The standard heart-lung machine is a major trigger of systemic inflammatory response and the morbidity attributed to conventional extracorporeal circulation (CECC) is still significant. Reduction of blood-artificial surface contact and reduction of priming volume are principal aims in minimized extracorporeal circulation (MECC) cardiopulmonary bypass systems. The aim of this paper is to give an overview of the literature and to present our experience with the MECC-smart suction system. METHODS AND RESULTS: At our institution, 1799 patients underwent isolated coronary artery bypass grafting (CABG) surgery, 1372 with a MECC-smart suction system and 427 with CECC. All in-hospital data were assessed and the results were compared between the 2 groups. Patient characteristics and the distribution of EuroSCORE risk profile in our collective were similar between both groups. Average age in the MECC collective was 67.5 +/- 11.4 years and average EuroSCORE was 5.0 +/- 1.5. Average number of distal anastomoses was similar to the average number encountered in patients undergoing CABG surgery with CECC (3.3 +/- 1.0 for MECC versus 3.2 +/- 1.1 for CECC; P = ns). Myocardial protection is superior in MECC patients with lower postoperative maximal cTnI values (11.0 +/- 10.8 micromol/L for MECC versus 24.7 +/- 25.3 micromol/L for CECC; P < .05). Postoperative recovery was faster in patients operated on with the MECC-smart suction system and discharge from the hospital was earlier than for CECC patients (7.4 +/- 1.9 days for MECC versus 8.8 +/- 3.8 days for CECC; P < .05). CONCLUSIONS: The MECC-smart suction system is a safe perfusion technique for CABG surgery. In patients operated on with this system, the clinical outcome seems to be better than in patients operated on with CECC. This promising and less damaging perfusion technology has the potential to replace CECC systems in CABG surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carotid sinus baroreceptors are involved in controlling blood pressure (BP) by providing input to the cardiovascular regulatory centers of the medulla. The acute effect of temporarily placing an electrode on the carotid sinus wall to electrically activate the baroreflex was investigated. We studied 11 patients undergoing elective carotid surgery. Baseline BP was 146+30/66+/-17 mm Hg and heart rate (HR) 72+/-7 bpm (mean +/- standard deviation). An electrode was placed upon the carotid sinus and after obtaining a steady state baseline of BP and HR, an electric current was applied and increased in 1-volt increments. A voltage dependent and highly significant reduction in BP was observed which averaged 18+/-26* and 8.0+/-12 mm Hg for systolic BP and diastolic BP, respectively. Maximal reductions occurred at 4.4+/-1.2 V: 23+/-24 mm Hg*, 16+/-10 mm Hg* and 7+/-12 bpm* for systolic BP, diastolic BP and HR, respectively ( = p <.05). Thus, electrical stimulation of the carotid sinus activates the carotid baroreflex resulting in a reduction in BP and HR. This presents a proof of concept for device based baroreflex modulation in acute BP regulation and adds to the available data which provide a rationale for evaluating this system in the context of chronic BP reduction in hypertensive patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a 18 MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel computer-assisted injection device for the delivery of highly viscous bone cements in vertebroplasty is presented. It addresses the shortcomings of manual injection systems ranging from low-pressure and poor level of control to device failure. The presented instrument is capable of generating a maximum pressure of 5000 kPa in traditional 6-ml syringes and provides an advanced control interface for precise cement delivery from outside radiation fields emitted by intraoperative imaging systems. The integrated real-time monitoring of injection parameters, such as flow-rate, volume, pressure, and viscosity, simplifies consistent documentation of interventions and establishes a basis for the identification of safe injection protocols on the longer term. Control algorithms prevent device failure due to overloading and provide means to immediately stop cement flow to avoid leakage into adjacent tissues.