979 resultados para step-up converter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report Published June 2001 - Contains key recommendations and the way forward

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report Published December 1998

Relevância:

20.00% 20.00%

Publicador:

Resumo:

District Nursing Services in Northern Ireland Follow Up Regional Report

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report Published August 1998

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Spectral frequencies of the surface electromyogram (sEMG) increase with contraction force, but debate still exists on whether this increase is affected by various methodological and anatomical factors. This study aimed to investigate the influence of inter-electrode distance (IED) and contraction modality (step-wise vs. ramp) on the changes in spectral frequencies with increasing contraction strength for the vastus lateralis (VL) and vastus medialis (VM) muscles. METHODS: Twenty healthy male volunteers were assessed for isometric sEMG activity of the VM and VL, with the knee at 90° flexion. Subjects performed isometric ramp contractions in knee extension (6-s duration) with the force gradually increasing from 0 to 80 % MVC. Also, subjects performed 4-s step-wise isometric contractions at 10, 20, 30, 40, 50, 60, 70, and 80 % MVC. Interference sEMG signals were recorded simultaneously at different IEDs: 10, 20, 30, and 50 mm. The mean (F mean) and median (F median) frequencies and root mean square (RMS) of sEMG signals were calculated. RESULTS: For all IEDs, contraction modalities, and muscles tested, spectral frequencies increased significantly with increasing level of force up to 50-60 % MVC force. Spectral indexes increased systematically as IED was decreased. The sensitivity of spectral frequencies to changes in contraction force was independent of IED. The behaviour of spectral indexes with increasing contraction force was similar for step-wise and ramp contractions. CONCLUSIONS: In the VL and VM muscles, it is highly unlikely that a particular inter-electrode distance or contraction modality could have prevented the observation of the full extent of the increase in spectral frequencies with increasing force level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the long-term disease-free and overall survival of patients with sentinel lymph node (SLN) micrometastases, in whom a completion axillary lymph node dissection (ALND) was systematically omitted. BACKGROUND: The use of step sectioning and immunohistochemistry for SLN analysis results in a more accurate histopathologic examination and a higher detection rate of micrometastases. However, the clinical relevance and therapeutic implications of SLN micrometastases remain a matter of debate. METHODS: In this prospective study, 236 SLN biopsies were performed in 234 consecutive early-stage breast cancer patients (T1, T2 </= 3 cm, cN0 M0) between 1998 and 2002. The SLN were examined by step sectioning and stained with hematoxylin and eosin and immunohistochemistry. None of the patients with negative SLN or SLN micrometastases (International Union Against Cancer classification, >.2 mm to </=2 mm) underwent a completion ALND or radiation to the axilla. Long-term overall and disease-free survivals were compared between patients with negative SLN and those with SLN micrometastases by log rank tests. RESULTS: The SLN was negative in 55% of patients (123 of 224). SLN micrometastases were detected in 27 patients (27 of 224, 12%). After a median follow-up of 77 months (range, 24-106 months), neither locoregional recurrences nor distant metastases occurred in any of the 27 patients with SLN micrometastases. There were no statistically significant differences for overall (P = .656), locoregional (P = .174), and axillary and distant disease-free survival (P = .15) between patients with negative SLN and SLN micrometastases. CONCLUSIONS: This analysis of unselected patients provides evidence that a completion level I and II ALND may be safely omitted in early-stage breast cancer patients with SLN micrometastases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2003/2004 the Department of Health, Social Services and Public Safety commissioned a value for money follow-up audit of Anaesthetics, Pain Relief and Critical Care (APRCC) services at twelve Trusts and covering fourteen hospital sites. The original study had reported in 1999/2000. Detailed follow-up reports, together with action plans have been agreed locally with Trusts. The objectives of the follow-up review were to: • Ascertain the progress made in implementing recommendations from the original study; • Provide data to compare performance across Trusts in areas such as: - Pre-operative assessments; - Organisation of post-operative pain relief; - Organisation of chronic pain services; - Levels of admissions to critical care units; - Occupancy in critical care units; and åÊ • Assess the extent of progress made by Trusts in the implementation of the Chief Medical Officer’s (CMO) recommendations from ‘Facing the Future –Building on the Lessons of Winter 1999/2000’. To enable comparisons across Trusts, data was collected for the financial year 2002/2003. In addition, relevant findings from the Audit Commission’s Acute Hospitals Portfolio have also been included. The Acute Hospital Portfolio is a collection of reviews that are undertaken at acute and specialist Trusts. They focus on key service areas and are reported along the key performance criteria of patient experience, efficiency and capacity. åÊ

Relevância:

20.00% 20.00%

Publicador:

Resumo:

December 2005 - main findings in relation to referrals, quality of nursing, caseload management, deployment and twilight services

Relevância:

20.00% 20.00%

Publicador:

Resumo:

WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infections Among Injecting Drug Users in the UK 2004

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydatid disease is caused by Echinococcus granulosus. In this study, we aimed to investigate the benefit of monitoring cases with hydatid cyst by means of immune components in patients in a long-term follow-up after surgery. Eighty-four preoperative and postoperative serum samples from 14 cases undergoing surgery for hydatid disease were evaluated in terms of immune parameters, such as total and specific IgE, IgG, IgM, IgA and complement. Total and specific IgE were determined by ELISA. Specific IgG levels were measured by indirect hemaglutination.Total IgG, IgM, IgA and complement (C3 and C4) were detected by nephelometry. Imaging studies were also carried out during the follow-up. In none of the patients hydatid cysts were detected during the follow-up. Total IgE levels in the sera of the patients decreased to normal six months after surgery. Although specific IgE against echinococcal antigens decreased one year after operation, levels were still significantly high. There were no changes in the levels of anti-Echinococcus IgG and total IgG in follow-up period. Additionally, other parameters, such as IgA, IgM, C3 and C4, were not affected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infections Among Drug Users in the UK 2003

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infections Among Drug Users in the UK 2003