995 resultados para split post dielectric resonators


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stress is inevitable during thin film growth. It is demonstrated here that the growth stress has a significant effect on the dielectric constant of high-k thin films. ZrO2 thin films were deposited on Ge by reactive direct current sputtering. Stress in these films was measured using in-situ curvature measurement tool. The growth stress was tuned from -2.8 to 0.1 GPa by controlling deposition rate. Dielectric permittivity of ZrO2 depends on temperature, phase, and stress. The correct combination of parameters-phase, texture, and stress-is shown to yield films with an equivalent oxide thickness of 8 angstrom. Growth stresses are shown to affect the dielectric constant both directly by affecting lattice parameter and indirectly through the effect on phase stability of ZrO2. (c) 2016 AIP Publishing LLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of the La3+ and Gd3+ co-doping on the structure, electric and magnetic properties of BiFeO3 (BFO) ceramics are investigated. For the compositions (x=0 and 0 <= y <= 0.15) in the perovskite structured LaxGdyBi1-xFeO3 system, a tiny residual phase of Bi2Fe4O9 is noticed. Such a secondary phase is suppressed with the incorporation of `La' content (x). The magnitude of dielectric constant (epsilon(r) increases progressively by increasing the `La' content from x=0 to 0.15 with a remarkable decrease of dielectric loss. For x=0.15, the system LaxGdyBi1-x(x+y)FeO3 exhibits highest remanent magnetization (M-r) of 0.18 emu/g and coercive magnetic field (H-c) of similar to 1 Tin the presence of external magnetic field of 9 T at 300 K. The origin of enhanced dielectric and magnetic properties of LaxGdyBil (x+y)Fe03 and the role of doping elements, La3+, Gd3+ has been discussed. (C) 2015 Elsevier Ltd and Techna Group S.r.l. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to enhance the piezoelectric b-phase, PVDF was electrospun from DMF solution. The enhanced b-phase was discerned by comparing the electrospun fibers against the melt mixed samples. While both the processes resulted in phase transformation of a-to electroactive b-polymorph in PVDF, the fraction of b-phase was strongly dependent on the adopted process. Two different nanoscopic particles: carboxyl functionalized multiwall carbon nanotubes (CNTs) and silver (Ag) decorated CNTs were used to further enhance the piezoelectric coefficient in the electrospun fibers. Fourier transform infrared spectroscopy (FTIR) and wide-angle X-ray diffraction (XRD) supports the development of piezoelectric b-phase in PVDF. It was concluded that electrospinning was the best technique for inducing the b-polymorph in PVDF. This was attributed to the high voltage electrostatic field that generates extensional forces on the polymer chains that aligns the dipoles in one direction. The ferroelectric and piezoelectric measurement on electrospun fibers were studied using piezo-response force microscope (PFM). The Ag-CNTs filled PVDF electrospun fibers showed the highest piezoelectric coefficient (d(33) = 54 pm V-1) in contrast to PVDF/CNT fibers (35 pm V-1) and neat PVDF (30 pm V-1). This study demonstrates that the piezoelectric coefficient can be enhanced significantly by electrospinning PVDF containing Ag decorated nanoparticles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oversmoothing of speech parameter trajectories is one of the causes for quality degradation of HMM-based speech synthesis. Various methods have been proposed to overcome this effect, the most recent ones being global variance (GV) and modulation-spectrum-based post-filter (MSPF). However, there is still a significant quality gap between natural and synthesized speech. In this paper, we propose a two-fold post-filtering technique to alleviate to a certain extent the oversmoothing of spectral and excitation parameter trajectories of HMM-based speech synthesis. For the spectral parameters, we propose a sparse coding-based post-filter to match the trajectories of synthetic speech to that of natural speech, and for the excitation trajectory, we introduce a perceptually motivated post-filter. Experimental evaluations show quality improvement compared with existing methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the first dielectric investigation of high-k yttrium copper titanate thin films, which were demonstrated to be very promising for nanoelectronics applications. The dielectric constant of these films is found to vary from 100 down to 24 (at 100 kHz) as a function of deposition conditions, namely oxygen pressure and film thickness. The physical origin of such variation was investigated in the framework of universal dielectric response and Cole-Cole relations and by means of voltage dependence studies of the dielectric constant. Surface-related effects and charge hopping polarization processes, strictly dependent on the film microstructure, are suggested to be mainly responsible for the observed dielectric response. In particular, the bulky behaviour of thick films deposited at lower oxygen pressure evolves towards a more complex and electrically heterogeneous structure when either the thickness decreases down to 50 nm or the films are grown under high oxygen pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have carried out dielectric and transport measurements in NdFe1-xMnxO3 (0 <= x <= 1) series of compounds and studied the variation of activation energy due to a change in Mn concentration. Despite similar ionic radii in Mn3+ and Fe3+, large variation is observed in the lattice parameters and a crossover from dynamic to static Jahn-Teller distortion is discernible. The Fe/Mn-O-Fe/Mn bond angle on the ab plane shows an anomalous change with doping. With an increase in the Mn content, the bond angle decreases until x = 0.6; beyond this, it starts rising until x = 0.8 and again falls after that. A similar trend is observed in activation energies estimated from both transport and dielectric relaxation by assuming a small polaron hopping (SPH) model. Impedance spectroscopy measurements delineate grain and grain boundary contributions separately both of which follow the SPH model. Frequency variation of the dielectric constant is in agreement with the modified Debye law from which relaxation dispersion is estimated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the first dielectric investigation of high-k yttrium copper titanate thin films, which were demonstrated to be very promising for nanoelectronics applications. The dielectric constant of these films is found to vary from 100 down to 24 (at 100 kHz) as a function of deposition conditions, namely oxygen pressure and film thickness. The physical origin of such variation was investigated in the framework of universal dielectric response and Cole-Cole relations and by means of voltage dependence studies of the dielectric constant. Surface-related effects and charge hopping polarization processes, strictly dependent on the film microstructure, are suggested to be mainly responsible for the observed dielectric response. In particular, the bulky behaviour of thick films deposited at lower oxygen pressure evolves towards a more complex and electrically heterogeneous structure when either the thickness decreases down to 50 nm or the films are grown under high oxygen pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A split-phase induction motor is fed from two three-phase voltage source inverters for speed control. This study analyses carrier-comparison based pulse width modulation (PWM) schemes for a split-phase motor drive, from a space-vector perspective. Sine-triangle PWM, one zero-sequence injection PWM where the same zero-sequence signal is used for both the inverters, and another zero-sequence injection PWM where different zero-sequence signals are employed for the two inverters are considered. The set of voltage vectors applied, the sequence in which the voltage vectors are applied, and the resulting current ripple vector are analysed for all the PWM methods. Besides all the PWM methods are compared in terms of dc bus utilisation. For the same three-phase sine reference, the PWM method with different zero-sequence signals for the two inverters is found to employ a set of vectors different from the other methods. Both analysis and experimental results show that this method results in lower total harmonic distortion and higher dc bus utilisation than the other two PWM methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical conductivity and dielectric relaxation studies on SO4 (2-) doped modified molybdo-phosphate glasses have been carried out over a wide range of composition, temperature and frequency. The d.c. conductivities which have been measured by both digital electrometer (four-probe method) and impedance analyser are comparable. The relaxation phenomenon has been rationalized using electrical modulus formalism. The use of modulus representation in dielectric relaxation studies has inherent advantages viz., experimental errors arising from the contributions of electrode-electrolyte interface capacitances are minimized. The relaxation observed in the present study is non-Debye type. The activation energies for relaxation were determined using imaginary parts of electrical modulus peaks which were close to those of the d.c. conductivity implying the involvement of similar energy barriers in both the processes. The enhanced conductivity in these glasses can be attributed to the migration of Na+, in expanded structures due to the introduction of SO4 (2-) ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

目前高速公路中央分隔带波形梁护栏立柱的实际设置中,普遍存在着由于分隔带地基强度低于压实路基,护栏立柱承载能力偏低,护栏的防护性能达不到设计要求的问题。对粘性土地基中立柱的受力情况进行了分析,并对地基为压实土与回填土两种情况进行了对比,给出了中央分隔带中立柱地基的加固方案。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to study the earthquake recurrence and the characteristics of earthquake series, rupture tests of rock samples and plexiglass samples were made. On rock samples, a number of acoustic emission (AE) and strain measuring points were deployed; the load was one side direct shear. The variation characteristics of AE and strain at different detecting points around the extra large fracture were observed and studied. On plexiglass samples, a series of inclined cracks were prefabricated by a small-scale compressive testing machine. The samples were then loaded on a shockproof platen, when the samples were loaded, the stress intensity factor (SIF) was determined by the laser interferometric technique and shadow optical method of caustics. The fracture conditions such as material toughness around the extra large fracture were also studied. From those experimental results and the theory of fracture mechanics, the earthquake recurrence period and the trend of post-seismic development were studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente estudio se realizó con el objetivo de establecer la efectividad del tratamiento de Inducción al celo de vacas en anestro post parto por medio de la administración de sales minerales, vitaminas y masajes ovarios; dicho tratamiento fue llevado a cabo en el municipio de Río Blanco departamento de Matagalpa. Caracterizándose por una buena distribución de las lluvias la mayor parte del año. El dicho municipio se da una predominancia de una cultura de gran alta productividad ganadera, el tamaño requerido de la muestra de este trabajo de 20 hembras en periodo de anestro post parto mayor de 50 días, las cuales fueron seleccionadas al azar y evalua das clínicamente por palpación rectal por un profesional de la medicina veterinaria. Los datos fueron analizados mediante la prueba de chi –cuadrado habiendo obtenido un resultado significativo a un nivel de confianza del 95% entre los tratamientos. Con base en los resultados obtenidos posterior al tratamiento de la administración de sales minerales, vitamina y masaje ovárico se alcan zó una respuesta positiva del 80 % al celo, el 80% en tasa de preñez y en relación a la aparición del celo posteri or al tratamiento se alcanzo una media de 6.13 días que al comparar la efectividad del tratamiento de solo la aplicación de masaje ovárico se observo un buen resultado positivo, superando las expectativas. En comparación con las hembras tratadas con solo masaje ovárico se obtuvo una respuesta positiva al celo de un 60%, con un 30% de tasa de preñez y 7.33 días promedio en anestro posterior al tratamiento, por lo tanto elaboramos la hipótesis basándonos en el estadígrafo de Chi-cuadrado obteniendo un resultado significativo empleando un nivel de significancia del 0.05% por lo que atribuimos las diferencias de ambos tratamientos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente trabajo fue realizado en el municipio de Condega, departamento de Estelí, bajo condiciones de trópico seco y durante la época de verano. El objetivo fu e evaluar la efectividad de la reutilización del dispositivo CIDR (Dispositivo Intravaginal Liberador de Progesterona) bajo un método modificado de aplicación que incluyó el uso de GnRH y PGF2a,sobre la inducción del celo y ovulación en vacas en anestro postparto. Las variables evaluadas fueron: La efectividad sobre: presentación de celo, ovulación, porcentaje de preñez al reutilizar 3 veces el dispositivo. El grupo control consistió en un grupo de 10 animales escogidos al azar y en anestro post parto, bajo condiciones de manejo y alimentación similar, a los grupo tratado con CIDRSYNCH, los que fueron divididos en 3 subgrupos de 10 animales cada uno que igualmente estuvieron bajo condiciones de manejo y alimentación iguales a las del grupo control. En total se emplearon 40 vacas en anestro postparto. Para el análisis estadístico se azarizó bajo un DCA, y se aplicó la prueba de Chi2 modificado por valores porcentuales. Los resultados obtenidos fueron los siguientes: El 100% (30 vacas) de los animales tratados con CIDR por primera, segunda y tercera vez presentaron celo y ovulación. En cuanto al porcentaje de preñez el comportamiento fue de un 40% al utilizar el CIDR por primera y segunda vez, en tanto a la tercera utilización bajo a un 20% similar al obtenido en el grupo control sin tratamiento hormonal. Usualmente el dispositivo CIDR se utiliza una sola vez y en animales cíclicos según prospecto, sin embargo la reutilización puede ser efectiva con lo que el costo de su aplicación se reduce haciendo más accesible el método para el uso del pequeño y mediano productor.