896 resultados para sensor grid database system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To analyse the thermoplasticity of several endodontic filling materials using the Obtura II System at different temperature settings.Methodology The following materials based on gutta-percha: Regular Obtura (OBT), Obtura Flow 150 (OBT F), Endo Flow (EDF), Odous (ODO) and the synthetic thermoplastic polymer material Resilon (RE) were heated using the Obtura II System at three temperature settings (140, 170 and 200 degrees C). Samples of the heated materials were placed on the sensor of a digital thermometer (THR-140; Instrutherm, São Paulo, Brazil) to determine their real temperature (RT) when the system was set at 140 degrees C (from 64.5 to 69 degrees C), 170 degrees C (from 73.8 to 77.5 degrees C) and 200 degrees C (from 83.6 degrees C for EDF and 100 degrees C for RE). Specimens (n = 30) were made by placing samples of each material in metallic ring moulds and compressing them between two glass slabs. After 24 h, specimens (n = 10) were heated at the different settings (RT) and submitted to compression under a 5-kg load. Plasticization was assessed by calculating the differences between the post-compression and initial diameters of each specimen. Data were submitted to ANOVA and Tukey's test at 5% significance.Results At 140 degrees C, Obtura Flow presented the highest thermoplasticity values and Regular Obtura, the lowest. At 170 degrees C, Obtura Flow and Resilon demonstrated greater plasticization. Resilon had the highest mean thermoplasticity values at 200 degrees C.Conclusions Thermoplasticity values were influenced both by the temperature settings on the Obtura II System and by the type of material analysed. Obtura Flow and Resilon had the highest mean thermoplasticity values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the clinical outcome of patients with mandibular angle fractures treated by intraoral access and a rectangular grid miniplate with 4 holes and stabilized with monocortical screws.Patients and Methods: This study included 45 patients with mandibular angle fractures from the Department of Oral and Maxillofacial Surgery São Paulo State University, Araraquara, Brazil, and from the Clinic of Oral and Maxillofacial Surgery at the University of Frankfurt, Germany. The 45 fractures of the mandibular angle were treated with a rectangular grid miniplate of a 2.0-mm system by an intraoral approach with monocortical screws. Clinical evaluations were postoperatively performed at 15 and 30 days and 3 and 6 months, and the complications encountered were recorded and treated.Results: The infection rate was 4.44% (2 patients), and in 1 patient it was necessary to replace hardware. This patient also had a fracture of the left mandibular body; 3 patients (6.66%) had minor occlusal changes that have been resolved with small occlusal adjustments. Before surgery, 15 patients (33.33%) presented with hypoesthesia of the inferior alveolar nerve; 4 (8.88%) had this change until the last clinical control, at 6 months.Conclusions: The rectangular grid miniplate used in this study was stable for the treatment of simple mandibular angle fractures through intraoral access, with low complication rates, easy handling, and easy adjustment, with a low cost. Concomitant mandibular fracture may increase the rate of complications. This plate should be indicated in fractures with sufficient interfragmentaty contact. (C) 2011 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 69:1436-1441, 2011

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We generalize a procedure proposed by Mancera and Hunt [P.F.A. Mancera, R. Hunt, Some experiments with high order compact methods using a computer algebra software-Part 1, Appl. Math. Comput., in press, doi: 10.1016/j.amc.2005.05.015] for obtaining a compact fourth-order method to the steady 2D Navier-Stokes equations in the streamfunction formulation-vorticity using the computer algebra system Maple, which includes conformal mappings and non-uniform grids. To analyse the procedure we have solved a constricted stepped channel problem, where a fine grid is placed near the re-entrant corner by transformation of the independent variables. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste trabalho e apresentar uma investigação preliminar da precisão nos resultados do sistema de localização geográfica de transmissores desenvolvido utilizando o software da rede brasileira de coleta de dados. Um conjunto de medidas de desvio Doppler de uma única passagem do satélite, considerando uma Plataforma de Coleta de Dados (PCD) e uma rede de estações de recepção terrestrês, e denominado uma rede de recepção de dados. Assim, a rede brasileira de coleta de dados com o uso de múltiplas estações de recepção permitira o incremento na quantidade de dados coletados com consequente melhora na precisão e na confiabilidade das localizações fornecidas. Consequentemente uma maior quantidade de localizações válidas e mais precisas. Os resultados e análises foram obtidos sob duas condições: na primeira foi considerada uma condição prática com dados reais e dados ideais simulados, para comparar os resultados considerando a mesma passagem do satélite, transmissor e duas estações de recepção conhecidas; na segunda foram consideradas as condições ideais simuladas a partir de medidas de um transmissor fixo, três estações de recepção e dois satélites. Os resultados utilizando a rede de recepção de dados foram bastante satisfatórios. O estudo realizado mostrou a importãncia da instalação de novas estações de recepção terrenas distribuídas no territorio nacional, para um aumento na quantidade de medidas e consequentemente uma maior quantidade de localizações válidas e mais precisas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A potentiometric sensor constructed from a mixture of 25% (m/m) spinel-type manganese oxide (lambda-MnO2), 50% (m/m) graphite powder and 25% (m/m) mineral oil is used for the determination of lithium ions in a flow injection analysis system. Experimental parameters, such as pH of the carrier solution, flow rate, injection sample volume, and selectivity for Li+ against other alkali and alkaline-earth ions and the response time of this sensor were investigated. The sensor response to lithium ions was linear in the concentration range 8.6 x 10(-5) - 1.0 x 10(-2) mol L-1 with a slope 78.9 +/- 0.3 mV dec(-1) over a wide pH range 7 - 10 (Tris buffer), without interference of other alkali and alkaline-earth metals. For a flow rate of 5.0 mL min(-1) and a injection sample volume of 408.6 muL, the relative standard deviation for repeated injections of a 5.0 x 10(-4) mol L-1 lithium ions was 0.3%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sensor was fashioned to monitor the volume of nutrient in a solid substrate-based growth media by using electrochemical admittance spectroscopy. Several experimental parameters were investigated (i.e. The use of two- or three-electrode cells, the superficial area of the electrode, the amount of nutrient solution added to the growth media, and the influence of varying the dc and ac potential) to assess how these variables affect the admittance of the system. A linear correlation was observed between the maximum of the imaginary admittance and the volume of nutrient present. The response factor was 2.8 x 10(-5) S cm(-2) ml(-1) and the limit of detection (LOD) was 0.54 ml. The humidity of the growth media does not change the response of the nutrient toward the monitoring measurements. These results demonstrate that the volume of nutrient in this solid substrate-based growth media can be assessed using a ceramic sensor to measure the imaginary admittance. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nanostructured films of lignin (macromolecule extracted from sugar cane bagasse), polypyrrole (conducting polymer) and bis butylimido perylene (organic dye) were used in the detection of trace levels of fluorine (from H2SiF6), chlorine (from NaCIO), Pb+2, Cu+2, and Cd+2 in aqueous solutions. Langmuir monolayers on ultrapure water were characterised by surface pressure-mean molecular area (II-A) isotherms. Langmuir-Blodgett (LB) films were transferred onto gold interdigitated electrodes and used as individual sensing units of an electronic tongue system. Impedance spectroscopy measurements were taken with the sensor immersed into aqueous solutions containing the ions described above in different molar concentrations. Fourier transform infrared absorption (FTIR) was employed to identify possible interactions between the LB films and the analytes in solution, and no significant changes could be observed in the FTIR spectra of BuPTCD and Ppy. Therefore, the results for lignin point to an interaction involving the electronic cloud of the phenyl groups with the metallic ions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design and characteristics of a novel electrochemical system, which uses a drop as a renewable electroanalytical sensor, are described. This article describes the performance of the electrochemical system, the coupling of the experimental arrangement with flow injection technique and a demonstration of its applicability for the measurement of sulfide. The method is based on renewable drops of ferricyanide ions, buffered by borate. The ferrocyanide ions, product of the reaction between ferricyanide and sulfide ions, are oxidized on a platinum microelectrode and the current measured is related to sulfide concentration. The measurements can be done in continuous or static flow mode. In continuous mode, the detection limit is 5.0 x 10(-5) mol L-1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Levodopa (L-dopa), the biological precursor of catecholamines, is the most widely prescribed drug in the treatment of Parkinson's disease. The present work presents a proposal for the application of a gold screen-printed electrode an electrochemical sensor for monitoring L-dopa in stationary solution and a flow system. Using the electrooxidation of L-dopa at +0.63 V in acetate buffer pH 3.0 on a gold screen-printed electrode it is possible to obtain a linear calibration curve from 9.9 x 10(-5) to 1.2 x 10(-3) mol L-1 and a detection limit of 6.8 x 10(-5) mol L-1. Under amperometric conditions (E-app = 0.8 V; flow rate = 14.1 ml, min(-1); pH 3.0), an analytical calibration graph for L-dopa was obtained from 1.0 x 10(-6) mol L-1 6.6 x 10(-4) mol L-1 with a detection limit of 9.9 x 10(-7) mol L-1. The method was successfully applied to the determination of L-dopa in commercial dosage forms without any pre-treatment. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Making diagnoses in oral pathology are often difficult and confusing in dental practice, especially for the lessexperienced dental student. One of the most promising areas in bioinformatics is computer-aided diagnosis, where a computer system is capable of imitating human reasoning ability and provides diagnoses with an accuracy approaching that of expert professionals. This type of system could be an alternative tool for assisting dental students to overcome the difficulties of the oral pathology learning process. This could allow students to define variables and information, important to improving the decision-making performance. However, no current open data management system has been integrated with an artificial intelligence system in a user-friendly environment. Such a system could also be used as an education tool to help students perform diagnoses. The aim of the present study was to develop and test an open case-based decisionsupport system.Methods: An open decision-support system based on Bayes' theorem connected to a relational database was developed using the C++ programming language. The software was tested in the computerisation of a surgical pathology service and in simulating the diagnosis of 43 known cases of oral bone disease. The simulation was performed after the system was initially filled with data from 401 cases of oral bone disease.Results: the system allowed the authors to construct and to manage a pathology database, and to simulate diagnoses using the variables from the database.Conclusion: Combining a relational database and an open decision-support system in the same user-friendly environment proved effective in simulating diagnoses based on information from an updated database.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article addresses the establishment of integrated diagnostics and recommendation system (DRIS) standards for irrigated bean crops (Phaseolus vulgaris) and compares leaf concentrations and productivity in low- and high-productivity populations. The work was carried out in Santa Fe de Goias, Goias State, Brazil, in the agricultural years 1999/2000 and 2000/2001. For the nutritional diagnosis, leaf samples were collected, and leaf concentrations of nitrogen (N), phosphorus (P), potassium (K), calcium (Ca), magnesium (Mg), sulfur (S), boron (B), copper (Cu), iron (Fe), manganese (Mn), and zinc (Zn) were established in 100 commercial bean crops. A database was set up listing the leaf nutrient content and the respective productivities, subdivided into two subpopulations, high and low productivity, using a bean yield value of 3000 kg ha-1 to separate these subpopulations. Sufficiency values found in the high-productivity population matched only for the micronutrients B and Zn. The nutritional balance among the populations studied was coherent and was lower in the high-productivity population. The DRIS standards proposed for irrigated bean farming were efficient in evaluating the nutritional status of the crop areas studied. Calcium, Cu, and S were found to be the least available nutrients, indicating high response potential for the fertilizing using these nutrients.