926 resultados para scientific visualization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Load flow visualization, which is an important step in structural and machine assembly design may aid in the analysis and eventual synthesis of compliant mechanisms. In this paper, we present a kineto-static formulation to visualize load flow in compliant mechanisms. This formulation uses the concept of transferred forces to quantify load flow from input to the output of a compliant mechanism. The magnitude and direction of load flow in the constituent members enables functional decomposition of the compliant mechanism into (i) Constraints (C): members that are constrained to deform in a particular direction and (ii) Transmitters (T): members that transmit load to the output. Furthermore, it is shown that a constraint member and an adjacent transmitter member can be grouped together to constitute a fundamental building block known as an CT set whose load flow behavior is maximally decoupled from the rest of the mechanism. We can thereby explain the deformation behavior of a number of compliant mechanisms from literature by visualizing load flow, and identifying building blocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. MATERIALS AND METHODS: Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n=20 patients; control group [CG]) or morphine sulfate (n=20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0-not visualized; 3-excellent visualization). RESULTS: Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9±0.1 versus 2.6±0.2 [P<0.001] and 2.7±0.3 versus 2.1±0.6 [P<0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9±1.3mm versus 4.9±1.3mm [P<0.05] and 3.7±1.3mm versus 2.6±0.5mm [P<0.01], respectively). CONCLUSION: Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article is aimed at addressing the current state of the art in epidemiology, pathophysiology, diagnostic procedures and treatment options for appropriate management of obstructive sleep apnea (OSA) in cardiovascular (particularly hypertensive) patients, as well as for the management of cardiovascular diseases (particularly arterial hypertension) in OSA patients. The present document is the result of the work done by a panel of experts participating in the European Union COST (COoperation in Scientific and Technological research) ACTION B26 on OSA, with the endorsement of the European Respiratory Society (ERS) and the European Society of Hypertension (ESH). These recommendations are particularly aimed at reminding cardiovascular experts to consider the occurrence of sleep-related breathing disorders in patients with high blood pressure. They are at the same time aimed at reminding respiration experts to consider the occurrence of hypertension in patients with respiratory problems at night.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We recently reported on the Multi Wave Animator (MWA), a novel open-source tool with capability of recreating continuous physiologic signals from archived numerical data and presenting them as they appeared on the patient monitor. In this report, we demonstrate for the first time the power of this technology in a real clinical case, an intraoperative cardiopulmonary arrest following reperfusion of a liver transplant graft. Using the MWA, we animated hemodynamic and ventilator data acquired before, during, and after cardiac arrest and resuscitation. This report is accompanied by an online video that shows the most critical phases of the cardiac arrest and resuscitation and provides a basis for analysis and discussion. This video is extracted from a 33-min, uninterrupted video of cardiac arrest and resuscitation, which is available online. The unique strength of MWA, its capability to accurately present discrete and continuous data in a format familiar to clinicians, allowed us this rare glimpse into events leading to an intraoperative cardiac arrest. Because of the ability to recreate and replay clinical events, this tool should be of great interest to medical educators, researchers, and clinicians involved in quality assurance and patient safety.