979 resultados para plateau airway pressure


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Taking shear-induced dilatation into consideration in shear transformation zone (STZ) operations, we derive a new yield criterion that reflects the pressure sensitivity in plastic flow in metallic glasses (MGs), which agrees well with experiments. Furthermore, an intrinsic theoretical correlation between the pressure sensitivity coefficient and the dilatation factor is revealed. It is found that the pressure sensitivity of plastic flow of MGs originates in the dilatation of microscale STZs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The phytoplankton distribution of the Shen Reservoir, Bukuru in the Jos Plateau, Nigeria was monitored at 6 depths. Higher floral abundance occurred within the upper 00-03 meters with highest values at the first 1 meter. Bacillariophyceae and Dinophyceae recorded higher values in March-April with lower values in July and January respectively. Phytoplankton were most abundant in the rainy season. Secchi disc transparency was lowest in the peak of the rainy season (July) due to higher levels of suspended matter resulting from the increased run-off from surrounding farmlands of allochthonous materials as well as higher levels of phytoplankton population arising from the former factor. The low water temperature of December/January 15 degree C plus or minus 2 degree C might have depressed growth among the major groups of plankters but enhanced rapid multiplication of the Chlorophyta, Trachelomonas which showed a bloom at this season

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The investment prospects of fish farming in the Jos-Plateau, Nigeria, strategically located in about the centre of the country are discussed with special reference to its numerous abandoned mine lakes and the tripartite role of government, universities and individuals. In the Jos-Plateau, about 17.0 km super(2) is covered by these disused mine lakes, making up about 20-30% of the area covered. In such enterprise, problems commonly encountered, like population growth and government planning policies, fish demand and supply, manpower, feed and seed availability, preservation, processing and marketing are discussed. Inspite of these, prospects still abound with regards to land-use of these numerous disused mine lakes and feed availability based on the principles of using both industrial and farm by-products for fish culture, processing and marketing. These potentials, if properly harnessed, will help to supplement the protein insufficiency in the diet of the populace. In this regard, proposals on the economics of production and sales, strategies for achieving these development goals, cost-benefit analysis and their implications in further development of fish culture are discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A physical model is presented to describe the kinds of static forces responsible for adhesion of nano-scale copper metal particles to silicon surface with a fluid layer. To demonstrate the extent of particle cleaning, Received in revised form equilibrium separation distance (ESD) and net adhesion force (NAF) of a regulated metal particle with different radii (10-300 nm) on the silicon surface in CO2-based cleaning systems under different pressures were simulated. Generally, increasing the pressure of the cleaning system decreased the net adhesion force between spherical copper particle and silicon surface entrapped with medium. For CO2 + isopropanol cleaning system, the equilibrium separation distance exhibited a maximum at temperature 313.15 K in the Equilibrium separation distance regions of pressure space (1.84-8.02 MPa). When the dimension of copper particle was given, for example, High pressure 50 nm radius particles, the net adhesion force decreased and equilibrium separation distance increased with increased pressure in the CO2 + H2O cleaning system at temperature 348.15 K under 2.50-12.67 MPa pressure range. However, the net adhesion force and equilibrium separation distance both decreased with an increase in surfactant concentration at given pressure (27.6 or 27.5 MPa) and temperature (318 or 298 K) for CO2 + H2O with surfactant PFPE COO-NH4+ or DiF(8)-PO4-Na+. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the experimental results and the characteristics of the pressure-sensitive fractured formation, a transient flow model is developed for the deep naturally-fractured reservoirs with different outer boundary conditions. The finite element equations for the model are derived. After generating the unstructured grids in the solution regions, the finite element method is used to calculate the pressure type curves for the pressure-sensitive fractured reservoir with different outer boundaries, such as the infinite boundary, circle boundary and combined linear boundaries, and the characteristics of the type curves are comparatively analyzed. The effects on the pressure curves caused by pressure sensitivity module and the effective radius combined parameter are determined, and the method for calculating the pressure-sensitive reservoir parameters is introduced. By analyzing the real field case in the high temperature and pressure reservoir, the perfect results show that the transient flow model for the pressure-sensitive fractured reservoir in this paper is correct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modelling study is performed to investigate the characteristics of both plasma flow and heat transfer of a laminar non-transferred arc argon plasma torch operated at atmospheric and reduced pressure. It is found that the calculated flow fields and temperature distributions are quite similar for both cases at a chamber pressure of 1.0 atm and 0.1 atm. A fully developed flow regime could be achieved in the arc constrictor-tube between the cathode and the anode of the plasma torch at 1.0 atm for all the flow rates covered in this study. However the flow field could not reach the fully developed regime at 0.1 atm with a higher flow rate. The arc-root is always attached to the torch anode surface near the upstream end of the anode, i.e. the abruptly expanded part of the torch channel, which is in consistence with experimental observation. The surrounding gas would be entrained from the torch exit into the torch interior due to a comparatively large inner diameter of the anode channel compared to that of the arc constrictor-tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A torch with a set of inter-electrode inserts between the cathode and the anode/nozzle with a wide nozzle exit was designed to generate plasma jets at chamber pressures of 500–10 000 Pa. The variation of the arc voltage was examined with the change in working parameters such as gas flow rate and chamber pressure. The fluctuation in the arc voltage was recorded with an oscilloscope, and the plasma jet fluctuation near the torch exit was observed with a high-speed video camera and detected with a double-electrostatic probe. Results show that the 300 Hz wave originated from the tri-phase rectified power supply was always detected under all generating conditions. Helmholtz oscillations over 3000 Hz was detected superposed on the 300 Hz wave at gas flow rates higher than 8.8 slm with a peak to valley amplitude lower than 5% of the average voltage value. No appreciable voltage fluctuation caused by the irregular arc root movement is detected, and mechanisms for the arc voltage and jet flow fluctuations are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Attempts were made to measure the gas temperature of a DC arc laminar plasma jet generated at reduced pressure by using a pair of WRe-5/26 thermocouple. Results show that the measured temperature is much lower than the value measured by using the spectral method. Theoretical work considering rarefied-gas heat transfer effects has been carried out to analyze the measured error of the thermocouple.