933 resultados para office equipment
Resumo:
This thesis focuses on using photovoltaic produced electricity to power air conditioners in a tropical climate. The study takes place in Surabaya, Indonesia at two different locations the classroom, located at the UBAYA campus and the home office, 10 km away. Indonesia has an average solar irradiation of about 4.8 kWh/m²/day (PWC Indonesia, 2013) which is for ideal conditions for these tests. At the home office, tests were conducted on different photovoltaic systems. A series of measuring devices recorded the performance of the 800 W PV system and the consumption of the 1.35 kW air conditioner (cooling capacity). To have an off grid system many of the components need to be oversized. The inverter has to be oversized to meet the startup load of the air conditioner, which can be 3 to 8 times the operating power (Rozenblat, 2013). High energy consumption of the air conditioner would require a large battery storage to provide one day of autonomy. The PV systems output must at least match the consumption of the air conditioner. A grid connect system provides a much better solution with the 800 W PV system providing 80 % of the 3.5 kWh load of the air conditioner, the other 20 % coming from the grid during periods of low irradiation. In this system the startup load is provided by the grid so the inverter does not need to be oversized. With the grid-connected system, the PV panel’s production does not need to match the consumption of the air conditioner, although a smaller PV array will mean a smaller percentage of the load will be covered by PV. Using the results from the home office tests and results from measurements made in the classroom. Two different PV systems (8 kW and 12 kW) were simulated to power both the current air conditioners (COP 2.78) and new air conditioners (COP 4.0). The payback period of the systems can vary greatly depending on if a feed in tariff is awarded or not. If the feed in tariff is awarded the best system is the 12 kW system, with a payback period of 4.3 years and a levelized cost of energy at -3,334 IDR/kWh. If the feed in tariff is not granted then the 8 kW system is the best choice with a lower payback period and lower levelized cost of energy than the 12 kW system under the same conditions.
Resumo:
The management system based on lean thinking has led to significant changes in the companies that have decided to adopt it. Frequently, those changes do not create a sustainable position coherent with the good results that are obtained. Many are the causes being discussed and analyzed, not only in academia, but also by lean manufacturing institutes and companies. The existing practices related to the managerial information system and the implementation, development, and maintenance of the lean journey may be some of such causes. This dissertation emphasizes whether the changes generated by this type of management are being followed by the managerial information system. The development of such system was in many cases based on mass production, whose principles go against lean manufacturing concepts. Thus, the objective of this dissertation is to verify whether the traditional managerial information system can meet the needs of the companies that adopt lean manufacturing principles. Through a case study based on qualitative and exploratory research in an electronic equipment assembling company, the stage of the implementation of lean thinking concepts at the time of the field research was analyzed, as well as whether the metrics, financial and non financial indicators were suitable for lean principles. The aim of such study was to empirically verify if the criticism found in the existing literature was pertinent or not. The data collected through the analysis of the documentation, the interviews with managers and in loco observation was treated through the content analysis method. The main conclusion of the research is that, although the company in question is investing in training and applying lean principles in its production line and in some administrative activities, the current managerial information system does not demonstrate the specific results obtained with lean principles. However, how changes to the managerial information system will be implemented is yet to be determined. Currently, metrics and indicators aligned with lean management are being added to the managerial reports. As more lean tools are employed, mainly with the consolidation of more value streams, the company has already diagnosed the need for new indicators. The main office has started a diagnosis of measurement and control systems in a product line in one of its affiliates with the goal of studying the possibility of applying the so called lean accounting in the future.
Resumo:
Trata das mudanças que já começaram a ocorrer no contexto empresarial e que regerão a nova economia do século xxi. Enfoca as novas exigência dos clientes, que se tornarão cada vez mais sofisticados e demandarão transformações nas atividades de front office. As empresas vencedoras estarão alicerçadas em três pilares principais: relacionamento de aprendizado com os clientes, liderança que promova a adaptação e recursos humanos autogerenciados.
Resumo:
Uma análise das principais teorias de competitividade, incluindo estudos da Ernst & Young no segmento bancário e teorias de N.Venkatraman, Michael Porter e Nigel Slack. Os principais sistemas de Office Banking do Citibank, no segmento corporativo para serviços de Cash Management são usados como estudo de caso para ilustrar estas teorias, devidamente situados na realidade do segmento de automação bancária e de office banking no Brasil e no mundo neste final de século. Palavras-chave: Cash Management - Electronic Banking - Office Banking - Electronic Delivery - Citibank - Automação bancária - Citigroup - Serviços bancários - Corporate banking
Resumo:
This paper approaches the strategy in business management and aimed at identifying and outlining the interests and commitment of stakeholders in strategic resources management concerning production and implementation of wind turbine equipment of a Brazilian wind power company and also verifying if internal and external results deriving from such activities were sustainable, taking as main reference seminal publications and periodicals relevant to the research point that discuss the Resource Theory, Stakeholders and Sustainability. An analysis was carried out to assess how stakeholders, beyond the temporal context, intermediated the composition, development and management of the organization´s resources, as well as the social, environmental and economic results obtained from resources management in the production and supply of wind turbines to a Wind Power Plant located in the State of Ceara, in order to portray that Brazil sustainability can be an important competitive advantage source that creates value for shareholders and the community (Hart & Milstein, 2003). The strategy herein applied was the qualitative investigation using a single study case, which allowed for the thorough examination of an active organization operating in the Brazilian industry of wind power and also the resources used in the production and implementation of wind turbines supplied to the a Wind Power Plant in Ceara. Considering the content analysis and the triangulation principle, three qualitative data collection methods were applied to identify and characterize stakeholders’ interest and commitment in resource management of the organization operating in the Brazilian wind power industry, as follows, semistructured deep interview with managers of tactic-strategic level and analysts of organization´s value chain nine activities, analysis of public internal and external documents; and analysis of audio-visual material. Nonetheless, to identify the internal and external economic, social and environmental results of implementation and supply of wind turbines to the Wind Power Plant in Ceara, semistructured interviews were also carried out with the residents of the region. Results showed the BNDES (Brazilian Development Bank) and the organization head office were the stakeholders who exerted the strongest influence on resources related to production and implementation of the aerogenerator product at Trairi Wind Plant in Ceara. Concerning the organization resources, at the current stage of the Brazilian Wind Industry ,although the brand, reliability and reputation of the organization under study were valuable esources, rare, hard to imitate and exploited by the organization, it was noticed that opposed to RBV, they did not actually represent a source of competitive advantage . For the local community the social, economic and environmental results related to the wind turbines implementation were more positive than negative, despite the fact that the productive process caused negative environmental impacts such as the high emission of CO2 to transport wind turbines components to Trairi Wind Power Plant.
Resumo:
We use a unique dataset of c. 2200 commercial towers located in the city of Sao Paulo from 2005:Q3 to 2014:Q3 to study the relationship between asset quality and potential income in different niches of the office market. Our evidence suggests a rent premium in the market for larger office space (corporate) and that building quality is more relevant in this segment. We hypothesize such difference is due to larger competition and commoditization in the market for smaller office space (office) as income in this segment tends to be insensible to different levels of asset quality when we control for spatial variation. We also find that rent premiums associated with building class are monotonically increasing, but not strictly positive across certain quality thresholds. Thus, landlords and developers should take into consideration the market niche and acceptable target building class levels when designing their investment plans in order to maximize income .
Resumo:
Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Desinfecção de superfície é um procedimento realizado nas áreas externas do equipamento odontológico e demais itens do consultório. O objetivo deste trabalho foi analisar a ação de quatro desinfetantes utilizados em Odontologia: álcool etílico a 77°GL, composto fenólico (Duplofen), iodóforo (PVP-I) e solução de álcool etílico a 77°GL com 5% de clorexidina para desinfecção de superfície. Foram analisados quatro pontos em cada equipamento (carter, pia de lavagem de mãos, encosto de cabeça da cadeira e superfície frontal externa do refletor), utilizando-se a técnica de spray-wipe-spray. de cada ponto, foram coletadas amostras utilizando-se placas de superfície contendo ágar Mitis Salivarius bacitracina sacarose, ágar Sabouraud Dextrose com cloranfenicol, ágar MacConkey e ágar-sangue para contagem de estreptococos do grupo mutans, leveduras do gênero Candida, bactérias gram-negativas e contagem total de microrganismos, respectivamente (ufc/placa). Os resultados foram analisados estatisticamente utilizando-se teste t de Student para comparação entre as médias de ufc/placa. O desinfetante que demonstrou ser mais efetivo na redução microbiana foi a solução alcoólica de clorexidina, principalmente para bactérias gram-positivas. O iodo e o composto fenólico mostraram ser bastante eficazes na redução microbiana. O álcool etílico a 77°GL foi o menos eficaz dos quatro desinfetantes analisados, mas apesar de não ser indicado como desinfetante de superfície, mostrou, no presente trabalho, redução microbiana estatisticamente significativa após o processo de desinfecção.
Resumo:
Purpose: This study compared five types of chemical catalyzing agents added to 35% hydrogen peroxide gel, with regard to their capacity of intensifying in-office dental bleaching results.Methods: One-hundred and twenty bovine incisors were used, of which the crowns and roots were cut in the incisor-apical direction, to acquire the dimensions of a human central incisor. The specimens were sectioned in the mesiodistal direction by means of two longitudinal cuts, the lingual halves being discarded. The vestibular halves received prophylaxis with a bicarbonate jet, ultrasound cleaning and acid etching on the dentinal portion. Next, the specimens were stored in receptacles containing a 25% instant coffee solution for two weeks. After the darkening period, initial measurement of the shade obtained was taken with the Easy Shade appliance, which allowed it to be quantified by the CIELab* method. The samples were divided into six groups, corresponding to the chemical activator used: a) none (CON); b) ferric chloride (CF); c) ferrous sulphate (SF); d) manganese gluconate (GM); e) manganese chloride (CM); f) mulberry root extract (RA). Each group received three 10-minute applications of the gels containing the respective activating agents. Next, a new shade measurement was made.Results: The Analysis of Variance and Tukey tests (alpha=5%) showed statistically significant differences for the shade perception values (p=0.002). Groups GM, CM and RA showed significantly higher means than the control group.Conclusion: The presence of some chemical activators is capable of resulting in a significant increase in tooth shade variation.
Resumo:
Objective. The aim of this study was to assess the enamel microhardness treated with three in-office bleaching agents, containing 35% hydrogen peroxide with different acidity. Materials and methods. Bovine incisors were divided into three groups that received the following bleaching agents: Whiteness HP, Total Bleach and Opalescence Xtra. Three gel applications/10-min each, totaling 30-min of bleaching treatment, were made on the teeth and activated with a blue LED (1000 mW/470 nm) combined to a LASER (120 mW/795 nm) device (Easy Bleach-Clean Line). Vickers hardness (VH) was evaluated at baseline and after the bleaching procedure. The values of Hardness loss [HNL] (% reduction) were calculated. The two-sample t-test was used for comparison of the HNL of the three bleaching products (5% level of significance). Results. The Opalescence Xtra, which had the lowest pH value (pH = 4.30), showed a significant increase of HNL when compared with Total Bleach bleaching agent, which had the highest pH value (pH = 6.62). Conclusions. The 35% hydrogen peroxide bleaching agents resulted in a reduction in surface enamel microhardness and bleaching with the most acid agent resulted in a significant enamel hardness loss compared to the less acid agent (4.30 vs 6.62). Strategies proposed to reduce the enamel loss after bleaching treatment may include the use of daily fluoride therapy, mouth rinsing (fluoride, milk and sodium bicarbonate solution), fluoride/bicarbonate dentifrices without abrasives, do not toothbrush immediately after bleaching, fluorides and calcium add to bleaching agents.