987 resultados para near-infrared spectroscopy
Resumo:
Very high concentrations of uranium (up to 4000 ppm) were found in a natural soil in the Dischma valley, an alpine region in the Grisons canton in Switzerland. The goal of this study was to examine the redox state and the nature of uranium binding in the soil matrix in order to understand the accumulation mechanism. Pore water profiles collected from Dischma soil revealed the establishment of anoxic conditions with increasing soil depth. A combination of chemical extraction methods and spectroscopy was applied to characterize the redox state and binding environment of uranium in the soil. Bicarbonate extraction under anoxic conditions released most of the uranium indicating that uranium occurs predominantly in the hexavalent form. Surprisingly, the uranium redox state did not vary greatly as a function of depth. X-ray absorption near edge spectroscopy (XANES), confirmed that uranium was present as a mixture of U(VI) and U(IV) with U(VI) dominating. Sequential extractions of soil samples showed that the dissolution of solid organic matter resulted in the simultaneous release of the majority of the soil uranium content (>95%). Extended X-ray absorption fine structure (EXAFS) spectroscopy also revealed that soil-associated uranium in the soil matrix was mainly octahedrally coordinated, with an average of 1.7 axial (at about 1.76 Ã…) and 4.6 to 5.3 equatorial oxygen atoms (at about 2.36 Ã…) indicating the dominance of a uranyl-like (UO22+) structure presumably mixed with some U(IV). An additional EXAFS signal (at about 3.2 Ã…) identified in some spectra suggested that uranium was also bound (via an oxygen atom) to a light element such as carbon, phosphorus or silicon. Gamma spectrometric measurements of soil profiles failed to identify uranium long-life daughter products in the soil which is an indication that uranium originates elsewhere and was transported to its current location by water. Finally, it was found that the release of uranium from the soil was significantly promoted at very low pH values (pH 2) and increased with increasing pH values (between pH 5 and 9).
Resumo:
The aim of this work was to evaluate the humus composition from an Ultisol from Campos dos Goytacazes, RJ, Brazil. Soil samples of four depths (0-0.05, 0.05-0.10, 0.10-0.20 and 0.20-0.40 m) and its chemical nature were analysed by elemental composition, E4/E6 ratios and Fourier transformed infrared spectroscopy. The bioactivity of these humified substances was evaluated through their action on maize root growth and H+-ATPase activity of roots microsomes. In topsoil, the content of high condensed alkaline soluble humic substances is greater than that found in the subsuperficial layers. The chemical nature of humic and fulvic acids also varied with the soil depth. The humic acids isolated from the soil samples exhibited higher bioactivity compared with the fulvic acids. Moreover, the results suggest that more condensed humic substances can promote highest stimulation of the microsomal H+-ATPases from maize roots. These data reinforce the concept that the activity of the H+ pumps can be used as a biochemical marker for evaluation of humic substances bioactivity.
Resumo:
The objective of this work was to evaluate the distribution pattern and composition of soil organic matter (SOM) and its physical pools of Leptosols periodically affected by fire over the last 100 years in South Brazil. Soil samples at 0-5, 5-10, and 10-15 cm depths were collected from the following environments: native pasture without burning in the last year and grazed with 0.5 livestock per hectare per year (1NB); native pasture without burning in the last 23 years and grazed with 2.0 livestock per hectare per year (23NB); and an Araucaria forest (AF). Physical fractionation was performed with the 0-5 and 5-10 cm soil layers. Soil C and N stocks were determined in the three depths and in the physical pools, and organic matter was characterized by infrared spectroscopy and thermogravimetry. The largest C stocks in all depths and physical pools were found under the AF. The 23NB environment showed the lowest soil C and N stocks at the 5-15 cm depth, which was related to the end of burning and to the higher grazing intensity. The SOM of the occluded light fraction showed a greater chemical recalcitrance in 1NB than in 23NB. Annual pasture burning does not affect soil C stocks up to 15 cm of depth.
Resumo:
The objective of this work was to evaluate the use of multispectral remote sensing for site-specific nitrogen fertilizer management. Satellite imagery from the advanced spaceborne thermal emission and reflection radiometer (Aster) was acquired in a 23 ha corn-planted area in Iran. For the collection of field samples, a total of 53 pixels were selected by systematic randomized sampling. The total nitrogen content in corn leaf tissues in these pixels was evaluated. To predict corn canopy nitrogen content, different vegetation indices, such as normalized difference vegetation index (NDVI), soil-adjusted vegetation index (Savi), optimized soil-adjusted vegetation index (Osavi), modified chlorophyll absorption ratio index 2 (MCARI2), and modified triangle vegetation index 2 (MTVI2), were investigated. The supervised classification technique using the spectral angle mapper classifier (SAM) was performed to generate a nitrogen fertilization map. The MTVI2 presented the highest correlation (R²=0.87) and is a good predictor of corn canopy nitrogen content in the V13 stage, at 60 days after cultivating. Aster imagery can be used to predict nitrogen status in corn canopy. Classification results indicate three levels of required nitrogen per pixel: low (0-2.5 kg), medium (2.5-3 kg), and high (3-3.3 kg).
Resumo:
Erilaisia epäpuhtauksia kulkeutuu paperinvalmistusprosessiin ja monenlaisia saostumia muodostuu paperinvalmistuksen prosesseissa. Epäpuhtaudet voivat aiheuttaa prosessiongelmia sekä alentaa tuotteen laatua. Epäpuhtauksien alkuperän ja koostumuksen selvittäminen edellyttää usein erilaisten analyysimenetelmien käyttöä. Epäpuhtauksien luokittelu on useasti välttämätöntä ennen tarkempaa kemiallista analyysia. Paperinvalmistuksen epäpuhtauksien kvalitatiiviseen luokitteluun on yleisimmin käytetty mikroskopian, IR-spektroskopian ja analyyttisen pyrolyysin menetelmiä. Raman spektroskopia on harvinaisempi menetelmä paperiteollisuuden tutkimuksessa. Raman instrumenttien kehittyminen on ollut voimakasta viimeisen vuosikymmenen aikana. Raman spektroskopia onkin osoittanut mandollisuutensa polymeerien, lääketeollisuuden ja polttoaineteollisuuden tutkimuksissa. Tässä työssä tutkittiin erään elintarvikepakkauskartongin epäpuhtauksia Raman spektroskoopilla. Työn tavoitteena oli selvittää Raman analyysin käyttökelpoisuutta kartongin epäpuhtauksien online-luokittelussa. Tutkimukset suoritettiin Spectracoden RP-1 Raman instrumentilla. Tutkimukset osoittivat, että näytteen fluoresenssi ja näytteen hajoaminen asettavat rajoituksia epäpuhtauksien Raman analyysille. Epäpuhtauksien online-tunnistaminen toimii käytettäessä suuria lasertehoja ja säteilytysaikoja. Näytteiden laserherkkyys ja fluoresenssi rajoittavat kuitenkin suurien laiteparametrien käyttöä. Laiteparametrien pienentäminen johti mittauksien signaali-kohina suhteen alenemiseen, mikä puolestaan aiheutti online-tunnistuksen toimimattomuuden.
Resumo:
The presence of hydrogen in polysilicon films obtained at low temperatures by hot-wire CVD and the post-deposition oxidation by air-exposure of the films are studied in this paper. The experimental results from several characterization techniques (infrared spectroscopy, X-ray photoelectron spectroscopy, secondary ion mass spectrometry and wavelength dispersive spectroscopy) showed that hydrogen and oxygen are homogeneously distributed at grain boundaries throughout the depth of the films. Hydrogen is introduced during the growth process and its concentration is higher in samples deposited at lower temperatures. Oxygen diffuses along the grain boundaries and binds to silicon atoms, mainly in Si 2O groups.
Resumo:
Background:Microcystic macular edema can occur after optic neuropathies of various etiologies, and is easily demonstrated by OCT. We report a cohort of patients with microcystic macular edema. Patients and Methods: All patients with optic neuropathy and microcystic macular edema were enrolled. Demographics, visual function, retinal angiographies and OCT parameters were studied. Results: Nineteen patients (23 eyes) exhibited microcystic macular edema: 10 men/9 women, aged 17-91 years. Etiologies of optic nerve atrophy were compressive (5), inflammatory (4), glaucoma (3), ischemic (3), trauma (2), degenerative (1), and hereditary (1). Median visual acuity was 4/10 (NLP-12/10). Fluorescein angiography showed no leakage. Topography of the microcystic macular edema correlated with near infrared images but with visual field defects in only 26 %. OCT parameters were all abnormal. Conclusions: Microcystic macular edema is a non-specific manifestation from an optic neuropathy of any etiology. The precise mechanism leading to microcystic macular edema remains unknown but trans-synaptic retrograde degeneration with Müller cells dysfunction is likely.
Resumo:
By exciting at 788 nm, we have characterized the near infrared emissions of trivalent thulium ions in monoclinic KGd(WO4)2 single crystals at 1.48 and 1.84 mm as a function of dopant concentration from 0.1% to 10% and temperature from 10 K to room temperature. We used the reciprocity method to calculate the maximum emission cross-section of 3.0310220 cm2 at 1.838 mm for the polarization parallel to the Nm principal optical direction. These results agrees well with the experimental data. Experimental decay times of the 3H4!3F4 and 3F4!3H6 transitions have been measured as a function of thulium concentration.
Resumo:
In traffic accidents involving motorcycles, paint traces can be transferred from the rider's helmet or smeared onto its surface. These traces are usually in the form of chips or smears and are frequently collected for comparison purposes. This research investigates the physical and chemical characteristics of the coatings found on motorcycles helmets. An evaluation of the similarities between helmet and automotive coating systems was also performed.Twenty-seven helmet coatings from 15 different brands and 22 models were considered. One sample per helmet was collected and observed using optical microscopy. FTIR spectroscopy was then used and seven replicate measurements per layer were carried out to study the variability of each coating system (intravariability). Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) were also performed on the infrared spectra of the clearcoats and basecoats of the data set. The most common systems were composed of two or three layers, consistently involving a clearcoat and basecoat. The coating systems of helmets with composite shells systematically contained a minimum of three layers. FTIR spectroscopy results showed that acrylic urethane and alkyd urethane were the most frequent binders used for clearcoats and basecoats. A high proportion of the coatings were differentiated (more than 95%) based on microscopic examinations. The chemical and physical characteristics of the coatings allowed the differentiation of all but one pair of helmets of the same brand, model and color. Chemometrics (PCA and HCA) corroborated classification based on visual comparisons of the spectra and allowed the study of the whole data set at once (i.e., all spectra of the same layer). Thus, the intravariability of each helmet and its proximity to the others (intervariability) could be more readily assessed. It was also possible to determine the most discriminative chemical variables based on the study of the PCA loadings. Chemometrics could therefore be used as a complementary decision-making tool when many spectra and replicates have to be taken into account. Similarities between automotive and helmet coating systems were highlighted, in particular with regard to automotive coating systems on plastic substrates (microscopy and FTIR). However, the primer layer of helmet coatings was shown to differ from the automotive primer. If the paint trace contains this layer, the risk of misclassification (i.e., helmet versus vehicle) is reduced. Nevertheless, a paint examiner should pay close attention to these similarities when analyzing paint traces, especially regarding smears or paint chips presenting an incomplete layer system.
Resumo:
The University of Barcelona is developing a pilot-scale hot wire chemical vapor deposition (HW-CVD) set up for the deposition of nano-crystalline silicon (nc-Si:H) on 10 cm × 10 cm glass substrate at high deposition rate. The system manages 12 thin wires of 0.15-0.2 mm diameter in a very dense configuration. This permits depositing very uniform films, with inhomogeneities lower than 2.5%, at high deposition rate (1.5-3 nm/s), and maintaining the substrate temperature relatively low (250 °C). The wire configuration design, based on radicals' diffusion simulation, is exposed and the predicted homogeneity is validated with optical transmission scanning measurements of the deposited samples. Different deposition series were carried out by varying the substrate temperature, the silane to hydrogen dilution and the deposition pressure. By means of Fourier transform infrared spectroscopy (FTIR), the evolution in time of the nc-Si:H vibrational modes was monitored. Particular importance has been given to the study of the material stability against post-deposition oxidation.
Resumo:
La spectroscopie infrarouge (FTIR) est une technique de choix dans l'analyse des peintures en spray (traces ou bonbonnes de référence), grâce à son fort pouvoir discriminant, sa sensibilité, et ses nombreuses possibilités d'échantillonnage. La comparaison des spectres obtenus est aujourd'hui principalement faite visuellement, mais cette procédure présente des limitations telles que la subjectivité de la prise de décision car celle-ci dépend de l'expérience et de la formation suivie par l'expert. De ce fait, de faibles différences d'intensités relatives entre deux pics peuvent être perçues différemment par des experts, même au sein d'un même laboratoire. Lorsqu'il s'agit de justifier ces différences, certains les expliqueront par la méthode analytique utilisée, alors que d'autres estimeront plutôt qu'il s'agit d'une variabilité intrinsèque à la peinture et/ou à son vécu (par exemple homogénéité, sprayage, ou dégradation). Ce travail propose d'étudier statistiquement les différentes sources de variabilité observables dans les spectres infrarouges, de les identifier, de les comprendre et tenter de les minimiser. Le deuxième objectif principal est de proposer une procédure de comparaison des spectres qui soit davantage transparente et permette d'obtenir des réponses reproductibles indépendamment des experts interrogés. La première partie du travail traite de l'optimisation de la mesure infrarouge et des principaux paramètres analytiques. Les conditions nécessaires afin d'obtenir des spectres reproductibles et minimisant la variation au sein d'un même échantillon (intra-variabilité) sont présentées. Par la suite une procédure de correction des spectres est proposée au moyen de prétraitements et de sélections de variables, afin de minimiser les erreurs systématiques et aléatoires restantes, et de maximiser l'information chimique pertinente. La seconde partie présente une étude de marché effectuée sur 74 bonbonnes de peintures en spray représentatives du marché suisse. Les capacités de discrimination de la méthode FTIR au niveau de la marque et du modèle sont évaluées au moyen d'une procédure visuelle, et comparées à diverses procédures statistiques. Les limites inférieures de discrimination sont testées sur des peintures de marques et modèles identiques mais provenant de différents lots de production. Les résultats ont montré que la composition en pigments était particulièrement discriminante, à cause des étapes de corrections et d'ajustement de la couleur subies lors de la production. Les particularités associées aux peintures en spray présentes sous forme de traces (graffitis, gouttelettes) ont également été testées. Trois éléments sont mis en évidence et leur influence sur le spectre infrarouge résultant testée : 1) le temps minimum de secouage nécessaire afin d'obtenir une homogénéité suffisante de la peinture et, en conséquence, de la surface peinte, 2) la dégradation initiée par le rayonnement ultra- violet en extérieur, et 3) la contamination provenant du support lors du prélèvement. Finalement une étude de population a été réalisée sur 35 graffitis de la région lausannoise et les résultats comparés à l'étude de marché des bonbonnes en spray. La dernière partie de ce travail s'est concentrée sur l'étape de prise de décision lors de la comparaison de spectres deux-à -deux, en essayant premièrement de comprendre la pratique actuelle au sein des laboratoires au moyen d'un questionnaire, puis de proposer une méthode statistique de comparaison permettant d'améliorer l'objectivité et la transparence lors de la prise de décision. Une méthode de comparaison basée sur la corrélation entre les spectres est proposée, et ensuite combinée à une évaluation Bayesienne de l'élément de preuve au niveau de la source et au niveau de l'activité. Finalement des exemples pratiques sont présentés et la méthodologie est discutée afin de définir le rôle précis de l'expert et des statistiques dans la procédure globale d'analyse des peintures. -- Infrared spectroscopy (FTIR) is a technique of choice for analyzing spray paint speciments (i.e. traces) and reference samples (i.e. cans seized from suspects) due to its high discriminating power, sensitivity and sampling possibilities. The comparison of the spectra is currently carried out visually, but this procedure has limitations such as the subjectivity in the decision due to its dependency on the experience and training of the expert. This implies that small differences in the relative intensity of two peaks can be perceived differently by experts, even between analysts working in the same laboratory. When it comes to justifying these differences, some will explain them by the analytical technique, while others will estimate that the observed differences are mostly due to an intrinsic variability from the paint sample and/or its acquired characteristics (for example homogeneity, spraying, or degradation). This work proposes to statistically study the different sources of variability observed in infrared spectra, to identify them, understand them and try to minimize them. The second goal is to propose a procedure for spectra comparison that is more transparent, and allows obtaining reproducible answers being independent from the expert. The first part of the manuscript focuses on the optimization of infrared measurement and on the main analytical parameters. The necessary conditions to obtain reproducible spectra with a minimized variation within a sample (intra-variability) are presented. Following that a procedure of spectral correction is then proposed using pretreatments and variable selection methods, in order to minimize systematic and random errors, and increase simultaneously relevant chemical information. The second part presents a market study of 74 spray paints representative of the Swiss market. The discrimination capabilities of FTIR at the brand and model level are evaluated by means of visual and statistical procedures. The inferior limits of discrimination are tested on paints coming from the same brand and model, but from different production batches. The results showed that the pigment composition was particularly discriminatory, because of the corrections and adjustments made to the paint color during its manufacturing process. The features associated with spray paint traces (graffitis, droplets) were also tested. Three elements were identified and their influence on the resulting infrared spectra were tested: 1) the minimum shaking time necessary to obtain a sufficient homogeneity of the paint and subsequently of the painted surface, 2) the degradation initiated by ultraviolet radiation in an exterior environment, and 3) the contamination from the support when paint is recovered. Finally a population study was performed on 35 graffitis coming from the city of Lausanne and surroundings areas, and the results were compared to the previous market study of spray cans. The last part concentrated on the decision process during the pairwise comparison of spectra. First, an understanding of the actual practice among laboratories was initiated by submitting a questionnaire. Then, a proposition for a statistical method of comparison was advanced to improve the objectivity and transparency during the decision process. A method of comparison based on the correlation between spectra is proposed, followed by the integration into a Bayesian framework at both source and activity levels. Finally, some case examples are presented and the recommended methodology is discussed in order to define the role of the expert as well as the contribution of the tested statistical approach within a global analytical sequence for paint examinations.
Resumo:
Le cancer de la vessie est le deuxième cancer urologique le plus fréquent dans le monde. La plupart des patients (75%) sont initialement diagnostiqués avec un cancer non musculo- invasif. Après résection trans-urétrale, ie traitement standard pour ce type de lésion chez les patients présentant un risque important de récidive/progression consiste en une série d'instillations intravésicales du Bacille de Calmette-Guerin (i.e. le vaccin BCG). Cependant cette "BCG thérapie" est associée à des effets secondaires non négligeables et s'avère inefficace dans 30% des cas, des limitations donc importantes qui soulignent la nécessité de développer des stratégies thérapeutiques alternatives. L'utilisation d'antigènes associés aux tumeurs (TAA) comme vaccin, combinée à une application locale d'immunostimulants sur le site tumoral, est une approche prometteuse en vue de maximiser les réponses immunitaires anti-tumorales localement. Nous montrons que la bactérie vivante atténuée Ty21a, issue du vaccin Vivotif® contre la fièvre typhoïde, peut être utilisée comme immunostimulant intravésical (IVES), mais ce uniquement dans le cas où la bactérie est en phase exponentielle de croissance (Vivotif exp). En effet, l'instillation IVES de Vivotif exp à la suite d'une vaccination par un TAA, un antigène mineur d'histocompatibilité mâle H-Y (Uty), permet d'augmenter de 15 fois le nombre de cellules T CD8 totales et spécifiques de l'antigène dans la vessie. Le recrutement des cellules T est TLR4-dépendent, ce qui suggère un rôle des lipopolysaccharides du Vivotif exp. Par ailleurs, en comparaison avec le contenu bactérien de la capsule de Vivotif, les bactéries en phase exponentielle de croissance permettent également une augmentation préférentielle des chemokines C5/C5a, CXCL1, CXCL2 et CXCL5 dans la vessie, mais pas du nombre de cellules T exprimant les récepteurs apparentés (C5aR et CXCR2). De plus, combiner la vaccination Uty avec le Vivotif exp en IVES permet d'améliorer la survie des souris présentant une tumeur orthotopique de la vessie exprimant l'antigène Uty (lignée tumorale murine MB49). Puisque pour certains cancers, aucun TAA - du moins exprimé à tous les stades tumoraux - n'est identifié, il est nécessaire de développer d'autres approches non vaccinales. Dans une deuxième partie de ce travail de thèse, nous avons donc investigué deux stratégies permettant d'induire une destruction des cellules tumorales, la thérapie génique par gène de suicide, d'une part, et la thérapie photodynamique dans le proche infrarouge (NIR-PDT), d'autre part. Pour appliquer ces thérapies, nous avons utilisé comme vecteur sûr et non toxique une forme non réplicative du virus du « Human Papillomavirus » (HPV) capable de "pseudo-infecter" préférentiellement les souris présentant des tumeurs vésicales (MB49). L'utilisation de pseudovirions (PsV) HPV portant comme gène suicide la thymidine kinase, une enzyme du virus de l'herpès simplex, suivi d'un traitement par la prodrogue Ganciclovir, permet de tuer 90% des cellules MB49 in-vitro ainsi que de ralentir significativement le développement des tumeurs vésicales in-vivo. Par ailleurs, l'emploi de particules pseudo- virales HPV couplées à la phtalocyanine IR700, un pigment photosensible présentant un pouvoir cytotoxique une fois activé, permet de tuer, après application d'une lumière dans le proche infrarouge, quasi 100% des cellules MB49 in-vitro et, plus important, de régresser des tumeurs in-vivo. De façon générale, ce travail de thèse présente des approches thérapeutiques innovantes et prometteuses pour le traitement des patients avec un cancer non musculo-invasif de la vessie. -- Bladder cancer is the second most common urological malignancy in the world. At initial diagnosis, non-muscle invasive bladder cancer (NMIBC) accounts for 75% of bladder cancer. The standard of care of NMIBC consists of intravesical (IVES) treatments with Bacillus- Calmette-Guerin (BCG) following transurethral resections of the lesions. However, repeated BCG treatments are associated with significant side effects and treatment failure may occur in 30% of the cases, underlying the necessity of alternative therapeutic strategies. The use of tumor-associated antigens (TAA) as vaccines followed by the local application of immunostimulants where the tumor resides is a promising approach to increase anti-tumor immune responses locally. We show that live attenuated Ty21a bacteria used from the vivotif® vaccine against typhoid fever can efficiently be used as IVES immunostimulant, only if bacteria are grown to exponential phase (Vivotif exp). In this condition, IVES immunostimulation after TAA vaccination with a minor histocompatibility male antigen HY (Uty) resulted in more than 15-fold increase of both vaccine-specific and total CD8-T cells in the bladder. T cell recruitment was mediated by TLR-4 suggesting that it was mainly mediated by lipopolysaccharides of Vivotif exp. In addition, these bacteria, as compared to the bacterial content of the vivotif capsule preferentially increased C5/C5a, CXCL1, CXCL2 and CXCL5 chemokines, but not the numbers of T cells expressing the cognate receptors (C5aR and CXCR2). Combination of IVES Vivotif exp with Uty vaccination improved survival of mice with pre-established orthotopic Uty-expressing MB49 murine bladder tumors, as compared to vaccination alone. As known TAA are not identified in all cancers, or not expressed in all stages of the tumor, we further investigated two potent approaches able of initiating tumor-cell destruction, suicide-gene therapy and near-infrared (NIR) photodynamic therapy (PDT). Towards a safe and non-toxic application of these therapies, we used Human Papillomavirus (HPV) replication-defective vectors that were able to preferentially pseudo-infect MB49-tumor bearing mice. HPV pseudovirions (PsV) carrying the Herpex-Simplex virus thymidine kinase suicide-gene followed by treatment with the prodrug Ganciclovir resulted in 90% of MB49 cell-death in-vitro and was able to significantly reduce bladder tumor growth in-vivo. Furthermore, HPV virus-like particles coupled to a NIR phtalocyanine dye, IR700 in combination with specific NIR light led to almost 100% of MB49 cell-death in-vitro and more interestingly, to bladder tumors shrinkage in-vivo. Overall, in this thesis, we offer promising therapeutic approaches for application in NMIBC patients.
Resumo:
Background:Microcystic macular edema can occur after optic neuropathies of various etiologies, and is easily demonstrated by OCT. We report a cohort of patients with microcystic macular edema. Patients and Methods: All patients with optic neuropathy and microcystic macular edema were enrolled. Demographics, visual function, retinal angiographies and OCT parameters were studied. Results: Nineteen patients (23 eyes) exhibited microcystic macular edema: 10 men/9 women, aged 17-91 years. Etiologies of optic nerve atrophy were compressive (5), inflammatory (4), glaucoma (3), ischemic (3), trauma (2), degenerative (1), and hereditary (1). Median visual acuity was 4/10 (NLP-12/10). Fluorescein angiography showed no leakage. Topography of the microcystic macular edema correlated with near infrared images but with visual field defects in only 26 %. OCT parameters were all abnormal. Conclusions: Microcystic macular edema is a non-specific manifestation from an optic neuropathy of any etiology. The precise mechanism leading to microcystic macular edema remains unknown but trans-synaptic retrograde degeneration with Müller cells dysfunction is likely. Zusammenfassung Hintergrund: Das mikrozystische Makulaödem kann im Rahmen einer Optikusatrophie jeglicher Ätiologie auftreten und ist leicht mit dem OCT zu erkennen. Wir berichten über eine Patientenkohorte mit mikrozystischem Makulaödem. Patienten und Methoden: Alle Patienten mit einer Optikusneuropathie und einem mikrozystischen Makulaödem wurden in diese Studie eingeschlossen. Die Demografie, die Sehfunktion, die Netzhautangiografie und die OCT-Parameter wurden untersucht. Ergebnisse: Neunzehn Patienten (23 Augen) hatten ein mikrozystisches Makulaödem: 10 Männer/9 Frauen im Alter von 17 bis 91 Jahren. Die Ursachen der Optikusatrophie waren Kompressionen (5), Entzündungen (4), Glaukom (3), Ischämien (3), Traumata (2), Degenerationen (1) und genetisch (1). Der mittlere Visus war 0,4 (keine Lichtwahrnehmung 1,2). In der Fluoreszenzangiografie fand sich keine Leckage. Das OCT des mikrozystischen Makulaödems korrelierte immer mit den Infrarot-Bildern (Nahaufnahme), jedoch nur in 26 % mit den Gesichtsfelddefekten. Alle OCT-Parameter waren abnormal. Schlussfolgerungen: Das mikrozystische Makulaödem ist eine unspezifische Manifestation einer Optikusneuropathie jeglicher Ätiologie. Der genaue Mechanismus, der zu einem mikrozystischen Makulaödem führt, ist unbekannt, eine trans-synaptische retrograde Degeneration mit Dysfunktion der Müller-Zellen ist jedoch wahrscheinlich.
Resumo:
The modern generation of Cherenkov telescopes has revealed a new population of gamma-ray sources in the Galaxy. Some of them have been identified with previously known X-ray binary systems while other remain without clear counterparts a lower energies. Our initial goal here was reporting on extensive radio observations of the first extended and yet unidentified source, namely TeV J2032+4130. This object was originally detected by the HEGRA telescope in the direction of the Cygnus OB2 region and its nature has been a matter of debate during the latest years. The situation has become more complex with the Whipple and MILAGRO telescopes new TeV detections in the same field which could be consistent with the historic HEGRA source, although a different origin cannot be ruled out. Aims.We aim to pursue our radio exploration of the TeV J2032+4130 position that we initiated in a previous paper but taking now into account the latest results from new Whipple and MILAGRO TeV telescopes. The data presented here are an extended follow up of our previous work. Methods.Our investigation is mostly based on interferometric radio observations with the Giant Metre Wave Radio Telescope (GMRT) close to Pune (India) and the Very Large Array (VLA) in New Mexico (USA). We also conducted near infrared observations with the 3.5 m telescope and the OMEGA2000 camera at the Centro Astronómico Hispano Alemán (CAHA) in AlmerÃa (Spain). Results.We present deep radio maps centered on the TeV J2032+4130 position at different wavelengths. In particular, our 49 and 20 cm maps cover a field of view larger than half a degree that fully includes the Whipple position and the peak of MILAGRO emission. Our most important result here is a catalogue of 153 radio sources detected at 49 cm within the GMRT antennae primary beam with a full width half maximum (FWHM) of 43 arc-minute. Among them, peculiar sources inside the Whipple error ellipse are discussed in detail, including a likely double-double radio galaxy and a one-sided jet source of possible blazar nature. This last object adds another alternative counterpart possibility to be considered for both the HEGRA, Whipple and MILAGRO emission. Moreover, our multi-configuration VLA images reveal the non-thermal extended emission previously reported by us with improved angular resolution. Its non-thermal spectral index is also confirmed thanks to matching beam observations at the 20 and 6 cm wavelengths.
Resumo:
This study shows how a new generation of terrestrial laser scanners can be used to investigate glacier surface ablation and other elements of glacial hydrodynamics at exceptionally high spatial and temporal resolution. The study area is an Alpine valley glacier, Haut Glacier d'Arolla, Switzerland. Here we use an ultra-long-range lidar RIEGL VZ-6000 scanner, having a laser specifically designed for measurement of snow- and ice-cover surfaces. We focus on two timescales: seasonal and daily. Our results show that a near-infrared scanning laser system can provide high-precision elevation change and ablation data from long ranges, and over relatively large sections of the glacier surface. We use it to quantify spatial variations in the patterns of surface melt at the seasonal scale, as controlled by both aspect and differential debris cover. At the daily scale, we quantify the effects of ogive-related differences in ice surface debris content on spatial patterns of ablation. Daily scale measurements point to possible hydraulic jacking of the glacier associated with short-term water pressure rises. This latter demonstration shows that this type of lidar may be used to address subglacial hydrologic questions, in addition to motion and ablation measurements.