924 resultados para mulleri subgroup
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Using ELISA technique, natural antibodies against self and non self antigens were determined in 80 patients chronically intected by T. cruzi and 40 individuals suffering from a deep mycosis frequentely found in Latin Amarica (Paracoccidioidomycosis - PCM). Two forms of PCM were investigated: adult forms and juvenil type of disease. Eighty percent (80%) of the former group had significantly elevated anti-laminin antibody levels (M=4.7,SD±1.8) compared with healthy controls and different specificities of antibody were associated with anti-laminin in pathological sera. A notable binding to cytoskeletal proteins was observed, specially with band 3 and their peptides derivates, such as 62 kDa peptide. By means of Protein A chromatography we were able to show that natural anti-Gal antibodies may be bound by their Fab region to other immunoglobulins and/or to Protein A by alternative sites of binding. The finding of lgG anti-Gal antibodies in circulating immune complexes isolated from chagasic sera supported the first alternative. However, it is possible that some of lgG anti-Gal antibodies, belong to VH111 subgroup of immunoglobulins, that bind directly to Protein A. Among the 40 sera from PCM examined, the majority was considered as not exhibiting a signilicantly higher binding than normal sera to antigens tested. However thirty percent (30%) of the chronic patients had an increased levels of natural antibodies at least for one specificity such as actyn, myosin and Gala1,3Gal epitopes. ln juvenil type of PCM the mean value found for actyn was also increased 2,42 (range 1,0 to 5,3). Utilizing the polyethylene glicol precipitation the presence of circulating immune complexes was investigated in PCM sera. Specific antibodies for soluble antigens from P. brasiliensis and natural antibodies against myoglobin, myosin and Gala1,3 Gal epitopes were characterized
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Física - FEG
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This prospective study analyzed the frequency of HLA-B27 and its alleles in 102 Brazilian patients with psoriatic arthritis (PsA). The association of the HLA-B27 alleles with these variants was compared to a control healthy HLA-B27 positive group of 111 individuals. There was a predominance of male gender (59.8%), Caucasian race (89.2%), and negative HLA-B27 (79.4%) patients. Asymmetric oligoarthritis (62.7%) was the most frequently observed clinical PsA subgroup, followed by spondylitis (16.7%), and polyarthritis (15.7%). Male gender and the spondylitis subgroup were statistically associated to the positive HLA-B27, and the oligoarthritis subgroup was associated to the negative HLA-B27. Among the 21 HLA-B27-positive PsA patients, there was a significant prevalence of the HLA-B*2705 allele (90.5%), similar to that observed in the control group (80.2%); HLA-B*2703 and HLA-B*2707 were statistically associated to the control group.
Resumo:
The aim of the present study was to evaluate the microtensile bond strength to dentin (ATBS) of two total-etching adhesives applied with delays of 1-30 s for curing. Fifty extracted molar teeth were used. Occlusal enamel was sectioned to expose flat dentin surface, which was further polished with 600-grit paper for smear layer standardization. The specimens were divided into two groups, G1: Single Bond total-etching adhesive (SB), and G2: Prime & Bond NT total-etching adhesive (PB). Each group was further divided into 5 subgroups according to the delayed light-cure initiation after the adhesive systems application (n=5): Subgroup 1s - 1 s; Subgroup 5s -5 s; Subgroup 10s - 10 s; Subgroup 20s - 20 s; Subgroup 30s - 30 s. Composite resin cones 5 mm height and 10 mm in diameter were fabricated. Specimens were stored in distilled water at 37 degrees C for 24 h and sectioned to obtain 1 x 1 mm(2) transversal specimens. Specimens were thermocycled and mu TBS was measured. Data were submitted to two-way ANOVA (AdhesiveXDelay time) and Tukey's test. The level of significance was set at 5%. The results in mean MPa(+/- SD) for interaction between adhesive and delay time were: PB/1s - 23.82 +/- 2.54a; SB/5s - 19.52 +/- 2.67b; PB/5s - 18.56 +/- 3.06bc; SB/1s - 15.49 +/- 2.69cd; SB/20s - 16.33 +/- 2.55d; SB/10s - 13.88 +/- 1.67d; PB/10s - 11.04 +/- 1.28e; PB/30s - 10.89 +/- 1.31e; PB/20s - 10.24 +/- 2.33e; SB/30s - 9.19 +/- 1.91e. It was concluded that light-cure initiation timing of total-etching adhesives interferes negatively with mu TBS to dentin. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The growing interest in the use of groundwater resources is directly related to the economic advantages that the groundwater exploitation offers when compared to surface waters. This happens especially in large urban centers, such as the city of Americana / SP, where the rivers are increasingly contaminated by household and industrial waste. Therefore, this study aimed to characterize the Tubarão Aquifer System, in the city of Americana, to identify and evaluate the spatial distribution of different hydrogeochemical facies as well as understand the rock-fluid interaction through the construction of a conceptual hydrogeochemical model. This study was made based on the recognition of the possible chemical reactions that print the chemical characteristics of groundwater in the area. To do the job, there were two water sampling campaigns of all deep wells used by the City of Americana public water supply. From the results of hydrochemical, classification of water was made by Piper and Stiff diagrams as well as geostatistical data using cluster analysis of principal components. Based on information from the profiles obtained from the survey SIAGAS as well as in geological profiles provided by the city of Americana, we sought to detail the subsurface geology of the Subgroup Itararé in the city of Americana. The results obtained allowed the identification of three hydrochemical types in the study area: Bicarbonated calcium-sodium (1), bicarbonate sodium (2) and sodium chloride (3). The waters have bicarbonate alkaline pH to alkaline and can be considered weakly saline, with electrical conductivity values of around 161 mS / cm. Samples classified as sodium bicarbonate average of 174.99 mS / cm. The pH values ranging from 6.74 to 7.99, averaging 7.52. For the group of waters classified as sodium chloride, conductivity average is 164.32 mS / cm and pH values ranging... (Complete abstract click electronic access below)
Resumo:
To evaluate the effect of surface treatment with Er:YAG and Nd:YAG laser on resin composite bond strength to recently bleached dentin. Material and Methods: In this study 120 bovine incisors were used and distributed into two groups: Group C: without bleaching treatment; Group B: with bleaching treatment (35% hydrogen peroxide). Each group was divided into three subgroups: Subgroup N: without laser treatment; Subgroup Nd: irradiation with Nd:YAG laser; Subgroup Er: irradiation with Er:YAG laser. Next, the adhesive system (Adper Single Bond 2) was applied and composite buildups were constructed with Z350 composite. The teeth were sectioned to obtain dentin-resin sticks (1x1mm) and analyzed by microtensile bond testing. The data were statistically analyzed by the ANOVA and Tukey tests. Results: The results showed that the bond strength values in the bleached control group (16.17 MPa) presented no significant difference in comparison with the group bleached and irradiated with Er:YAG laser (14.69 MPa). The non bleached control group (26.79 MPa) presented significant difference in bond strength when compared with the non bleached group irradiated with Er:YAG laser (22.82 MPa) and with the group treated by bleaching and irradiation with Nd:YAG laser (28,792 MPa). The group without bleaching treatment and irradiated with Nd:YAG (36.1 MPa) presented a significant increase in bond strength in comparison with the other groups. Conclusion: The use of Nd:YAG laser on bleached specimens was able of completely reversing the immediate effects of bleaching, obtaining bond strength values similar to those of the control group