999 resultados para laser, fibre, ottiche, moduli, connettori, lenti


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fiber recovery process is an essential part of the modern paper mill. It creates the basisfor mill's internal recirculation of the most important raw materials ¿ water and fiber. It is normally also a start point for further treatment of wastewater and if it works efficiently, it offers excellent basis to minimize effluents. This dissertation offers two different approaches to the subject. Firstly a novel save-all disc filter feeding system is developed and presented. This so-called precoat method is tested both in the laboratory and full-scale conditions. In laboratory scale it beats the traditional one clearly, when low freeness pulps are used as a sweetener stock. The full-scale application needs still some development work before it can be implemented to the paper mills. Secondly, the operationenvironment of save-all disc filter is studied mostly in laboratory conditions.The focus of this study is in cases, where low-freeness pulps are used as a sweetener stock of save-all filter. The effects of CSF-value, pressure drop, suspension consistency and retention chemicals to the quantity and quality of the filtrate was studied. Also the filtration resistance of the low freeness pulps was one studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research has been focused at the development of a tuned systematic design methodology, which gives the best performance in a computer aided environment and utilises a cross-technological approach, specially tested with and for laser processed microwave mechanics. A tuned design process scheme is also presented. Because of the currently large production volumes of microwave and radio frequency mechanics even slight improvements of design methodologies or manufacturing technologies would give reasonable possibilities for cost reduction. The typical number of required iteration cycles could be reduced to one fifth of normal. The research area dealing with the methodologies is divided firstly into a function-oriented, a performance-oriented or a manufacturability-oriented product design. Alternatively various approaches can be developed for a customer-oriented, a quality-oriented, a cost-oriented or an organisation-oriented design. However, the real need for improvements is between these two extremes. This means that the effective methodology for the designers should not be too limited (like in the performance-oriented design) or too general (like in the organisation-oriented design), but it should, include the context of the design environment. This is the area where the current research is focused. To test the developed tuned design methodology for laser processing (TDMLP) and the tuned optimising algorithm for laser processing (TOLP), seven different industrial product applications for microwave mechanics have been designed, CAD-modelled and manufactured by using laser in small production series. To verify that the performance of these products meets the required level and to ensure the objectiveness ofthe results extensive laboratory tests were used for all designed prototypes. As an example a Ku-band horn antenna can be laser processed from steel in 2 minutes at the same time obtaining a comparable electrical performance of classical aluminium units or the residual resistance of a laser joint in steel could be limited to 72 milliohmia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a mesurement system designed to register the displacement of the legs using a two-dimensional laser range sensor with a scanning plane parallel to the ground and extract gait parameters. In the proposed methodology, the position of the legs is estimated by fitting two circles with the laser points that define their contour and the gait parameters are extracted applying a step-line model to the estimated displacement of the legs to reduce uncertainty in the determination of the stand and swing phase of the gait. Results obtained in a range up to 8 m shows that the systematic error in the location of one static leg is lower than 10 mm with and standard deviation lower than 8 mm; this deviation increases to 11 mm in the case of a moving leg. The proposed measurement system has been applied to estimate the gait parameters of six volunteers in a preliminary walking experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimization of most pesticide and fertilizer applications is based on overall grove conditions. In this work we measurements. Recently, Wei [9, 10] used a terrestrial propose a measurement system based on a ground laser scanner to LIDAR to measure tree height, width and volume developing estimate the volume of the trees and then extrapolate their foliage a set of experiments to evaluate the repeatability and surface in real-time. Tests with pear trees demonstrated that the accuracy of the measurements, obtaining a coefficient of relation between the volume and the foliage can be interpreted as variation of 5.4% and a relative error of 4.4% in the linear with a coefficient of correlation (R) of 0.81 and the foliar estimation of the volume but without real-time capabilities. surface can be estimated with an average error less than 5 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The geometric characterisation of tree orchards is a high-precision activity comprising the accurate measurement and knowledge of the geometry and structure of the trees. Different types of sensors can be used to perform this characterisation. In this work a terrestrial LIDAR sensor (SICK LMS200) whose emission source was a 905-nm pulsed laser diode was used. Given the known dimensions of the laser beam cross-section (with diameters ranging from 12 mm at the point of emission to 47.2 mm at a distance of 8 m), and the known dimensions of the elements that make up the crops under study (flowers, leaves, fruits, branches, trunks), it was anticipated that, for much of the time, the laser beam would only partially hit a foreground target/object, with the consequent problem of mixed pixels or edge effects. Understanding what happens in such situations was the principal objective of this work. With this in mind, a series of tests were set up to determine the geometry of the emitted beam and to determine the response of the sensor to different beam blockage scenarios. The main conclusions that were drawn from the results obtained were: (i) in a partial beam blockage scenario, the distance value given by the sensor depends more on the blocked radiant power than on the blocked surface area; (ii) there is an area that influences the measurements obtained that is dependent on the percentage of blockage and which ranges from 1.5 to 2.5 m with respect to the foreground target/object. If the laser beam impacts on a second target/object located within this range, this will affect the measurement given by the sensor. To interpret the information obtained from the point clouds provided by the LIDAR sensors, such as the volume occupied and the enclosing area, it is necessary to know the resolution and the process for obtaining this mesh of points and also to be aware of the problem associated with mixed pixels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Proliferative retinopathy is an important cause of vision loss in diabetic patients. Incomplete panretinal photocoagulation (PRP) can lead to recurrent proliferation of new vessels. Patients and Methods: We retrospectively analysed the outcome of patients with high risk proliferative diabetic retinopathy (PDR) previously treated with slit lamp PRP who underwent indirect fill in argon laser treatment with scleral indentation under anesthesia for persistent neovascular proliferation. Results: Seventeen eyes of ten patients were included. The mean age at diabetes onset was 17.3 years SD 16.2 (range 2-44). All patients reported long standing poor glycemic control (mean HbA1c: 8.5 % SD 1.3 range 5.9-10.2). The area of retinal ischemia decreased significantly from 15 ± 7.5 disk areas (DA) before fill-in laser to 3.2 ± 4.2 DA after fill-in laser (p = 0.001). The new vessels also regressed significantly after laser treatment 8.6 ± 6.1 DA before treatment versus 6.5 ± 6.4 DA after laser treatment, (p = 0.044). Quiescent PDR was reached in 10 eyes (58.8 %) at the last visit. Conclusions: Fill-in indirect argon laser under general anesthesia should be considered to achieve further new vessels regression in high risk PDR patients. Scleral indentation and absence of pain may allow for more extensive laser application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibre-reinforced composite (FRC) root canal posts are suggested to have biomechanical benefits over traditional metallic posts, but they lack good adhesion to resin composites. The aim of this series of studies was to evaluate the adhesion of individually formed fibre-reinforced composite material to composite resin and dentin, as well as some mechanical properties. Flexural properties were evaluated and compared between individually formed FRC post material and different prefabricated posts. The depth of polymerization of the individually formed FRC post material was evaluated with IR spectrophotometry and microhardness measurements, and compared to that of resin without fibres. Bonding properties of the individually formed FRC post to resin cements and dentin were tested using Pull-out- and Push-out-force tests, evaluated with scanning electron microscopy, and compared to those of prefabricated FRC and metal posts. Load-bearing capacity and microstrain were evaluated and failure mode assessment was made on incisors restored with individually formed FRC posts of different structures and prefabricated posts. The results of these studies show that the individually polymerized and formed FRC post material had higher flexural properties compared to the commercial prefabricated FRC posts. The individually polymerized FRC material showed almost the same degree of conversion after light polymerization as monomer resin without fibres. Moreover, it was found that the individually formed FRC post material with a semiinterpenetrating polymer network (IPN) polymer matrix bonded better to composite resin luting cement, than did the prefabricated posts with a cross-linked polymer matrix. Furthermore, it was found that, contrary to the other posts, there were no adhesive failures between the individually formed FRC posts and composite resin luting cement. This suggests better interfacial adhesion of cements to these posts. Although no differences in load-bearing capacity or microstrain could be seen, the incisors restored with individually formed FRC posts with a hollow structure showed more favourable failures compared to other prefabricated posts. These studies suggest that it is possible to use individually formed FRC material with semi-IPN polymer matrix as root canal post material. They also indicate that there are benefits especially regarding the bonding properties to composite resin and dentin with this material compared to prefabricated FRC post material with a cross-linked matrix. Furthermore, clinically more repairable failures were found with this material compared to those of prefabricated posts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Pellavan ja kuituhampun mikrobiologinen laatu kasvukauden aikana

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Acute painful diabetic neuropathy (APDN) is a distinctive diabetic polyneuropathy and consists of two subtypes: treatment-induced neuropathy (TIN) and diabetic neuropathic cachexia (DNC). The characteristics of APDN are (1.) the small-fibre involvement, (2.) occurrence paradoxically after short-term achievement of good glycaemia control, (3.) intense pain sensation and (4.) eventual recovery. In the face of current recommendations to achieve quickly glycaemic targets, it appears necessary to recognise and understand this neuropathy. METHODS AND RESULTS: Over 2009 to 2012, we reported four cases of APDN. Four patients (three males and one female) were identified and had a mean age at onset of TIN of 47.7 years (±6.99 years). Mean baseline HbA1c was 14.2% (±1.42) and 7.0% (±3.60) after treatment. Mean estimated time to correct HbA1c was 4.5 months (±3.82 months). Three patients presented with a mean time to symptom resolution of 12.7 months (±1.15 months). One patient had an initial normal electroneuromyogram (ENMG) despite the presence of neuropathic symptoms, and a second abnormal ENMG showing axonal and myelin neuropathy. One patient had a peroneal nerve biopsy showing loss of large myelinated fibres as well as unmyelinated fibres, and signs of microangiopathy. CONCLUSIONS: According to the current recommendations of promptly achieving glycaemic targets, it appears necessary to recognise and understand this neuropathy. Based on our observations and data from the literature we propose an algorithmic approach for differential diagnosis and therapeutic management of APDN patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän diplomityön tarkoituksena oli karakterisoida kuluttajapakkauskartonkien laserleikattavuutta. Kirjallisuusosassa perehdyttiin asiaa käsittelevään kirjallisuuteen ja tutkimuksiin ja kokeellisessa osassa käsiteltiin kuitumateriaalien laserleikkausta erilaisin leikkausparametrein. Leikattujen näytteiden leikkausrailosta otetuista mikroskooppikuvista määritettiin leikkausrailon uraleveys, purseen ja mustumisen määrä. Työssä tutkitut materiaalit olivat koivu- ja mäntysellu, CTMP, päällystämätön ja päällystetty sellukartonki sekä päällystämätön CTMP-runkoinen nestepakkauskartonki. Työssä havaittiin, että tutkitut kuitumateriaalit soveltuivat erinomaisesti laserleikkaukseen. Leikattujen kuitumateriaalinäytteiden leikkausrailo oli hyvälaatuinen eli leikkausrailo oli kapea, täydellisesti näytteen lävitse, tasainen reunoiltaan, väriltään vaalea ( ei hiiltynyt ) ja ei sisältänyt railon reunassa pystyssä olevia katkenneita kuituja ( pursetta ). Työssä todettiin myös, että kuitumateriaaleja laserleikatessa leikkausnopeus ja laserteho riippuivat lineaarisesti toisistaan. Leikkausnopeuden kasvaessa tarvittiin enemmän lasertehoa hyvälaatuisen leikkausrailon saavuttamiseksi. Tällöin leikkausuran leveys pysyi lähes vakiona. Lisäksi huomattiin, että optimisijainti polttopisteelle olisi 0.1-0.4 mm materiaalin pinnan yläpuolella, vaikka kirjallisuudesta löydettiin suosituksia sijoittaa polttopiste materiaalin pinnan alapuolelle. Näillä polttopisteen sijainnin arvoilla saavutettiin suurimmat leikkausnopeudet ja kapeimmat urat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Päällystettyä paperia valmistettaessa syntyy päällystettyä hylkyä, joka kierrätetään takaisin prosessiin raaka-aineen tehokkaaksi hyödyntämiseksi. Hylyn mukana takaisin paperikoneen lyhyeen kiertoon päätyy myös pigmenttiaines levymäisinä partikkeleina. Nämä partikkelit rejektoituvat lyhyen kierron pyörrepuhdistimilla. Raaka-aineen hävikin pienentämiseksi käytetään lyhyessä kierrossa täyteaineen talteenottojärjestelmää, jonka tehtävänä on hienontaa päällystysainepartikkelit tasakokoisiksi, jotta ne voitaisiin palauttaa prosessiin. Talteenottolaitteistojen toiminnan tarkkailun kannalta on keskeistä tietää pyörrepuhdistuslaitoksen eri jakeiden partikkelikokojakaumat juuri pigmenttipartikkelien osalta. Tätä määritystä häiritsee näytteissä oleva kuitu. Tässä työssä pyrittiin löytämään partikkelikokoanalyysimenetelmä, jolla pigmenttien partikkelikokojakauma saataisiin selvitettyä kuidusta huolimatta. Aiemmin käytetty näytteen tuhkaus esikäsittelynä ennen partikkelikokoanalyysiä laserdiffraktiometrillä on osoittautunut toimimattomaksi. Kokeiden pääpaino keskittyi näytteen esikäsittelyyn fraktioinnilla ennen laserdiffraktioanalyysiä ja virtaussytometriamittauksiin. Fraktiointiin käytettiin DDJ-laitetta (dynamic drainage jar), joka oli varustettu metalliviiralla. Kumpikaan menetelmistä ei ollut täysin toimiva partikkelikokoanalyysiin, fraktioinnilla saadaan vähennettyä kuidun partikkelikokojakaumaan aiheuttamaa virhettä, mutta sen toimivuus riippuu paljolti näytteestä. Virtaussytometrialla väriainetta SYTO13 käyttämällä saadaan pigmenttipartikkelit tunnistettua ja näin rajattua kuidut pois mittauksista, mutta pigmenttiä ei saada erotettua puuperäisestä hienoaineesta, mikä vääristää mittaustulosta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raaka-aineen hiukkaskoko on lääkekehityksessä keskeinen materiaaliparametri. Lääkeaineen partikkelikoko vaikuttaa moneen lääketuotteen tärkeään ominaisuuteen, esimerkiksi lääkkeen biologiseen hyväksikäytettävyyteen. Tässä diplomityössä keskityttiin jauhemaisten lääkeaineiden hiukkaskoon määrittämiseen laserdiffraktiomenetelmällä. Menetelmä perustuu siihen, että partikkeleista sironneen valon intensiteetin sirontakulmajakauma on riippuvainen partikkelien kokojakaumasta. Työn kirjallisuusosassa esiteltiin laserdiffraktiomenetelmän teoriaa. PIDS (Polarization Intensity Differential Scattering) tekniikka, jota voidaan käyttää laserdiffraktion yhteydessä, on myös kuvattu kirjallisuusosassa. Muihin menetelmiin perustuvista analyysimenetelmistä tutustuttiin mikroskopiaan sekä aerodynaamisen lentoajan määrittämiseen perustuvaan menetelmään. Kirjallisuusosassa esiteltiin myös partikkelikoon yleisimpiä esitystapoja. Työn kokeellisen osan tarkoituksena oli kehittää ja validoida laserdiffraktioon perustuva partikkelikoon määritysmenetelmä tietylle lääkeaineelle. Menetelmäkehitys tehtiin käyttäen Beckman Coulter LS 13 320 laserdiffraktoria. Laite mahdollistaa PIDS-tekniikan käytön laserdiffraktiotekniikan ohella. Menetelmäkehitys aloitettiin arvioimalla, että kyseinen lääkeaine soveltuu parhaiten määritettäväksi nesteeseen dispergoituna. Liukoisuuden perusteella väliaineeksi valittiin tällä lääkeaineella kyllästetty vesiliuos. Dispergointiaineen sekä ultraäänihauteen käyttö havaittiin tarpeelliseksi dispergoidessa kyseistä lääkeainetta kylläiseen vesiliuokseen. Lopuksi sekoitusnopeus näytteensyöttöyksikössä säädettiin sopivaksi. Validointivaiheessa kehitetyn menetelmän todettiin soveltuvan hyvin kyseiselle lääkeaineelle ja tulosten todettiin olevan oikeellisia sekä toistettavia. Menetelmä ei myöskään ollut herkkä pienille häiriöille.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a novel formulation to solve the problem of intra-voxel reconstruction of the fibre orientation distribution function (FOD) in each voxel of the white matter of the brain from diffusion MRI data. The majority of the state-of-the-art methods in the field perform the reconstruction on a voxel-by-voxel level, promoting sparsity of the orientation distribution. Recent methods have proposed a global denoising of the diffusion data using spatial information prior to reconstruction, while others promote spatial regularisation through an additional empirical prior on the diffusion image at each q-space point. Our approach reconciles voxelwise sparsity and spatial regularisation and defines a spatially structured FOD sparsity prior, where the structure originates from the spatial coherence of the fibre orientation between neighbour voxels. The method is shown, through both simulated and real data, to enable accurate FOD reconstruction from a much lower number of q-space samples than the state of the art, typically 15 samples, even for quite adverse noise conditions.