869 resultados para hip dislocation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nursing Case Management has motivated nurses to examine the effects of care provided to patients, and to devise means of improving this care. The success of this nursing care delivery model is well documented among a variety of acute and chronically ill patients. Utilizing nonparametric ANOVA for comparison of two means, this study investigates the outcome of the implementation of a nursingcase management model on an orthopedic unit of a local hospital. A convenience sample (N=149) of hip-fracture patients for two separate eight months charting periods were used. The first period was pre-case management and the second period was after the implementation of nursing managed care on the unit. Results suggested that nursing case management was effective in reducing the total length of hospital stay and post-operative days significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the incidence of corrosion and fretting in 48 retrieved titanium-6aluminum-4vanadium and/or cobalt-chromium-molybdenum modular total hip prosthesis with respect to alloy material microstructure and design parameters. The results revealed vastly different performance results for the wide array of microstructures examined. Severe corrosion/fretting was seen in 100% of as-cast, 24% of low carbon wrought, 9% of high carbon wrought and 5% of solution heat treated cobalt-chrome. Severe corrosion/fretting was observed in 60% of Ti-6Al-4V components. Design features which allow for fluid entry and stagnation, amplification of contact pressure and/or increased micromotion were also shown to play a role. 75% of prosthesis with high femoral head-trunnion offset exhibited poor performance compared to 15% with a low offset. Large femoral heads (>32mm) did not exhibit poor corrosion or fretting. Implantation time was not sufficient to cause poor performance; 54% of prosthesis with greater than 10 years in-vivo demonstrated none or mild corrosion/fretting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Discussion moderated by CRI visiting scholar Noram Gamez Torres discussing the future of Cuban hip-hop, its racial politics, and the impact that the cultural exchange policy has had on these rappers and their music. Includes performances and discussion by artists Aldo Baquero (Los Aldeanos), Raudel Collazo (Escuadr6n Patriota), David Escalona (Omni Zona Franca), and Silvio Rodriguez (Silvito "EI Libre").

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudo sobre o Hip Hop como processo comunicacional e sociabilidade entre jovens indígenas de Dourados, Mato Grosso do Sul, para verificar quais os principais objetivos da prática do movimento Hip Hop, compreender se serve como comunicação, contribui para o fortalecimento da língua guarani ou gera novas tensões sociais na reserva. Para tanto, foi analisado aspectos históricos do movimento, passando pelos Estudos Culturais, e como Movimento Social, dando início à discussão de uma voz alternativa por meio do Hip Hop. Do ponto de vista metodológico, trata-se de um de estudo de caso, com representantes dos grupos de jovens Brô Mc's e Jovens Conscientes, das reservas Jaguapirú e Bororó, das etnias Guarani-Kaiowá de Dourados (MS). Foram realizadas entrevistas semiestruturadas junto a jovens que participaram das oficinas de hip hop, das lideranças indígenas e professores. A investigação é complementada pela pesquisa bibliográfica, documental e análises das letras de rap em confrontação com as visões da imprensa, a partir da análise dos jornais Diário MS e O Progresso. Os resultados apontam que os jovens se apropriam de uma cultura global para transformar o ambiente local com objetivo de preservar a língua guarani, uma alternativa para o conhecimento, logo para não seguirem caminhos como o das drogas. Negociando falas sobre sua realidade, dentro e fora da reserva, já que nos meios de comunicação locais há pouco espaço para a voz dos indígenas e dentro da reserva ainda há contestação do movimento em um contexto político, na tentativa de atingir uma cultura “pura”, devido à preocupação dos mais velhos com a perda de território.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Funding was provided in part by the US National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS) K23 AR061406 (Nelson); US National Institutes of Health (NIH)/NIAMS P60AR30701 (Jordan/Renner/Schwartz); US Centers for Disease Control/Association of Schools of Public Health S043 and S3486 (Jordan/Renner); K24-AR04884, P50-AR063043, and P50-AR060752 (Lane); and NIH/National Center for Advancing Translational Sciences KL2TR001109 (Golightly).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Funding was provided in part by the US National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS) K23 AR061406 (Nelson); US National Institutes of Health (NIH)/NIAMS P60AR30701 (Jordan/Renner/Schwartz); US Centers for Disease Control/Association of Schools of Public Health S043 and S3486 (Jordan/Renner); K24-AR04884, P50-AR063043, and P50-AR060752 (Lane); and NIH/National Center for Advancing Translational Sciences KL2TR001109 (Golightly).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grant support This study was supported by an award (Ref: WHMSB-AU119) from the Translational Medicine Research Collaboration – a consortium made up of the Universities of Aberdeen, Dundee, Edinburgh and Glasgow, the four associated NHS Health Boards (Grampian, Tayside, Lothian and Greater Glasgow & Clyde), Scottish Enterprise and Wyeth. The funder played no part in the design, execution, analysis or publication of this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peer reviewed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dynamical evolution of dislocations in plastically deformed metals is controlled by both deterministic factors arising out of applied loads and stochastic effects appearing due to fluctuations of internal stress. Such type of stochastic dislocation processes and the associated spatially inhomogeneous modes lead to randomness in the observed deformation structure. Previous studies have analyzed the role of randomness in such textural evolution but none of these models have considered the impact of a finite decay time (all previous models assumed instantaneous relaxation which is "unphysical") of the stochastic perturbations in the overall dynamics of the system. The present article bridges this knowledge gap by introducing a colored noise in the form of an Ornstein-Uhlenbeck noise in the analysis of a class of linear and nonlinear Wiener and Ornstein-Uhlenbeck processes that these structural dislocation dynamics could be mapped on to. Based on an analysis of the relevant Fokker-Planck model, our results show that linear Wiener processes remain unaffected by the second time scale in the problem but all nonlinear processes, both Wiener type and Ornstein-Uhlenbeck type, scale as a function of the noise decay time τ. The results are expected to ramify existing experimental observations and inspire new numerical and laboratory tests to gain further insight into the competition between deterministic and random effects in modeling plastically deformed samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of joint kinematics can provide knowledge to help improve joint prosthesis design, as well as identify joint motion patterns that may lead to joint degeneration or injury. More investigation into how the hip translates in live human subjects during high amplitude motions is needed. This work presents a design of a non-invasive method using the registration between images from conventional Magnetic Resonance Imaging (MRI) and open MRI to calculate three dimensional hip joint kinematics. The method was tested on a single healthy subject in three different poses. MRI protocols for the conventional gantry, high-resolution MRI and the open gantry, lowresolution MRI were developed. The scan time for the low-resolution protocol was just under 6 minutes. High-resolution meshes and low resolution contours were derived from segmentation of the high-resolution and low-resolution images, respectively. Low-resolution contours described the poses as scanned, whereas the meshes described the bones’ geometries. The meshes and contours were registered to each other, and joint kinematics were calculated. The segmentation and registration were performed for both cortical and sub-cortical bone surfaces. A repeatability study was performed by comparing the kinematic results derived from three users’ segmentations of the sub-cortical bone surfaces from a low-resolution scan. The root mean squared error of all registrations was below 1.92mm. The maximum range between segmenters in translation magnitude was 0.95mm, and the maximum deviation from the average of all orientations was 1.27◦. This work demonstrated that this method for non-invasive measurement of hip kinematics is promising for measuring high-range-of-motion hip motions in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La sostituzione totale d’anca è uno degli interventi chirurgici con le più alte percentuali di successo. Esistono due varianti di protesi d’anca che differiscono in base al metodo di ancoraggio all’osso: cementate (fissaggio tramite cemento osseo) e non cementate (fissaggio tramite forzamento). Ad oggi, i chirurghi non hanno indicazioni quantitative di supporto per la scelta fra le due tipologie di impianto, decidendo solo in base alla loro esperienza. Due delle problematiche che interessano le protesi non cementate sono la possibilità di frattura intra-operatoria durante l’inserimento forzato e il riassorbimento osseo nel periodo di tempo successivo all’intervento. A partire da rilevazioni densitometriche effettuate su immagini da TC di pazienti sottoposti a protesi d’anca non cementata, sono stati sviluppati due metodi: 1) per la valutazione del rischio di frattura intra-operatorio tramite analisi agli elementi finiti; 2) per la valutazione della variazione di densità minerale ossea (tridimensionalmente attorno alla protesi) dopo un anno dall’operazione. Un campione di 5 pazienti è stato selezionato per testare le procedure. Ciascuno dei pazienti è stato scansionato tramite TC in tre momenti differenti: una acquisita prima dell’operazione (pre-op), le altre due acquisite 24 ore (post 24h) e 1 anno dopo l’operazione (post 1y). I risultati ottenuti hanno confermato la fattibilità di entrambi i metodi, riuscendo inoltre a distinguere e a quantificare delle differenze fra i vari pazienti. La fattibilità di entrambe le metodologie suggerisce la loro possibilità di impiego in ambito clinico: 1) conoscere la stima del rischio di frattura intra-operatorio può servire come strumento di guida per il chirurgo nella scelta dell’impianto protesico ottimale; 2) conoscere la variazione di densità minerale ossea dopo un anno dall’operazione può essere utilizzato come strumento di monitoraggio post-operatorio del paziente.