894 resultados para high-performance liquid chromatography coupled with


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tiivistelmä ReferatAbstract Metabolomics is a rapidly growing research field that studies the response of biological systems to environmental factors, disease states and genetic modifications. It aims at measuring the complete set of endogenous metabolites, i.e. the metabolome, in a biological sample such as plasma or cells. Because metabolites are the intermediates and end products of biochemical reactions, metabolite compositions and metabolite levels in biological samples can provide a wealth of information on on-going processes in a living system. Due to the complexity of the metabolome, metabolomic analysis poses a challenge to analytical chemistry. Adequate sample preparation is critical to accurate and reproducible analysis, and the analytical techniques must have high resolution and sensitivity to allow detection of as many metabolites as possible. Furthermore, as the information contained in the metabolome is immense, the data set collected from metabolomic studies is very large. In order to extract the relevant information from such large data sets, efficient data processing and multivariate data analysis methods are needed. In the research presented in this thesis, metabolomics was used to study mechanisms of polymeric gene delivery to retinal pigment epithelial (RPE) cells. The aim of the study was to detect differences in metabolomic fingerprints between transfected cells and non-transfected controls, and thereafter to identify metabolites responsible for the discrimination. The plasmid pCMV-β was introduced into RPE cells using the vector polyethyleneimine (PEI). The samples were analyzed using high performance liquid chromatography (HPLC) and ultra performance liquid chromatography (UPLC) coupled to a triple quadrupole (QqQ) mass spectrometer (MS). The software MZmine was used for raw data processing and principal component analysis (PCA) was used in statistical data analysis. The results revealed differences in metabolomic fingerprints between transfected cells and non-transfected controls. However, reliable fingerprinting data could not be obtained because of low analysis repeatability. Therefore, no attempts were made to identify metabolites responsible for discrimination between sample groups. Repeatability and accuracy of analyses can be influenced by protocol optimization. However, in this study, optimization of analytical methods was hindered by the very small number of samples available for analysis. In conclusion, this study demonstrates that obtaining reliable fingerprinting data is technically demanding, and the protocols need to be thoroughly optimized in order to approach the goals of gaining information on mechanisms of gene delivery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ketoprofeeni on yleisesti käytetty ei-steroidinen tulehduskipulääke (NSAID) lampaiden ja sikojen kivunlievityksessä. Tietoa ketoprofeenin oikeista annosmääristä eri eläinlajeilla on saatavilla rajallisesti. Oikeaa lääkeainemäärää ei voida luotettavasti ekstrapoloida toisten eläinlajien tai ihmisten perusteella. Epäillyissä tulehduskipulääkemyrkytyksissä ongelmana on tietää, oliko eläimen saama lääkeannos toksinen. Lampailla tehdyn tutkimuksen tavoitteena oli selvittää, muuttuuko ketoprofeenin kinetiikka kymmenkertaisella yliannoksella, tutkia yliannoksen vaikutusta munuaisiin ja löytää yksinkertainen tapa diagnosoida yliannos virtsasta. Sioilla tehdyn tutkimuksen tavoitteena oli selvittää ketoprofeenin biologista käytettävyyttä ja ketoprofeenin farmakokinetiikkaa sioilla intravaskulaarisella, intramuskulaarisella ja peroraalisella annolla. Keskeiset tutkimuksessa määritettävät muuttujat olivat AUC0-_, Cmax ja tmax. Hyötyosuus laskettiin i.v. -annon perusteella. Kuudelle lampaalle annettiin 30 mg/kg i.v. -ketoprofeenia. Ketoprofeenin pitoisuuksia seurattiin 24 tunnin ajan plasmanäytteillä, joiden perusteella määritettiin farmakokineettiset parametrit. Veri- ja virtsanäytteistä tutkittiin muun muassa mahdollisesta munuaisvauriosta kertovia entsyymejä. 24 tunnin kuluttua lääkkeenannosta lampaat lopetettiin ja munuaiset tutkittiin histologisesti. Tutkittaville kahdeksalle sialle annosteltiin 3 mg/kg intravaskulaarista, intramuskulaarista ja oraalista ketoprofeenia sekä 6 mg/kg oraalista ketoprofeenia. Tutkimus suoritettiin satunnaistettuna vaihtovuorotutkimuksena. Ketoprofeenin pitoisuuksia seurattiin plasmanäytteillä 48 tunnin ajan lääkkeenannosta ja kaikille antotavoille laskettiin farmakokineettiset parametrit. Lisäksi tutkittiin valmisteiden biologinen samanarvoisuus. Molempien tutkimusten in vivo -kokeet suoritettiin Eläinlääketieteellisessä tiedekunnassa. Samoin munuaisten histologinen tutkimus ja virtsasta ja verestä tehdyt määritykset, lukuun ottamatta ketoprofeeninpitoisuuden analysointia. Plasman ketoprofeenipitoisuus analysoitiin korkean erotuskyvyn nestekromatografialla (HPLC). Ketoprofeenimääritykset ja farmakokineettinen analyysi suoritettiin Farmasian tiedekunnassa. Lampaiden kymmenkertainen ketoprofeeniyliannos oli toksinen. Seerumin urea- ja kreatiniinipitoisuus nousivat ja histologisissa näytteissä näkyi akuutti munuaistiehyen vaurio. Useiden entsyymien pitoisuus nousi virtsassa. Selvimmin ja nopeimmin nousi virtsan laktaattidehydrogenaasipitoisuus, jonka määrittäminen vaikuttaa potentiaaliselta tavalta diagnosoida ketoprofeenin toksinen annos. Ketoprofeenin eliminaation puoliintumisaika toksisella annoksella oli samaa suuruusluokkaa kuin aiemmissa tutkimuksissa terapeuttisella annoksella, joten yliannos ei muuttanut ketoprofeenin kinetiikkaa. AUC- ja Cmax -arvot olivat suhteessa suurempia kuin terapeuttisella annoksella, joten tutkimuksen perusteella kyseiset arvot eivät nousseet lineaarisesti annoksen noustessa toksiseksi. Sioille annetut ketoprofeenivalmisteet eivät olleet biologisesti samanarvoisia keskenään. Hyötyosuus oli erittäin hyvä kaikilla antotavoilla. tmax oli kaikilla antotavoilla hieman yli tunnin kuluttua lääkkeenannosta. Oraalisen 3 mg/kg -annoksen Cmax oli 5,1 mg/l ja AUC 32 mg l-1 h ja intramuskulaarisen vastaavat arvot olivat 7,6 mg/l ja 37 mg l-1 h. Oraalisen ketoprofeenin annostasojen AUC- ja Cmax -arvot korreloivat keskenään, joten ketoprofeenin kinetiikka oli lineaarista. Intravaskulaarisen ja oraalisen annon puoliintumisajoissa oli tilastollisesti merkitsevä ero. Ketoprofeenin jakautumistilavuudessa ja puhdistumassa ei ollut tilastollisesti merkitsevää eroa eri antotapojen välillä.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bile acids are important steroid-derived molecules essential for fat absorption in the small intestine. They are produced in the liver and secreted into the bile. Bile acids are transported by bile flow to the small intestine, where they aid the digestion of lipids. Most bile acids are reabsorbed in the small intestine and return to the liver through the portal vein. The whole recycling process is referred to as the enterohepatic circulation, during which only a small amount of bile acids are removed from the body via faeces. The enterohepatic circulation of bile acids involves the delicate coordination of a number of bile acid transporters expressed in the liver and the small intestine. Organic anion transporting polypeptide 1B1 (OATP1B1), encoded by the solute carrier organic anion transporter family, member 1B1 (SLCO1B1) gene, mediates the sodium independent hepatocellular uptake of bile acids. Two common SNPs in the SLCO1B1 gene are well known to affect the transport activity of OATP1B1. Moreover, bile acid synthesis is an important elimination route for cholesterol. Cholesterol 7α-hydroxylase (CYP7A1) is the rate-limiting enzyme of bile acid production. The aim of this thesis was to investigate the effects of SLCO1B1 polymorphism on the fasting plasma levels of individual endogenous bile acids and a bile acid synthesis marker, and the pharmacokinetics of exogenously administered ursodeoxycholic acid (UDCA). Furthermore, the effects of CYP7A1 genetic polymorphism and gender on the fasting plasma concentrations of individual endogenous bile acids and the bile acid synthesis marker were evaluated. Firstly, a high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for the determination of bile acids was developed (Study I). A retrospective study examined the effects of SLCO1B1 genetic polymorphism on the fasting plasma concentrations of individual bile acids and a bile acid synthesis marker in 65 healthy subjects (Study II). In another retrospective study with 143 healthy individuals, the effects of CYP7A1 genetic polymorphism and gender as well as SLCO1B1 polymorphism on the fasting plasma levels of individual bile acids and the bile acid synthesis marker were investigated (Study III). The effects of SLCO1B1 polymorphism on the pharmacokinetics of exogenously administered UDCA were evaluated in a prospective genotype panel study including 27 healthy volunteers (Study IV). A robust, sensitive and simple HPLC-MS/MS method was developed for the simultaneous determination of 16 individual bile acids in human plasma. The method validation parameters for all the analytes met the requirements of the FDA (Food and Drug Administration) bioanalytical guidelines. This HPLC-MS/MS method was applied in Studies II-IV. In Study II, the fasting plasma concentrations of several bile acids and the bile acid synthesis marker seemed to be affected by SLCO1B1 genetic polymorphism, but these findings were not replicated in Study III with a larger sample size. Moreover, SLCO1B1 polymorphism had no effect on the pharmacokinetic parameters of exogenously administered UDCA. Furthermore, no consistent association was observed between CYP7A1 genetic polymorphism and the fasting plasma concentrations of individual bile acids or the bile acid synthesis marker. In contrast, gender had a major effect on the fasting plasma concentrations of several bile acids and also total bile acids. In conclusion, gender, but not SLCO1B1 or CYP7A1 polymorphisms, has a major effect on the fasting plasma concentrations of individual bile acids. Moreover, the common genetic polymorphism of CYP7A1 is unlikely to influence the activity of CYP7A1 under normal physiological conditions. OATP1B1 does not play an important role in the in vivo disposition of exogenously administered UDCA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The complete amino acid sequence of two non identical subunits of the glucose/mannose-specific lectin from Dolichos lab lab (field bean) has been determined by sequential Edman analyses of the intact subunits and peptides derived by enzymatic and chemical cleavage. Peptides were purified by reverse phase high performance liquid chromatography and ion pair chromatography. The D. lab lab lectin is a glycoprotein having two polypeptide chains of 132 and 105 amino acid residues. The amino acid sequence of the D. Lab lab lectin is compared with the various lectins of the family Leguminosae. The D. lab lab lectin is the only species of the tribe Phaseoleae that contains two nonidentical subunits of almost equal size and that shows a specificity to glucose/ mannose. The lectin shows a greater homology to the glucose/mannose specific lectins, especially concanavalin A. The unique subunit architecture of the D. lab lab lectin indicates the presence of new post translational cleavage sites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Degradation of dimethoate under UV irradiation using TiO2/polymer films prepared by the layer-by-layer (LbL) method was investigated. The thin films were fabricated on glass slides and the surface morphology and roughness of the thin films were characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM) and atomic force microscopy (AFM). The effect of lamp intensity, catalyst loading in the layers, number of bilayers, pH and initial dimethoate concentration on the degradation of dimethoate was systematically studied. The degradation was monitored using high performance liquid chromatography (HPLC) analysis and total organic carbon (TOC) measurements as a function of irradiation time, to see the change in concentration of dimethoate and mineralization, respectively. Complete degradation of dimethoate was achieved under TiO2 optimum loading of 4 g/L at an UV irradiation time of 180 min. Increase in the lamp intensity, catalyst loading and number of bilayers increased the rate of degradation. At a pH of 4.62, complete degradation of dimethoate was observed. The degradation efficiency decreased with increase in initial dimethoate concentration. The degradation byproducts were analyzed and confirmed by gas chromatography-mass spectra (GC-MS). Toxicity of the irradiated samples was measured using the luminescence of bacteria Vibrio fischeri after 30 min of incubation and the results showed more toxicity than the parent compound. Catalyst reusability studies revealed that the fabricated thin films could be repeatedly used for up to ten times without affecting the photocatalytic activity of the films. The findings of the present study are very useful for the treatment of wastewaters contaminated with pesticides. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study examines an improved detoxification and rapid biological degradation of toxic pollutant acrylamide using a bacterium. The acrylamide degrading bacterium was isolated from the soil followed by its screening to know the acrylamide degrading capability. The minimal medium containing acrylamide (30 mM) served as a sole source of carbon and nitrogen for their active growth. The optimization of three different factors was analyzed by using Response Surface Methodology (RSM). The bacteria actively degraded the acrylamide at a temperature of 32 degrees C, with a maximum growth at 30 mM substrate (acrylamide) concentration at a pH of 7.2. The acrylamidase activity and degradation of acrylamide was determined by High Performance Liquid Chromatography (HPLC) and Matrix Assisted Laser Desorption and Ionization Time of Flight mass spectrometer (MALDI-TOF). Based on 168 rRNA analysis the selected strain was identified as Gram negative bacilli Stenotrophomonas acidaminiphila MSU12. The acrylamidase was isolated from bacterial extract and was purified by HPLC, whose mass spectrum showed a molecular mass of 38 kDa. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Glycated hemoglobin (HbA(1c)) is a `gold standard' biomarker for assessing the glycemic index of an individual. HbA(1c) is formed due to nonenzymatic glycosylation at N-terminal valine residue of the P-globin chain. Cation exchange based high performance liquid chromatography (CE HPLC) is mostly used to quantify HbA(1c), in blood sample. A few genetic variants of hemoglobin and post-translationally modified variants of hemoglobin interfere with CE HPLC-based quantification,. resulting in its false positive estimation. Using mass spectrometry, we analyzed a blood sample with abnormally high HbA(1c) (52.1%) in the CE HPLC method. The observed HbA(1c) did not corroborate the blood glucose level of the patient. A mass spectrometry based bottom up proteomics approach, intact globin chain mass analysis, and chemical modification of the proteolytic peptides identified the presence of Hb Beckman, a genetic variant of hemoglobin, in the experimental sample. A similar surface area to charge ratio between HbA(1c) and Hb Beckman might have resulted in the coelution of the variant with HbA(1c) in CE HPLC. Therefore, in the screening of diabetes mellitus through the estimation of HbA(1c), it is important to look for genetic variants of hemoglobin in samples that show abnormally high glycemic index, and HbA(1c) must be estimated using an alternative method. (C) 2015 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN]Rumenic acid (cis9,trans11-18:2) is the main natural isomer of conjugated linoleic acid (CLA). Rumenic acid has many purported health benefits, but effects of most other CLA isomers are unknown. Typically trans7,cis9-18:2 is the second most abundant CLA isomer, but it co-elutes with rumenic acid on conventional polar gas chromatography (GC) columns, requiring complimentary analysis with silver-ion high performance liquid chromatography (Ag(+)-HPLC). Herein we report a rapid method for analyzing rumenic acid and trans7,cis9-18:2 using a 30 m ionic-liquid GC column. Optimal resolution of the two CLA isomers was at 145 degrees C and analysis of backfat from barley-fed cattle compared well with GC/Ag(+)-HPLC (y =0.978x - 0.031, r =0.985, P <0.001).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Levofloxacino é uma fluorquinolona sintética de 3 geração. É eficaz contra uma variedade de infecções, incluindo o trato respiratório superior e inferior, trato urinário, obstétrico, ginecológico, e infecções dermatológicas. Com o objetivo de quantificar o levofloxacino em medicamentos e amostras de pacientes saudáveis e ter a resolução de seu espectro, foram realizados estudos preliminares em medicamento utilizando espectrofluorescência molecular com concentrações na faixa de 28,8 108 ng/mL e cromatografia líquida de alta eficiência (HPLC) na faixa de concentração de 2,9 10,8 g/mL; e também quantificação em urina de paciente em tratamento com o medicamento, usando os dois métodos citados. Após isso, foram feitos estudos conclusivos utilizando espectrofluorescência molecular e os métodos univariado e PLS para determinação de levofloxacino na faixa de concentração de 0 250 ng/mL e PARAFAC combinado com o método da adição de padrão, para quantificação de levofloxacino em urina de paciente saudável, na faixa de concentração de 0 150 ng/mL, com diluição da amostra em três níveis (100 x, 500 x e 1000x). O método de ordem zero se mostrou mais eficiente na determinação de levofloxacino em medicamento que o de primeira ordem, seus desvios padrão foram 2,0% e 7,9%, respectivamente. Já o PARAFAC com o método de adição de padrão apresentou melhores resultados com a urina, pois possibilitou a quantificação do antibiótico em uma amostra complexa, de forma mais precisa e exata com o aumento da diluição da urina, sem necessidade de tratamento prévio.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Isoprene (ISO),the most abundant non-methane VOC, is the major contributor to secondary organic aerosols (SOA) formation. The mechanisms involved in such transformation, however, are not fully understood. Current mechanisms, which are based on the oxidation of ISO in the gas-phase, underestimate SOA yields. The heightened awareness that ISO is only partially processed in the gas-phase has turned attention to heterogeneous processes as alternative pathways toward SOA.

During my research project, I investigated the photochemical oxidation of isoprene in bulk water. Below, I will report on the λ > 305 nm photolysis of H2O2 in dilute ISO solutions. This process yields C10H15OH species as primary products, whose formation both requires and is inhibited by O2. Several isomers of C10H15OH were resolved by reverse-phase high-performance liquid chromatography and detected as MH+ (m/z = 153) and MH+-18 (m/z = 135) signals by electrospray ionization mass spectrometry. This finding is consistent with the addition of ·OH to ISO, followed by HO-ISO· reactions with ISO (in competition with O2) leading to second generation HO(ISO)2· radicals that terminate as C10H15OH via β-H abstraction by O2.

It is not generally realized that chemistry on the surface of water cannot be deduced, extrapolated or translated to those in bulk gas and liquid phases. The water density drops a thousand-fold within a few Angstroms through the gas-liquid interfacial region and therefore hydrophobic VOCs such as ISO will likely remain in these relatively 'dry' interfacial water layers rather than proceed into bulk water. In previous experiments from our laboratory, it was found that gas-phase olefins can be protonated on the surface of pH < 4 water. This phenomenon increases the residence time of gases at the interface, an event that makes them increasingly susceptible to interaction with gaseous atmospheric oxidants such as ozone and hydroxyl radicals.

In order to test this hypothesis, I carried out experiments in which ISO(g) collides with the surface of aqueous microdroplets of various compositions. Herein I report that ISO(g) is oxidized into soluble species via Fenton chemistry on the surface of aqueous Fe(II)Cl2 solutions simultaneously exposed to H2O2(g). Monomer and oligomeric species (ISO)1-8H+ were detected via online electrospray ionization mass spectrometry (ESI-MS) on the surface of pH ~ 2 water, and were then oxidized into a suite of products whose combined yields exceed ~ 5% of (ISO)1-8H+. MS/MS analysis revealed that products mainly consisted of alcohols, ketones, epoxides and acids. Our experiments demonstrated that olefins in ambient air may be oxidized upon impact on the surface of Fe-containing aqueous acidic media, such as those of typical to tropospheric aerosols.

Related experiments involving the reaction of ISO(g) with ·OH radicals from the photolysis of dissolved H2O2 were also carried out to test the surface oxidation of ISO(g) by photolyzing H2O2(aq) at 266 nm at various pH. The products were analyzed via online electrospray ionization mass spectrometry. Similar to our Fenton experiments, we detected (ISO)1-7H+ at pH < 4, and new m/z+ = 271 and m/z- = 76 products at pH > 5.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Desenvolvimento de metodologia para a determinação de aflatoxinas em amostras de amendoim usando espectrofluorimetria e análise dos fatores paralelos (PARAFAC). 2012. 92 f. Dissertação (Mestrado em Engenharia Química) - Instituto de Química, Universidade do Estado do Rio de Janeiro , Rio de Janeiro, 2012. Neste trabalho de pesquisa são descritos dois estudos de caso que se baseiam na determinação de aflatoxinas B1, B2, G1 e G2 em amostras de amendoim, utilizando a técnica de espectroscopia de fluorescência molecular. O primeiro estudo tem o objetivo de avaliar a metodologia empregada para a quantificação de aflatoxinas totais em amendoins, utilizando o método clássico de validação fazendo-se o uso da calibração univariada. Os principais parâmetros de desempenho foram avaliados visando certificar a possibilidade de implementação desta metodologia em laboratórios. O segundo estudo está focado na separação e quantificação destas aflatoxinas com a aplicação combinada da espectrofluorimetria e de um método quimiométrico de segunda ordem (PARAFAC) utilizando a calibração multivariada. Esta técnica pode ser empregada como uma alternativa viável para a determinação de aflatoxinas B1, B2, G1 e G2 isoladamente, tradicionalmente é feito por cromatografia líquida de alta eficiência com detector de fluorescência. Porém, como estes analitos apresentam uma larga faixa de sobreposição espectral e as aflatoxinas (B1 e G1) possuem intensidade de sinal de fluorescência bem abaixo das demais, a separação e quantificação das quatro aflatoxinas foi inviável. O estudo foi retomado com a utilização das aflatoxinas B2 e G2 e os resultados alcançados foram satisfatórios. O método utilizado para a quantificação de aflatoxinas totais apresentou bons resultados, mostrando-se como uma importante ferramenta para a determinação destes analitos. Alem disso, comtempla perfeitamente o que é requerido pela legislação brasileira para a análise de aflatoxinas B1, B2, G1 e G2, que tem como exigência em laudos finais de análise a declaração do somatório, em g/kg, destas aflatoxinas, ou seja, sem a necessidade de quantifica-las separadamente

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O Leito Móvel Simulado (LMS) é um processo de separação de compostos por adsorção muito eficiente, por trabalhar em um regime contínuo e também possuir fluxo contracorrente da fase sólida. Dentre as diversas aplicações, este processo tem se destacado na resolução de petroquímicos e principalmente na atualidade na separação de misturas racêmicas que são separações de um grau elevado de dificuldade. Neste trabalho foram propostas duas novas abordagens na modelagem do LMS, a abordagem Stepwise e a abordagem Front Velocity. Na modelagem Stepwise as colunas cromatográficas do LMS foram modeladas com uma abordagem discreta, onde cada uma delas teve seu domínio dividido em N células de mistura interligadas em série, e as concentrações dos compostos nas fases líquida e sólida foram simuladas usando duas cinéticas de transferência de massa distintas. Essa abordagem pressupõe que as interações decorrentes da transferência de massa entre as moléculas do composto nas suas fases líquida e sólida ocorram somente na superfície, de forma que com essa suposição pode-se admitir que o volume ocupado por cada molécula nas fases sólida e líquida é o mesmo, o que implica que o fator de residência pode ser considerado igual a constante de equilíbrio. Para descrever a transferência de massa que ocorre no processo cromatográfico a abordagem Front Velocity estabelece que a convecção é a fase dominante no transporte de soluto ao longo da coluna cromatográfica. O Front Velocity é um modelo discreto (etapas) em que a vazão determina o avanço da fase líquida ao longo da coluna. As etapas são: avanço da fase líquida e posterior transporte de massa entre as fases líquida e sólida, este último no mesmo intervalo de tempo. Desta forma, o fluxo volumétrico experimental é utilizado para a discretização dos volumes de controle que se deslocam ao longo da coluna porosa com a mesma velocidade da fase líquida. A transferência de massa foi representada por dois mecanismos cinéticos distintos, sem (tipo linear) e com capacidade máxima de adsorção (tipo Langmuir). Ambas as abordagens propostas foram estudadas e avaliadas mediante a comparação com dados experimentais de separação em LMS do anestésico cetamina e, posteriormente, com o fármaco Verapamil. Também foram comparados com as simulações do modelo de equilíbrio dispersivo para o caso da Cetamina, usado por Santos (2004), e para o caso do Verapamil (Perna 2013). Na etapa de caracterização da coluna cromatográfica as novas abordagens foram associadas à ferramenta inversa R2W de forma a determinar os parâmetros globais de transferência de massa apenas usando os tempos experimentais de residência de cada enantiômero na coluna de cromatografia líquida de alta eficiência (CLAE). Na segunda etapa os modelos cinéticos desenvolvidos nas abordagens foram aplicados nas colunas do LMS com os valores determinados na caracterização da coluna cromatográfica, para a simulação do processo de separação contínua. Os resultados das simulações mostram boa concordância entre as duas abordagens propostas e os experimentos de pulso para a caracterização da coluna na separação enantiomérica da cetamina ao longo do tempo. As simulações da separação em LMS, tanto do Verapamil quando da Cetamina apresentam uma discrepância com os dados experimentais nos primeiros ciclos, entretanto após esses ciclos iniciais a correlação entre os dados experimentais e as simulações. Para o caso da separação da cetamina (Santos, 2004), a qual a concentração da alimentação era relativamente baixa, os modelos foram capazes de predizer o processo de separação com as cinéticas Linear e Langmuir. No caso da separação do Verapamil (Perna, 2013), onde a concentração da alimentação é relativamente alta, somente a cinética de Langmuir representou o processo, devido a cinética Linear não representar a saturação das colunas cromatográficas. De acordo como o estudo conduzido ambas as abordagens propostas mostraram-se ferramentas com potencial na predição do comportamento cromatográfico de uma amostra em um experimento de pulso, assim como na simulação da separação de um composto no LMS, apesar das pequenas discrepâncias apresentadas nos primeiros ciclos de trabalho do LMS. Além disso, podem ser facilmente implementadas e aplicadas na análise do processo, pois requer um baixo número de parâmetros e são constituídas de equações diferenciais ordinárias.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Compostos carbonílicos representam uma das principais classes de poluentes atmosféricos e são frequentemente reportados em estudos de poluição atmosférica de interiores. São emitidos para a atmosfera a partir de uma variedade de fontes naturais e antropogênicas. Em projeto empreendido em 2011 pela Secretaria de Estado de Educação do Estado do Rio de Janeiro,foi implementada a climatização em todas as salas de aula de todas as escolas da rede pública estadual. A escala de exposição de ocupantes à climatização, em salas de aula, não apresenta precedentes em nosso estado e representa uma tendência de todo o país. Como é um projeto recente, não há dados a respeito da qualidade do ar interior nesses ambientes e, portanto, das consequências na saúde dos ocupantes. Os procedimentos foram baseados na metodologia TO-11A da U.S.EPA. A técnica de amostragem foi por via seca com reação química, empregando-se cartuchos de sílica revestidos de octadecil (SiO2-C18) impregnados com 2,4-dinitrofenilhidrazina. As carbonilas foram analisados através de Cromatografia Líquida de Alta Eficiência com detecção por UV. Foram encontradas concentrações de formaldeído na faixa de 3,59 a 26,62 μg m-3 (interior) e 0,74 a 23,47 μg m-3 (exterior), acetaldeído na faixa de 0,19 a 259,47 μg m-3 (interior) e 1,19 a 127,51 μg m-3 (exterior), acetona+acroleína na faixa de 0,00 a 48,45 μg m-3 (interior) e 0,00 a 37,00 μg m-3 (exterior). Os valores encontrados geralmente não ultrapassaram os limites determinados por organismos internacionais

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A incorporação do diacetato de clorexidina em resinas macias para reembasamento de próteses pode se tornar uma boa alternativa na terapia com antimicrobianos usados para candidíase oral, uma vez que é independente da cooperação do paciente. Este trabalho teve como objetivo analisar a hipótese que a incorporação de diacetato de clorexidina em resinas macias não alteraria as suas propriedades físico-químicas. Foram analisadas duas resinas macias, uma à base de polimetilmetacrilato (PMMA) e outra à base de polietilmetacrilato (PEMA), com a incorporação de 0,5%, 1,0% e 2,0% de diacetato de clorexidina, além do grupo controle sem diacetato de clorexidina. Os espécimes foram armazenadas em água destilada a 37 durante 2hrs, 48 hrs, 7, 14, 21 e 28 dias e analisados quanto a cristalinidade do polímero através da difração de Raios X, a dureza mensurada com durômetro na escala shore A, o grau de conversão dos monômeros pela Espectroscopia de Infravermelho Transformada de Fourier (FTIR), a lixiviação de monômeros residuais e a liberação da clorexidina por Cromatografia Líquida de Alta Performace (HPLC). Os resultados mostraram que quanto à cristalinidade dos polímeros nas resinas macias à base de PMMA e de PEMA não alteraram após a incorporação de clorexidina, o que está relacionado à dureza Shore A, que aumentou ao longo do tempo, mas sem alteração significativa para nenhuma das concentrações de diacetato de clorexidina testadas. Já quanto ao grau de conversão, após a incorporação de clorexidina, a resina macia à base de PMMA não apresentou diferença estatisticamente significativa (р>0,05), porém a resina macia à base de PEMA apresentou diminuição significativa do grau de conversão (p<0,05), o que refletiu no aumento significativo da lixiviação de monômeros residuais nas concentrações 0,5% e 1,0% de clorexidina (p<0,05), principalmente nas primeiras 48 horas nessa resina. A resina macia à base de PMMA não apresentou alterações do padrão de lixiviação desses monômeros (р>0,05) e para ambas as resinas a cinética de liberação de clorexidina foi relacionada à lixiviação de monômeros residuais, que para a resina macia à base de PEMA foi maior significativamente nas primeiras 48 horas (p<0,05) e para a resina macia à base de PMMA não teve alteração estatisticamente significativa (р>0,05) se mantendo até o último dia de análise. Desse modo, conclui-se que a incorporação do diacetato de clorexidina não afetou a cristalinidade dos polímeros, inalterando a dureza nas duas resinas, porém o grau de conversão sofreu diminuição após a incorporação de diacetato de clorexidina na resina macia à base de PEMA, o que levou ao aumento da lixiviação de monômeros residuais e curta liberação de clorexidina; enquanto que a resina macia à base de PMMA, devido a não alteração significativa do seu grau de conversão, ocorreu menor lixiviação de monômeros residuais e liberação prolongada de clorexidina.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste trabalho foi estabelecer um modelo empregando-se ferramentas de regressão multivariada para a previsão do teor em ésteres metílicos e, simultaneamente, de propriedades físico-químicas de misturas de óleo de soja e biodiesel de soja. O modelo foi proposto a partir da correlação das propriedades de interesse com os espectros de reflectância total atenuada no infravermelho médio das misturas. Para a determinação dos teores de ésteres metílicos foi utilizada a cromatografia líquida de alta eficiência (HPLC), podendo esta ser uma técnica alternativa aos método de referência que utilizam a cromatografia em fase gasosa (EN 14103 e EN 14105). As propriedades físico-químicas selecionadas foram índice de refração, massa específica e viscosidade. Para o estudo, foram preparadas 11 misturas com diferentes proporções de biodiesel de soja e de óleo de soja (0-100 % em massa de biodiesel de soja), em quintuplicata, totalizando 55 amostras. A região do infravermelho estudada foi a faixa de 3801 a 650 cm-1. Os espectros foram submetidos aos pré-tratamentos de correção de sinal multiplicativo (MSC) e, em seguida, à centralização na média (MC). As propriedades de interesse foram submetidas ao autoescalamento. Em seguida foi aplicada análise de componentes principais (PCA) com a finalidade de reduzir a dimensionalidade dos dados e detectar a presença de valores anômalos. Quando estes foram detectados, a amostra era descartada. Os dados originais foram submetidos ao algoritmo de Kennard-Stone dividindo-os em um conjunto de calibração, para a construção do modelo, e um conjunto de validação, para verificar a sua confiabilidade. Os resultados mostraram que o modelo proposto por PLS2 (Mínimos Quadrados Parciais) foi capaz de se ajustar bem os dados de índice de refração e de massa específica, podendo ser observado um comportamento aleatório dos erros, indicando a presença de homocedasticidade nos valores residuais, em outras palavras, o modelo construído apresentou uma capacidade de previsão para as propriedades de massa específica e índice de refração com 95% de confiança. A exatidão do modelo foi também avaliada através da estimativa dos parâmetros de regressão que são a inclinação e o intercepto pela Região Conjunta da Elipse de Confiança (EJCR). Os resultados confirmaram que o modelo MIR-PLS desenvolvido foi capaz de prever, simultaneamente, as propriedades índice de refração e massa específica. Para os teores de éteres metílicos determinados por HPLC, foi também desenvolvido um modelo MIR-PLS para correlacionar estes valores com os espectros de MIR, porém a qualidade do ajuste não foi tão boa. Apesar disso, foi possível mostrar que os dados podem ser modelados e correlacionados com os espectros de infravermelho utilizando calibração multivariada