998 resultados para heart output
Resumo:
Objectives: Existing VADs are single-ventricle pumps needing anticoagulation. We developed a bi-ventricular external assist device that partially reproduces the physiological muscle function of the heart. This artificial muscle could wrap the heart and improve its contractile force.Methods: The device has a carbon fiber skeleton fitting a 30-40kg patient's heart, to which a Nitinol based artificial muscle is connected. The artificial muscle wraps both ventricles. The Nitinol fibers are woven on a Kevlar mesh surrounding each ventricle. The fibers are electrically driven with a dedicated control unit developed for this purpose. We assessed hemodynamic performances of this device using a previously described dedicated bench test. Volume ejected and pressure gradient have been measured with afterload ranging from 10 to 50mmHg.Results: With an afterload of 50mmHg the system has an ejection fraction of 4% on the right side and 5% on the left side. The system is able to generate a systolic ejection of 2.2mL on the right side and 3.25mL on the left side. With an afterload of 25mmHg the results are reduced of about 20%. The activation frequency can reach 80/minute resulting in a total volume displacement of 176mL/minute on the right side and 260mL/minute on the left side.Conclusions: These preliminary studies confirmed the possibility of improving the ejection fraction of a failing heart using artificial muscle for external cardiac compression avoiding anticoagulation therapy. This device could be helpful in weaning cardio-pulmonary bypass and/or for short-term cardio-circulatory support in pediatric population with cardiac failure.
Resumo:
We evaluate conditional predictive densities for U.S. output growth and inflationusing a number of commonly used forecasting models that rely on a large number ofmacroeconomic predictors. More specifically, we evaluate how well conditional predictive densities based on the commonly used normality assumption fit actual realizationsout-of-sample. Our focus on predictive densities acknowledges the possibility that, although some predictors can improve or deteriorate point forecasts, they might have theopposite effect on higher moments. We find that normality is rejected for most modelsin some dimension according to at least one of the tests we use. Interestingly, however,combinations of predictive densities appear to be correctly approximated by a normaldensity: the simple, equal average when predicting output growth and Bayesian modelaverage when predicting inflation.
Resumo:
Although both inflammatory and atherosclerosis markers have been associated with coronary heart disease (CHD) risk, data directly comparing their predictive value are limited. The authors compared the value of 2 atherosclerosis markers (ankle-arm index (AAI) and aortic pulse wave velocity (aPWV)) and 3 inflammatory markers (C-reactive protein (CRP), interleukin-6 (IL-6), and tumor necrosis factor-alpha (TNF-alpha)) in predicting CHD events. Among 2,191 adults aged 70-79 years at baseline (1997-1998) from the Health, Aging, and Body Composition Study cohort, the authors examined adjudicated incident myocardial infarction or CHD death ("hard" events) and "hard" events plus hospitalization for angina or coronary revascularization (total CHD events). During 8 years of follow-up between 1997-1998 and June 2007, 351 participants developed total CHD events (197 "hard" events). IL-6 (highest quartile vs. lowest: hazard ratio = 1.82, 95% confidence interval: 1.33, 2.49; P-trend < 0.001) and AAI (AAI </= 0.9 vs. AAI 1.01-1.30: hazard ratio = 1.57, 95% confidence interval: 1.14, 2.18) predicted CHD events above traditional risk factors and modestly improved global measures of predictive accuracy. CRP, TNF-alpha, and aPWV had weaker associations. IL-6 and AAI accurately reclassified 6.6% and 3.3% of participants, respectively (P's </= 0.05). Results were similar for "hard" CHD, with higher reclassification rates for AAI. IL-6 and AAI are associated with future CHD events beyond traditional risk factors and modestly improve risk prediction in older adults.
Resumo:
So far, cardiac arrest is still associated with high mortality or severe neurological disability in survivors. At the tissue level, cardiac arrest results into an acute condition of generalized hypoxia. A better understanding of the pathophysiology of ischemia-reperfusion and of the inflammatory response that develops after cardiac arrest could help to design novel therapeutic strategies in the future. It seems unlikely that a single drug, acting as a <magic bullet>, might be able to improve survival or neurological prognosis. Lessons learned from pathophysiological mechanisms rather indicate that combined therapies, involving thrombolysis, neuroprotective agents, antioxidants and anti-inflammatory molecules, together with temperature cooling, might represent helpful strategies to improve patient's outcome after cardiac arrest.
Resumo:
GLUT8 is a glucose transporter isoform expressed at high levels in testis; at intermediate levels in the brain, including the hippocampus; and at lower levels in the heart and several other tissues. GLUT8 is located in an intracellular compartment and does not appear to translocate to the cell surface, except in blastocysts, where insulin has been reported to induce its surface expression. Here, we generated mice with inactivation of the glut8 gene. We showed that expression of GLUT8 was not required for normal embryonic development and that glut8-/- mice had normal postnatal development, glucose homeostasis, and response to mild stress. Adult glut8-/- mice showed increased proliferation of hippocampal cells but no defect in memory acquisition and retention. Absence of GLUT8 from the heart did not alter heart size and morphology but led to an increase in P-wave duration, which was not associated with abnormal Nav1.5 Na+ channel or connexin expression. Thus, absence of GLUT8 expression in the mouse caused complex but mild physiological alterations.
Resumo:
Audit report on the Heart of Iowa Regional Transit Agency, Des Moines, for the year ended June 30, 2007
Resumo:
Acute myocardial dysfunction is a typical manifestation of septic shock. Experimentally, the administration of endotoxin [lipopolysacharride (LPS)] to laboratory animals is frequently used to study such dysfunction. However, a majority of studies used load-dependent indexes of cardiac function [including ejection fraction (EF) and maximal systolic pressure increment (dP/dt(max))], which do not directly explore cardiac inotropism. Therefore, we evaluated the direct effects of LPS on myocardial contractility, using left ventricular (LV) pressure-volume catheters in mice. Male BALB/c mice received an intraperitoneal injection of E. coli LPS (1, 5, 10, or 20 mg/kg). After 2, 6, or 20 h, cardiac function was analyzed in anesthetized, mechanically ventilated mice. All doses of LPS induced a significant drop in LV stroke volume and a trend toward reduced cardiac output after 6 h. Concomitantly, there was a significant decrease of LV preload (LV end-diastolic volume), with no apparent change in LV afterload (evaluated by effective arterial elastance and systemic vascular resistance). Load-dependent indexes of LV function were markedly reduced at 6 h, including EF, stroke work, and dP/dt(max). In contrast, there was no reduction of load-independent indexes of LV contractility, including end-systolic elastance (ejection phase measure of contractility) and the ratio dP/dt(max)/end-diastolic volume (isovolumic phase measure of contractility), the latter showing instead a significant increase after 6 h. All changes were transient, returning to baseline values after 20 h. Therefore, the alterations of cardiac function induced by LPS are entirely due to altered loading conditions, but not to reduced contractility, which may instead be slightly increased.
Resumo:
OBJECTIVES: The purpose of this study was to evaluate the association between inflammation and heart failure (HF) risk in older adults. BACKGROUND: Inflammation is associated with HF risk factors and also directly affects myocardial function. METHODS: The association of baseline serum concentrations of interleukin (IL)-6, tumor necrosis factor-alpha, and C-reactive protein (CRP) with incident HF was assessed with Cox models among 2,610 older persons without prevalent HF enrolled in the Health ABC (Health, Aging, and Body Composition) study (age 73.6 +/- 2.9 years; 48.3% men; 59.6% white). RESULTS: During follow-up (median 9.4 years), HF developed in 311 (11.9%) participants. In models controlling for clinical characteristics, ankle-arm index, and incident coronary heart disease, doubling of IL-6, tumor necrosis factor-alpha, and CRP concentrations was associated with 29% (95% confidence interval: 13% to 47%; p < 0.001), 46% (95% confidence interval: 17% to 84%; p = 0.001), and 9% (95% confidence interval: -1% to 24%; p = 0.087) increase in HF risk, respectively. In models including all 3 markers, IL-6, and tumor necrosis factor-alpha, but not CRP, remained significant. These associations were similar across sex and race and persisted in models accounting for death as a competing event. Post-HF ejection fraction was available in 239 (76.8%) cases; inflammatory markers had stronger association with HF with preserved ejection fraction. Repeat IL-6 and CRP determinations at 1-year follow-up did not provide incremental information. Addition of IL-6 to the clinical Health ABC HF model improved model discrimination (C index from 0.717 to 0.734; p = 0.001) and fit (decreased Bayes information criterion by 17.8; p < 0.001). CONCLUSIONS: Inflammatory markers are associated with HF risk among older adults and may improve HF risk stratification.
Resumo:
We examine the dynamics of US output and inflation using a structural time varyingcoefficient VAR. We show that there are changes in the volatility of both variables andin the persistence of inflation. Technology shocks explain changes in output volatility,while a combination of technology, demand and monetary shocks explain variations inthe persistence and volatility of inflation. We detect changes over time in the transmission of technology shocks and in the variance of technology and of monetary policyshocks. Hours and labor productivity always increase in response to technology shocks.
Resumo:
We analyze the effects of neutral and investment-specific technology shockson hours and output. Long cycles in hours are captured in a variety of ways.Hours robustly fall in response to neutral shocks and robustly increase inresponse to investment specific shocks. The percentage of the variance ofhours (output) explained by neutral shocks is small (large); the opposite istrue for investment specific shocks. News shocks are uncorrelated with theestimated technology shocks.
Resumo:
We examine the dynamics of output growth and inflation in the US, Euro area and UK using a structural time varying coefficient VAR. There are important similarities in structural inflation dynamics across countries; output growth dynamics differ. Swings in the magnitude of inflation and output growth volatilities and persistences are accounted for by a combination of three structural shocks. Changes over time in the structure of the economy are limited and permanent variations largely absent. Changes in the volatilities of structural shocks matter.