823 resultados para femoral neck fracture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigations on the fracture behaviour of polymer blends is the topic of this thesis. The blends selected are PP/HDPE and PS/HIPS. PP/HDPE blend is chosen due to its commercial importance and PS/HIPS blend is selected to study the transition from brittle fracture to ductile fracture.PP/HDPE blends were prepared at different compositions by melt blending at 180°C and fracture failure process was investigated by conducting notch sensitivity test and tensile test at different strain rates. The effects of two types of modifiers (particulate and elastomer) on the fracture behaviour and notch sensitivity of PP/HDPE blends were studied. The modifiers used are calcium carbonate, a hard particulate filler commonly used in plastics and Ethylene Propylene Diene Monomer (EPDM). They were added in 2%, 4% and 6% by weight of the blends.The study shows that the mechanical properties of PP/HDPE blends can be optimized by selecting proper blend compositions. The selected modifiers are found to alter and improve the fracture behaviour and notch sensitivity of the blends. Particulate fillers like calcium carbonate can be used for making the mechanical behaviour more stable at the various blend compositions. The resistance to notch sensitivity of the blends is found to be marginally lower in the presence of calcium carbonate. The elastomeric modifier EPDM produces a better stability of the mechanical behaviour. A low concentration of EPDM is sufficient to effect such a change. EPDM significantly improves the resistance to notch sensitivity of the blends. The study shows that judicious selection of modifiers can improve the fracture behaviour and notch sensitivity of PP/HDPE blends and help these materials to be used for critical applications.For investigating the transition in fracture behaviour and failure modes, PS/HIPS blends were selected. The blends were prepared by melt mixing followed by injection moulding to prepare the specimens for conducting tensile, impact and flexure tests. These tests were used to simulate the various conditions which promote failure.The tensile behaviour of unnotched and notched PS/HIPS blend samples were evaluated at slow speeds. Tensile strengths and moduli were found to increase at the higher testing speed for all the blend combinations whereas maximum strain at break was found to decrease. For a particular speed of testing, the tensile strength and modulus show only a very slight decrease as HIPS content is increased up to about 40%. However, there is a drastic decrease on increasing the HIPS content thereafter.The maximum strain at break shows only a very slight change up to about 40% HIPS content and thereafter shows a remarkable increase. The notched specimens also follow a comparable trend even though the notch sensitivity is seen high for PS rich blends containing up to 40% HIPS. The notch sensitivity marginally decreases with increase in HIPS content. At the same time, it is found to increase with the increase in strain rate. It is observed that blends containing more than 40% HIPS fail in ductile mode.The impact characteristics of PSIHIPS blends studied were impact strength, the energy absorbed by the test specimen and impact toughness. Remarkable increase in impact strength is observed as HIPS content in the blend exceeds 40%. The energy absorbed by the test specimens and the impact toughness also show a comparable trend.Flexural testing which helps to characterize the load bearing capacity was conducted on PS/HIPS blend samples at the two different testing speeds of 5mmlmin and 10 mm/min. The flexural strength increases with increase in testing speed for all the blend compositions. At both the speeds, remarkable reduction in flexural strength is observed as HIPS content in the blend exceeds 40%. The flexural strain and flexural energy absorbed by the specimens are found to increase with increase in HIPS content. At both the testing speeds, brittle fracture is observed for PS rich blends whereas HIPS rich blends show ductile mode of failure.Photoelastic investigations were conducted on PS/HIPS blend samples to analyze their failure modes. A plane polariscope with a broad source of light was utilized for the study. The coloured isochromatic fringes formed indicate the presence of residual stress concentration in the blend samples. The coverage made by the fringes on the test specimens varies with the blend composition and it shows a reducing trend with the increase in HIPS content. This indicates that the presence of residual stress is a contributing factor leading to brittle fracture in PS rich blends and this tendency gradually falls with increase in HIPS content and leads to their ductile mode of failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Determinar si la canulación arterial axilar para perfusión selectiva anterograda cerebral (PSAC) con hipotermia moderada reduce la morbilidad, mortalidad y el pronóstico neurológico en pacientes llevados a cirugía del arco aórtico. Pacientes y métodos: Se hace una revisión retrospectiva de 2 cohortes de pacientes a quienes se les realizo cirugía del arco aórtico urgente o electiva, para comparar dos técnicas de canulación arterial diferente; la canulación axilar para perfusión selectiva anterograda cerebral con hipotermia moderada y la canulación femoral con hipotermia profunda, en un periodo de tiempo comprendido entre Diciembre del 2002 y Agosto del 2008 en el servicio de cirugía cardiovascular de la Fundación Cardioinfantil Instituto de Cardiología. Resultados: 68 pacientes, 50 hombres y 18 mujeres fueron llevados a cirugía de arco aórtico 19 pacientes (27%) con diagnóstico de aneurisma de aorta ascendente y arco aórtico y 49 pacientes (72%) con disección aortica tipo A aguda o crónica. A 55 pacientes (80.9%) se les hizo canulación axilar y a 13 pacientes (19,1%) se les hizo canulación femoral. No se encontraron diferencias en las variables preoperatorias entre los dos grupos. La mortalidad global fue de 13,2% (9 pacientes), todas las muertes se presentaron en pacientes con diagnóstico de disección aortica tipo A. El 55% de los pacientes (38/68) se operaron de urgencia. No se presentaron diferencias estadísticamente significativas en la mortalidad entre el grupo de canulación axilar, 8 muertes (14,5%) y el grupo de canulación femoral 1 muerte (7,7%) con (p=0.5). No se encontraron diferencias en la incidencia de déficit neurológico permanente entre los dos grupos, presentándose solamente dos pacientes con accidente cerebrovascular ambos en el grupo de canulación axilar (P=0.48). Conclusiones: la canulación axilar con perfusión cerebral selectiva anterograda en hipotermia moderada representa un método seguro de protección cerebral, con una mortalidad aceptable y una incidencia baja de complicaciones neurológicas permanentes, no encontramos diferencias en la mortalidad o la aparición de eventos neurológicos, cuando se comparo con la técnica de canulación arterial femoral. No se presentaron complicaciones asociadas al sitio de canulación en ninguno de los dos grupos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Comparar las complicaciones del uso de Angioseal® versus compresión manual en los pacientes llevados a cateterismo cardíaco en el Servicio de Hemodinamia de la Fundación Santa Fe de Bogotá, del 1º de enero de 2005 al 31 de diciembre de 2010, mediante punción arterial femoral percutánea. Metodología: Se realizó un Estudio Observacional, Analítico, de tipo Cohorte Retrospectiva. Partiendo de dos grupos de personas con indicación de cateterismo cardíaco por cualquier causa, uno expuesto al procedimiento con Angioseal® y el otro con compresión manual. Resultados: Con el uso de Angioseal® versus compresión manual la aparición de complicaciones fue 7,3% vs 4,1%, estas diferencias no fueron significativas (OR 1,81 IC95 0,96-3,40; RR 1,75 IC95 0,96-3,18) . La enfermedad coronaria (OR 2,27 IC95 1,07-4,79; RR 2,18 IC95 1,06-4,46) y a la colocación de stent (OR 3,49 IC95 1,82-6,69; RR 3,25 IC95 1,75-6,02 si se relacionaron significativamente con la aparición de complicaciones menores. Conclusión: No encontramos soporte para aprobar o desaprobar el uso de Angioseal® o compresión manual como manejo de la hemostasia, con respecto a las complicaciones. Sin embargo, se encontró que la colocación de stents está fuertemente relacionada con el desarrollo de complicaciones menores, lo cual hace que estos pacientes deban ser objeto de monitorización estrecha.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se realizó un estudio descriptivo observacional para describir los hallazgos radiológicos pre y postoperatorios de pacientes llevados a osteotomía periacetabular tipo Ganz, según las medidas radiológicas del mismo autor, en el Instituto de Ortopedia infantil Roosevelt entre los años 2008 y 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El trauma de codo y la fractura de cúpula radial resultan ser un motivo de consulta frecuente en nuestro medio. Es común en nuestro medio que a pesar de tener radiografías de codo en las que se evidencia fractura de cúpula radial se solicite un TAC de codo. Consideramos que el TAC es una herramienta útil en algunos casos de fracturas de la cúpula radial, es decir, no se debe tomar de forma rutinaria el TAC de codo en los pacientes con fracturas de cúpula radial como es usual en nuestro medio. Existen pocos estudios que comparan la concordancia inter observador de las clasificaciones utilizadas para las fracturas de cúpula radial, pero, no existe en la literatura mundial un estudio que evalué las diferencias entre la clasificación de la fractura en base a radiografías y tomografía entre un grupo ortopedistas traumatólogos y sub-especialistas de miembro superior. La realización de este estudio permite elaborar guías de manejo de pacientes con fractura de cúpula radial en la que se racionalizara el uso del TAC de codo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The tight junction (TJ) is one of the most important structures established during merozoite invasion of host cells and a large amount of proteins stored in Toxoplasma and Plasmodium parasites’ apical organelles are involved in forming the TJ. Plasmodium falciparum and Toxoplasma gondii apical membrane antigen 1 (AMA-1) and rhoptry neck proteins (RONs) are the two main TJ components. It has been shown that RON4 plays an essential role during merozoite and sporozoite invasion to target cells. This study has focused on characterizing a novel Plasmodium vivax rhoptry protein, RON4, which is homologous to PfRON4 and PkRON4. Methods: The ron4 gene was re-annotated in the P. vivax genome using various bioinformatics tools and taking PfRON4 and PkRON4 amino acid sequences as templates. Gene synteny, as well as identity and similarity values between open reading frames (ORFs) belonging to the three species were assessed. The gene transcription of pvron4, and the expression and localization of the encoded protein were also determined in the VCG-1 strain by molecular and immunological studies. Nucleotide and amino acid sequences obtained for pvron4 in VCG-1 were compared to those from strains coming from different geographical areas. Results: PvRON4 is a 733 amino acid long protein, which is encoded by three exons, having similar transcription and translation patterns to those reported for its homologue, PfRON4. Sequencing PvRON4 from the VCG-1 strain and comparing it to P. vivax strains from different geographical locations has shown two conserved regions separated by a low complexity variable region, possibly acting as a “smokescreen”. PvRON4 contains a predicted signal sequence, a coiled-coil α-helical motif, two tandem repeats and six conserved cysteines towards the carboxyterminus and is a soluble protein lacking predicted transmembranal domains or a GPI anchor. Indirect immunofluorescence assays have shown that PvRON4 is expressed at the apical end of schizonts and co-localizes at the rhoptry neck with PvRON2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Rhoptries are specialized organelles from parasites belonging to the phylum Apicomplexa; they secrete their protein content during invasion of host target cells and are sorted into discrete subcompartments within rhoptry neck or bulb. This distribution is associated with these proteins’ role in tight junction (TJ) and parasitophorous vacuole (PV) formation, respectively. Methods: Plasmodium falciparum RON2 amino acid sequence was used as bait for screening the codifying gene for the homologous protein in the Plasmodium vivax genome. Gene synteny, as well as identity and similarity values, were determined for ron2 and its flanking genes among P. falciparum, P. vivax and other malarial parasite genomes available at PlasmoDB and Sanger Institute databases. Pvron2 gene transcription was determined by RT-PCR of cDNA obtained from the P. vivax VCG-1 strain. Protein expression and localization were assessed by Western blot and immunofluorescence using polyclonal anti-PvRON2 antibodies. Co-localization was confirmed using antibodies directed towards specific microneme and rhoptry neck proteins. Results and discussion: The first P. vivax rhoptry neck protein (named here PvRON2) has been identified in this study. PvRON2 is a 2,204 residue-long protein encoded by a single 6,615 bp exon containing a hydrophobic signal sequence towards the amino-terminus, a transmembrane domain towards the carboxy-terminus and two coiled coil a-helical motifs; these are characteristic features of several previously described vaccine candidates against malaria. This protein also contains two tandem repeats within the interspecies variable sequence possibly involved in evading a host’s immune system. PvRON2 is expressed in late schizonts and localized in rhoptry necks similar to what has been reported for PfRON2, which suggests its participation during target cell invasion. Conclusions: The identification and partial characterization of the first P. vivax rhoptry neck protein are described in the present study. This protein is homologous to PfRON2 which has previously been shown to be associated with PfAMA-1, suggesting a similar role for PvRON2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Plasmodium vivax malaria remains a major health problem in tropical and sub-tropical regions worldwide. Several rhoptry proteins which are important for interaction with and/or invasion of red blood cells, such as PfRONs, Pf92, Pf38, Pf12 and Pf34, have been described during the last few years and are being considered as potential anti-malarial vaccine candidates. This study describes the identification and characterization of the P. vivax rhoptry neck protein 1 (PvRON1) and examine its antigenicity in natural P. vivax infections. Methods: The PvRON1 encoding gene, which is homologous to that encoding the P. falciparum apical sushi protein (ASP) according to the plasmoDB database, was selected as our study target. The pvron1 gene transcription was evaluated by RT-PCR using RNA obtained from the P. vivax VCG-1 strain. Two peptides derived from the deduced P. vivax Sal-I PvRON1 sequence were synthesized and inoculated in rabbits for obtaining anti-PvRON1 antibodies which were used to confirm the protein expression in VCG-1 strain schizonts along with its association with detergent-resistant microdomains (DRMs) by Western blot, and its localization by immunofluorescence assays. The antigenicity of the PvRON1 protein was assessed using human sera from individuals previously exposed to P. vivax malaria by ELISA. Results: In the P. vivax VCG-1 strain, RON1 is a 764 amino acid-long protein. In silico analysis has revealed that PvRON1 shares essential characteristics with different antigens involved in invasion, such as the presence of a secretory signal, a GPI-anchor sequence and a putative sushi domain. The PvRON1 protein is expressed in parasite's schizont stage, localized in rhoptry necks and it is associated with DRMs. Recombinant protein recognition by human sera indicates that this antigen can trigger an immune response during a natural infection with P. vivax. Conclusions: This study shows the identification and characterization of the P. vivax rhoptry neck protein 1 in the VCG-1 strain. Taking into account that PvRON1 shares several important characteristics with other Plasmodium antigens that play a functional role during RBC invasion and, as shown here, it is antigenic, it could be considered as a good vaccine candidate. Further studies aimed at assessing its immunogenicity and protection-inducing ability in the Aotus monkey model are thus recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Las fracturas de la cúpula radial corresponden a un tercio de todas las fracturas del codo en adultos (1), por lo que se toman radiografías o tomografías, sin embargo no existe literatura que soporte la realización de la tomografía como estudio complementario, por lo que preguntamos ¿La tomografía de codo cambia la conducta tomada previamente con radiografía en fracturas de cúpula radial? Se propone un estudio de concordancia, donde se evalúan las radiografías y tomografías por parte de dos cirujanos de codo, de pacientes con diagnóstico de fractura de cúpula radial valorados en urgencias de dos hospitales de tercer nivel de Bogotá desde enero 2011 a enero 2013. Se revisaron 116 historias, 99 cumplieron los criterios, las radiografías fueron revisadas por dos ortopedistas de codo quienes realizaron clasificación de Mason obteniendo un κ 1 (p˂ 0,00), propuesta de tratamiento postradiografía κ 0,934 (p˂ 0,000 IC95% 0.85, 1). Tratamiento post-tomografía de codo κ 0.949 (p˂ 0,00 IC95% 0.867,1). Concordancia intra-ortopedista de la conducta pre y post-tomografía hay cambio en la conducta del ortopedista 1 en 32.6% (κ 0.674 p˂ 0,00 IC95% 0.52, 0.818) y del ortopedista 2 en 36% (κ 0.64 p˂ 0,00 IC95% 0.452, 0.792). Se dividieron los pacientes en Mason I, II, III con concordancia considerable en los pacientes Mason I y III, mientras que en Mason II fue una concordancia aceptable lo que significa que el uso de tomografía de codo cambia la conducta en general pero sobretodo en pacientes clasificados Masson II.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La present tesi proposa una metodología per a la simulació probabilística de la fallada de la matriu en materials compòsits reforçats amb fibres de carboni, basant-se en l'anàlisi de la distribució aleatòria de les fibres. En els primers capítols es revisa l'estat de l'art sobre modelització matemàtica de materials aleatoris, càlcul de propietats efectives i criteris de fallada transversal en materials compòsits. El primer pas en la metodologia proposada és la definició de la determinació del tamany mínim d'un Element de Volum Representatiu Estadístic (SRVE) . Aquesta determinació es du a terme analitzant el volum de fibra, les propietats elàstiques efectives, la condició de Hill, els estadístics de les components de tensió i defromació, la funció de densitat de probabilitat i les funcions estadístiques de distància entre fibres de models d'elements de la microestructura, de diferent tamany. Un cop s'ha determinat aquest tamany mínim, es comparen un model periòdic i un model aleatori, per constatar la magnitud de les diferències que s'hi observen. Es defineix, també, una metodologia per a l'anàlisi estadístic de la distribució de la fibra en el compòsit, a partir d'imatges digitals de la secció transversal. Aquest anàlisi s'aplica a quatre materials diferents. Finalment, es proposa un mètode computacional de dues escales per a simular la fallada transversal de làmines unidireccionals, que permet obtenir funcions de densitat de probabilitat per a les variables mecàniques. Es descriuen algunes aplicacions i possibilitats d'aquest mètode i es comparen els resultats obtinguts de la simulació amb valors experimentals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context: Evidence is limited on the effects of different patterns of use of postmenopausal hormone therapy on fracture incidence and particularly on the effects of ceasing use. Objective: To investigate the effect of different patterns of hormone therapy use on fracture incidence. Design, Setting, and Participants: Prospective study of 138737 postmenopausal women aged 50 to 69 years recruited from the UK general population in 19961998 (the Million Women Study) and followed up for 1.9 to 3.9 years (average, 2.8 years) for fracture incidence. Main Outcome Measure: Adjusted relative risk (RR) for incident fracture (except fracture of the fingers, toes, and ribs) in hormone therapy users compared with never users at baseline. Results: A total of 5197 women (3.7%) reported 1 or more fractures, 79% resulting from falls. Current users of hormone therapy at baseline had a significantly reduced incidence of fracture (RR, 0.62; 95% confidence interval [CI], 0.58-0.66; P<.001). This protection was evident soon after hormone therapy began, and the RR decreased with increasing duration of use (P=.001). Among current users at baseline the RR of fracture did not vary significantly according to whether estrogen-only, estrogen-progestin, or other types of hormones were used (RR [95% CI], 0.64 [0.58-0.71], 0.58 [0.53-0.64], and 0.67 [0.56-0.80], respectively; P=19), nor did it vary significantly according to estrogen dose or estrogen or progestin constituents. The RR associated with current use of hormone therapy did not vary significantly according to 11 personal characteristics of study participants, including their age at menopause, body mass index, and physical activity. Past users of hormone therapy at baseline experienced no significant protection against fractures (RR, 1.07; 95% CI, 0.99-1.15); incidence rates returned to those of never-users within about a year of ceasing use. Conclusions: All types of hormone therapy studied confer substantial protection against fracture while they are used. This protection appears rapidly after use commences and wears off rapidly after use ceases. The older women are, the greater is their absolute reduction in fracture incidence while using hormone therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assumption that negligible work is involved in the formation of new surfaces in the machining of ductile metals, is re-examined in the light of both current Finite Element Method (FEM) simulations of cutting and modern ductile fracture mechanics. The work associated with separation criteria in FEM models is shown to be in the kJ/m2 range rather than the few J/m2 of the surface energy (surface tension) employed by Shaw in his pioneering study of 1954 following which consideration of surface work has been omitted from analyses of metal cutting. The much greater values of surface specific work are not surprising in terms of ductile fracture mechanics where kJ/m2 values of fracture toughness are typical of the ductile metals involved in machining studies. This paper shows that when even the simple Ernst–Merchant analysis is generalised to include significant surface work, many of the experimental observations for which traditional ‘plasticity and friction only’ analyses seem to have no quantitative explanation, are now given meaning. In particular, the primary shear plane angle φ becomes material-dependent. The experimental increase of φ up to a saturated level, as the uncut chip thickness is increased, is predicted. The positive intercepts found in plots of cutting force vs. depth of cut, and in plots of force resolved along the primary shear plane vs. area of shear plane, are shown to be measures of the specific surface work. It is demonstrated that neglect of these intercepts in cutting analyses is the reason why anomalously high values of shear yield stress are derived at those very small uncut chip thicknesses at which the so-called size effect becomes evident. The material toughness/strength ratio, combined with the depth of cut to form a non-dimensional parameter, is shown to control ductile cutting mechanics. The toughness/strength ratio of a given material will change with rate, temperature, and thermomechanical treatment and the influence of such changes, together with changes in depth of cut, on the character of machining is discussed. Strength or hardness alone is insufficient to describe machining. The failure of the Ernst–Merchant theory seems less to do with problems of uniqueness and the validity of minimum work, and more to do with the problem not being properly posed. The new analysis compares favourably and consistently with the wide body of experimental results available in the literature. Why considerable progress in the understanding of metal cutting has been achieved without reference to significant surface work is also discussed.