925 resultados para discrete tomography
Resumo:
This study analyzed degrees of demineralization in bovine enamel using synchrotron microcomputed tomography (SMCT) and hardness measurements (Knoop hardness number, KHN). For 5 days, 40 bovine enamel blocks were individually subjected to a pH cycling model and treatment with fluoride dentifrices (placebo, 275, 550 and 1,100 mu g F/g) diluted in deionized water twice a day. Surface hardness number and cross-sectional profiles of hardness and mineral concentration (by SMCT) were determined. Integrated hardness (KHN x mu m) for sound and demineralized specimens was calculated and subtracted to give the integrated loss of hardness (Delta KHN) for the lesions. Increasing fluoride concentration in the dentifrices led to higher values for surface hardness after pH cycling and mineral concentration (g(HAp) cm(-3)), and lower values for Delta KHN (p < 0.05). From the present results, it may be concluded that hardness measurements revealed demineralization in all groups, which was lower in groups treated with dentifrice with a higher F concentration. SMCT and hardness measurements gave similar results in areas with higher demineralization, but diverged in areas with lower demineralization. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. The aim of this study was to detect the development of experimentally induced periapical lesions using conventional radiography and computed tomography.Study design. The root canals of dogs' teeth were exposed to the oral environment for 7 days for contamination and then sealed for 7 days (GI), 15 days (GII), 30 days (GIII), and 60 days (GIV). Immediately after each experimental period, radiographs and tomograms were taken in order to detect the occurrence of periapical bone resorption. The periapical radiographs were digitized and areas of bone resorption were measured using the VIXWIN 2000 software. Scores were assigned to the tomograms based on the progression of periapical bone resorption. The specimens were evaluated by calibrated examiners who were blinded to the groups. The radiographic results were analyzed by ANOVA and Tukey's test (P <.05) and the tomographic results were analyzed by Kruskal-Wallis and Dunn's tests (P <.05).Results. The radiographic evaluation did not reveal periapical lesions at the 7-day control. Lesions were radiographically visible at 15 and 30 days (47.4% and 77.8% of the cases, respectively) and presented similar dimensions (P <.05). At 60 days, lesions were detected in all specimens, presenting larger dimensions than those of the earlier evaluation periods (P <.05). The tomographic evaluation detected lesions at 7 and 15 days (32.5% and 83.3% of the cases, respectively). Lesions were detected in all specimens at the 30- and 60-day periods, when the greatest values of bone resorption were observed (P <.05).Conclusions. Tomography was able to detect periapical lesion development in its initial stages, even when the lesions were undetectable radiographically.
Resumo:
Introduction: The aim of this study was to compare the increase of the root canal area after instrumentation with EndoSequence or ProTaper rotary systems. Methods: Twenty-two mesial root canals from mandibular molars were instrumented. Teeth were mounted on a base, numbered, and divided into 2 groups; teeth from 1-11 (PT group) were instrumented by using the ProTaper system, and teeth from 12-22 (ES group) were instrumented by using the EndoSequence system. Cone beam computed tomography was performed on all teeth before and after instrumentation. Measurements at 3,5, and 7 mm as well as differences in instrument performance were statistically compared by the Student t test at 5% significance level. Results: Both systems increased significantly the root canal area (P < .05) at all levels. Comparison between the rotary systems showed significantly greater increase (P < .05) for EndoSequence at 3 mm, with no statistically significant difference (P < .05) at the other levels. Conclusions: Both rotary systems increased significantly the root canal area. (J Endod 2010;36:1179-1182)
Resumo:
Computerized tomography (CT) is a valuable tool for diagnosis and planning in conventional and surgical endodontic therapy. This case report describes the use of CT in the diagnosis of a periapical lesion undetected by periapical radiography in the mandibular molar area. The CT also showed a possible mesial root perforation associated with the lesion. Following CT, surgical planning, periradicular curettage, and sealing of the root perforation were performed. Eight years after surgery, cone beam CT revealed periapical bone repair. Computerized tomography can be an important resource for diagnosis and planning in conventional and surgical endodontic therapy, as well as for evaluation of post-treatment bone repair. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 629-633)
Resumo:
Ties among event times are often recorded in survival studies. For example, in a two week laboratory study where event times are measured in days, ties are very likely to occur. The proportional hazards model might be used in this setting using an approximated partial likelihood function. This approximation works well when the number of ties is small. on the other hand, discrete regression models are suggested when the data are heavily tied. However, in many situations it is not clear which approach should be used in practice. In this work, empirical guidelines based on Monte Carlo simulations are provided. These recommendations are based on a measure of the amount of tied data present and the mean square error. An example illustrates the proposed criterion.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Introduction: The aim of this study was to evaluate craniofacial asymmetry by using 2-dimensional (2D) poster-oanterior cephalometric images, 3-dimensional cone-beam computed tomography (CBCT), and physical measurements (gold standard). Methods: Ten dry human skulls were assessed, and radiopaque markers were placed on 17 skeletal landmarks. Twenty linear measurements were taken on each side to compare the right and left sides and to compare these measurements with the physical measurements made with a digital caliper. To acquire the 2D posteroanterior radiographs, an Extraoral Phosphor Storage Plate (Air Techniques, Chicago, Ill) was used as the image receptor with a Eureka x-ray-Duocon Machlett unit (Machlett Laboratores, Chicago, Ill). Three-dimensional imaging data were acquired from a CB MercuRay (Hitachi Medical, Tokyo, Japan). Results: on average, the right side was larger than the left for most of the 20 distances evaluated in the digital 2D and the CBCT images, and there was poor agreement between the digital 2D images and the physical measurements (kappa = 0.0609) and almost perfect agreement (kappa = 0.92) between the CBCT and physical measurements when individual measurements were considered. Conclusions: Human skulls, with no apparent asymmetry, had some differences between the right and left sides, with dominance for the right side but with no clinical significance. CBCT can better evaluate craniofacial morphology when compared with digital 2D images. (Am J Orthod Dentofacial Orthop 2011; 139: e523-e531)
Resumo:
We show that by introducing appropriate local Z(N)(Ngreater than or equal to13) symmetries in electroweak models it is possible to implement an automatic Peccei-Quinn symmetry, at the same time keeping the axion protected against gravitational effects. Although we consider here only an extension of the standard model and a particular 3-3-1 model, the strategy can be used in any kind of electroweak model. An interesting feature of this 3-3-1 model is that if we add (i) right-handed neutrinos, (ii) the conservation of the total lepton number, and (iii) a Z(2) symmetry, the Z(13) and the chiral Peccei-Quinn U(1)P-Q symmetries are both accidental symmetries in the sense that they are not imposed on the Lagrangian but are just a consequence of the particle content of the model, its gauge invariance, renormalizability, and Lorentz invariance. In addition, this model has no domain wall problem.
Resumo:
Suppose we have identified three clusters of galaxies as being topological copies of the same object. How does this information constrain the possible models for the shape of our universe? It is shown here that, if our universe has flat spatial sections, these multiple images can be accommodated within any of the six classes of compact orientable three-dimensional flat space forms. Moreover, the discovery of two more triples of multiple images in the neighbourhood of the first one would allow the determination of the topology of the universe, and in most cases the determination of its size.
Resumo:
We show that Peccei-Quinn and lepton number symmetries can be a natural outcome in a 3-3-1 model with right-handed neutrinos after imposing a Z(11)circle timesZ(2) symmetry. This symmetry is suitably accommodated in this model when we augment its spectrum by including merely one singlet scalar field. We work out the breaking of the Peccei-Quinn symmetry, yielding the axion, and study the phenomenological consequences. The main result of this work is that the solution to the strong CP problem can be implemented in a natural way, implying an invisible axion phenomenologically unconstrained, free of domain wall formation, and constituting a good candidate for the cold dark matter.
Resumo:
The main aspects of a discrete phase space formalism are presented and the discrete dynamical bracket, suitable for the description of time evolution in finite-dimensional spaces, is discussed. A set of operator bases is defined in such a way that the Weyl-Wigner formalism is shown to be obtained as a limiting case. In the same form, the Moyal bracket is shown to be the limiting case of the discrete dynamical bracket. The dynamics in quantum discrete phase spaces is shown not to be attained from discretization of the continuous case.
Time evolution of the Wigner function in discrete quantum phase space for a soluble quasi-spin model
Resumo:
The discrete phase space approach to quantum mechanics of degrees of freedom without classical counterparts is applied to the many-fermions/quasi-spin Lipkin model. The Wi:ner function is written for some chosen states associated to discrete angle and angular momentum variables, and the rime evolution is numerically calculated using the discrete von Neumnnn-Liouville equation. Direct evidences in the lime evolution of the Wigner function are extracted that identify a tunnelling effect. A connection with a SU(2)-based semiclassical continuous approach to the Lipkin model is also presented.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)