976 resultados para diferencial-pulse voltammetry
Resumo:
The momentum distributions of electrons ionized from H atoms by chirped few-cycle attosecond pulses are investigated by numerically solving the time-dependent Schrödinger equation. The central carrier frequency of the pulse is chosen to be 25 eV, which is well above the ionization threshold. The asymmetry (or difference) in the yield of electrons ionized along and opposite to the direction of linear laser polarization is found to be very sensitive to the pulse chirp (for pulses with fixed carrier-envelope phase), both for a fixed electron energy and for the energy-integrated yield. In particular, the larger the pulse chirp, the larger the number of times the asymmetry changes sign as a function of ionized electron energy. For a fixed chirp, the ionized electron asymmetry is found to be sensitive also to the carrier-envelope phase of the few-cycle pulse.
Resumo:
Nowadays, we live in a time of rapid research for technological advances, in a way that this pursuit of new technologies is deeply connected to the diversity of new materials that have been developed by mankind. It deals with issues such as materials with enhanced properties which offer better quality, less cost and high performance, while they are accessible both in their production and moment of operation. In this context, it was required to develop electrodes that were easy to prepare as well as which present high electric conductivity and good mechanic proprieties by using carbonaceous material as basis. For this reason, the best parameters of the furfuryl resin cures were established with different pH variations through viscosimetric measurements and differential scanning calorimetry. By scanning electron microscopy (SEM) was possible to identify an increased porosity in the samples with pH 7 and pH 8, as compared to samples with lower pH content. After carbonization of the material, the characterization of monolithic glassy carbon was held by means of FT-IR techniques, Raman spectroscopy, X-ray diffraction and cyclic voltammetry. The spectra showed that the change in pH does not have significant influence on the crystallographic ordering of the material and its structural characteristics. As for the electrochemical character, the CVM electrodes showed excellent response, with good reversibility and wide potential window. Some voltammetric curve deviations were only observed for the sample with pH 4, which may be related to processing parameters adopted
Resumo:
The degradation behaviour of SnO(2)-based varistors (SCNCr) due to current pulses (8/20 mu s) is reported here for the first time in comparison with the ZnO-based commercial varistors (ZnO). Puncturing and/or cracking failures were observed in ZnO-based varistors possessing inferior thermo-mechanical properties in comparison with that found in a SCNCr system free of failures. Both systems presented electric degradation related to the increase in the leakage current and decrease in the electric breakdown field, non-linear coefficient and average value of the potential barrier height. However, it was found that a more severe degradation occurred in the ZnO-based varistors concerning their non-ohmic behaviour, while in the SCNCr system, a strong non-ohmic behaviour remained after the degradation. These results indicate that the degradation in the metal oxide varistors is controlled by a defect diffusion process whose rate depends on the mobility, the concentration of meta-stable defects and the amount of electrically active interfaces. The improved behaviour of the SCNCr system is then inferred to be associated with the higher amount of electrically active interfaces (85%) and to a higher energy necessary to activate the diffusion of the specific defects.
Resumo:
Pulse repetition rates and the number of laser pulses are among the most important parameters that do affect the analysis of solid materials by laser induced breakdown spectroscopy, and the knowledge of their effects is of fundamental importance for suggesting analytical strategies when dealing with laser ablation processes of polymers. In this contribution, the influence of these parameters in the ablated mass and in the features of craters was evaluated in polypropylene and high density polyethylene plates containing pigment-based PbCrO4. Surface characterization and craters profile were carried out by perfilometry and scanning electron microscopy. Area, volume and profile of craters were obtained using Taylor Map software. A laser induced breakdown spectroscopy system consisted of a Q-Switched Nd:YAG laser (1064 nm, 5 ns) and an Echelle spectrometer equipped with ICCD detector were used. The evaluated operating conditions consisted of 10, 25 and 50 laser pulses at 1, 5 and 10 Hz, 250 mJ/pulse (85 J cm(-2)), 2 mu s delay time and 6 mu s integration time gate. Differences in the topographical features among craters of both polymers were observed. The decrease in the repetition rate resulted in irregular craters and formation of edges, especially in polypropylene sample. The differences in the topographical features and ablated masses were attributed to the influence of the degree of crystallinity, crystalline melting temperature and glass transition temperature in the ablation process of the high density polyethylene and polypropylene. It was also observed that the intensities of chromium and lead emission signals obtained at 10 Hz were two times higher than at 5 Hz by keeping the number of laser pulses constant. (C) 2011 Elsevier B. V. All rights reserved.
Resumo:
Background. Acute normovolemic hemodilution (ANH) is an alternative to blood transfusion in surgeries involving blood loss. This experimental study was designed to evaluate whether pulse pressure variation (PPV) would be an adequate tool for monitoring changes in preload during ANH, as assessed by transesophageal echocardiography. Methods. Twenty-one anesthetized and mechanically ventilated pigs were randomized into three groups: CTL (control), HES (hemodilution with 6% hydroxyethyl starch at a 1:1 ratio) or NS (hemodilution with saline 0.9% at a 3:1 ratio). Hemodilution was performed in animals of groups NS and HES in two stages, with target hematocrits 22% and 15%, achieved at 30-minute intervals. After two hours, 50% of the blood volume withdrawn was transfused and animals were monitored for another hour. Statistical analysis was based on ANOVA for repeated measures followed by multiple comparison test (P<0.05). Pearson's correlations were performed between changes in left ventricular end-diastolic volume (LVEDV) and PPV, central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP). Results. Group NS received a significantly greater amount of fluids during ANH (NS, 900 +/- 168 mL vs. HES, 200 +/- 50 mL, P<0.05) and presented greater urine output (NS, 2643 +/- 1097mL vs. HES, 641 +/- 338mL, P<0.001). Significant decreases in LVEDV were observed in group NS from completion of ANH until transfusion. In group HES, only increases in LVEDV were observed, at the end of ANH and at transfusion. Such changes in LVEDV (Delta LVEDV) were better reflected by changes in PPV (Delta PPV, R=-0.62) than changes in CVP (Delta CVP R=0.32) or in PAOP (Delta PAOP, R=0.42, respectively). Conclusion. Changes in preload during ANH were detected by changes in PPV. Delta PPV was superior to Delta PAOP and Delta CVP to this end. (Minerva Anestesiol 2012;78:426-33)
Resumo:
This paper describes the applicability of a Hg-electroplated-Pt ultramicroelectrode in the quantification of elemental sulphur in naphtha samples by square-wave voltammetry. A reproducible deposition methodology was studied and is reported in this paper. This methodology is innovative and relies on the quality of the mercury stock solution to obtain reproducible surfaces required for the analytical methodology. All analyses were performed using a Hg-electroplated-Pt ultramicroelectrode (Hg-Pt UME) due to the low sensibility of such devices to ohmic drops in resistive solutions. The responses of the peak areas in voltammetric experiments were linear in all of the range studied. The method developed here is accurate and reproducible, with a detection limit of 0.010 mg L-1 and a good recovery range for both standard solutions of elemental sulphur (85 to 99%) and real naphtha sample (79%). These results attest to the potential for the application of this electroanalytical methodology in determining elemental sulphur in naphtha samples containing mercaptans and disulphides.
Resumo:
Caffeine determination using a fast-scan voltammetric procedure at a carbon fiber ultramicroelectrode (CF-UME) is described. The CF-UME was submitted to electrochemical pretreatment. Parameters such as number of acquisition cycles, scan rate, potential window, and the electrochemical surface pretreatment were optimized. Using the optimized conditions, it was possible to achieve a LDR from 10.0 up to 200 mu mol L-1, with a LOD of 3.33 mu mol L-1. The method has been applied in the determination of caffeine in commercial samples, with errors of 1.0-3.5% in relation to the label values and recoveries of 97-114% within the linear range.
Resumo:
Air conditioning and lighting costs can be reduced substantially by changing the optical properties of "intelligent windows." The electrochromic devices studied to date have used copper as an additive. Copper, used here as an electrochromic material, was dissolved in an aqueous animal protein-derived gel electrolyte. This combination constitutes the electrochromic system for reversible electrodeposition. Cyclic voltammetry, chronoamperometric and chromogenic analyses indicated that were obtained good conditions of transparency (initial transmittance of 70%), optical reversibility, small potential window (2.1 V), variation of transmittance in visible light (63.6%) and near infrared (20%) spectral regions. Permanence in the darkened state was achieved by maintaining a lower pulse potential (-0.16 V) than the deposition potential (-1.0 V). Increasing the number of deposition and dissolution cycles favored the transmittance and photoelectrochemical reversibility of the device. The conductivity of the electrolyte (10(-3) S/cm) at several concentrations of CuCl2 was determined by electrochemical impedance spectroscopy. A thermogravimetric analysis confirmed the good thermal stability of the electrolyte, since the mass loss detected up to 100 degrees C corresponded to water evaporation and decomposition of the gel started only at 200 degrees C. Micrographic and small angle X-ray scattering analyses indicated the formation of a persistent deposit of copper particles on the ITO. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Hourly blood samples were collected from 10 mares during 24 h of each of the preluteolytic, luteolytic, and postluteolytic periods. The autocorrelation function of the R program was used to detect pulse rhythmicity, and the intra-assay CV was used to locate and characterize pulses of prolactin (PRL) and a metabolite of prostaglandin F2 alpha (PGFM). Rhythmicity of PRL and PGFM concentrations was detected in 67% and 89% of mares, respectively. Combined for the three periods (no difference among periods), the PRL pulses were 5.2 +/- 0.4 h (mean +/- SEM) at the base, 7.5 +/- 1.5 h between nadirs of adjacent pulses, and 12.3 +/- 1.5 h from peak to peak. The peaks of PRL pulses were greater (P < 0.05) during the luteolytic period (46 +/- 14 ng/mL) and postluteolytic period (52 15 ng/mL) than during the preluteolytic period (17 3 ng/mL). Concentrations of PRL during hours of a PGFM pulse were different (P < 0.003) within the luteolytic period and postluteolytic period and were greatest at the PGFM peak; PRL concentrations during a PGFM pulse were not different during the preluteolytic period. The frequency of the peak of PRL and PGFM pulses occurring at the same hour (synchrony) was greater for the luteolytic period (65%, P < 0.01) and postluteolytic period (50%, P < 0.001) than for the preluteolytic period (17%). This is the first report in mares on characterization and rhythmicity of PRL pulses, synchrony between PRL and PGFM pulses, and greater PRL activity during the luteolytic and postluteolytic periods than during the preluteolytic period. (C) 2012 Elsevier Inc. All rights reserved.
Resumo:
Parabens are antimicrobial preservatives widely used in pharmaceutical, cosmetic and food industries. The alkyl chain connected to the ester group defines some important physicochemical characteristics of these compounds, including the partition coefficient and redox properties. The voltammetric and computational analyses were carried out in order to evaluate the redox behavior of these compounds and other phenolic analogues. A strong correlation between chemical substituents inductive effects of parabens with redox potentials was observed. Using cyclic voltammetry and glassy carbon working electrode, only one irreversible anodic peak was observed around 0.8 V for methylparaben (MP), ethylparaben (EP), propylparaben (PP), butylparaben (BP), benzylparaben (BzP) and p-substituted phenolic analogues. The electrodonating inductive effect of alkyl groups was demonstrated by the anodic oxidation potential shift to lower values as the carbon number increases and, therefore the parabens (and other phenolic analogues) oxidation processes to the quinonoidic forms showed great dependence on the substituent pattern.
Resumo:
Introduction: The objective of this study was to investigate correlations between pulp oxygenation rates (%SpO(2)) and clinical diagnoses of reversible pulpitis (RP), irreversible pulpitis (IP), or pulp necrosis (PN). Methods: Sixty patients who presented with a tooth with endodontic pathology were grouped according to a clinical diagnosis of either RP (n = 20), IP (n = 20), or PN (n = 20). The clinical diagnosis was based on the patient's dental history, periapical radiographs, clinical inspection, and percussion and thermal sensitivity testing. Pulse oximetry (PO) was used to determine pulp oxygenation rates. For every patient, one additional endodontically treated tooth (negative control [NC], n = 60) and one additional healthy tooth with healthy pulp status (positive control [PC], n = 60) were evaluated. Analysis of variance, the Tukey HSD test, and the Student's t test were used for statistical analysis. Results: The mean % SpO(2) levels were as follows: RP: 87.4% (standard deviation [SD] +/- 2.46), IP: 83.1% (SD +/- 2.29), PN: 74.6% (SD +/- 1.96), PC: 92.2% (SD +/- 1.84), and NC: 0% (SD +/- 0.0). There were statistically significant differences between RP, IP, and PM compared with NC and PC and between RP, IP, and PN (all P <= .01). Conclusions: The evaluation of pulp oxygenation rates by PO may be a useful tool to determine the different inflammatory stages of the pulp to aid in endodontic diagnosis. (JEndod 2012;38:880-883)
Resumo:
The Carr-Purcell pulse sequence, with low refocusing flip angle, produces echoes midway between refocusing pulses that decay to a minimum value dependent on T*(2). When the refocusing flip angle was pi/2 (CP90) and tau > T*(2), the signal after the minimum value, increased to reach a steady-state free precession regime (SSFP), composed of a free induction decay signal after each pulse and an echo, before the next pulse. When tau < T*(2), the signal increased from the minimum value to the steady-state regime with a time constant (T*) = 2T(1)T(2)/(T-1 + T-2). identical to the time constant observed in the SSFP sequence, known as the continuous wave free precession (CWFP). The steady-state amplitude obtained with M-cp90 = M0T2/(T-1+T-2) was identical to CWFP. Therefore, this sequence was named CP-CWFP because it is a Carr-Purcell sequence that produces results similar to the CWFP. However, CP-CWFP is a better sequence for measuring the longitudinal and transverse relaxation times in single scan, when the sample exhibits T-1 similar to T-2. Therefore, this sequence can be a useful method in time domain NMR and can be widely used in the agriculture, food and petrochemical industries because those samples tend to have similar relaxation times in low magnetic fields. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Abstract Background Medical oncologists continue to use performance status as a proxy for quality of life (QOL) measures, as completion of QOL instruments is perceived as time consuming, may measure aspects of QOL not affected by cancer therapy, and interpretation may be unclear. The pulse oximeter is widely used in clinical practice to predict cardiopulmonary morbidity after lung resection in cancer patients, but little is known on its role outside the surgical setting. We evaluated whether the Lung Cancer Symptom Scale and pulse oximetry may contribute to the evaluation of lung cancer patients who received standard anticancer therapy. Methods We enrolled forty-one consecutive, newly diagnosed, patients with locally advanced or metastatic lung cancer in this study. We developed a survival model with the variables gender, age, histology, clinical stage, Karnofsky performance status, wasting, LCSS symptom scores, average symptom burden index, and pulse oximetry (SpO2). Results Patient and observer-rated scores were correlated, except for the fatigue subscale. The median SpO2 was 95% (range: 86 to 98), was unrelated to symptom scores, and was weakly correlated with observer cough scores. In a multivariate survival model, SpO2 > 90% and patient scores on the LCSS appetite and fatigue subscales were independent predictors of survival. Conclusion LCSS fatigue and appetite rating, and pulse oximetry should be studied further as prognostic factors in lung cancer patients.
Resumo:
Abstract Background Experimental studies demonstrate that infection with trypanosoma cruzi causes vasculitis. The inflammatory lesion process could hypothetically lead to decreased distensibility of large and small arteries in advanced Chagas' disease. We tested this hypothesis. Methods and results We evaluated carotid-femoral pulse-wave velocity (PWV) in 53 Chagas' disease patients compared with 31 healthy volunteers (control group). The 53 patients were classified into 3 groups: 1) 16 with indeterminate form of Chagas' disease; 2) 18 with Chagas' disease, electrocardiographic abnormalities, and normal systolic function; 3) 19 with Chagas' disease, systolic dysfunction, and mild-to-moderate congestive heart failure. No difference was noted between the 4 groups regarding carotid-femoral PWV (8.4 ± 1.1 vs 8.2 ± 1.5 vs 8.2 ± 1.4 vs 8.7 ± 1.6 m/s, P = 0.6) or pulse pressure (39.5 ± 7.6 vs 39.3 ± 8.1 vs 39.5 ± 7.4 vs 39.7 ± 6.9 mm Hg, P = 0.9). A positive, significant, similar correlation occurred between PWV and age in patients with Chagas' disease (r = 0.42, P = 0.002), in controls (r = 0.48, P = 0.006), and also between PWV and systolic blood pressure in both groups (patients with Chagas' disease, r = 0.38, P = 0.005; healthy subjects, r = 0.36, P = 0.043). Conclusion Carotid femoral pulse-wave velocity is not modified in patients with Chagas' disease, suggesting that elastic properties of large arteries are not affected in this disorder.
Resumo:
Abstract Introduction Several studies have shown that maximizing stroke volume (or increasing it until a plateau is reached) by volume loading during high-risk surgery may improve post-operative outcome. This goal could be achieved simply by minimizing the variation in arterial pulse pressure (ΔPP) induced by mechanical ventilation. We tested this hypothesis in a prospective, randomized, single-centre study. The primary endpoint was the length of postoperative stay in hospital. Methods Thirty-three patients undergoing high-risk surgery were randomized either to a control group (group C, n = 16) or to an intervention group (group I, n = 17). In group I, ΔPP was continuously monitored during surgery by a multiparameter bedside monitor and minimized to 10% or less by volume loading. Results Both groups were comparable in terms of demographic data, American Society of Anesthesiology score, type, and duration of surgery. During surgery, group I received more fluid than group C (4,618 ± 1,557 versus 1,694 ± 705 ml (mean ± SD), P < 0.0001), and ΔPP decreased from 22 ± 75 to 9 ± 1% (P < 0.05) in group I. The median duration of postoperative stay in hospital (7 versus 17 days, P < 0.01) was lower in group I than in group C. The number of postoperative complications per patient (1.4 ± 2.1 versus 3.9 ± 2.8, P < 0.05), as well as the median duration of mechanical ventilation (1 versus 5 days, P < 0.05) and stay in the intensive care unit (3 versus 9 days, P < 0.01) was also lower in group I. Conclusion Monitoring and minimizing ΔPP by volume loading during high-risk surgery improves postoperative outcome and decreases the length of stay in hospital. Trial registration NCT00479011