884 resultados para detection performance
Resumo:
OBJECTIVE: The aim of this study was to determine the influence of polyvinyl chloride (PVC) wrapping on the performance of two laser fluorescence devices (LF and LFpen) by assessing tooth occlusal surfaces. BACKGROUND DATA: Protection of their tips may influence LF measurements. To date there are no studies evaluating the influence of this protection on the performance of the LFpen on permanent teeth, or comparing it to the original LF device. MATERIALS AND METHODS: One hundred nineteen permanent molars were assessed by two experienced dentists using the LF and the LFpen devices, both with and without PVC wrapping. The teeth were histologically prepared and assessed for caries extension. RESULTS: The LF values with and without PVC wrapping were significantly different. For both LF devices, the sensitivity and accuracy were lower when the PVC wrapping was used. The specificity was statistically significantly higher for the LFpen with PVC. No difference was found between the areas under the ROC curves with and without PVC wrapping. The ICC showed excellent interexaminer agreement. The Bland and Altman method showed a range between the upper and the lower limits of agreement of 63.4 and 57.8 units for the LF device, and 49.4 and 74.2 for the LFpen device, with and without PVC wrapping, respectively. CONCLUSIONS: We found an influence of the PVC wrapping on the performance of the LF and LFpen devices. However, since its influence on detection of occlusal caries lesions is considered for, the use of one PVC layer is suggested to avoid cross-contamination in clinical practice.
Resumo:
OBJECTIVE: In this experimental study we assessed the diagnostic performance of digital linear slit scanning radiography compared with computed radiography (CR) for the detection of urinary calculi in an anthropomorphic phantom imitating patients weighing approximately 58-88 kg. CONCLUSION: Compared with CR, linear slit scanning radiography is superior for the detection of urinary stones and may be used for pretreatment localization and follow-up at a lower patient exposure.
Resumo:
To master changing performance demands, autonomous transport vehicles are deployed to make inhouse material flow applications more flexible. The socalled cellular transport system consists of a multitude of small scale transport vehicles which shall be able to form a swarm. Therefore the vehicles need to detect each other, exchange information amongst each other and sense their environment. By provision of peripherally acquired information of other transport entities, more convenient decisions can be made in terms of navigation and collision avoidance. This paper is a contribution to collective utilization of sensor data in the swarm of cellular transport vehicles.
Resumo:
We present in this paper several contributions on the collision detection optimization centered on hardware performance. We focus on the broad phase which is the first step of the collision detection process and propose three new ways of parallelization of the well-known Sweep and Prune algorithm. We first developed a multi-core model takes into account the number of available cores. Multi-core architecture enables us to distribute geometric computations with use of multi-threading. Critical writing section and threads idling have been minimized by introducing new data structures for each thread. Programming with directives, like OpenMP, appears to be a good compromise for code portability. We then proposed a new GPU-based algorithm also based on the "Sweep and Prune" that has been adapted to multi-GPU architectures. Our technique is based on a spatial subdivision method used to distribute computations among GPUs. Results show that significant speed-up can be obtained by passing from 1 to 4 GPUs in a large-scale environment.
Children's performance estimation in mathematics and science tests over a school year: A pilot study
Resumo:
The metacognitve ability to accurately estimate ones performance in a test, is assumed to be of central importance for initializing task-oriented effort. In addition activating adequate problem-solving strategies, and engaging in efficient error detection and correction. Although school children's' ability to estimate their own performance has been widely investigated, this was mostly done under highly-controlled, experimental set-ups including only one single test occasion. Method: The aim of this study was to investigate this metacognitive ability in the context of real achievement tests in mathematics. Developed and applied by a teacher of a 5th grade class over the course of a school year these tests allowed the exploration of the variability of performance estimation accuracy as a function of test difficulty. Results: Mean performance estimations were generally close to actual performance with somewhat less variability compared to test performance. When grouping the children into three achievement levels, results revealed higher accuracy of performance estimations in the high achievers compared to the low and average achievers. In order to explore the generalization of these findings, analyses were also conducted for the same children's tests in their science classes revealing a very similar pattern of results compared to the domain of mathematics. Discussion and Conclusion: By and large, the present study, in a natural environment, confirmed previous laboratory findings but also offered additional insights into the generalisation and the test dependency of students' performances estimations.
Resumo:
Three field isolates of small ruminant lentiviruses (SRLVs) were derived from a mixed flock of goats and sheep certified for many years as free of caprine arthritis encephalitis virus (CAEV). The phylogenetic analysis of pol sequences permitted to classify these isolates as A4 subtype. None of the animals showed clinical signs of SRLV infection, confirming previous observations which had suggested that this particular subtype is highly attenuated, at least for goats. A quantitative real time PCR strategy based on primers and probes derived from a highly variable env region permitted us to classify the animals as uninfected, singly or doubly infected. The performance of different serological tools based on this classification revealed their profound inadequacy in monitoring animals infected with this particular SRLV subtype. In vitro, the isolates showed differences in their cytopathicity and a tendency to replicate more efficiently in goat than sheep cells, especially in goat macrophages. By contrast, in vivo, these viruses reached significantly higher viral loads in sheep than in goats. Both env subtypes infected goats and sheep with equal efficiency. One of these, however, reached significantly higher viral loads in both species. In conclusion, we characterized three isolates of the SRLV subtype A4 that efficiently circulate in a mixed herd of goats and sheep in spite of their apparent attenuation and a strict physical separation between goats and sheep. The poor performance of the serological tools applied indicates that, to support an SRLV eradication campaign, it is imperative to develop novel, subtype specific tools.
Resumo:
BACKGROUND: Virtual reality testing of everyday activities is a novel type of computerized assessment that measures cognitive, executive, and motor performance as a screening tool for early dementia. This study used a virtual reality day-out task (VR-DOT) environment to evaluate its predictive value in patients with mild cognitive impairment (MCI). METHODS: One hundred thirty-four patients with MCI were selected and compared with 75 healthy control subjects. Participants received an initial assessment that included VR-DOT, a neuropsychological evaluation, magnetic resonance imaging (MRI) scan, and event-related potentials (ERPs). After 12 months, participants were assessed again with MRI, ERP, VR-DOT, and neuropsychological tests. RESULTS: At the end of the study, we differentiated two subgroups of patients with MCI according to their clinical evolution from baseline to follow-up: 56 MCI progressors and 78 MCI nonprogressors. VR-DOT performance profiles correlated strongly with existing predictive biomarkers, especially the ERP and MRI biomarkers of cortical thickness. CONCLUSIONS: Compared with ERP, MRI, or neuropsychological tests alone, the VR-DOT could provide additional predictive information in a low-cost, computerized, and noninvasive way.
Resumo:
OBJECTIVE: We sought to evaluate the performance of the human papillomavirus high-risk DNA test in patients 30 years and older. MATERIALS AND METHODS: Screening (n=835) and diagnosis (n=518) groups were defined based on prior Papanicolaou smear results as part of a clinical trial for cervical cancer detection. We compared the Hybrid Capture II (HCII) test result with the worst histologic report. We used cervical intraepithelial neoplasia (CIN) 2/3 or worse as the reference of disease. We calculated sensitivities, specificities, positive and negative likelihood ratios (LR+ and LR-), receiver operating characteristic (ROC) curves, and areas under the ROC curves for the HCII test. We also considered alternative strategies, including Papanicolaou smear, a combination of Papanicolaou smear and the HCII test, a sequence of Papanicolaou smear followed by the HCII test, and a sequence of the HCII test followed by Papanicolaou smear. RESULTS: For the screening group, the sensitivity was 0.69 and the specificity was 0.93; the area under the ROC curve was 0.81. The LR+ and LR- were 10.24 and 0.34, respectively. For the diagnosis group, the sensitivity was 0.88 and the specificity was 0.78; the area under the ROC curve was 0.83. The LR+ and LR- were 4.06 and 0.14, respectively. Sequential testing showed little or no improvement over the combination testing. CONCLUSIONS: The HCII test in the screening group had a greater LR+ for the detection of CIN 2/3 or worse. HCII testing may be an additional screening tool for cervical cancer in women 30 years and older.
Resumo:
Key performance features of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations of the chemical composition of planetary surfaces are presented. This mass spectrometer is well suited for elemental and isotopic analysis of raw solid materials with high sensitivity and high spatial resolution. In this study, ultraviolet laser radiation with irradiances suitable for ablation (< 1 GW/cm2) is used to achieve stable ion formation and low sample consumption. In comparison to our previous laser ablation studies at infrared wavelengths, several improvements to the experimental setup have been made, which allow accurate control over the experimental conditions and good reproducibility of measurements. Current performance evaluations indicate significant improvements to several instrumental figures of merit. Calibration of the mass scale is performed within a mass accuracy (Δm/m) in the range of 100 ppm, and a typical mass resolution (m/Δm) ~600 is achieved at the lead mass peaks. At lower laser irradiances, the mass resolution is better, about (m/Δm) ~900 for lead, and limited by the laser pulse duration of 3 ns. The effective dynamic range of the instrument was enhanced from about 6 decades determined in previous study up to more than 8 decades at present. Current studies show high sensitivity in detection of both metallic and non-metallic elements. Their abundance down to tens of ppb can be measured together with their isotopic patterns. Due to strict control of the experimental parameters, e.g. laser characteristics, ion-optical parameters and sample position, by computer control, measurements can be performed with high reproducibility. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
Background Atrial fibrillation (AF) is common and may have severe consequences. Continuous long-term electrocardiogram (ECG) is widely used for AF screening. Recently, commercial ECG analysis software was launched, which automatically detects AF in long-term ECGs. It has been claimed that such tools offer reliable AF screening and save time for ECG analysis. However, this has not been investigated in a real-life patient cohort. Objective To investigate the performance of automatic software-based screening for AF in long-term ECGs. Methods Two independent physicians manually screened 22,601 hours of continuous long-term ECGs from 150 patients for AF. Presence, number, and duration of AF episodes were registered. Subsequently, the recordings were screened for AF by an established ECG analysis software (Pathfinder SL), and its performance was validated against the thorough manual analysis (gold standard). Results Sensitivity and specificity for AF detection was 98.5% (95% confidence interval 91.72%–99.96%) and 80.21% (95% confidence interval 70.83%–87.64%), respectively. Software-based AF detection was inferior to manual analysis by physicians (P < .0001). Median AF duration was underestimated (19.4 hours vs 22.1 hours; P < .001) and median number of AF episodes was overestimated (32 episodes vs 2 episodes; P < .001) by the software. In comparison to extensive quantitative manual ECG analysis, software-based analysis saved time (2 minutes vs 19 minutes; P < .001). Conclusion Owing to its high sensitivity and ability to save time, software-based ECG analysis may be used as a screening tool for AF. An additional manual confirmatory analysis may be required to reduce the number of false-positive findings.
Resumo:
A new technique for the detection of microbiological fecal pollution in drinking and in raw surface water has been modified and tested against the standard multiple-tube fermentation technique (most-probable-number, MPN). The performance of the new test in detecting fecal pollution in drinking water has been tested at different incubation temperatures. The basis for the new test was the detection of hydrogen sulfide produced by the hydrogen sulfide producing bacteria which are usually associated with the coliform group. The positive results are indicated by the appearance of a brown to black color in the contents of the fermentation tube within 18 to 24 hours of incubation at 35 (+OR-) .5(DEGREES)C. For this study 158 water samples of different sources have been used. The results were analyzed statistically with the paired t-test and the one-way analysis of variance. No statistically significant difference was noticed between the two methods, when tested 35 (+OR-) .5(DEGREES)C, in detecting fecal pollution in drinking water. The new test showed more positive results with raw surface water, which could be due to the presence of hydrogen sulfide producing bacteria of non-fecal origin like Desulfovibrio and Desulfomaculum. The survival of the hydrogen sulfide producing bacteria and the coliforms was also tested over a 7-day period, and the results showed no significant difference. The two methods showed no significant difference when used to detect fecal pollution at a very low coliform density. The results showed that the new test is mostly effective, in detecting fecal pollution in drinking water, when used at 35 (+OR-) .5(DEGREES)C. The new test is effective, simple, and less expensive when used to detect fecal pollution in drinking water and raw surface water at 35 (+OR-) .5(DEGREES)C. The method can be used for qualitative and/or quantitative analysis of water in the field and in the laboratory. ^
Resumo:
Contemporary models of self-regulated learning emphasize the role of distal motivational factors for student's achievement, on the one side, and the proximal role of metacognitive monitoring and control for learning and test outcomes, on the other side. In the present study, two larger samples of elementary school children (9- and 11-year-olds) were included and their mastery-oriented motivation, metacognitive monitoring and control skills were integrated into structural equation models testing and comparing the relative impact of these different constituents for self-regulated learning. For one, results indicate that the factorial structure of monitoring, control and mastery motivation was invariant across the two age groups. Of specific interest was the finding that there were age-dependent structural links between monitoring, control, and test performance (closer links in the older compared to the younger children), with high confidence yielding a direct and positive effect on test performance and a direct and negative effect on adequate control behavior in the achievement test. Mastery-oriented motivation was not found to be substantially associated with monitoring (confidence), control (detection and correction of errors), or test performance underlining the importance of proximal, metacognitive factors for test performance in elementary school children.
Resumo:
The near-real time retrieval of low stratiform cloud (LSC) coverage is of vital interest for such disciplines as meteorology, transport safety, economy and air quality. Within this scope, a novel methodology is proposed which provides the LSC occurrence probability estimates for a satellite scene. The algorithm is suited for the 1 × 1 km Advanced Very High Resolution Radiometer (AVHRR) data and was trained and validated against collocated SYNOP observations. Utilisation of these two combined data sources requires a formulation of constraints in order to discriminate cases where the LSC is overlaid by higher clouds. The LSC classification process is based on six features which are first converted to the integer form by step functions and combined by means of bitwise operations. Consequently, a set of values reflecting a unique combination of those features is derived which is further employed to extract the LSC occurrence probability estimates from the precomputed look-up vectors (LUV). Although the validation analyses confirmed good performance of the algorithm, some inevitable misclassification with other optically thick clouds were reported. Moreover, the comparison against Polar Platform System (PPS) cloud-type product revealed superior classification accuracy. From the temporal perspective, the acquired results reported a presence of diurnal and annual LSC probability cycles over Europe.
Resumo:
We provide a novel search technique which uses a hierarchical model and a mutual information gain heuristic to efficiently prune the search space when localizing faces in images. We show exponential gains in computation over traditional sliding window approaches, while keeping similar performance levels.
Resumo:
PURPOSE To prospectively assess the diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of pelvic lymph node metastases in patients with prostate and/or bladder cancer staged as N0 with preoperative cross-sectional imaging. MATERIALS AND METHODS This study was approved by an independent ethics committee. Written informed consent was obtained from all patients. Patients with no enlarged lymph nodes on preoperative cross-sectional images who were scheduled for radical resection of the primary tumor and extended pelvic lymph node dissection were enrolled. All patients were examined with a 3-T MR unit, and examinations included conventional and DW MR imaging of the entire pelvis. Image analysis was performed by three independent readers blinded to any clinical information. Metastases were diagnosed on the basis of high signal intensity on high b value DW MR images and morphologic features (shape, border). Histopathologic examination served as the standard of reference. Sensitivity and specificity were calculated, and bias-corrected 95% confidence intervals (CIs) were obtained with the bootstrap method. The Fleiss and Cohen κ and median test were applied for statistical analyses. RESULTS A total of 4846 lymph nodes were resected in 120 patients. Eighty-eight lymph node metastases were found in 33 of 120 patients (27.5%). Short-axis diameter of these metastases was less than or equal to 3 mm in 68, more than 3 mm to 5 mm in 13, more than 5 mm to 8 mm in five; and more than 8 mm in two. On a per-patient level, the three readers correctly detected metastases in 26 (79%; 95% CI: 64%, 91%), 21 (64%; 95% CI: 45%, 79%), and 25 (76%; 95% CI: 60%, 90%) of the 33 patients with metastases, with respective specificities of 85% (95% CI: 78%, 92%), 79% (95% CI: 70%, 88%), and 84% (95% CI: 76%, 92%). Analyzed according to hemipelvis, lymph node metastases were detected with histopathologic examination in 44 of 240 pelvic sides (18%); the three readers correctly detected these on DW MR images in 26 (59%; 95% CI: 45%, 73%), 19 (43%; 95% CI: 27%, 57%), and 28 (64%; 95% CI: 47%, 78%) of the 44 cases. CONCLUSION DW MR imaging enables noninvasive detection of small lymph node metastases in normal-sized nodes in a substantial percentage of patients with prostate and bladder cancer diagnosed as N0 with conventional cross-sectional imaging techniques.