990 resultados para dental patient


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous titanium samples were manufactured using the 3D printing and sintering method in order to determine the effects of final sintering temperature on morphology and mechanical properties. Cylindrical samples were printed and split into groups according to a final sintering temperature (FST). Irregular geometry samples were also printed and split into groups according to their FST. The cylindrical samples were used to determine part shrinkage, in compressive tests to provide stress-strain data, in microCT scans to provide internal morphology data and for optical microscopy to determine surface morphology. All of the samples were used in microhardness testing to establish the hardness. Below 1100 C FST, shrinkage was in the region of 20% but increased to approximately 30% by a FST of 1300 C. Porosity varied from a maximum of approximately 65% at the surface to the region of 30% internally. Between 97 and 99% of the internal porosity is interconnected. Average pore size varied between 24 µm at the surface and 19 µm internally. Sample hardness increased to in excess of 300 HV0.05 with increasing FST while samples with an FST of below 1250 C produced an elastic-brittle stress/strain curve and samples above this displayed elastic-plastic behaviour. Yield strength increased significantly through the range of sintering temperatures while the Young's modulus remained fairly consistent. © 2013 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ratings awarded by standardised patients (SPs) in UK objective structured clinical examinations (OSCEs) are typically based on humanistic (non-technical) skills and are complementary to clinician-examiner ratings. In psychometric terms, SP ratings appear to differ from examiner ratings and improve reliability. For the first time, we used qualitative methods from a constructivist perspective to explore SP experiences of rating, and consider how these impact our understanding of assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endodontic lubricants, irrigating solutions and medicaments help reduce the microbial load within root canals. Primary and secondary cases involve different microbes. Each'solution'or combinations thereof could play a significant role but no detailed guidelines exist on their use. An audit was undertaken to compare current practice in Belfast Dental School to the others across the UK and Republic of Ireland (ROI). This audit highlighted three main differences between Belfast and other dental schools. Many other institutions utilized other irrigants besides sodium hypochlorite (NaOCl), different intracanal medicaments, including calcium hydroxide, and higher concentrations of NaOCl. Having gathered this information, we ask, 'Is there sufficient evidence to change the endodontic regime currently used at Belfast Dental School?'. Using the findings from the literature review (Part 1), we introduce new evidence-based protocols for primary and secondary cases for use in Belfast Dental School. Clinical Relevance: In the absence of detailed clinical guidelines on the use of endodontic lubricants, irrigants and medicaments in primary and secondary cases, it is important to be aware of current practice in UK and ROI dental schools where dentists and specialists are trained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate dental erosion among 12-14 year old Sudanese school children and evaluate the associated risk factors. Basic Research Design: Cross sectional survey in secondary schools in Khartoum city, Sudan. Method and Participants: A sample of 157 school children was obtained from both private and public schools. Erosion on the labial and palatal surfaces of maxillary incisors was measured by criterion based on the Smith and Knight Tooth Wear Index. Dietary intake and other related factors were assessed using a questionnaire. Results: The overall erosion prevalence in this group was 66.9%, of which 45.2% was mild and 21.7% was moderate erosion. A strong association was found between erosion and private schooling (higher socioeconomic groups), carbonated drinks, herbal hibiscus drink and traditional acidic food consumption. Conclusion: There was a high prevalence of dental erosion among Sudanese school children which was mild to moderate in severity and was strongly associated with acidic dietary intake © BASCD 2007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe, for the first time, the microbial characterisation of hydrogel-forming polymeric microneedle arrays and the potential for passage of microorganisms into skin following microneedle penetration. Uniquely, we also present insights into the storage stability of these hydroscopic formulations, from physical and microbiological viewpoints, and examine clinical performance and safety in human volunteers. Experiments employing excised porcine skin and radiolabelled microorganisms showed that microorganisms can penetrate skin beyond the stratum corneum following microneedle puncture. Indeed, the numbers of microorganisms crossing the stratum corneum following microneedle puncture were greater than 105 cfu in each case. However, no microorganisms crossed the epidermal skin. When using a 21G hypodermic needle, more than 104 microorganisms penetrated into the viable tissue and 106 cfu of Candida albicans and Staphylococcus epidermidis completely crossed the epidermal skin in 24 h. The hydrogel-forming materials contained no microorganisms following de-moulding and exhibited no microbial growth during storage, while also maintaining their mechanical strength, apart from when stored at relative humidities of 86%. No microbial penetration through the swelling microneedles was detectable, while human volunteer studies confirmed that skin or systemic infection is highly unlikely when polymeric microneedles are used for transdermal drug delivery. Since no pharmacopoeial standards currently exist for microneedle-based products, the exact requirements for a proprietary product based on hydrogel-forming microneedles are at present unclear. However, we are currently working towards a comprehensive specification set for this microneedle system that may inform future developments in this regard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract
INTRODUCTION:
Transient receptor potential (TRP) channels comprise a group of nonselective calcium-permeable cationic channels, which are polymodal sensors of environmental stimuli such as thermal changes and chemicals. TRPM8 and TRPA1 are cold-sensing TRP channels activated by moderate cooling and noxious cold temperatures, respectively. Both receptors have been identified in trigeminal ganglion neurones, and their expression in nonneuronal cells is now the focus of much interest. The aim of this study was to investigate the molecular and functional expression of TRPA1 and TRPM8 in dental pulp fibroblasts.
METHODS:
Human dental pulp fibroblasts were derived from healthy molar teeth. Gene and protein expression was determined by polymerase chain reaction and Western blotting. Cellular localization was investigated by immunohistochemistry, and TRP functionality was determined by Ca(2+) microfluorimetry.
RESULTS:
Polymerase chain reaction and Western blotting showed gene and protein expression of both TRPA1 and TRPM8 in fibroblast cells in culture. Immunohistochemistry studies showed that TRPA1 and TRPM8 immunoreactivity co-localized with the human fibroblast surface protein. In Ca(2+) microfluorimetry studies designed to determine the functionality of TRPA1 and TRPM8 in pulp fibroblasts, we showed increased intracellular calcium ([Ca(2+)](i)) in response to the TRPM8 agonist menthol, the TRPA1 agonist cinnamaldehyde, and to cool and noxious cold stimuli, respectively. The responses to agonists and thermal stimuli were blocked in the presence of specific TRPA1 and TRPM8 antagonists.
CONCLUSIONS:
Human dental pulp fibroblasts express TRPA1 and TRPM8 at the molecular, protein, and functional levels, indicating a possible role for fibroblasts in mediating cold responses in human teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to report the analysis of the concept of vulnerability. Literature searches were conducted as well as a manual library search from article reference lists. Retrieved literature was analysed using the Walker & Advant (2005) concept analysis framework. The study concludes that inclusion of the concept of vulnerability within both pre- and post-registration training programmes would facilitate awareness of the issues surrounding perioperative vulnerability and the need to plan individualised care accordingly. It is hoped that this analysis will inspire further research and theoretical underpinning of perioperative practice, facilitating the development of new ways to manage vulnerability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research reports on a survey of 228 blind and partially sighted persons in 15 health authorities across Scotland. The survey reports data on patient experience of receiving health information in accessible reading formats. Data indicated that about 90% of blind and partially sighted persons did not receive communications from various NHS health departments in a format that they could read by themselves. The implications for patient privacy, confidentiality and wider impact on life and health care are highlighted. The implications for professional ethical medical practice and for public policy are also discussed. Recommendations for improved practice are made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Angiotensin-converting enzyme inhibitors (ACEIs) and angiotensin II receptor blockers (ARBs) are commonly prescribed to the growing number of cancer patients (more than two million in the UK alone) often to treat hypertension. However, increased fatal cancer in ARB users in a randomized trial and increased breast cancer recurrence rates in ACEI users in a recent observational study have raised concerns about their safety in cancer patients. We investigated whether ACEI or ARB use after breast, colorectal or prostate cancer diagnosis was associated with increased risk of cancer-specific mortality.

Methods: Population-based cohorts of 9,814 breast, 4,762 colorectal and 6,339 prostate cancer patients newly diagnosed from 1998 to 2006 were identified in the UK Clinical Practice Research Datalink and confirmed by cancer registry linkage. Cancer-specific and all-cause mortality were identified from Office of National Statistics mortality data in 2011 (allowing up to 13 years of follow-up). A nested case–control analysis was conducted to compare ACEI/ARB use (from general practitioner prescription records) in cancer patients dying from cancer with up to five controls (not dying from cancer). Conditional logistic regression estimated the risk of cancer-specific, and all-cause, death in ACEI/ARB users compared with non-users.

Results: The main analysis included 1,435 breast, 1,511 colorectal and 1,184 prostate cancer-specific deaths (and 7,106 breast, 7,291 colorectal and 5,849 prostate cancer controls). There was no increase in cancer-specific mortality in patients using ARBs after diagnosis of breast (adjusted odds ratio (OR) = 1.06 95% confidence interval (CI) 0.84, 1.35), colorectal (adjusted OR = 0.82 95% CI 0.64, 1.07) or prostate cancer (adjusted OR = 0.79 95% CI 0.61, 1.03). There was also no evidence of increases in cancer-specific mortality with ACEI use for breast (adjusted OR = 1.06 95% CI 0.89, 1.27), colorectal (adjusted OR = 0.78 95% CI 0.66, 0.92) or prostate cancer (adjusted OR = 0.78 95% CI 0.66, 0.92).

Conclusions: Overall, we found no evidence of increased risks of cancer-specific mortality in breast, colorectal or prostate cancer patients who used ACEI or ARBs after diagnosis. These results provide some reassurance that these medications are safe in patients diagnosed with these cancers.

Keywords: Colorectal cancer; Breast cancer; Prostate cancer; Mortality; Angiotensin-converting enzyme inhibitors and angiotensin II receptor blockers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this research is to use finite element analysis (FEA) to quantify the effect of the sample shape and the imperfections induced during the manufacturing process of samples on the bond strength and modes of failure of dental adhesive systems through microtensile test. Using the FEA prediction for individual parameters effect, estimation of expected variation and spread of the microtensile bond strength results for different sample geometries is made. Methods: The estimated stress distributions for three different sample shapes, hourglass, stick and dumbbell predicted by FEA are used to predict the strength for different fracture modes. Parameters such as the adhesive thickness, uneven interface of the adhesive and composite and dentin, misalignment of axis of loading, the existence of flaws such as induced cracks during shaping the samples or bubbles created during application of the adhesive are considered. Microtensile experiments are performed simultaneously to measure bond strength and modes of failure. These are compared with the FEA results. Results: The relative bonding strength and its standard deviation for the specimens with different geometries measured through the microtensile tests confirm the findings of the FEA. The hourglass shape samples show lower tensile bond strength and standard deviation compared to the stick and dumbbell shape samples. ANOVA analysis confirms no significant difference between dumbbell and stick geometry results, and major differences of these two geometries compared to hourglass shape measured values. Induced flaws in the adhesive and misalignment of the angle of application of load have significant effect on the microtensile bond strength. Using adhesive with higher modulus the differences between the bond strength of the three sample geometries increase. Significance: The result of the research clarifies the importance of the sample geometry chosen in measuring the bond strength. It quantifies the effect of the imperfections on the bond strength for each of the sample geometries through a systematic and all embracing study. The results explain the reasons of the large spread of the microtensile test results reported by various researchers working in different labs and the need for standardization of the test method and sample shape used in evaluation of the dentin-adhesive bonding system. © 2007 Academy of Dental Materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research aims to carry out a detailed analysis of the loads applied by the ambulance workers when loading/unloading ambulance stretchers. The forces required of the ambulance workers for each system are measured using a load cell in a force handle arrangement. The process of loading and unloading is video recorded for all the systems to register the posture of the ambulance workers in different stages of the process. The postures and forces exerted by the ambulance workers are analyzed using biomechanical assessment software to examine if the work loads at any stage of the process are harmful. Kinetic analysis of each stretcher loading system is performed. Comparison of the kinetic analysis and measurements shows very close agreement for most of the cases. The force analysis results are evaluated against derived failure criteria. The evaluation is extended to a biomechanical failure analysis of the ambulance worker's lower back using 3DSSPP software developed at the Centre for Ergonomics at the University of Michigan. The critical tasks of each ambulance worker during the loading and unloading operations for each system are identified. Design recommendations are made to reduce the forces exerted based on loading requirements from the kinetic analysis. © 2006 IPEM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A set of cylindrical porous titanium test samples were produced using the three-dimensional printing and sintering method with samples sintered at 900 °C, 1000 °C, 1100 °C, 1200 °C or 1300 °C. Following compression testing, it was apparent that the stress-strain curves were similar in shape to the curves that represent cellular solids. This is despite a relative density twice as high as what is considered the threshold for defining a cellular solid. As final sintering temperature increased, the compressive behaviour developed from being elastic-brittle to elastic-plastic and while Young's modulus remained fairly constant in the region of 1.5 GPa, there was a corresponding increase in 0.2% proof stress of approximately 40-80 MPa. The cellular solid model consists of two equations that predict Young's modulus and yield or proof stress. By fitting to experimental data and consideration of porous morphology, appropriate changes to the geometry constants allow modification of the current models to predict with better accuracy the behaviour of porous materials with higher relative densities (lower porosity).